{"title":"Inverted Bucket Steam Traps","description":"","products":[{"product_id":"watson-mcdaniel-ib1031-series-inverted-bucket-steam-trap-cast-iron-body-125-psig-in-line-repairability-1-2-npt","title":"Watson McDaniel IB1031 Series Inverted Bucket Steam Trap, Cast Iron Body, 125 PSIG, In-line Repairability, 1\/2\" NPT","description":"\u003ch2\u003eWatson McDaniel IB1031 Series Inverted Bucket Steam Trap - 1\/2\" NPT (125 PSIG)\u003c\/h2\u003e \u003ch2\u003eFeatures:\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eWaterhammer Resistant\u003c\/li\u003e \u003cli\u003eSuitable for superheated steam (use internal check valve option to eliminate loss of prime)\u003c\/li\u003e \u003cli\u003eIn-line repairability is simplified by having all internals attached to the cover\u003c\/li\u003e \u003cli\u003eValve \u0026amp; seat are located at the top of the trap body making them less prone to clogging from debris and pipe scale\u003c\/li\u003e \u003cli\u003eAll stainless steel internals with hardened valve \u0026amp; seat\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e \u003ch2\u003eIB1031 Series\u003c\/h2\u003e \u003cp\u003eThe IB1031 series is the smallest of the IB series. It has a max operating pressure (PMO) of up to 150 PSIG and at max differential pressure, it can handle up to 690 lbs\/hr of condensate.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eDRIP, TRACING, PROCESS:\u003c\/strong\u003e IB Series inverted bucket steam traps are used in drip applications to remove condensate from steam mains and steam supply lines. For drip applications, the smaller sized units have adequate capacity. The discharge orifice of the inverted bucket trap is mounted at the top of the trap body, which makes them less susceptible to failure from dirt and debris when compared to other trap types. Since Inverted Bucket traps have poor air-handling capability, they are normally not recommended for most process applications. However, they can be used on certain process applications such as unit heaters and laundry equipment,where discharging air during system start-up is not a critical factor. F\u0026amp;T traps are the preferred choice for systems where air must be quickly discharged.\u003c\/p\u003e \u003ch2\u003eHow It Works\u003c\/h2\u003e \u003cp\u003eWhen the trap is filled with condensate, the inverted bucket inside the steam trap loses its buoyancy and rests on the bottom of the trap. This pulls the disc off the seat allowing condensate to be discharged through the seat orifice located at the top of the trap. When steam enters, it fills the inverted bucket causing the bucket to float to the surface which closes the discharge valve, containing the steam in the system. Eventually, the steam is bled off through a small hole in the top of the bucket causing it to sink, which repeats the cycle.\u003c\/p\u003e \u003ch2\u003eSelection \/ Sizing \/ Capacities\u003c\/h2\u003e \u003cp\u003e\u003cstrong\u003eSelect A Model With A Higher Maximum Operating Pressure (PMO)\u003c\/strong\u003e that Meet or Exceed the Maximum Steam Pressure or The Trap May Not Open. for Example, the Ib-1031-13-N-150 Has a Max Pmo of 150 Psi, Will Handle Capacity up To 570 Lbs\/hr at Maximum. Choose a Model that Will Handle the Capacity Requirement Based on The Differential Pressure Across the Trap. Reference Capacity Charts.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eExample:\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eApplication: 100 Lbs\/hr at 75 Psig Working Pressure and 2 Psi Differential Pressure\u003c\/li\u003e \u003cli\u003eSize\/model: Ib1031, 80 Psig, Specify Pipe Size (1\/2\", 3\/4\"), or Ib1041, 80 Psig, Specify Pipe Size (3\/4\", 1\").\u003c\/li\u003e \u003c\/ul\u003e \u003ch2\u003eOptions\u003c\/h2\u003e \u003cp\u003eStrainer and Blowdown valve connection available on 1041, 1042, 1044 \u0026amp; 1038S. We also have 3 accessories for this trap are Thermic vent to improve air handling capability. Internal check valve for superheated or condensate backflow applications.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eHow to Order Accessories:\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eCheck Valve (Suffix \u003cstrong\u003eCV\u003c\/strong\u003e) Built-in Inlet Check Valve is recommended when used on Superheated Steam\u003cbr\u003e \u003cul\u003e \u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eCV\u003c\/strong\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003cli\u003eThermic Vent (Suffix \u003cstrong\u003eTV\u003c\/strong\u003e) A Thermic Vent is recommended when using a Bucket Trap on any type of process application or where the removal of air from the system is critical.\u003cbr\u003e \u003cul\u003e \u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTV\u003c\/strong\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003cli\u003eThermic Vent \u0026amp; Check Valve (Suffix \u003cstrong\u003eTCV\u003c\/strong\u003e) For combination of Check Valve \u0026amp; Thermic Vent\u003cbr\u003e \u003cul\u003e \u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTCV\u003c\/strong\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003ch2\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e \u003cp\u003eTrap must be installed in upright position to function properly. All working components can be replaced with the trap body remaining in-line. With superheated steam, a check valve should be installed at inlet or trap may lose prime. A replacement kit containing the lever and seat assembly is a more economical option than replacing the entire steam trap. Also available are replacement screens, gaskets and buckets. When ordering replacement lever and seat assemblies, specify model and operating pressure. See Replacement Parts and Kits Section for exact cross-reference to Armstrong PCA (Pressure Change Assembly) kits.\u003c\/p\u003e \u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e \u003cdiv class=\"tech\"\u003e \u003ch2\u003eTechnical Specifications\u003c\/h2\u003e \u003cdiv class=\"specs\"\u003e \u003cdiv class=\"column\"\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eModel\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e1031\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eSizes\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e1\/2\"\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eConnections\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eNPT\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eBody Material\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eCast Iron\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eInternal check valve, Thermic vent\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"column\"\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003ePMO Max. Operating Pressure\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e125 PSIG\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eTMO Max. Operating Temperature\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e450°F\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003ePMA Max. Allowable Pressure\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e250 PSIG up to 450°F\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eTMA Max. Allowable Temperature\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e450°F @ 250 PSIG\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e \u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap-Spec-Sheet.pdf?v=1786494449\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"Watson McDaniel","offers":[{"title":"Default Title","offer_id":44165897125966,"sku":"WM-IB1031-12-125","price":217.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap__17988.1784299742.1280.1280.jpg?v=1786663359"},{"product_id":"watson-mcdaniel-ib1031-12-n-125-inverted-bucket-steam-trap-cast-iron-body-125-psig-in-line-repairability-npt","title":"Watson McDaniel IB1031-12-N-125 Inverted Bucket Steam Trap, Cast Iron Body, 125 PSIG, In-line Repairability, NPT","description":"\u003ch2\u003eWatson McDaniel IB1031-12-N-125 Inverted Bucket Steam Trap - 1\/2\" NPT (125 PSIG)\u003c\/h2\u003e \u003ch2\u003eFeatures:\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eWaterhammer Resistant\u003c\/li\u003e \u003cli\u003eSuitable for superheated steam (use internal check valve option to eliminate loss of prime)\u003c\/li\u003e \u003cli\u003eIn-line repairability is simplified by having all internals attached to the cover\u003c\/li\u003e \u003cli\u003eValve \u0026amp; seat are located at the top of the trap body making them less prone to clogging from debris and pipe scale\u003c\/li\u003e \u003cli\u003eAll stainless steel internals with hardened valve \u0026amp; seat\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e \u003ch2\u003eIB1031 Series\u003c\/h2\u003e \u003cp\u003eThe IB1031 series is the smallest of the IB series. It has a max operating pressure (PMO) of up to 150 PSIG and at max differential pressure, it can handle up to 690 lbs\/hr of condensate.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eDRIP, TRACING, PROCESS:\u003c\/strong\u003e IB Series inverted bucket steam traps are used in drip applications to remove condensate from steam mains and steam supply lines. For drip applications, the smaller sized units have adequate capacity. The discharge orifice of the inverted bucket trap is mounted at the top of the trap body, which makes them less susceptible to failure from dirt and debris when compared to other trap types. Since Inverted Bucket traps have poor air-handling capability, they are normally not recommended for most process applications. However, they can be used on certain process applications such as unit heaters and laundry equipment,where discharging air during system start-up is not a critical factor. F\u0026amp;T traps are the preferred choice for systems where air must be quickly discharged.\u003c\/p\u003e \u003ch2\u003eHow It Works\u003c\/h2\u003e \u003cp\u003eWhen the trap is filled with condensate, the inverted bucket inside the steam trap loses its buoyancy and rests on the bottom of the trap. This pulls the disc off the seat allowing condensate to be discharged through the seat orifice located at the top of the trap. When steam enters, it fills the inverted bucket causing the bucket to float to the surface which closes the discharge valve, containing the steam in the system. Eventually, the steam is bled off through a small hole in the top of the bucket causing it to sink, which repeats the cycle.\u003c\/p\u003e \u003ch2\u003eSelection \/ Sizing \/ Capacities\u003c\/h2\u003e \u003cp\u003e\u003cstrong\u003eSelect A Model With A Higher Maximum Operating Pressure (PMO)\u003c\/strong\u003e that Meet or Exceed the Maximum Steam Pressure or The Trap May Not Open. for Example, the Ib-1031-13-N-150 Has a Max Pmo of 150 Psi, Will Handle Capacity up To 570 Lbs\/hr at Maximum. Choose a Model that Will Handle the Capacity Requirement Based on The Differential Pressure Across the Trap. Reference Capacity Charts.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eExample:\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eApplication: 100 Lbs\/hr at 75 Psig Working Pressure and 2 Psi Differential Pressure\u003c\/li\u003e \u003cli\u003eSize\/model: Ib1031, 80 Psig, Specify Pipe Size (1\/2\", 3\/4\"), or Ib1041, 80 Psig, Specify Pipe Size (3\/4\", 1\").\u003c\/li\u003e \u003c\/ul\u003e \u003ch2\u003eOptions\u003c\/h2\u003e \u003cp\u003eStrainer and Blowdown valve connection available on 1041, 1042, 1044 \u0026amp; 1038S. We also have 3 accessories for this trap are Thermic vent to improve air handling capability. Internal check valve for superheated or condensate backflow applications.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eHow to Order Accessories:\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eCheck Valve (Suffix \u003cstrong\u003eCV\u003c\/strong\u003e) Built-in Inlet Check Valve is recommended when used on Superheated Steam\u003cbr\u003e \u003cul\u003e \u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eCV\u003c\/strong\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003cli\u003eThermic Vent (Suffix \u003cstrong\u003eTV\u003c\/strong\u003e) A Thermic Vent is recommended when using a Bucket Trap on any type of process application or where the removal of air from the system is critical.\u003cbr\u003e \u003cul\u003e \u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTV\u003c\/strong\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003cli\u003eThermic Vent \u0026amp; Check Valve (Suffix \u003cstrong\u003eTCV\u003c\/strong\u003e) For combination of Check Valve \u0026amp; Thermic Vent\u003cbr\u003e \u003cul\u003e \u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTCV\u003c\/strong\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003ch2\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e \u003cp\u003eTrap must be installed in upright position to function properly. All working components can be replaced with the trap body remaining in-line. With superheated steam, a check valve should be installed at inlet or trap may lose prime. A replacement kit containing the lever and seat assembly is a more economical option than replacing the entire steam trap. Also available are replacement screens, gaskets and buckets. When ordering replacement lever and seat assemblies, specify model and operating pressure. See Replacement Parts and Kits Section for exact cross-reference to Armstrong PCA (Pressure Change Assembly) kits.\u003c\/p\u003e \u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e \u003cdiv class=\"tech\"\u003e \u003ch2\u003eTechnical Specifications\u003c\/h2\u003e \u003cdiv class=\"specs\"\u003e \u003cdiv class=\"column\"\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eModel\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e1031\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eSizes\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e1\/2\"\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eConnections\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eNPT\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eBody Material\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eCast Iron\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eInternal check valve, Thermic vent\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003ePMO Max. Operating Pressure\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e125 PSIG\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"column\"\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eTMO Max. Operating Temperature\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e450°F\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003ePMA Max. Allowable Pressure\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e250 PSIG up to 450°F\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eTMA Max. Allowable Temperature\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e450°F @ 250 PSIG\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eIB1031-12-N-125\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e \u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap-Spec-Sheet.pdf?v=1786494449\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"Watson McDaniel","offers":[{"title":"Default Title","offer_id":44165897191502,"sku":"IB1031-12-N-125","price":217.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap__67336.1784299742.1280.1280.jpg?v=1786663361"},{"product_id":"watson-mcdaniel-ib1031-12-n-125-cv-inverted-bucket-steam-trap-cast-iron-body-125-psig-in-line-repairability-npt","title":"Watson McDaniel IB1031-12-N-125-CV Inverted Bucket Steam Trap, Cast Iron Body, 125 PSIG, In-line Repairability, NPT","description":"\u003ch2\u003eWatson McDaniel IB1031-12-N-125-CV Inverted Bucket Steam Trap - 1\/2\" NPT (125 PSIG)\u003c\/h2\u003e \u003ch2\u003eFeatures:\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eWaterhammer Resistant\u003c\/li\u003e \u003cli\u003eSuitable for superheated steam (use internal check valve option to eliminate loss of prime)\u003c\/li\u003e \u003cli\u003eIn-line repairability is simplified by having all internals attached to the cover\u003c\/li\u003e \u003cli\u003eValve \u0026amp; seat are located at the top of the trap body making them less prone to clogging from debris and pipe scale\u003c\/li\u003e \u003cli\u003eAll stainless steel internals with hardened valve \u0026amp; seat\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e \u003ch2\u003eIB1031 Series\u003c\/h2\u003e \u003cp\u003eThe IB1031 series is the smallest of the IB series. It has a max operating pressure (PMO) of up to 150 PSIG and at max differential pressure, it can handle up to 690 lbs\/hr of condensate.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eDRIP, TRACING, PROCESS:\u003c\/strong\u003e IB Series inverted bucket steam traps are used in drip applications to remove condensate from steam mains and steam supply lines. For drip applications, the smaller sized units have adequate capacity. The discharge orifice of the inverted bucket trap is mounted at the top of the trap body, which makes them less susceptible to failure from dirt and debris when compared to other trap types. Since Inverted Bucket traps have poor air-handling capability, they are normally not recommended for most process applications. However, they can be used on certain process applications such as unit heaters and laundry equipment,where discharging air during system start-up is not a critical factor. F\u0026amp;T traps are the preferred choice for systems where air must be quickly discharged.\u003c\/p\u003e \u003ch2\u003eHow It Works\u003c\/h2\u003e \u003cp\u003eWhen the trap is filled with condensate, the inverted bucket inside the steam trap loses its buoyancy and rests on the bottom of the trap. This pulls the disc off the seat allowing condensate to be discharged through the seat orifice located at the top of the trap. When steam enters, it fills the inverted bucket causing the bucket to float to the surface which closes the discharge valve, containing the steam in the system. Eventually, the steam is bled off through a small hole in the top of the bucket causing it to sink, which repeats the cycle.\u003c\/p\u003e \u003ch2\u003eSelection \/ Sizing \/ Capacities\u003c\/h2\u003e \u003cp\u003e\u003cstrong\u003eSelect A Model With A Higher Maximum Operating Pressure (PMO)\u003c\/strong\u003e that Meet or Exceed the Maximum Steam Pressure or The Trap May Not Open. for Example, the Ib-1031-13-N-150 Has a Max Pmo of 150 Psi, Will Handle Capacity up To 570 Lbs\/hr at Maximum. Choose a Model that Will Handle the Capacity Requirement Based on The Differential Pressure Across the Trap. Reference Capacity Charts.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eExample:\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eApplication: 100 Lbs\/hr at 75 Psig Working Pressure and 2 Psi Differential Pressure\u003c\/li\u003e \u003cli\u003eSize\/model: Ib1031, 80 Psig, Specify Pipe Size (1\/2\", 3\/4\"), or Ib1041, 80 Psig, Specify Pipe Size (3\/4\", 1\").\u003c\/li\u003e \u003c\/ul\u003e \u003ch2\u003eOptions\u003c\/h2\u003e \u003cp\u003eStrainer and Blowdown valve connection available on 1041, 1042, 1044 \u0026amp; 1038S. We also have 3 accessories for this trap are Thermic vent to improve air handling capability. Internal check valve for superheated or condensate backflow applications.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eHow to Order Accessories:\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eCheck Valve (Suffix \u003cstrong\u003eCV\u003c\/strong\u003e) Built-in Inlet Check Valve is recommended when used on Superheated Steam\u003cbr\u003e \u003cul\u003e \u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eCV\u003c\/strong\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003cli\u003eThermic Vent (Suffix \u003cstrong\u003eTV\u003c\/strong\u003e) A Thermic Vent is recommended when using a Bucket Trap on any type of process application or where the removal of air from the system is critical.\u003cbr\u003e \u003cul\u003e \u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTV\u003c\/strong\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003cli\u003eThermic Vent \u0026amp; Check Valve (Suffix \u003cstrong\u003eTCV\u003c\/strong\u003e) For combination of Check Valve \u0026amp; Thermic Vent\u003cbr\u003e \u003cul\u003e \u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTCV\u003c\/strong\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003ch2\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e \u003cp\u003eTrap must be installed in upright position to function properly. All working components can be replaced with the trap body remaining in-line. With superheated steam, a check valve should be installed at inlet or trap may lose prime. A replacement kit containing the lever and seat assembly is a more economical option than replacing the entire steam trap. Also available are replacement screens, gaskets and buckets. When ordering replacement lever and seat assemblies, specify model and operating pressure. See Replacement Parts and Kits Section for exact cross-reference to Armstrong PCA (Pressure Change Assembly) kits.\u003c\/p\u003e \u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e \u003cdiv class=\"tech\"\u003e \u003ch2\u003eTechnical Specifications\u003c\/h2\u003e \u003cdiv class=\"specs\"\u003e \u003cdiv class=\"column\"\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eModel\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e1031\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eSizes\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e1\/2\"\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eConnections\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eNPT\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eBody Material\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eCast Iron\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eInternal check valve, Thermic vent\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003ePMO Max. Operating Pressure\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e125 PSIG\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"column\"\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eTMO Max. Operating Temperature\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e450°F\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003ePMA Max. Allowable Pressure\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e250 PSIG up to 450°F\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eTMA Max. Allowable Temperature\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e450°F @ 250 PSIG\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eIB1031-12-N-125-CV\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e \u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap-Spec-Sheet.pdf?v=1786494449\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"Watson McDaniel","offers":[{"title":"Default Title","offer_id":44165897257038,"sku":"IB1031-12-N-125-CV","price":364.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap__12580.1784299742.1280.1280.jpg?v=1786663364"},{"product_id":"watson-mcdaniel-ib1031-12-n-125-tv-inverted-bucket-steam-trap-cast-iron-body-125-psig-in-line-repairability-npt","title":"Watson McDaniel IB1031-12-N-125-TV Inverted Bucket Steam Trap, Cast Iron Body, 125 PSIG, In-line Repairability, NPT","description":"\u003ch2\u003eWatson McDaniel IB1031-12-N-125-TV Inverted Bucket Steam Trap - 1\/2\" NPT (125 PSIG)\u003c\/h2\u003e \u003ch2\u003eFeatures:\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eWaterhammer Resistant\u003c\/li\u003e \u003cli\u003eSuitable for superheated steam (use internal check valve option to eliminate loss of prime)\u003c\/li\u003e \u003cli\u003eIn-line repairability is simplified by having all internals attached to the cover\u003c\/li\u003e \u003cli\u003eValve \u0026amp; seat are located at the top of the trap body making them less prone to clogging from debris and pipe scale\u003c\/li\u003e \u003cli\u003eAll stainless steel internals with hardened valve \u0026amp; seat\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e \u003ch2\u003eIB1031 Series\u003c\/h2\u003e \u003cp\u003eThe IB1031 series is the smallest of the IB series. It has a max operating pressure (PMO) of up to 150 PSIG and at max differential pressure, it can handle up to 690 lbs\/hr of condensate.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eDRIP, TRACING, PROCESS:\u003c\/strong\u003e IB Series inverted bucket steam traps are used in drip applications to remove condensate from steam mains and steam supply lines. For drip applications, the smaller sized units have adequate capacity. The discharge orifice of the inverted bucket trap is mounted at the top of the trap body, which makes them less susceptible to failure from dirt and debris when compared to other trap types. Since Inverted Bucket traps have poor air-handling capability, they are normally not recommended for most process applications. However, they can be used on certain process applications such as unit heaters and laundry equipment,where discharging air during system start-up is not a critical factor. F\u0026amp;T traps are the preferred choice for systems where air must be quickly discharged.\u003c\/p\u003e \u003ch2\u003eHow It Works\u003c\/h2\u003e \u003cp\u003eWhen the trap is filled with condensate, the inverted bucket inside the steam trap loses its buoyancy and rests on the bottom of the trap. This pulls the disc off the seat allowing condensate to be discharged through the seat orifice located at the top of the trap. When steam enters, it fills the inverted bucket causing the bucket to float to the surface which closes the discharge valve, containing the steam in the system. Eventually, the steam is bled off through a small hole in the top of the bucket causing it to sink, which repeats the cycle.\u003c\/p\u003e \u003ch2\u003eSelection \/ Sizing \/ Capacities\u003c\/h2\u003e \u003cp\u003e\u003cstrong\u003eSelect A Model With A Higher Maximum Operating Pressure (PMO)\u003c\/strong\u003e that Meet or Exceed the Maximum Steam Pressure or The Trap May Not Open. for Example, the Ib-1031-13-N-150 Has a Max Pmo of 150 Psi, Will Handle Capacity up To 570 Lbs\/hr at Maximum. Choose a Model that Will Handle the Capacity Requirement Based on The Differential Pressure Across the Trap. Reference Capacity Charts.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eExample:\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eApplication: 100 Lbs\/hr at 75 Psig Working Pressure and 2 Psi Differential Pressure\u003c\/li\u003e \u003cli\u003eSize\/model: Ib1031, 80 Psig, Specify Pipe Size (1\/2\", 3\/4\"), or Ib1041, 80 Psig, Specify Pipe Size (3\/4\", 1\").\u003c\/li\u003e \u003c\/ul\u003e \u003ch2\u003eOptions\u003c\/h2\u003e \u003cp\u003eStrainer and Blowdown valve connection available on 1041, 1042, 1044 \u0026amp; 1038S. We also have 3 accessories for this trap are Thermic vent to improve air handling capability. Internal check valve for superheated or condensate backflow applications.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eHow to Order Accessories:\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eCheck Valve (Suffix \u003cstrong\u003eCV\u003c\/strong\u003e) Built-in Inlet Check Valve is recommended when used on Superheated Steam\u003cbr\u003e \u003cul\u003e \u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eCV\u003c\/strong\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003cli\u003eThermic Vent (Suffix \u003cstrong\u003eTV\u003c\/strong\u003e) A Thermic Vent is recommended when using a Bucket Trap on any type of process application or where the removal of air from the system is critical.\u003cbr\u003e \u003cul\u003e \u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTV\u003c\/strong\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003cli\u003eThermic Vent \u0026amp; Check Valve (Suffix \u003cstrong\u003eTCV\u003c\/strong\u003e) For combination of Check Valve \u0026amp; Thermic Vent\u003cbr\u003e \u003cul\u003e \u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTCV\u003c\/strong\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003ch2\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e \u003cp\u003eTrap must be installed in upright position to function properly. All working components can be replaced with the trap body remaining in-line. With superheated steam, a check valve should be installed at inlet or trap may lose prime. A replacement kit containing the lever and seat assembly is a more economical option than replacing the entire steam trap. Also available are replacement screens, gaskets and buckets. When ordering replacement lever and seat assemblies, specify model and operating pressure. See Replacement Parts and Kits Section for exact cross-reference to Armstrong PCA (Pressure Change Assembly) kits.\u003c\/p\u003e \u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e \u003cdiv class=\"tech\"\u003e \u003ch2\u003eTechnical Specifications\u003c\/h2\u003e \u003cdiv class=\"specs\"\u003e \u003cdiv class=\"column\"\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eModel\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e1031\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eSizes\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e1\/2\"\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eConnections\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eNPT\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eBody Material\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eCast Iron\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eInternal check valve, Thermic vent\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003ePMO Max. Operating Pressure\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e125 PSIG\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"column\"\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eTMO Max. Operating Temperature\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e450°F\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003ePMA Max. Allowable Pressure\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e250 PSIG up to 450°F\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eTMA Max. Allowable Temperature\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e450°F @ 250 PSIG\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eIB1031-12-N-125-TV\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e \u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap-Spec-Sheet.pdf?v=1786494449\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"Watson McDaniel","offers":[{"title":"Default Title","offer_id":44165897322574,"sku":"IB1031-12-N-125-TV","price":435.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap__61885.1784299742.1280.1280.jpg?v=1786663366"},{"product_id":"watson-mcdaniel-ib1031-12-n-125-tcv-inverted-bucket-steam-trap-cast-iron-body-125-psig-in-line-repairability-npt","title":"Watson McDaniel IB1031-12-N-125-TCV Inverted Bucket Steam Trap, Cast Iron Body, 125 PSIG, In-line Repairability, NPT","description":"\u003ch2\u003eWatson McDaniel IB1031-12-N-125-TCV Inverted Bucket Steam Trap - 1\/2\" NPT (125 PSIG)\u003c\/h2\u003e \u003ch2\u003eFeatures:\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eWaterhammer Resistant\u003c\/li\u003e \u003cli\u003eSuitable for superheated steam (use internal check valve option to eliminate loss of prime)\u003c\/li\u003e \u003cli\u003eIn-line repairability is simplified by having all internals attached to the cover\u003c\/li\u003e \u003cli\u003eValve \u0026amp; seat are located at the top of the trap body making them less prone to clogging from debris and pipe scale\u003c\/li\u003e \u003cli\u003eAll stainless steel internals with hardened valve \u0026amp; seat\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e \u003ch2\u003eIB1031 Series\u003c\/h2\u003e \u003cp\u003eThe IB1031 series is the smallest of the IB series. It has a max operating pressure (PMO) of up to 150 PSIG and at max differential pressure, it can handle up to 690 lbs\/hr of condensate.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eDRIP, TRACING, PROCESS:\u003c\/strong\u003e IB Series inverted bucket steam traps are used in drip applications to remove condensate from steam mains and steam supply lines. For drip applications, the smaller sized units have adequate capacity. The discharge orifice of the inverted bucket trap is mounted at the top of the trap body, which makes them less susceptible to failure from dirt and debris when compared to other trap types. Since Inverted Bucket traps have poor air-handling capability, they are normally not recommended for most process applications. However, they can be used on certain process applications such as unit heaters and laundry equipment,where discharging air during system start-up is not a critical factor. F\u0026amp;T traps are the preferred choice for systems where air must be quickly discharged.\u003c\/p\u003e \u003ch2\u003eHow It Works\u003c\/h2\u003e \u003cp\u003eWhen the trap is filled with condensate, the inverted bucket inside the steam trap loses its buoyancy and rests on the bottom of the trap. This pulls the disc off the seat allowing condensate to be discharged through the seat orifice located at the top of the trap. When steam enters, it fills the inverted bucket causing the bucket to float to the surface which closes the discharge valve, containing the steam in the system. Eventually, the steam is bled off through a small hole in the top of the bucket causing it to sink, which repeats the cycle.\u003c\/p\u003e \u003ch2\u003eSelection \/ Sizing \/ Capacities\u003c\/h2\u003e \u003cp\u003e\u003cstrong\u003eSelect A Model With A Higher Maximum Operating Pressure (PMO)\u003c\/strong\u003e that Meet or Exceed the Maximum Steam Pressure or The Trap May Not Open. for Example, the Ib-1031-13-N-150 Has a Max Pmo of 150 Psi, Will Handle Capacity up To 570 Lbs\/hr at Maximum. Choose a Model that Will Handle the Capacity Requirement Based on The Differential Pressure Across the Trap. Reference Capacity Charts.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eExample:\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eApplication: 100 Lbs\/hr at 75 Psig Working Pressure and 2 Psi Differential Pressure\u003c\/li\u003e \u003cli\u003eSize\/model: Ib1031, 80 Psig, Specify Pipe Size (1\/2\", 3\/4\"), or Ib1041, 80 Psig, Specify Pipe Size (3\/4\", 1\").\u003c\/li\u003e \u003c\/ul\u003e \u003ch2\u003eOptions\u003c\/h2\u003e \u003cp\u003eStrainer and Blowdown valve connection available on 1041, 1042, 1044 \u0026amp; 1038S. We also have 3 accessories for this trap are Thermic vent to improve air handling capability. Internal check valve for superheated or condensate backflow applications.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eHow to Order Accessories:\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eCheck Valve (Suffix \u003cstrong\u003eCV\u003c\/strong\u003e) Built-in Inlet Check Valve is recommended when used on Superheated Steam\u003cbr\u003e \u003cul\u003e \u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eCV\u003c\/strong\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003cli\u003eThermic Vent (Suffix \u003cstrong\u003eTV\u003c\/strong\u003e) A Thermic Vent is recommended when using a Bucket Trap on any type of process application or where the removal of air from the system is critical.\u003cbr\u003e \u003cul\u003e \u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTV\u003c\/strong\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003cli\u003eThermic Vent \u0026amp; Check Valve (Suffix \u003cstrong\u003eTCV\u003c\/strong\u003e) For combination of Check Valve \u0026amp; Thermic Vent\u003cbr\u003e \u003cul\u003e \u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTCV\u003c\/strong\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003ch2\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e \u003cp\u003eTrap must be installed in upright position to function properly. All working components can be replaced with the trap body remaining in-line. With superheated steam, a check valve should be installed at inlet or trap may lose prime. A replacement kit containing the lever and seat assembly is a more economical option than replacing the entire steam trap. Also available are replacement screens, gaskets and buckets. When ordering replacement lever and seat assemblies, specify model and operating pressure. See Replacement Parts and Kits Section for exact cross-reference to Armstrong PCA (Pressure Change Assembly) kits.\u003c\/p\u003e \u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e \u003cdiv class=\"tech\"\u003e \u003ch2\u003eTechnical Specifications\u003c\/h2\u003e \u003cdiv class=\"specs\"\u003e \u003cdiv class=\"column\"\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eModel\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e1031\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eSizes\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e1\/2\"\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eConnections\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eNPT\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eBody Material\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eCast Iron\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eInternal check valve, Thermic vent\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003ePMO Max. Operating Pressure\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e125 PSIG\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"column\"\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eTMO Max. Operating Temperature\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e450°F\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003ePMA Max. Allowable Pressure\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e250 PSIG up to 450°F\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eTMA Max. Allowable Temperature\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e450°F @ 250 PSIG\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eIB1031-12-N-125-TCV\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e \u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap-Spec-Sheet.pdf?v=1786494449\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"Watson McDaniel","offers":[{"title":"Default Title","offer_id":44165897420878,"sku":"IB1031-12-N-125-TCV","price":631.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap__97934.1784299743.1280.1280.jpg?v=1786663368"},{"product_id":"watson-mcdaniel-ib1031-series-inverted-bucket-steam-trap-cast-iron-body-150-psig-in-line-repairability-1-2-npt","title":"Watson McDaniel IB1031 Series Inverted Bucket Steam Trap, Cast Iron Body, 150 PSIG, In-line Repairability, 1\/2\" NPT","description":"\u003ch2\u003eWatson McDaniel IB1031 Series Inverted Bucket Steam Trap - 1\/2\" NPT (150 PSIG)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWaterhammer Resistant\u003c\/li\u003e\n\u003cli\u003eSuitable for superheated steam (use internal check valve option to eliminate loss of prime)\u003c\/li\u003e\n\u003cli\u003eIn-line repairability is simplified by having all internals attached to the cover\u003c\/li\u003e\n\u003cli\u003eValve \u0026amp; seat are located at the top of the trap body making them less prone to clogging from debris and pipe scale\u003c\/li\u003e\n\u003cli\u003eAll stainless steel internals with hardened valve \u0026amp; seat\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eIB1031 Series\u003c\/h2\u003e\u003cp\u003eThe IB1031 series is the smallest of the IB series. It has a max operating pressure (PMO) of up to 150 PSIG and at max differential pressure, it can handle up to 690 lbs\/hr of condensate.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDRIP, TRACING, PROCESS:\u003c\/strong\u003e IB Series inverted bucket steam traps are used in drip applications to remove condensate from steam mains and steam supply lines. For drip applications, the smaller sized units have adequate capacity. The discharge orifice of the inverted bucket trap is mounted at the top of the trap body, which makes them less susceptible to failure from dirt and debris when compared to other trap types. Since Inverted Bucket traps have poor air-handling capability, they are normally not recommended for most process applications. However, they can be used on certain process applications such as unit heaters and laundry equipment,where discharging air during system start-up is not a critical factor. F\u0026amp;T traps are the preferred choice for systems where air must be quickly discharged.\u003c\/p\u003e\u003ch2\u003eHow It Works\u003c\/h2\u003e\u003cp\u003eWhen the trap is filled with condensate, the inverted bucket inside the steam trap loses its buoyancy and rests on the bottom of the trap. This pulls the disc off the seat allowing condensate to be discharged through the seat orifice located at the top of the trap. When steam enters, it fills the inverted bucket causing the bucket to float to the surface which closes the discharge valve, containing the steam in the system. Eventually, the steam is bled off through a small hole in the top of the bucket causing it to sink, which repeats the cycle.\u003c\/p\u003e\u003ch2\u003eSelection \/ Sizing \/ Capacities\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eSelect A Model With A Higher Maximum Operating Pressure (PMO)\u003c\/strong\u003e that Meet or Exceed the Maximum Steam Pressure or The Trap May Not Open. for Example, the Ib-1031-13-N-150 Has a Max Pmo of 150 Psi, Will Handle Capacity up To 570 Lbs\/hr at Maximum. Choose a Model that Will Handle the Capacity Requirement Based on The Differential Pressure Across the Trap. Reference Capacity Charts.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eExample:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eApplication: 100 Lbs\/hr at 75 Psig Working Pressure and 2 Psi Differential Pressure\u003c\/li\u003e\n\u003cli\u003eSize\/model: Ib1031, 80 Psig, Specify Pipe Size (1\/2\", 3\/4\"), or Ib1041, 80 Psig, Specify Pipe Size (3\/4\", 1\").\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eOptions\u003c\/h2\u003e\u003cp\u003eStrainer and Blowdown valve connection available on 1041, 1042, 1044 \u0026amp; 1038S. We also have 3 accessories for this trap are Thermic vent to improve air handling capability. Internal check valve for superheated or condensate backflow applications.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow to Order Accessories:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCheck Valve (Suffix \u003cstrong\u003eCV\u003c\/strong\u003e) Built-in Inlet Check Valve is recommended when used on Superheated Steam\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent (Suffix \u003cstrong\u003eTV\u003c\/strong\u003e) A Thermic Vent is recommended when using a Bucket Trap on any type of process application or where the removal of air from the system is critical.\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent \u0026amp; Check Valve (Suffix \u003cstrong\u003eTCV\u003c\/strong\u003e) For combination of Check Valve \u0026amp; Thermic Vent\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e\u003cp\u003eTrap must be installed in upright position to function properly. All working components can be replaced with the trap body remaining in-line. With superheated steam, a check valve should be installed at inlet or trap may lose prime. A replacement kit containing the lever and seat assembly is a more economical option than replacing the entire steam trap. Also available are replacement screens, gaskets and buckets. When ordering replacement lever and seat assemblies, specify model and operating pressure. See Replacement Parts and Kits Section for exact cross-reference to Armstrong PCA (Pressure Change Assembly) kits.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eModel\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1031\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSizes\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\"\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eConnections\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eNPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Material\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eCast Iron\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eInternal check valve, Thermic vent\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMO Max. Operating Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMO Max. Operating Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMA Max. Allowable Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 PSIG up to 450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMA Max. Allowable Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F @ 250 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap-Spec-Sheet.pdf?v=1786494449\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"Watson McDaniel","offers":[{"title":"Default Title","offer_id":44165897486414,"sku":"WM-IB1031-12-150","price":217.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap__38444.1784299743.1280.1280.jpg?v=1786663371"},{"product_id":"watson-mcdaniel-ib1031-12-n-150-inverted-bucket-steam-trap-cast-iron-body-150-psig-in-line-repairability-npt","title":"Watson McDaniel IB1031-12-N-150 Inverted Bucket Steam Trap, Cast Iron Body, 150 PSIG, In-line Repairability, NPT","description":"\u003ch2\u003eWatson McDaniel IB1031-12-N-150 Inverted Bucket Steam Trap - 1\/2\" NPT (150 PSIG)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWaterhammer Resistant\u003c\/li\u003e\n\u003cli\u003eSuitable for superheated steam (use internal check valve option to eliminate loss of prime)\u003c\/li\u003e\n\u003cli\u003eIn-line repairability is simplified by having all internals attached to the cover\u003c\/li\u003e\n\u003cli\u003eValve \u0026amp; seat are located at the top of the trap body making them less prone to clogging from debris and pipe scale\u003c\/li\u003e\n\u003cli\u003eAll stainless steel internals with hardened valve \u0026amp; seat\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eIB1031 Series\u003c\/h2\u003e\u003cp\u003eThe IB1031 series is the smallest of the IB series. It has a max operating pressure (PMO) of up to 150 PSIG and at max differential pressure, it can handle up to 690 lbs\/hr of condensate.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDRIP, TRACING, PROCESS:\u003c\/strong\u003e IB Series inverted bucket steam traps are used in drip applications to remove condensate from steam mains and steam supply lines. For drip applications, the smaller sized units have adequate capacity. The discharge orifice of the inverted bucket trap is mounted at the top of the trap body, which makes them less susceptible to failure from dirt and debris when compared to other trap types. Since Inverted Bucket traps have poor air-handling capability, they are normally not recommended for most process applications. However, they can be used on certain process applications such as unit heaters and laundry equipment,where discharging air during system start-up is not a critical factor. F\u0026amp;T traps are the preferred choice for systems where air must be quickly discharged.\u003c\/p\u003e\u003ch2\u003eHow It Works\u003c\/h2\u003e\u003cp\u003eWhen the trap is filled with condensate, the inverted bucket inside the steam trap loses its buoyancy and rests on the bottom of the trap. This pulls the disc off the seat allowing condensate to be discharged through the seat orifice located at the top of the trap. When steam enters, it fills the inverted bucket causing the bucket to float to the surface which closes the discharge valve, containing the steam in the system. Eventually, the steam is bled off through a small hole in the top of the bucket causing it to sink, which repeats the cycle.\u003c\/p\u003e\u003ch2\u003eSelection \/ Sizing \/ Capacities\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eSelect A Model With A Higher Maximum Operating Pressure (PMO)\u003c\/strong\u003e that Meet or Exceed the Maximum Steam Pressure or The Trap May Not Open. for Example, the Ib-1031-13-N-150 Has a Max Pmo of 150 Psi, Will Handle Capacity up To 570 Lbs\/hr at Maximum. Choose a Model that Will Handle the Capacity Requirement Based on The Differential Pressure Across the Trap. Reference Capacity Charts.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eExample:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eApplication: 100 Lbs\/hr at 75 Psig Working Pressure and 2 Psi Differential Pressure\u003c\/li\u003e\n\u003cli\u003eSize\/model: Ib1031, 80 Psig, Specify Pipe Size (1\/2\", 3\/4\"), or Ib1041, 80 Psig, Specify Pipe Size (3\/4\", 1\").\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eOptions\u003c\/h2\u003e\u003cp\u003eStrainer and Blowdown valve connection available on 1041, 1042, 1044 \u0026amp; 1038S. We also have 3 accessories for this trap are Thermic vent to improve air handling capability. Internal check valve for superheated or condensate backflow applications.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow to Order Accessories:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCheck Valve (Suffix \u003cstrong\u003eCV\u003c\/strong\u003e) Built-in Inlet Check Valve is recommended when used on Superheated Steam\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent (Suffix \u003cstrong\u003eTV\u003c\/strong\u003e) A Thermic Vent is recommended when using a Bucket Trap on any type of process application or where the removal of air from the system is critical.\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent \u0026amp; Check Valve (Suffix \u003cstrong\u003eTCV\u003c\/strong\u003e) For combination of Check Valve \u0026amp; Thermic Vent\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e\u003cp\u003eTrap must be installed in upright position to function properly. All working components can be replaced with the trap body remaining in-line. With superheated steam, a check valve should be installed at inlet or trap may lose prime. A replacement kit containing the lever and seat assembly is a more economical option than replacing the entire steam trap. Also available are replacement screens, gaskets and buckets. When ordering replacement lever and seat assemblies, specify model and operating pressure. See Replacement Parts and Kits Section for exact cross-reference to Armstrong PCA (Pressure Change Assembly) kits.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eModel\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1031\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSizes\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\"\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eConnections\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eNPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Material\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eCast Iron\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eInternal check valve, Thermic vent\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMO Max. Operating Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMO Max. Operating Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMA Max. Allowable Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 PSIG up to 450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMA Max. Allowable Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F @ 250 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eIB1031-12-N-150\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap-Spec-Sheet.pdf?v=1786494449\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"Watson McDaniel","offers":[{"title":"Default Title","offer_id":44165897748558,"sku":"IB1031-12-N-150","price":217.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap__33994.1784299743.1280.1280.jpg?v=1786663373"},{"product_id":"watson-mcdaniel-ib1031-12-n-150-cv-inverted-bucket-steam-trap-cast-iron-body-150-psig-in-line-repairability-npt","title":"Watson McDaniel IB1031-12-N-150-CV Inverted Bucket Steam Trap, Cast Iron Body, 150 PSIG, In-line Repairability, NPT","description":"\u003ch2\u003eWatson McDaniel IB1031-12-N-150-CV Inverted Bucket Steam Trap - 1\/2\" NPT (150 PSIG)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWaterhammer Resistant\u003c\/li\u003e\n\u003cli\u003eSuitable for superheated steam (use internal check valve option to eliminate loss of prime)\u003c\/li\u003e\n\u003cli\u003eIn-line repairability is simplified by having all internals attached to the cover\u003c\/li\u003e\n\u003cli\u003eValve \u0026amp; seat are located at the top of the trap body making them less prone to clogging from debris and pipe scale\u003c\/li\u003e\n\u003cli\u003eAll stainless steel internals with hardened valve \u0026amp; seat\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eIB1031 Series\u003c\/h2\u003e\u003cp\u003eThe IB1031 series is the smallest of the IB series. It has a max operating pressure (PMO) of up to 150 PSIG and at max differential pressure, it can handle up to 690 lbs\/hr of condensate.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDRIP, TRACING, PROCESS:\u003c\/strong\u003e IB Series inverted bucket steam traps are used in drip applications to remove condensate from steam mains and steam supply lines. For drip applications, the smaller sized units have adequate capacity. The discharge orifice of the inverted bucket trap is mounted at the top of the trap body, which makes them less susceptible to failure from dirt and debris when compared to other trap types. Since Inverted Bucket traps have poor air-handling capability, they are normally not recommended for most process applications. However, they can be used on certain process applications such as unit heaters and laundry equipment,where discharging air during system start-up is not a critical factor. F\u0026amp;T traps are the preferred choice for systems where air must be quickly discharged.\u003c\/p\u003e\u003ch2\u003eHow It Works\u003c\/h2\u003e\u003cp\u003eWhen the trap is filled with condensate, the inverted bucket inside the steam trap loses its buoyancy and rests on the bottom of the trap. This pulls the disc off the seat allowing condensate to be discharged through the seat orifice located at the top of the trap. When steam enters, it fills the inverted bucket causing the bucket to float to the surface which closes the discharge valve, containing the steam in the system. Eventually, the steam is bled off through a small hole in the top of the bucket causing it to sink, which repeats the cycle.\u003c\/p\u003e\u003ch2\u003eSelection \/ Sizing \/ Capacities\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eSelect A Model With A Higher Maximum Operating Pressure (PMO)\u003c\/strong\u003e that Meet or Exceed the Maximum Steam Pressure or The Trap May Not Open. for Example, the Ib-1031-13-N-150 Has a Max Pmo of 150 Psi, Will Handle Capacity up To 570 Lbs\/hr at Maximum. Choose a Model that Will Handle the Capacity Requirement Based on The Differential Pressure Across the Trap. Reference Capacity Charts.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eExample:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eApplication: 100 Lbs\/hr at 75 Psig Working Pressure and 2 Psi Differential Pressure\u003c\/li\u003e\n\u003cli\u003eSize\/model: Ib1031, 80 Psig, Specify Pipe Size (1\/2\", 3\/4\"), or Ib1041, 80 Psig, Specify Pipe Size (3\/4\", 1\").\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eOptions\u003c\/h2\u003e\u003cp\u003eStrainer and Blowdown valve connection available on 1041, 1042, 1044 \u0026amp; 1038S. We also have 3 accessories for this trap are Thermic vent to improve air handling capability. Internal check valve for superheated or condensate backflow applications.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow to Order Accessories:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCheck Valve (Suffix \u003cstrong\u003eCV\u003c\/strong\u003e) Built-in Inlet Check Valve is recommended when used on Superheated Steam\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent (Suffix \u003cstrong\u003eTV\u003c\/strong\u003e) A Thermic Vent is recommended when using a Bucket Trap on any type of process application or where the removal of air from the system is critical.\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent \u0026amp; Check Valve (Suffix \u003cstrong\u003eTCV\u003c\/strong\u003e) For combination of Check Valve \u0026amp; Thermic Vent\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e\u003cp\u003eTrap must be installed in upright position to function properly. All working components can be replaced with the trap body remaining in-line. With superheated steam, a check valve should be installed at inlet or trap may lose prime. A replacement kit containing the lever and seat assembly is a more economical option than replacing the entire steam trap. Also available are replacement screens, gaskets and buckets. When ordering replacement lever and seat assemblies, specify model and operating pressure. See Replacement Parts and Kits Section for exact cross-reference to Armstrong PCA (Pressure Change Assembly) kits.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eModel\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1031\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSizes\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\"\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eConnections\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eNPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Material\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eCast Iron\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eInternal check valve, Thermic vent\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMO Max. Operating Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMO Max. Operating Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMA Max. Allowable Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 PSIG up to 450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMA Max. Allowable Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F @ 250 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eIB1031-12-N-150-CV\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap-Spec-Sheet.pdf?v=1786494449\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"Watson McDaniel","offers":[{"title":"Default Title","offer_id":44165897814094,"sku":"IB1031-12-N-150-CV","price":364.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap__06922.1784299743.1280.1280.jpg?v=1786663376"},{"product_id":"watson-mcdaniel-ib1031-12-n-150-tv-inverted-bucket-steam-trap-cast-iron-body-150-psig-in-line-repairability-npt","title":"Watson McDaniel IB1031-12-N-150-TV Inverted Bucket Steam Trap, Cast Iron Body, 150 PSIG, In-line Repairability, NPT","description":"\u003ch2\u003eWatson McDaniel IB1031-12-N-150-TV Inverted Bucket Steam Trap - 1\/2\" NPT (150 PSIG)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWaterhammer Resistant\u003c\/li\u003e\n\u003cli\u003eSuitable for superheated steam (use internal check valve option to eliminate loss of prime)\u003c\/li\u003e\n\u003cli\u003eIn-line repairability is simplified by having all internals attached to the cover\u003c\/li\u003e\n\u003cli\u003eValve \u0026amp; seat are located at the top of the trap body making them less prone to clogging from debris and pipe scale\u003c\/li\u003e\n\u003cli\u003eAll stainless steel internals with hardened valve \u0026amp; seat\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eIB1031 Series\u003c\/h2\u003e\u003cp\u003eThe IB1031 series is the smallest of the IB series. It has a max operating pressure (PMO) of up to 150 PSIG and at max differential pressure, it can handle up to 690 lbs\/hr of condensate.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDRIP, TRACING, PROCESS:\u003c\/strong\u003e IB Series inverted bucket steam traps are used in drip applications to remove condensate from steam mains and steam supply lines. For drip applications, the smaller sized units have adequate capacity. The discharge orifice of the inverted bucket trap is mounted at the top of the trap body, which makes them less susceptible to failure from dirt and debris when compared to other trap types. Since Inverted Bucket traps have poor air-handling capability, they are normally not recommended for most process applications. However, they can be used on certain process applications such as unit heaters and laundry equipment,where discharging air during system start-up is not a critical factor. F\u0026amp;T traps are the preferred choice for systems where air must be quickly discharged.\u003c\/p\u003e\u003ch2\u003eHow It Works\u003c\/h2\u003e\u003cp\u003eWhen the trap is filled with condensate, the inverted bucket inside the steam trap loses its buoyancy and rests on the bottom of the trap. This pulls the disc off the seat allowing condensate to be discharged through the seat orifice located at the top of the trap. When steam enters, it fills the inverted bucket causing the bucket to float to the surface which closes the discharge valve, containing the steam in the system. Eventually, the steam is bled off through a small hole in the top of the bucket causing it to sink, which repeats the cycle.\u003c\/p\u003e\u003ch2\u003eSelection \/ Sizing \/ Capacities\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eSelect A Model With A Higher Maximum Operating Pressure (PMO)\u003c\/strong\u003e that Meet or Exceed the Maximum Steam Pressure or The Trap May Not Open. for Example, the Ib-1031-13-N-150 Has a Max Pmo of 150 Psi, Will Handle Capacity up To 570 Lbs\/hr at Maximum. Choose a Model that Will Handle the Capacity Requirement Based on The Differential Pressure Across the Trap. Reference Capacity Charts.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eExample:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eApplication: 100 Lbs\/hr at 75 Psig Working Pressure and 2 Psi Differential Pressure\u003c\/li\u003e\n\u003cli\u003eSize\/model: Ib1031, 80 Psig, Specify Pipe Size (1\/2\", 3\/4\"), or Ib1041, 80 Psig, Specify Pipe Size (3\/4\", 1\").\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eOptions\u003c\/h2\u003e\u003cp\u003eStrainer and Blowdown valve connection available on 1041, 1042, 1044 \u0026amp; 1038S. We also have 3 accessories for this trap are Thermic vent to improve air handling capability. Internal check valve for superheated or condensate backflow applications.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow to Order Accessories:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCheck Valve (Suffix \u003cstrong\u003eCV\u003c\/strong\u003e) Built-in Inlet Check Valve is recommended when used on Superheated Steam\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent (Suffix \u003cstrong\u003eTV\u003c\/strong\u003e) A Thermic Vent is recommended when using a Bucket Trap on any type of process application or where the removal of air from the system is critical.\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent \u0026amp; Check Valve (Suffix \u003cstrong\u003eTCV\u003c\/strong\u003e) For combination of Check Valve \u0026amp; Thermic Vent\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e\u003cp\u003eTrap must be installed in upright position to function properly. All working components can be replaced with the trap body remaining in-line. With superheated steam, a check valve should be installed at inlet or trap may lose prime. A replacement kit containing the lever and seat assembly is a more economical option than replacing the entire steam trap. Also available are replacement screens, gaskets and buckets. When ordering replacement lever and seat assemblies, specify model and operating pressure. See Replacement Parts and Kits Section for exact cross-reference to Armstrong PCA (Pressure Change Assembly) kits.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eModel\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1031\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSizes\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\"\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eConnections\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eNPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Material\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eCast Iron\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eInternal check valve, Thermic vent\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMO Max. Operating Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMO Max. Operating Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMA Max. Allowable Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 PSIG up to 450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMA Max. Allowable Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F @ 250 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eIB1031-12-N-150-TV\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap-Spec-Sheet.pdf?v=1786494449\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"Watson McDaniel","offers":[{"title":"Default Title","offer_id":44165897912398,"sku":"IB1031-12-N-150-TV","price":435.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap__86214.1784299743.1280.1280.jpg?v=1786663378"},{"product_id":"watson-mcdaniel-ib1031-12-n-150-tcv-inverted-bucket-steam-trap-cast-iron-body-150-psig-in-line-repairability-npt","title":"Watson McDaniel IB1031-12-N-150-TCV Inverted Bucket Steam Trap, Cast Iron Body, 150 PSIG, In-line Repairability, NPT","description":"\u003ch2\u003eWatson McDaniel IB1031-12-N-150-TCV Inverted Bucket Steam Trap - 1\/2\" NPT (150 PSIG)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWaterhammer Resistant\u003c\/li\u003e\n\u003cli\u003eSuitable for superheated steam (use internal check valve option to eliminate loss of prime)\u003c\/li\u003e\n\u003cli\u003eIn-line repairability is simplified by having all internals attached to the cover\u003c\/li\u003e\n\u003cli\u003eValve \u0026amp; seat are located at the top of the trap body making them less prone to clogging from debris and pipe scale\u003c\/li\u003e\n\u003cli\u003eAll stainless steel internals with hardened valve \u0026amp; seat\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eIB1031 Series\u003c\/h2\u003e\u003cp\u003eThe IB1031 series is the smallest of the IB series. It has a max operating pressure (PMO) of up to 150 PSIG and at max differential pressure, it can handle up to 690 lbs\/hr of condensate.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDRIP, TRACING, PROCESS:\u003c\/strong\u003e IB Series inverted bucket steam traps are used in drip applications to remove condensate from steam mains and steam supply lines. For drip applications, the smaller sized units have adequate capacity. The discharge orifice of the inverted bucket trap is mounted at the top of the trap body, which makes them less susceptible to failure from dirt and debris when compared to other trap types. Since Inverted Bucket traps have poor air-handling capability, they are normally not recommended for most process applications. However, they can be used on certain process applications such as unit heaters and laundry equipment,where discharging air during system start-up is not a critical factor. F\u0026amp;T traps are the preferred choice for systems where air must be quickly discharged.\u003c\/p\u003e\u003ch2\u003eHow It Works\u003c\/h2\u003e\u003cp\u003eWhen the trap is filled with condensate, the inverted bucket inside the steam trap loses its buoyancy and rests on the bottom of the trap. This pulls the disc off the seat allowing condensate to be discharged through the seat orifice located at the top of the trap. When steam enters, it fills the inverted bucket causing the bucket to float to the surface which closes the discharge valve, containing the steam in the system. Eventually, the steam is bled off through a small hole in the top of the bucket causing it to sink, which repeats the cycle.\u003c\/p\u003e\u003ch2\u003eSelection \/ Sizing \/ Capacities\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eSelect A Model With A Higher Maximum Operating Pressure (PMO)\u003c\/strong\u003e that Meet or Exceed the Maximum Steam Pressure or The Trap May Not Open. for Example, the Ib-1031-13-N-150 Has a Max Pmo of 150 Psi, Will Handle Capacity up To 570 Lbs\/hr at Maximum. Choose a Model that Will Handle the Capacity Requirement Based on The Differential Pressure Across the Trap. Reference Capacity Charts.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eExample:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eApplication: 100 Lbs\/hr at 75 Psig Working Pressure and 2 Psi Differential Pressure\u003c\/li\u003e\n\u003cli\u003eSize\/model: Ib1031, 80 Psig, Specify Pipe Size (1\/2\", 3\/4\"), or Ib1041, 80 Psig, Specify Pipe Size (3\/4\", 1\").\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eOptions\u003c\/h2\u003e\u003cp\u003eStrainer and Blowdown valve connection available on 1041, 1042, 1044 \u0026amp; 1038S. We also have 3 accessories for this trap are Thermic vent to improve air handling capability. Internal check valve for superheated or condensate backflow applications.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow to Order Accessories:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCheck Valve (Suffix \u003cstrong\u003eCV\u003c\/strong\u003e) Built-in Inlet Check Valve is recommended when used on Superheated Steam\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent (Suffix \u003cstrong\u003eTV\u003c\/strong\u003e) A Thermic Vent is recommended when using a Bucket Trap on any type of process application or where the removal of air from the system is critical.\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent \u0026amp; Check Valve (Suffix \u003cstrong\u003eTCV\u003c\/strong\u003e) For combination of Check Valve \u0026amp; Thermic Vent\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e\u003cp\u003eTrap must be installed in upright position to function properly. All working components can be replaced with the trap body remaining in-line. With superheated steam, a check valve should be installed at inlet or trap may lose prime. A replacement kit containing the lever and seat assembly is a more economical option than replacing the entire steam trap. Also available are replacement screens, gaskets and buckets. When ordering replacement lever and seat assemblies, specify model and operating pressure. See Replacement Parts and Kits Section for exact cross-reference to Armstrong PCA (Pressure Change Assembly) kits.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eModel\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1031\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSizes\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\"\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eConnections\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eNPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Material\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eCast Iron\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eInternal check valve, Thermic vent\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMO Max. Operating Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMO Max. Operating Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMA Max. Allowable Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 PSIG up to 450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMA Max. Allowable Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F @ 250 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eIB1031-12-N-150-TCV\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap-Spec-Sheet.pdf?v=1786494449\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"Watson McDaniel","offers":[{"title":"Default Title","offer_id":44165897977934,"sku":"IB1031-12-N-150-TCV","price":631.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap__41041.1784299743.1280.1280.jpg?v=1786663380"},{"product_id":"watson-mcdaniel-ib1031-series-inverted-bucket-steam-trap-cast-iron-body-20-psig-in-line-repairability-1-2-npt","title":"Watson McDaniel IB1031 Series Inverted Bucket Steam Trap, Cast Iron Body, 20 PSIG, In-line Repairability, 1\/2\" NPT","description":"\u003ch2\u003eWatson McDaniel IB1031 Series Inverted Bucket Steam Trap - 1\/2\" NPT (20 PSIG)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWaterhammer Resistant\u003c\/li\u003e\n\u003cli\u003eSuitable for superheated steam (use internal check valve option to eliminate loss of prime)\u003c\/li\u003e\n\u003cli\u003eIn-line repairability is simplified by having all internals attached to the cover\u003c\/li\u003e\n\u003cli\u003eValve \u0026amp; seat are located at the top of the trap body making them less prone to clogging from debris and pipe scale\u003c\/li\u003e\n\u003cli\u003eAll stainless steel internals with hardened valve \u0026amp; seat\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eIB1031 Series\u003c\/h2\u003e\u003cp\u003eThe IB1031 series is the smallest of the IB series. It has a max operating pressure (PMO) of up to 150 PSIG and at max differential pressure, it can handle up to 690 lbs\/hr of condensate.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDRIP, TRACING, PROCESS:\u003c\/strong\u003e IB Series inverted bucket steam traps are used in drip applications to remove condensate from steam mains and steam supply lines. For drip applications, the smaller sized units have adequate capacity. The discharge orifice of the inverted bucket trap is mounted at the top of the trap body, which makes them less susceptible to failure from dirt and debris when compared to other trap types. Since Inverted Bucket traps have poor air-handling capability, they are normally not recommended for most process applications. However, they can be used on certain process applications such as unit heaters and laundry equipment,where discharging air during system start-up is not a critical factor. F\u0026amp;T traps are the preferred choice for systems where air must be quickly discharged.\u003c\/p\u003e\u003ch2\u003eHow It Works\u003c\/h2\u003e\u003cp\u003eWhen the trap is filled with condensate, the inverted bucket inside the steam trap loses its buoyancy and rests on the bottom of the trap. This pulls the disc off the seat allowing condensate to be discharged through the seat orifice located at the top of the trap. When steam enters, it fills the inverted bucket causing the bucket to float to the surface which closes the discharge valve, containing the steam in the system. Eventually, the steam is bled off through a small hole in the top of the bucket causing it to sink, which repeats the cycle.\u003c\/p\u003e\u003ch2\u003eSelection \/ Sizing \/ Capacities\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eSelect A Model With A Higher Maximum Operating Pressure (PMO)\u003c\/strong\u003e that Meet or Exceed the Maximum Steam Pressure or The Trap May Not Open. for Example, the Ib-1031-13-N-150 Has a Max Pmo of 150 Psi, Will Handle Capacity up To 570 Lbs\/hr at Maximum. Choose a Model that Will Handle the Capacity Requirement Based on The Differential Pressure Across the Trap. Reference Capacity Charts.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eExample:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eApplication: 100 Lbs\/hr at 75 Psig Working Pressure and 2 Psi Differential Pressure\u003c\/li\u003e\n\u003cli\u003eSize\/model: Ib1031, 80 Psig, Specify Pipe Size (1\/2\", 3\/4\"), or Ib1041, 80 Psig, Specify Pipe Size (3\/4\", 1\").\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eOptions\u003c\/h2\u003e\u003cp\u003eStrainer and Blowdown valve connection available on 1041, 1042, 1044 \u0026amp; 1038S. We also have 3 accessories for this trap are Thermic vent to improve air handling capability. Internal check valve for superheated or condensate backflow applications.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow to Order Accessories:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCheck Valve (Suffix \u003cstrong\u003eCV\u003c\/strong\u003e) Built-in Inlet Check Valve is recommended when used on Superheated Steam\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent (Suffix \u003cstrong\u003eTV\u003c\/strong\u003e) A Thermic Vent is recommended when using a Bucket Trap on any type of process application or where the removal of air from the system is critical.\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent \u0026amp; Check Valve (Suffix \u003cstrong\u003eTCV\u003c\/strong\u003e) For combination of Check Valve \u0026amp; Thermic Vent\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e\u003cp\u003eTrap must be installed in upright position to function properly. All working components can be replaced with the trap body remaining in-line. With superheated steam, a check valve should be installed at inlet or trap may lose prime. A replacement kit containing the lever and seat assembly is a more economical option than replacing the entire steam trap. Also available are replacement screens, gaskets and buckets. When ordering replacement lever and seat assemblies, specify model and operating pressure. See Replacement Parts and Kits Section for exact cross-reference to Armstrong PCA (Pressure Change Assembly) kits.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eModel\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1031\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSizes\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\"\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eConnections\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eNPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Material\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eCast Iron\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eInternal check valve, Thermic vent\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMO Max. Operating Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e20 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMO Max. Operating Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMA Max. Allowable Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 PSIG up to 450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMA Max. Allowable Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F @ 250 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap-Spec-Sheet.pdf?v=1786494449\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"Watson McDaniel","offers":[{"title":"Default Title","offer_id":44165898109006,"sku":"WM-IB1031-12-020","price":217.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap__66415.1784299743.1280.1280.jpg?v=1786663385"},{"product_id":"watson-mcdaniel-ib1031-12-n-020-inverted-bucket-steam-trap-cast-iron-body-20-psig-in-line-repairability-npt","title":"Watson McDaniel IB1031-12-N-020 Inverted Bucket Steam Trap, Cast Iron Body, 20 PSIG, In-line Repairability, NPT","description":"\u003ch2\u003eWatson McDaniel IB1031-12-N-020 Inverted Bucket Steam Trap - 1\/2\" NPT (20 PSIG)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWaterhammer Resistant\u003c\/li\u003e\n\u003cli\u003eSuitable for superheated steam (use internal check valve option to eliminate loss of prime)\u003c\/li\u003e\n\u003cli\u003eIn-line repairability is simplified by having all internals attached to the cover\u003c\/li\u003e\n\u003cli\u003eValve \u0026amp; seat are located at the top of the trap body making them less prone to clogging from debris and pipe scale\u003c\/li\u003e\n\u003cli\u003eAll stainless steel internals with hardened valve \u0026amp; seat\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eIB1031 Series\u003c\/h2\u003e\u003cp\u003eThe IB1031 series is the smallest of the IB series. It has a max operating pressure (PMO) of up to 150 PSIG and at max differential pressure, it can handle up to 690 lbs\/hr of condensate.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDRIP, TRACING, PROCESS:\u003c\/strong\u003e IB Series inverted bucket steam traps are used in drip applications to remove condensate from steam mains and steam supply lines. For drip applications, the smaller sized units have adequate capacity. The discharge orifice of the inverted bucket trap is mounted at the top of the trap body, which makes them less susceptible to failure from dirt and debris when compared to other trap types. Since Inverted Bucket traps have poor air-handling capability, they are normally not recommended for most process applications. However, they can be used on certain process applications such as unit heaters and laundry equipment,where discharging air during system start-up is not a critical factor. F\u0026amp;T traps are the preferred choice for systems where air must be quickly discharged.\u003c\/p\u003e\u003ch2\u003eHow It Works\u003c\/h2\u003e\u003cp\u003eWhen the trap is filled with condensate, the inverted bucket inside the steam trap loses its buoyancy and rests on the bottom of the trap. This pulls the disc off the seat allowing condensate to be discharged through the seat orifice located at the top of the trap. When steam enters, it fills the inverted bucket causing the bucket to float to the surface which closes the discharge valve, containing the steam in the system. Eventually, the steam is bled off through a small hole in the top of the bucket causing it to sink, which repeats the cycle.\u003c\/p\u003e\u003ch2\u003eSelection \/ Sizing \/ Capacities\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eSelect A Model With A Higher Maximum Operating Pressure (PMO)\u003c\/strong\u003e that Meet or Exceed the Maximum Steam Pressure or The Trap May Not Open. for Example, the Ib-1031-13-N-150 Has a Max Pmo of 150 Psi, Will Handle Capacity up To 570 Lbs\/hr at Maximum. Choose a Model that Will Handle the Capacity Requirement Based on The Differential Pressure Across the Trap. Reference Capacity Charts.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eExample:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eApplication: 100 Lbs\/hr at 75 Psig Working Pressure and 2 Psi Differential Pressure\u003c\/li\u003e\n\u003cli\u003eSize\/model: Ib1031, 80 Psig, Specify Pipe Size (1\/2\", 3\/4\"), or Ib1041, 80 Psig, Specify Pipe Size (3\/4\", 1\").\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eOptions\u003c\/h2\u003e\u003cp\u003eStrainer and Blowdown valve connection available on 1041, 1042, 1044 \u0026amp; 1038S. We also have 3 accessories for this trap are Thermic vent to improve air handling capability. Internal check valve for superheated or condensate backflow applications.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow to Order Accessories:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCheck Valve (Suffix \u003cstrong\u003eCV\u003c\/strong\u003e) Built-in Inlet Check Valve is recommended when used on Superheated Steam\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent (Suffix \u003cstrong\u003eTV\u003c\/strong\u003e) A Thermic Vent is recommended when using a Bucket Trap on any type of process application or where the removal of air from the system is critical.\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent \u0026amp; Check Valve (Suffix \u003cstrong\u003eTCV\u003c\/strong\u003e) For combination of Check Valve \u0026amp; Thermic Vent\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e\u003cp\u003eTrap must be installed in upright position to function properly. All working components can be replaced with the trap body remaining in-line. With superheated steam, a check valve should be installed at inlet or trap may lose prime. A replacement kit containing the lever and seat assembly is a more economical option than replacing the entire steam trap. Also available are replacement screens, gaskets and buckets. When ordering replacement lever and seat assemblies, specify model and operating pressure. See Replacement Parts and Kits Section for exact cross-reference to Armstrong PCA (Pressure Change Assembly) kits.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eModel\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1031\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSizes\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\"\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eConnections\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eNPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Material\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eCast Iron\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eInternal check valve, Thermic vent\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMO Max. Operating Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e20 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMO Max. Operating Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMA Max. Allowable Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 PSIG up to 450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMA Max. Allowable Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F @ 250 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eIB1031-12-N-020\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap-Spec-Sheet.pdf?v=1786494449\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"Watson McDaniel","offers":[{"title":"Default Title","offer_id":44165898174542,"sku":"IB1031-12-N-020","price":217.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap__91179.1784299743.1280.1280.jpg?v=1786663387"},{"product_id":"watson-mcdaniel-ib1031-12-n-020-cv-inverted-bucket-steam-trap-cast-iron-body-20-psig-in-line-repairability-npt","title":"Watson McDaniel IB1031-12-N-020-CV Inverted Bucket Steam Trap, Cast Iron Body, 20 PSIG, In-line Repairability, NPT","description":"\u003ch2\u003eWatson McDaniel IB1031-12-N-020-CV Inverted Bucket Steam Trap - 1\/2\" NPT (20 PSIG)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWaterhammer Resistant\u003c\/li\u003e\n\u003cli\u003eSuitable for superheated steam (use internal check valve option to eliminate loss of prime)\u003c\/li\u003e\n\u003cli\u003eIn-line repairability is simplified by having all internals attached to the cover\u003c\/li\u003e\n\u003cli\u003eValve \u0026amp; seat are located at the top of the trap body making them less prone to clogging from debris and pipe scale\u003c\/li\u003e\n\u003cli\u003eAll stainless steel internals with hardened valve \u0026amp; seat\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eIB1031 Series\u003c\/h2\u003e\u003cp\u003eThe IB1031 series is the smallest of the IB series. It has a max operating pressure (PMO) of up to 150 PSIG and at max differential pressure, it can handle up to 690 lbs\/hr of condensate.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDRIP, TRACING, PROCESS:\u003c\/strong\u003e IB Series inverted bucket steam traps are used in drip applications to remove condensate from steam mains and steam supply lines. For drip applications, the smaller sized units have adequate capacity. The discharge orifice of the inverted bucket trap is mounted at the top of the trap body, which makes them less susceptible to failure from dirt and debris when compared to other trap types. Since Inverted Bucket traps have poor air-handling capability, they are normally not recommended for most process applications. However, they can be used on certain process applications such as unit heaters and laundry equipment,where discharging air during system start-up is not a critical factor. F\u0026amp;T traps are the preferred choice for systems where air must be quickly discharged.\u003c\/p\u003e\u003ch2\u003eHow It Works\u003c\/h2\u003e\u003cp\u003eWhen the trap is filled with condensate, the inverted bucket inside the steam trap loses its buoyancy and rests on the bottom of the trap. This pulls the disc off the seat allowing condensate to be discharged through the seat orifice located at the top of the trap. When steam enters, it fills the inverted bucket causing the bucket to float to the surface which closes the discharge valve, containing the steam in the system. Eventually, the steam is bled off through a small hole in the top of the bucket causing it to sink, which repeats the cycle.\u003c\/p\u003e\u003ch2\u003eSelection \/ Sizing \/ Capacities\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eSelect A Model With A Higher Maximum Operating Pressure (PMO)\u003c\/strong\u003e that Meet or Exceed the Maximum Steam Pressure or The Trap May Not Open. for Example, the Ib-1031-13-N-150 Has a Max Pmo of 150 Psi, Will Handle Capacity up To 570 Lbs\/hr at Maximum. Choose a Model that Will Handle the Capacity Requirement Based on The Differential Pressure Across the Trap. Reference Capacity Charts.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eExample:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eApplication: 100 Lbs\/hr at 75 Psig Working Pressure and 2 Psi Differential Pressure\u003c\/li\u003e\n\u003cli\u003eSize\/model: Ib1031, 80 Psig, Specify Pipe Size (1\/2\", 3\/4\"), or Ib1041, 80 Psig, Specify Pipe Size (3\/4\", 1\").\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eOptions\u003c\/h2\u003e\u003cp\u003eStrainer and Blowdown valve connection available on 1041, 1042, 1044 \u0026amp; 1038S. We also have 3 accessories for this trap are Thermic vent to improve air handling capability. Internal check valve for superheated or condensate backflow applications.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow to Order Accessories:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCheck Valve (Suffix \u003cstrong\u003eCV\u003c\/strong\u003e) Built-in Inlet Check Valve is recommended when used on Superheated Steam\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent (Suffix \u003cstrong\u003eTV\u003c\/strong\u003e) A Thermic Vent is recommended when using a Bucket Trap on any type of process application or where the removal of air from the system is critical.\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent \u0026amp; Check Valve (Suffix \u003cstrong\u003eTCV\u003c\/strong\u003e) For combination of Check Valve \u0026amp; Thermic Vent\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e\u003cp\u003eTrap must be installed in upright position to function properly. All working components can be replaced with the trap body remaining in-line. With superheated steam, a check valve should be installed at inlet or trap may lose prime. A replacement kit containing the lever and seat assembly is a more economical option than replacing the entire steam trap. Also available are replacement screens, gaskets and buckets. When ordering replacement lever and seat assemblies, specify model and operating pressure. See Replacement Parts and Kits Section for exact cross-reference to Armstrong PCA (Pressure Change Assembly) kits.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eModel\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1031\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSizes\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\"\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eConnections\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eNPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Material\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eCast Iron\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eInternal check valve, Thermic vent\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMO Max. Operating Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e20 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMO Max. Operating Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMA Max. Allowable Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 PSIG up to 450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMA Max. Allowable Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F @ 250 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eIB1031-12-N-020-CV\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap-Spec-Sheet.pdf?v=1786494449\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"Watson McDaniel","offers":[{"title":"Default Title","offer_id":44165898502222,"sku":"IB1031-12-N-020-CV","price":364.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap__17019.1784299743.1280.1280.jpg?v=1786663390"},{"product_id":"watson-mcdaniel-ib1031-12-n-020-tv-inverted-bucket-steam-trap-cast-iron-body-20-psig-in-line-repairability-npt","title":"Watson McDaniel IB1031-12-N-020-TV Inverted Bucket Steam Trap, Cast Iron Body, 20 PSIG, In-line Repairability, NPT","description":"\u003ch2\u003eWatson McDaniel IB1031-12-N-020-TV Inverted Bucket Steam Trap - 1\/2\" NPT (20 PSIG)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWaterhammer Resistant\u003c\/li\u003e\n\u003cli\u003eSuitable for superheated steam (use internal check valve option to eliminate loss of prime)\u003c\/li\u003e\n\u003cli\u003eIn-line repairability is simplified by having all internals attached to the cover\u003c\/li\u003e\n\u003cli\u003eValve \u0026amp; seat are located at the top of the trap body making them less prone to clogging from debris and pipe scale\u003c\/li\u003e\n\u003cli\u003eAll stainless steel internals with hardened valve \u0026amp; seat\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eIB1031 Series\u003c\/h2\u003e\u003cp\u003eThe IB1031 series is the smallest of the IB series. It has a max operating pressure (PMO) of up to 150 PSIG and at max differential pressure, it can handle up to 690 lbs\/hr of condensate.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDRIP, TRACING, PROCESS:\u003c\/strong\u003e IB Series inverted bucket steam traps are used in drip applications to remove condensate from steam mains and steam supply lines. For drip applications, the smaller sized units have adequate capacity. The discharge orifice of the inverted bucket trap is mounted at the top of the trap body, which makes them less susceptible to failure from dirt and debris when compared to other trap types. Since Inverted Bucket traps have poor air-handling capability, they are normally not recommended for most process applications. However, they can be used on certain process applications such as unit heaters and laundry equipment,where discharging air during system start-up is not a critical factor. F\u0026amp;T traps are the preferred choice for systems where air must be quickly discharged.\u003c\/p\u003e\u003ch2\u003eHow It Works\u003c\/h2\u003e\u003cp\u003eWhen the trap is filled with condensate, the inverted bucket inside the steam trap loses its buoyancy and rests on the bottom of the trap. This pulls the disc off the seat allowing condensate to be discharged through the seat orifice located at the top of the trap. When steam enters, it fills the inverted bucket causing the bucket to float to the surface which closes the discharge valve, containing the steam in the system. Eventually, the steam is bled off through a small hole in the top of the bucket causing it to sink, which repeats the cycle.\u003c\/p\u003e\u003ch2\u003eSelection \/ Sizing \/ Capacities\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eSelect A Model With A Higher Maximum Operating Pressure (PMO)\u003c\/strong\u003e that Meet or Exceed the Maximum Steam Pressure or The Trap May Not Open. for Example, the Ib-1031-13-N-150 Has a Max Pmo of 150 Psi, Will Handle Capacity up To 570 Lbs\/hr at Maximum. Choose a Model that Will Handle the Capacity Requirement Based on The Differential Pressure Across the Trap. Reference Capacity Charts.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eExample:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eApplication: 100 Lbs\/hr at 75 Psig Working Pressure and 2 Psi Differential Pressure\u003c\/li\u003e\n\u003cli\u003eSize\/model: Ib1031, 80 Psig, Specify Pipe Size (1\/2\", 3\/4\"), or Ib1041, 80 Psig, Specify Pipe Size (3\/4\", 1\").\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eOptions\u003c\/h2\u003e\u003cp\u003eStrainer and Blowdown valve connection available on 1041, 1042, 1044 \u0026amp; 1038S. We also have 3 accessories for this trap are Thermic vent to improve air handling capability. Internal check valve for superheated or condensate backflow applications.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow to Order Accessories:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCheck Valve (Suffix \u003cstrong\u003eCV\u003c\/strong\u003e) Built-in Inlet Check Valve is recommended when used on Superheated Steam\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent (Suffix \u003cstrong\u003eTV\u003c\/strong\u003e) A Thermic Vent is recommended when using a Bucket Trap on any type of process application or where the removal of air from the system is critical.\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent \u0026amp; Check Valve (Suffix \u003cstrong\u003eTCV\u003c\/strong\u003e) For combination of Check Valve \u0026amp; Thermic Vent\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e\u003cp\u003eTrap must be installed in upright position to function properly. All working components can be replaced with the trap body remaining in-line. With superheated steam, a check valve should be installed at inlet or trap may lose prime. A replacement kit containing the lever and seat assembly is a more economical option than replacing the entire steam trap. Also available are replacement screens, gaskets and buckets. When ordering replacement lever and seat assemblies, specify model and operating pressure. See Replacement Parts and Kits Section for exact cross-reference to Armstrong PCA (Pressure Change Assembly) kits.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eModel\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1031\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSizes\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\"\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eConnections\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eNPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Material\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eCast Iron\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eInternal check valve, Thermic vent\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMO Max. Operating Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e20 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMO Max. Operating Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMA Max. Allowable Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 PSIG up to 450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMA Max. Allowable Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F @ 250 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eIB1031-12-N-020-TV\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap-Spec-Sheet.pdf?v=1786494449\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"Watson McDaniel","offers":[{"title":"Default Title","offer_id":44165898567758,"sku":"IB1031-12-N-020-TV","price":435.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap__95316.1784299743.1280.1280.jpg?v=1786663392"},{"product_id":"watson-mcdaniel-ib1031-12-n-020-tcv-inverted-bucket-steam-trap-cast-iron-body-20-psig-in-line-repairability-npt","title":"Watson McDaniel IB1031-12-N-020-TCV Inverted Bucket Steam Trap, Cast Iron Body, 20 PSIG, In-line Repairability, NPT","description":"\u003ch2\u003eWatson McDaniel IB1031-12-N-020-TCV Inverted Bucket Steam Trap - 1\/2\" NPT (20 PSIG)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWaterhammer Resistant\u003c\/li\u003e\n\u003cli\u003eSuitable for superheated steam (use internal check valve option to eliminate loss of prime)\u003c\/li\u003e\n\u003cli\u003eIn-line repairability is simplified by having all internals attached to the cover\u003c\/li\u003e\n\u003cli\u003eValve \u0026amp; seat are located at the top of the trap body making them less prone to clogging from debris and pipe scale\u003c\/li\u003e\n\u003cli\u003eAll stainless steel internals with hardened valve \u0026amp; seat\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eIB1031 Series\u003c\/h2\u003e\u003cp\u003eThe IB1031 series is the smallest of the IB series. It has a max operating pressure (PMO) of up to 150 PSIG and at max differential pressure, it can handle up to 690 lbs\/hr of condensate.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDRIP, TRACING, PROCESS:\u003c\/strong\u003e IB Series inverted bucket steam traps are used in drip applications to remove condensate from steam mains and steam supply lines. For drip applications, the smaller sized units have adequate capacity. The discharge orifice of the inverted bucket trap is mounted at the top of the trap body, which makes them less susceptible to failure from dirt and debris when compared to other trap types. Since Inverted Bucket traps have poor air-handling capability, they are normally not recommended for most process applications. However, they can be used on certain process applications such as unit heaters and laundry equipment,where discharging air during system start-up is not a critical factor. F\u0026amp;T traps are the preferred choice for systems where air must be quickly discharged.\u003c\/p\u003e\u003ch2\u003eHow It Works\u003c\/h2\u003e\u003cp\u003eWhen the trap is filled with condensate, the inverted bucket inside the steam trap loses its buoyancy and rests on the bottom of the trap. This pulls the disc off the seat allowing condensate to be discharged through the seat orifice located at the top of the trap. When steam enters, it fills the inverted bucket causing the bucket to float to the surface which closes the discharge valve, containing the steam in the system. Eventually, the steam is bled off through a small hole in the top of the bucket causing it to sink, which repeats the cycle.\u003c\/p\u003e\u003ch2\u003eSelection \/ Sizing \/ Capacities\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eSelect A Model With A Higher Maximum Operating Pressure (PMO)\u003c\/strong\u003e that Meet or Exceed the Maximum Steam Pressure or The Trap May Not Open. for Example, the Ib-1031-13-N-150 Has a Max Pmo of 150 Psi, Will Handle Capacity up To 570 Lbs\/hr at Maximum. Choose a Model that Will Handle the Capacity Requirement Based on The Differential Pressure Across the Trap. Reference Capacity Charts.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eExample:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eApplication: 100 Lbs\/hr at 75 Psig Working Pressure and 2 Psi Differential Pressure\u003c\/li\u003e\n\u003cli\u003eSize\/model: Ib1031, 80 Psig, Specify Pipe Size (1\/2\", 3\/4\"), or Ib1041, 80 Psig, Specify Pipe Size (3\/4\", 1\").\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eOptions\u003c\/h2\u003e\u003cp\u003eStrainer and Blowdown valve connection available on 1041, 1042, 1044 \u0026amp; 1038S. We also have 3 accessories for this trap are Thermic vent to improve air handling capability. Internal check valve for superheated or condensate backflow applications.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow to Order Accessories:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCheck Valve (Suffix \u003cstrong\u003eCV\u003c\/strong\u003e) Built-in Inlet Check Valve is recommended when used on Superheated Steam\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent (Suffix \u003cstrong\u003eTV\u003c\/strong\u003e) A Thermic Vent is recommended when using a Bucket Trap on any type of process application or where the removal of air from the system is critical.\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent \u0026amp; Check Valve (Suffix \u003cstrong\u003eTCV\u003c\/strong\u003e) For combination of Check Valve \u0026amp; Thermic Vent\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e\u003cp\u003eTrap must be installed in upright position to function properly. All working components can be replaced with the trap body remaining in-line. With superheated steam, a check valve should be installed at inlet or trap may lose prime. A replacement kit containing the lever and seat assembly is a more economical option than replacing the entire steam trap. Also available are replacement screens, gaskets and buckets. When ordering replacement lever and seat assemblies, specify model and operating pressure. See Replacement Parts and Kits Section for exact cross-reference to Armstrong PCA (Pressure Change Assembly) kits.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eModel\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1031\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSizes\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\"\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eConnections\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eNPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Material\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eCast Iron\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eInternal check valve, Thermic vent\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMO Max. Operating Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e20 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMO Max. Operating Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMA Max. Allowable Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 PSIG up to 450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMA Max. Allowable Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F @ 250 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eIB1031-12-N-020-TCV\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap-Spec-Sheet.pdf?v=1786494449\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"Watson McDaniel","offers":[{"title":"Default Title","offer_id":44165898633294,"sku":"IB1031-12-N-020-TCV","price":631.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap__83606.1784299743.1280.1280.jpg?v=1786663395"},{"product_id":"watson-mcdaniel-ib1031-series-inverted-bucket-steam-trap-cast-iron-body-80-psig-in-line-repairability-1-2-npt","title":"Watson McDaniel IB1031 Series Inverted Bucket Steam Trap, Cast Iron Body, 80 PSIG, In-line Repairability, 1\/2\" NPT","description":"\u003ch2\u003eWatson McDaniel IB1031 Series Inverted Bucket Steam Trap - 1\/2\" NPT (80 PSIG)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWaterhammer Resistant\u003c\/li\u003e\n\u003cli\u003eSuitable for superheated steam (use internal check valve option to eliminate loss of prime)\u003c\/li\u003e\n\u003cli\u003eIn-line repairability is simplified by having all internals attached to the cover\u003c\/li\u003e\n\u003cli\u003eValve \u0026amp; seat are located at the top of the trap body making them less prone to clogging from debris and pipe scale\u003c\/li\u003e\n\u003cli\u003eAll stainless steel internals with hardened valve \u0026amp; seat\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eIB1031 Series\u003c\/h2\u003e\u003cp\u003eThe IB1031 series is the smallest of the IB series. It has a max operating pressure (PMO) of up to 150 PSIG and at max differential pressure, it can handle up to 690 lbs\/hr of condensate.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDRIP, TRACING, PROCESS:\u003c\/strong\u003e IB Series inverted bucket steam traps are used in drip applications to remove condensate from steam mains and steam supply lines. For drip applications, the smaller sized units have adequate capacity. The discharge orifice of the inverted bucket trap is mounted at the top of the trap body, which makes them less susceptible to failure from dirt and debris when compared to other trap types. Since Inverted Bucket traps have poor air-handling capability, they are normally not recommended for most process applications. However, they can be used on certain process applications such as unit heaters and laundry equipment,where discharging air during system start-up is not a critical factor. F\u0026amp;T traps are the preferred choice for systems where air must be quickly discharged.\u003c\/p\u003e\u003ch2\u003eHow It Works\u003c\/h2\u003e\u003cp\u003eWhen the trap is filled with condensate, the inverted bucket inside the steam trap loses its buoyancy and rests on the bottom of the trap. This pulls the disc off the seat allowing condensate to be discharged through the seat orifice located at the top of the trap. When steam enters, it fills the inverted bucket causing the bucket to float to the surface which closes the discharge valve, containing the steam in the system. Eventually, the steam is bled off through a small hole in the top of the bucket causing it to sink, which repeats the cycle.\u003c\/p\u003e\u003ch2\u003eSelection \/ Sizing \/ Capacities\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eSelect A Model With A Higher Maximum Operating Pressure (PMO)\u003c\/strong\u003e that Meet or Exceed the Maximum Steam Pressure or The Trap May Not Open. for Example, the Ib-1031-13-N-150 Has a Max Pmo of 150 Psi, Will Handle Capacity up To 570 Lbs\/hr at Maximum. Choose a Model that Will Handle the Capacity Requirement Based on The Differential Pressure Across the Trap. Reference Capacity Charts.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eExample:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eApplication: 100 Lbs\/hr at 75 Psig Working Pressure and 2 Psi Differential Pressure\u003c\/li\u003e\n\u003cli\u003eSize\/model: Ib1031, 80 Psig, Specify Pipe Size (1\/2\", 3\/4\"), or Ib1041, 80 Psig, Specify Pipe Size (3\/4\", 1\").\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eOptions\u003c\/h2\u003e\u003cp\u003eStrainer and Blowdown valve connection available on 1041, 1042, 1044 \u0026amp; 1038S. We also have 3 accessories for this trap are Thermic vent to improve air handling capability. Internal check valve for superheated or condensate backflow applications.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow to Order Accessories:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCheck Valve (Suffix \u003cstrong\u003eCV\u003c\/strong\u003e) Built-in Inlet Check Valve is recommended when used on Superheated Steam\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent (Suffix \u003cstrong\u003eTV\u003c\/strong\u003e) A Thermic Vent is recommended when using a Bucket Trap on any type of process application or where the removal of air from the system is critical.\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent \u0026amp; Check Valve (Suffix \u003cstrong\u003eTCV\u003c\/strong\u003e) For combination of Check Valve \u0026amp; Thermic Vent\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e\u003cp\u003eTrap must be installed in upright position to function properly. All working components can be replaced with the trap body remaining in-line. With superheated steam, a check valve should be installed at inlet or trap may lose prime. A replacement kit containing the lever and seat assembly is a more economical option than replacing the entire steam trap. Also available are replacement screens, gaskets and buckets. When ordering replacement lever and seat assemblies, specify model and operating pressure. See Replacement Parts and Kits Section for exact cross-reference to Armstrong PCA (Pressure Change Assembly) kits.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eModel\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1031\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSizes\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\"\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eConnections\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eNPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Material\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eCast Iron\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eInternal check valve, Thermic vent\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMO Max. Operating Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e80 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMO Max. Operating Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMA Max. Allowable Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 PSIG up to 450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMA Max. Allowable Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F @ 250 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap-Spec-Sheet.pdf?v=1786494449\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"Watson McDaniel","offers":[{"title":"Default Title","offer_id":44165898698830,"sku":"WM-IB1031-12-080","price":217.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap__88128.1784299720.1280.1280.jpg?v=1786663397"},{"product_id":"watson-mcdaniel-ib1031-12-n-080-inverted-bucket-steam-trap-cast-iron-body-80-psig-in-line-repairability-npt","title":"Watson McDaniel IB1031-12-N-080 Inverted Bucket Steam Trap, Cast Iron Body, 80 PSIG, In-line Repairability, NPT","description":"\u003ch2\u003eWatson McDaniel IB1031-12-N-080 Inverted Bucket Steam Trap - 1\/2\" NPT (80 PSIG)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWaterhammer Resistant\u003c\/li\u003e\n\u003cli\u003eSuitable for superheated steam (use internal check valve option to eliminate loss of prime)\u003c\/li\u003e\n\u003cli\u003eIn-line repairability is simplified by having all internals attached to the cover\u003c\/li\u003e\n\u003cli\u003eValve \u0026amp; seat are located at the top of the trap body making them less prone to clogging from debris and pipe scale\u003c\/li\u003e\n\u003cli\u003eAll stainless steel internals with hardened valve \u0026amp; seat\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eIB1031 Series\u003c\/h2\u003e\u003cp\u003eThe IB1031 series is the smallest of the IB series. It has a max operating pressure (PMO) of up to 150 PSIG and at max differential pressure, it can handle up to 690 lbs\/hr of condensate.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDRIP, TRACING, PROCESS:\u003c\/strong\u003e IB Series inverted bucket steam traps are used in drip applications to remove condensate from steam mains and steam supply lines. For drip applications, the smaller sized units have adequate capacity. The discharge orifice of the inverted bucket trap is mounted at the top of the trap body, which makes them less susceptible to failure from dirt and debris when compared to other trap types. Since Inverted Bucket traps have poor air-handling capability, they are normally not recommended for most process applications. However, they can be used on certain process applications such as unit heaters and laundry equipment,where discharging air during system start-up is not a critical factor. F\u0026amp;T traps are the preferred choice for systems where air must be quickly discharged.\u003c\/p\u003e\u003ch2\u003eHow It Works\u003c\/h2\u003e\u003cp\u003eWhen the trap is filled with condensate, the inverted bucket inside the steam trap loses its buoyancy and rests on the bottom of the trap. This pulls the disc off the seat allowing condensate to be discharged through the seat orifice located at the top of the trap. When steam enters, it fills the inverted bucket causing the bucket to float to the surface which closes the discharge valve, containing the steam in the system. Eventually, the steam is bled off through a small hole in the top of the bucket causing it to sink, which repeats the cycle.\u003c\/p\u003e\u003ch2\u003eSelection \/ Sizing \/ Capacities\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eSelect A Model With A Higher Maximum Operating Pressure (PMO)\u003c\/strong\u003e that Meet or Exceed the Maximum Steam Pressure or The Trap May Not Open. for Example, the Ib-1031-13-N-150 Has a Max Pmo of 150 Psi, Will Handle Capacity up To 570 Lbs\/hr at Maximum. Choose a Model that Will Handle the Capacity Requirement Based on The Differential Pressure Across the Trap. Reference Capacity Charts.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eExample:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eApplication: 100 Lbs\/hr at 75 Psig Working Pressure and 2 Psi Differential Pressure\u003c\/li\u003e\n\u003cli\u003eSize\/model: Ib1031, 80 Psig, Specify Pipe Size (1\/2\", 3\/4\"), or Ib1041, 80 Psig, Specify Pipe Size (3\/4\", 1\").\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eOptions\u003c\/h2\u003e\u003cp\u003eStrainer and Blowdown valve connection available on 1041, 1042, 1044 \u0026amp; 1038S. We also have 3 accessories for this trap are Thermic vent to improve air handling capability. Internal check valve for superheated or condensate backflow applications.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow to Order Accessories:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCheck Valve (Suffix \u003cstrong\u003eCV\u003c\/strong\u003e) Built-in Inlet Check Valve is recommended when used on Superheated Steam\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent (Suffix \u003cstrong\u003eTV\u003c\/strong\u003e) A Thermic Vent is recommended when using a Bucket Trap on any type of process application or where the removal of air from the system is critical.\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent \u0026amp; Check Valve (Suffix \u003cstrong\u003eTCV\u003c\/strong\u003e) For combination of Check Valve \u0026amp; Thermic Vent\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e\u003cp\u003eTrap must be installed in upright position to function properly. All working components can be replaced with the trap body remaining in-line. With superheated steam, a check valve should be installed at inlet or trap may lose prime. A replacement kit containing the lever and seat assembly is a more economical option than replacing the entire steam trap. Also available are replacement screens, gaskets and buckets. When ordering replacement lever and seat assemblies, specify model and operating pressure. See Replacement Parts and Kits Section for exact cross-reference to Armstrong PCA (Pressure Change Assembly) kits.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eModel\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1031\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSizes\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\"\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eConnections\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eNPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Material\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eCast Iron\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eInternal check valve, Thermic vent\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMO Max. Operating Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e80 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMO Max. Operating Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMA Max. Allowable Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 PSIG up to 450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMA Max. Allowable Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F @ 250 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eIB1031-12-N-080\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap-Spec-Sheet.pdf?v=1786494449\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"Watson McDaniel","offers":[{"title":"Default Title","offer_id":44165898764366,"sku":"IB1031-12-N-080","price":217.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap__96719.1784299721.1280.1280.jpg?v=1786663400"},{"product_id":"watson-mcdaniel-ib1031-12-n-080-cv-inverted-bucket-steam-trap-cast-iron-body-80-psig-in-line-repairability-npt","title":"Watson McDaniel IB1031-12-N-080-CV Inverted Bucket Steam Trap, Cast Iron Body, 80 PSIG, In-line Repairability, NPT","description":"\u003ch2\u003eWatson McDaniel IB1031-12-N-080-CV Inverted Bucket Steam Trap - 1\/2\" NPT (80 PSIG)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWaterhammer Resistant\u003c\/li\u003e\n\u003cli\u003eSuitable for superheated steam (use internal check valve option to eliminate loss of prime)\u003c\/li\u003e\n\u003cli\u003eIn-line repairability is simplified by having all internals attached to the cover\u003c\/li\u003e\n\u003cli\u003eValve \u0026amp; seat are located at the top of the trap body making them less prone to clogging from debris and pipe scale\u003c\/li\u003e\n\u003cli\u003eAll stainless steel internals with hardened valve \u0026amp; seat\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eIB1031 Series\u003c\/h2\u003e\u003cp\u003eThe IB1031 series is the smallest of the IB series. It has a max operating pressure (PMO) of up to 150 PSIG and at max differential pressure, it can handle up to 690 lbs\/hr of condensate.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDRIP, TRACING, PROCESS:\u003c\/strong\u003e IB Series inverted bucket steam traps are used in drip applications to remove condensate from steam mains and steam supply lines. For drip applications, the smaller sized units have adequate capacity. The discharge orifice of the inverted bucket trap is mounted at the top of the trap body, which makes them less susceptible to failure from dirt and debris when compared to other trap types. Since Inverted Bucket traps have poor air-handling capability, they are normally not recommended for most process applications. However, they can be used on certain process applications such as unit heaters and laundry equipment,where discharging air during system start-up is not a critical factor. F\u0026amp;T traps are the preferred choice for systems where air must be quickly discharged.\u003c\/p\u003e\u003ch2\u003eHow It Works\u003c\/h2\u003e\u003cp\u003eWhen the trap is filled with condensate, the inverted bucket inside the steam trap loses its buoyancy and rests on the bottom of the trap. This pulls the disc off the seat allowing condensate to be discharged through the seat orifice located at the top of the trap. When steam enters, it fills the inverted bucket causing the bucket to float to the surface which closes the discharge valve, containing the steam in the system. Eventually, the steam is bled off through a small hole in the top of the bucket causing it to sink, which repeats the cycle.\u003c\/p\u003e\u003ch2\u003eSelection \/ Sizing \/ Capacities\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eSelect A Model With A Higher Maximum Operating Pressure (PMO)\u003c\/strong\u003e that Meet or Exceed the Maximum Steam Pressure or The Trap May Not Open. for Example, the Ib-1031-13-N-150 Has a Max Pmo of 150 Psi, Will Handle Capacity up To 570 Lbs\/hr at Maximum. Choose a Model that Will Handle the Capacity Requirement Based on The Differential Pressure Across the Trap. Reference Capacity Charts.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eExample:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eApplication: 100 Lbs\/hr at 75 Psig Working Pressure and 2 Psi Differential Pressure\u003c\/li\u003e\n\u003cli\u003eSize\/model: Ib1031, 80 Psig, Specify Pipe Size (1\/2\", 3\/4\"), or Ib1041, 80 Psig, Specify Pipe Size (3\/4\", 1\").\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eOptions\u003c\/h2\u003e\u003cp\u003eStrainer and Blowdown valve connection available on 1041, 1042, 1044 \u0026amp; 1038S. We also have 3 accessories for this trap are Thermic vent to improve air handling capability. Internal check valve for superheated or condensate backflow applications.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow to Order Accessories:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCheck Valve (Suffix \u003cstrong\u003eCV\u003c\/strong\u003e) Built-in Inlet Check Valve is recommended when used on Superheated Steam\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent (Suffix \u003cstrong\u003eTV\u003c\/strong\u003e) A Thermic Vent is recommended when using a Bucket Trap on any type of process application or where the removal of air from the system is critical.\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent \u0026amp; Check Valve (Suffix \u003cstrong\u003eTCV\u003c\/strong\u003e) For combination of Check Valve \u0026amp; Thermic Vent\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e\u003cp\u003eTrap must be installed in upright position to function properly. All working components can be replaced with the trap body remaining in-line. With superheated steam, a check valve should be installed at inlet or trap may lose prime. A replacement kit containing the lever and seat assembly is a more economical option than replacing the entire steam trap. Also available are replacement screens, gaskets and buckets. When ordering replacement lever and seat assemblies, specify model and operating pressure. See Replacement Parts and Kits Section for exact cross-reference to Armstrong PCA (Pressure Change Assembly) kits.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eModel\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1031\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSizes\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\"\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eConnections\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eNPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Material\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eCast Iron\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eInternal check valve, Thermic vent\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMO Max. Operating Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e80 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMO Max. Operating Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMA Max. Allowable Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 PSIG up to 450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMA Max. Allowable Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F @ 250 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eIB1031-12-N-080-CV\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap-Spec-Sheet.pdf?v=1786494449\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"Watson McDaniel","offers":[{"title":"Default Title","offer_id":44165898829902,"sku":"IB1031-12-N-080-CV","price":364.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap__22788.1784299743.1280.1280.jpg?v=1786663402"},{"product_id":"watson-mcdaniel-ib1031-12-n-080-tv-inverted-bucket-steam-trap-cast-iron-body-80-psig-in-line-repairability-npt","title":"Watson McDaniel IB1031-12-N-080-TV Inverted Bucket Steam Trap, Cast Iron Body, 80 PSIG, In-line Repairability, NPT","description":"\u003ch2\u003eWatson McDaniel IB1031-12-N-080-TV Inverted Bucket Steam Trap - 1\/2\" NPT (80 PSIG)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWaterhammer Resistant\u003c\/li\u003e\n\u003cli\u003eSuitable for superheated steam (use internal check valve option to eliminate loss of prime)\u003c\/li\u003e\n\u003cli\u003eIn-line repairability is simplified by having all internals attached to the cover\u003c\/li\u003e\n\u003cli\u003eValve \u0026amp; seat are located at the top of the trap body making them less prone to clogging from debris and pipe scale\u003c\/li\u003e\n\u003cli\u003eAll stainless steel internals with hardened valve \u0026amp; seat\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eIB1031 Series\u003c\/h2\u003e\u003cp\u003eThe IB1031 series is the smallest of the IB series. It has a max operating pressure (PMO) of up to 150 PSIG and at max differential pressure, it can handle up to 690 lbs\/hr of condensate.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDRIP, TRACING, PROCESS:\u003c\/strong\u003e IB Series inverted bucket steam traps are used in drip applications to remove condensate from steam mains and steam supply lines. For drip applications, the smaller sized units have adequate capacity. The discharge orifice of the inverted bucket trap is mounted at the top of the trap body, which makes them less susceptible to failure from dirt and debris when compared to other trap types. Since Inverted Bucket traps have poor air-handling capability, they are normally not recommended for most process applications. However, they can be used on certain process applications such as unit heaters and laundry equipment,where discharging air during system start-up is not a critical factor. F\u0026amp;T traps are the preferred choice for systems where air must be quickly discharged.\u003c\/p\u003e\u003ch2\u003eHow It Works\u003c\/h2\u003e\u003cp\u003eWhen the trap is filled with condensate, the inverted bucket inside the steam trap loses its buoyancy and rests on the bottom of the trap. This pulls the disc off the seat allowing condensate to be discharged through the seat orifice located at the top of the trap. When steam enters, it fills the inverted bucket causing the bucket to float to the surface which closes the discharge valve, containing the steam in the system. Eventually, the steam is bled off through a small hole in the top of the bucket causing it to sink, which repeats the cycle.\u003c\/p\u003e\u003ch2\u003eSelection \/ Sizing \/ Capacities\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eSelect A Model With A Higher Maximum Operating Pressure (PMO)\u003c\/strong\u003e that Meet or Exceed the Maximum Steam Pressure or The Trap May Not Open. for Example, the Ib-1031-13-N-150 Has a Max Pmo of 150 Psi, Will Handle Capacity up To 570 Lbs\/hr at Maximum. Choose a Model that Will Handle the Capacity Requirement Based on The Differential Pressure Across the Trap. Reference Capacity Charts.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eExample:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eApplication: 100 Lbs\/hr at 75 Psig Working Pressure and 2 Psi Differential Pressure\u003c\/li\u003e\n\u003cli\u003eSize\/model: Ib1031, 80 Psig, Specify Pipe Size (1\/2\", 3\/4\"), or Ib1041, 80 Psig, Specify Pipe Size (3\/4\", 1\").\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eOptions\u003c\/h2\u003e\u003cp\u003eStrainer and Blowdown valve connection available on 1041, 1042, 1044 \u0026amp; 1038S. We also have 3 accessories for this trap are Thermic vent to improve air handling capability. Internal check valve for superheated or condensate backflow applications.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow to Order Accessories:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCheck Valve (Suffix \u003cstrong\u003eCV\u003c\/strong\u003e) Built-in Inlet Check Valve is recommended when used on Superheated Steam\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent (Suffix \u003cstrong\u003eTV\u003c\/strong\u003e) A Thermic Vent is recommended when using a Bucket Trap on any type of process application or where the removal of air from the system is critical.\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent \u0026amp; Check Valve (Suffix \u003cstrong\u003eTCV\u003c\/strong\u003e) For combination of Check Valve \u0026amp; Thermic Vent\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e\u003cp\u003eTrap must be installed in upright position to function properly. All working components can be replaced with the trap body remaining in-line. With superheated steam, a check valve should be installed at inlet or trap may lose prime. A replacement kit containing the lever and seat assembly is a more economical option than replacing the entire steam trap. Also available are replacement screens, gaskets and buckets. When ordering replacement lever and seat assemblies, specify model and operating pressure. See Replacement Parts and Kits Section for exact cross-reference to Armstrong PCA (Pressure Change Assembly) kits.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eModel\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1031\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSizes\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\"\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eConnections\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eNPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Material\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eCast Iron\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eInternal check valve, Thermic vent\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMO Max. Operating Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e80 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMO Max. Operating Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMA Max. Allowable Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 PSIG up to 450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMA Max. Allowable Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F @ 250 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eIB1031-12-N-080-TV\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap-Spec-Sheet.pdf?v=1786494449\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"Watson McDaniel","offers":[{"title":"Default Title","offer_id":44165898895438,"sku":"IB1031-12-N-080-TV","price":435.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap__14384.1784299743.1280.1280.jpg?v=1786663404"},{"product_id":"watson-mcdaniel-ib1031-12-n-080-tcv-inverted-bucket-steam-trap-cast-iron-body-80-psig-in-line-repairability-npt","title":"Watson McDaniel IB1031-12-N-080-TCV Inverted Bucket Steam Trap, Cast Iron Body, 80 PSIG, In-line Repairability, NPT","description":"\u003ch2\u003eWatson McDaniel IB1031-12-N-080-TCV Inverted Bucket Steam Trap - 1\/2\" NPT (80 PSIG)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWaterhammer Resistant\u003c\/li\u003e\n\u003cli\u003eSuitable for superheated steam (use internal check valve option to eliminate loss of prime)\u003c\/li\u003e\n\u003cli\u003eIn-line repairability is simplified by having all internals attached to the cover\u003c\/li\u003e\n\u003cli\u003eValve \u0026amp; seat are located at the top of the trap body making them less prone to clogging from debris and pipe scale\u003c\/li\u003e\n\u003cli\u003eAll stainless steel internals with hardened valve \u0026amp; seat\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eIB1031 Series\u003c\/h2\u003e\u003cp\u003eThe IB1031 series is the smallest of the IB series. It has a max operating pressure (PMO) of up to 150 PSIG and at max differential pressure, it can handle up to 690 lbs\/hr of condensate.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDRIP, TRACING, PROCESS:\u003c\/strong\u003e IB Series inverted bucket steam traps are used in drip applications to remove condensate from steam mains and steam supply lines. For drip applications, the smaller sized units have adequate capacity. The discharge orifice of the inverted bucket trap is mounted at the top of the trap body, which makes them less susceptible to failure from dirt and debris when compared to other trap types. Since Inverted Bucket traps have poor air-handling capability, they are normally not recommended for most process applications. However, they can be used on certain process applications such as unit heaters and laundry equipment,where discharging air during system start-up is not a critical factor. F\u0026amp;T traps are the preferred choice for systems where air must be quickly discharged.\u003c\/p\u003e\u003ch2\u003eHow It Works\u003c\/h2\u003e\u003cp\u003eWhen the trap is filled with condensate, the inverted bucket inside the steam trap loses its buoyancy and rests on the bottom of the trap. This pulls the disc off the seat allowing condensate to be discharged through the seat orifice located at the top of the trap. When steam enters, it fills the inverted bucket causing the bucket to float to the surface which closes the discharge valve, containing the steam in the system. Eventually, the steam is bled off through a small hole in the top of the bucket causing it to sink, which repeats the cycle.\u003c\/p\u003e\u003ch2\u003eSelection \/ Sizing \/ Capacities\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eSelect A Model With A Higher Maximum Operating Pressure (PMO)\u003c\/strong\u003e that Meet or Exceed the Maximum Steam Pressure or The Trap May Not Open. for Example, the Ib-1031-13-N-150 Has a Max Pmo of 150 Psi, Will Handle Capacity up To 570 Lbs\/hr at Maximum. Choose a Model that Will Handle the Capacity Requirement Based on The Differential Pressure Across the Trap. Reference Capacity Charts.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eExample:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eApplication: 100 Lbs\/hr at 75 Psig Working Pressure and 2 Psi Differential Pressure\u003c\/li\u003e\n\u003cli\u003eSize\/model: Ib1031, 80 Psig, Specify Pipe Size (1\/2\", 3\/4\"), or Ib1041, 80 Psig, Specify Pipe Size (3\/4\", 1\").\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eOptions\u003c\/h2\u003e\u003cp\u003eStrainer and Blowdown valve connection available on 1041, 1042, 1044 \u0026amp; 1038S. We also have 3 accessories for this trap are Thermic vent to improve air handling capability. Internal check valve for superheated or condensate backflow applications.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow to Order Accessories:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCheck Valve (Suffix \u003cstrong\u003eCV\u003c\/strong\u003e) Built-in Inlet Check Valve is recommended when used on Superheated Steam\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent (Suffix \u003cstrong\u003eTV\u003c\/strong\u003e) A Thermic Vent is recommended when using a Bucket Trap on any type of process application or where the removal of air from the system is critical.\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent \u0026amp; Check Valve (Suffix \u003cstrong\u003eTCV\u003c\/strong\u003e) For combination of Check Valve \u0026amp; Thermic Vent\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e\u003cp\u003eTrap must be installed in upright position to function properly. All working components can be replaced with the trap body remaining in-line. With superheated steam, a check valve should be installed at inlet or trap may lose prime. A replacement kit containing the lever and seat assembly is a more economical option than replacing the entire steam trap. Also available are replacement screens, gaskets and buckets. When ordering replacement lever and seat assemblies, specify model and operating pressure. See Replacement Parts and Kits Section for exact cross-reference to Armstrong PCA (Pressure Change Assembly) kits.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eModel\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1031\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSizes\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\"\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eConnections\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eNPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Material\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eCast Iron\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eInternal check valve, Thermic vent\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMO Max. Operating Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e80 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMO Max. Operating Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMA Max. Allowable Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 PSIG up to 450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMA Max. Allowable Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F @ 250 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eIB1031-12-N-080-TCV\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap-Spec-Sheet.pdf?v=1786494449\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"Watson McDaniel","offers":[{"title":"Default Title","offer_id":44165898960974,"sku":"IB1031-12-N-080-TCV","price":631.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap__14819.1784299743.1280.1280.jpg?v=1786663407"},{"product_id":"watson-mcdaniel-ib1031-series-inverted-bucket-steam-trap-cast-iron-body-125-psig-in-line-repairability-3-4-npt","title":"Watson McDaniel IB1031 Series Inverted Bucket Steam Trap, Cast Iron Body, 125 PSIG, In-line Repairability, 3\/4\" NPT","description":"\u003ch2\u003eWatson McDaniel IB1031 Series Inverted Bucket Steam Trap - 3\/4\" NPT (125 PSIG)\u003c\/h2\u003e \u003ch2\u003eFeatures:\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eWaterhammer Resistant\u003c\/li\u003e \u003cli\u003eSuitable for superheated steam (use internal check valve option to eliminate loss of prime)\u003c\/li\u003e \u003cli\u003eIn-line repairability is simplified by having all internals attached to the cover\u003c\/li\u003e \u003cli\u003eValve \u0026amp; seat are located at the top of the trap body making them less prone to clogging from debris and pipe scale\u003c\/li\u003e \u003cli\u003eAll stainless steel internals with hardened valve \u0026amp; seat\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e \u003ch2\u003eIB1031 Series\u003c\/h2\u003e \u003cp\u003eThe IB1031 series is the smallest of the IB series. It has a max operating pressure (PMO) of up to 150 PSIG and at max differential pressure, it can handle up to 690 lbs\/hr of condensate.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eDRIP, TRACING, PROCESS:\u003c\/strong\u003e IB Series inverted bucket steam traps are used in drip applications to remove condensate from steam mains and steam supply lines. For drip applications, the smaller sized units have adequate capacity. The discharge orifice of the inverted bucket trap is mounted at the top of the trap body, which makes them less susceptible to failure from dirt and debris when compared to other trap types. Since Inverted Bucket traps have poor air-handling capability, they are normally not recommended for most process applications. However, they can be used on certain process applications such as unit heaters and laundry equipment,where discharging air during system start-up is not a critical factor. F\u0026amp;T traps are the preferred choice for systems where air must be quickly discharged.\u003c\/p\u003e \u003ch2\u003eHow It Works\u003c\/h2\u003e \u003cp\u003eWhen the trap is filled with condensate, the inverted bucket inside the steam trap loses its buoyancy and rests on the bottom of the trap. This pulls the disc off the seat allowing condensate to be discharged through the seat orifice located at the top of the trap. When steam enters, it fills the inverted bucket causing the bucket to float to the surface which closes the discharge valve, containing the steam in the system. Eventually, the steam is bled off through a small hole in the top of the bucket causing it to sink, which repeats the cycle.\u003c\/p\u003e \u003ch2\u003eSelection \/ Sizing \/ Capacities\u003c\/h2\u003e \u003cp\u003e\u003cstrong\u003eSelect A Model With A Higher Maximum Operating Pressure (PMO)\u003c\/strong\u003e that Meet or Exceed the Maximum Steam Pressure or The Trap May Not Open. for Example, the Ib-1031-13-N-150 Has a Max Pmo of 150 Psi, Will Handle Capacity up To 570 Lbs\/hr at Maximum. Choose a Model that Will Handle the Capacity Requirement Based on The Differential Pressure Across the Trap. Reference Capacity Charts.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eExample:\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eApplication: 100 Lbs\/hr at 75 Psig Working Pressure and 2 Psi Differential Pressure\u003c\/li\u003e \u003cli\u003eSize\/model: Ib1031, 80 Psig, Specify Pipe Size (1\/2\", 3\/4\"), or Ib1041, 80 Psig, Specify Pipe Size (3\/4\", 1\").\u003c\/li\u003e \u003c\/ul\u003e \u003ch2\u003eOptions\u003c\/h2\u003e \u003cp\u003eStrainer and Blowdown valve connection available on 1041, 1042, 1044 \u0026amp; 1038S. We also have 3 accessories for this trap are Thermic vent to improve air handling capability. Internal check valve for superheated or condensate backflow applications.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eHow to Order Accessories:\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eCheck Valve (Suffix \u003cstrong\u003eCV\u003c\/strong\u003e) Built-in Inlet Check Valve is recommended when used on Superheated Steam\u003cbr\u003e \u003cul\u003e \u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eCV\u003c\/strong\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003cli\u003eThermic Vent (Suffix \u003cstrong\u003eTV\u003c\/strong\u003e) A Thermic Vent is recommended when using a Bucket Trap on any type of process application or where the removal of air from the system is critical.\u003cbr\u003e \u003cul\u003e \u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTV\u003c\/strong\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003cli\u003eThermic Vent \u0026amp; Check Valve (Suffix \u003cstrong\u003eTCV\u003c\/strong\u003e) For combination of Check Valve \u0026amp; Thermic Vent\u003cbr\u003e \u003cul\u003e \u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTCV\u003c\/strong\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003ch2\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e \u003cp\u003eTrap must be installed in upright position to function properly. All working components can be replaced with the trap body remaining in-line. With superheated steam, a check valve should be installed at inlet or trap may lose prime. A replacement kit containing the lever and seat assembly is a more economical option than replacing the entire steam trap. Also available are replacement screens, gaskets and buckets. When ordering replacement lever and seat assemblies, specify model and operating pressure. See Replacement Parts and Kits Section for exact cross-reference to Armstrong PCA (Pressure Change Assembly) kits.\u003c\/p\u003e \u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e \u003cdiv class=\"tech\"\u003e \u003ch2\u003eTechnical Specifications\u003c\/h2\u003e \u003cdiv class=\"specs\"\u003e \u003cdiv class=\"column\"\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eModel\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e1031\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eSizes\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e3\/4\"\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eConnections\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eNPT\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eBody Material\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eCast Iron\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eInternal check valve, Thermic vent\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"column\"\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003ePMO Max. Operating Pressure\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e125 PSIG\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eTMO Max. Operating Temperature\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e450°F\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003ePMA Max. Allowable Pressure\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e250 PSIG up to 450°F\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eTMA Max. Allowable Temperature\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e450°F @ 250 PSIG\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e \u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap-Spec-Sheet.pdf?v=1786494449\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"Watson McDaniel","offers":[{"title":"Default Title","offer_id":44165899026510,"sku":"WM-IB1031-34-125","price":217.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap__26814.1784299721.1280.1280.jpg?v=1786663409"},{"product_id":"watson-mcdaniel-ib1031-13-n-125-inverted-bucket-steam-trap-cast-iron-body-125-psig-in-line-repairability-npt","title":"Watson McDaniel IB1031-13-N-125 Inverted Bucket Steam Trap, Cast Iron Body, 125 PSIG, In-line Repairability, NPT","description":"\u003ch2\u003eWatson McDaniel IB1031-13-N-125 Inverted Bucket Steam Trap - 3\/4\" NPT (125 PSIG)\u003c\/h2\u003e \u003ch2\u003eFeatures:\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eWaterhammer Resistant\u003c\/li\u003e \u003cli\u003eSuitable for superheated steam (use internal check valve option to eliminate loss of prime)\u003c\/li\u003e \u003cli\u003eIn-line repairability is simplified by having all internals attached to the cover\u003c\/li\u003e \u003cli\u003eValve \u0026amp; seat are located at the top of the trap body making them less prone to clogging from debris and pipe scale\u003c\/li\u003e \u003cli\u003eAll stainless steel internals with hardened valve \u0026amp; seat\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e \u003ch2\u003eIB1031 Series\u003c\/h2\u003e \u003cp\u003eThe IB1031 series is the smallest of the IB series. It has a max operating pressure (PMO) of up to 150 PSIG and at max differential pressure, it can handle up to 690 lbs\/hr of condensate.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eDRIP, TRACING, PROCESS:\u003c\/strong\u003e IB Series inverted bucket steam traps are used in drip applications to remove condensate from steam mains and steam supply lines. For drip applications, the smaller sized units have adequate capacity. The discharge orifice of the inverted bucket trap is mounted at the top of the trap body, which makes them less susceptible to failure from dirt and debris when compared to other trap types. Since Inverted Bucket traps have poor air-handling capability, they are normally not recommended for most process applications. However, they can be used on certain process applications such as unit heaters and laundry equipment,where discharging air during system start-up is not a critical factor. F\u0026amp;T traps are the preferred choice for systems where air must be quickly discharged.\u003c\/p\u003e \u003ch2\u003eHow It Works\u003c\/h2\u003e \u003cp\u003eWhen the trap is filled with condensate, the inverted bucket inside the steam trap loses its buoyancy and rests on the bottom of the trap. This pulls the disc off the seat allowing condensate to be discharged through the seat orifice located at the top of the trap. When steam enters, it fills the inverted bucket causing the bucket to float to the surface which closes the discharge valve, containing the steam in the system. Eventually, the steam is bled off through a small hole in the top of the bucket causing it to sink, which repeats the cycle.\u003c\/p\u003e \u003ch2\u003eSelection \/ Sizing \/ Capacities\u003c\/h2\u003e \u003cp\u003e\u003cstrong\u003eSelect A Model With A Higher Maximum Operating Pressure (PMO)\u003c\/strong\u003e that Meet or Exceed the Maximum Steam Pressure or The Trap May Not Open. for Example, the Ib-1031-13-N-150 Has a Max Pmo of 150 Psi, Will Handle Capacity up To 570 Lbs\/hr at Maximum. Choose a Model that Will Handle the Capacity Requirement Based on The Differential Pressure Across the Trap. Reference Capacity Charts.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eExample:\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eApplication: 100 Lbs\/hr at 75 Psig Working Pressure and 2 Psi Differential Pressure\u003c\/li\u003e \u003cli\u003eSize\/model: Ib1031, 80 Psig, Specify Pipe Size (1\/2\", 3\/4\"), or Ib1041, 80 Psig, Specify Pipe Size (3\/4\", 1\").\u003c\/li\u003e \u003c\/ul\u003e \u003ch2\u003eOptions\u003c\/h2\u003e \u003cp\u003eStrainer and Blowdown valve connection available on 1041, 1042, 1044 \u0026amp; 1038S. We also have 3 accessories for this trap are Thermic vent to improve air handling capability. Internal check valve for superheated or condensate backflow applications.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eHow to Order Accessories:\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eCheck Valve (Suffix \u003cstrong\u003eCV\u003c\/strong\u003e) Built-in Inlet Check Valve is recommended when used on Superheated Steam\u003cbr\u003e \u003cul\u003e \u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eCV\u003c\/strong\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003cli\u003eThermic Vent (Suffix \u003cstrong\u003eTV\u003c\/strong\u003e) A Thermic Vent is recommended when using a Bucket Trap on any type of process application or where the removal of air from the system is critical.\u003cbr\u003e \u003cul\u003e \u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTV\u003c\/strong\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003cli\u003eThermic Vent \u0026amp; Check Valve (Suffix \u003cstrong\u003eTCV\u003c\/strong\u003e) For combination of Check Valve \u0026amp; Thermic Vent\u003cbr\u003e \u003cul\u003e \u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTCV\u003c\/strong\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003ch2\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e \u003cp\u003eTrap must be installed in upright position to function properly. All working components can be replaced with the trap body remaining in-line. With superheated steam, a check valve should be installed at inlet or trap may lose prime. A replacement kit containing the lever and seat assembly is a more economical option than replacing the entire steam trap. Also available are replacement screens, gaskets and buckets. When ordering replacement lever and seat assemblies, specify model and operating pressure. See Replacement Parts and Kits Section for exact cross-reference to Armstrong PCA (Pressure Change Assembly) kits.\u003c\/p\u003e \u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e \u003cdiv class=\"tech\"\u003e \u003ch2\u003eTechnical Specifications\u003c\/h2\u003e \u003cdiv class=\"specs\"\u003e \u003cdiv class=\"column\"\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eModel\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e1031\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eSizes\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e3\/4\"\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eConnections\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eNPT\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eBody Material\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eCast Iron\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eInternal check valve, Thermic vent\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003ePMO Max. Operating Pressure\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e125 PSIG\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"column\"\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eTMO Max. Operating Temperature\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e450°F\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003ePMA Max. Allowable Pressure\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e250 PSIG up to 450°F\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eTMA Max. Allowable Temperature\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e450°F @ 250 PSIG\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eIB1031-13-N-125\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e \u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap-Spec-Sheet.pdf?v=1786494449\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"Watson McDaniel","offers":[{"title":"Default Title","offer_id":44165899092046,"sku":"IB1031-13-N-125","price":217.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap__23410.1784299721.1280.1280.jpg?v=1786663411"},{"product_id":"watson-mcdaniel-ib1031-13-n-125-cv-inverted-bucket-steam-trap-cast-iron-body-125-psig-in-line-repairability-npt","title":"Watson McDaniel IB1031-13-N-125-CV Inverted Bucket Steam Trap, Cast Iron Body, 125 PSIG, In-line Repairability, NPT","description":"\u003ch2\u003eWatson McDaniel IB1031-13-N-125-CV Inverted Bucket Steam Trap - 3\/4\" NPT (125 PSIG)\u003c\/h2\u003e \u003ch2\u003eFeatures:\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eWaterhammer Resistant\u003c\/li\u003e \u003cli\u003eSuitable for superheated steam (use internal check valve option to eliminate loss of prime)\u003c\/li\u003e \u003cli\u003eIn-line repairability is simplified by having all internals attached to the cover\u003c\/li\u003e \u003cli\u003eValve \u0026amp; seat are located at the top of the trap body making them less prone to clogging from debris and pipe scale\u003c\/li\u003e \u003cli\u003eAll stainless steel internals with hardened valve \u0026amp; seat\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e \u003ch2\u003eIB1031 Series\u003c\/h2\u003e \u003cp\u003eThe IB1031 series is the smallest of the IB series. It has a max operating pressure (PMO) of up to 150 PSIG and at max differential pressure, it can handle up to 690 lbs\/hr of condensate.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eDRIP, TRACING, PROCESS:\u003c\/strong\u003e IB Series inverted bucket steam traps are used in drip applications to remove condensate from steam mains and steam supply lines. For drip applications, the smaller sized units have adequate capacity. The discharge orifice of the inverted bucket trap is mounted at the top of the trap body, which makes them less susceptible to failure from dirt and debris when compared to other trap types. Since Inverted Bucket traps have poor air-handling capability, they are normally not recommended for most process applications. However, they can be used on certain process applications such as unit heaters and laundry equipment,where discharging air during system start-up is not a critical factor. F\u0026amp;T traps are the preferred choice for systems where air must be quickly discharged.\u003c\/p\u003e \u003ch2\u003eHow It Works\u003c\/h2\u003e \u003cp\u003eWhen the trap is filled with condensate, the inverted bucket inside the steam trap loses its buoyancy and rests on the bottom of the trap. This pulls the disc off the seat allowing condensate to be discharged through the seat orifice located at the top of the trap. When steam enters, it fills the inverted bucket causing the bucket to float to the surface which closes the discharge valve, containing the steam in the system. Eventually, the steam is bled off through a small hole in the top of the bucket causing it to sink, which repeats the cycle.\u003c\/p\u003e \u003ch2\u003eSelection \/ Sizing \/ Capacities\u003c\/h2\u003e \u003cp\u003e\u003cstrong\u003eSelect A Model With A Higher Maximum Operating Pressure (PMO)\u003c\/strong\u003e that Meet or Exceed the Maximum Steam Pressure or The Trap May Not Open. for Example, the Ib-1031-13-N-150 Has a Max Pmo of 150 Psi, Will Handle Capacity up To 570 Lbs\/hr at Maximum. Choose a Model that Will Handle the Capacity Requirement Based on The Differential Pressure Across the Trap. Reference Capacity Charts.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eExample:\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eApplication: 100 Lbs\/hr at 75 Psig Working Pressure and 2 Psi Differential Pressure\u003c\/li\u003e \u003cli\u003eSize\/model: Ib1031, 80 Psig, Specify Pipe Size (1\/2\", 3\/4\"), or Ib1041, 80 Psig, Specify Pipe Size (3\/4\", 1\").\u003c\/li\u003e \u003c\/ul\u003e \u003ch2\u003eOptions\u003c\/h2\u003e \u003cp\u003eStrainer and Blowdown valve connection available on 1041, 1042, 1044 \u0026amp; 1038S. We also have 3 accessories for this trap are Thermic vent to improve air handling capability. Internal check valve for superheated or condensate backflow applications.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eHow to Order Accessories:\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eCheck Valve (Suffix \u003cstrong\u003eCV\u003c\/strong\u003e) Built-in Inlet Check Valve is recommended when used on Superheated Steam\u003cbr\u003e \u003cul\u003e \u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eCV\u003c\/strong\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003cli\u003eThermic Vent (Suffix \u003cstrong\u003eTV\u003c\/strong\u003e) A Thermic Vent is recommended when using a Bucket Trap on any type of process application or where the removal of air from the system is critical.\u003cbr\u003e \u003cul\u003e \u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTV\u003c\/strong\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003cli\u003eThermic Vent \u0026amp; Check Valve (Suffix \u003cstrong\u003eTCV\u003c\/strong\u003e) For combination of Check Valve \u0026amp; Thermic Vent\u003cbr\u003e \u003cul\u003e \u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTCV\u003c\/strong\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003ch2\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e \u003cp\u003eTrap must be installed in upright position to function properly. All working components can be replaced with the trap body remaining in-line. With superheated steam, a check valve should be installed at inlet or trap may lose prime. A replacement kit containing the lever and seat assembly is a more economical option than replacing the entire steam trap. Also available are replacement screens, gaskets and buckets. When ordering replacement lever and seat assemblies, specify model and operating pressure. See Replacement Parts and Kits Section for exact cross-reference to Armstrong PCA (Pressure Change Assembly) kits.\u003c\/p\u003e \u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e \u003cdiv class=\"tech\"\u003e \u003ch2\u003eTechnical Specifications\u003c\/h2\u003e \u003cdiv class=\"specs\"\u003e \u003cdiv class=\"column\"\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eModel\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e1031\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eSizes\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e3\/4\"\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eConnections\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eNPT\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eBody Material\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eCast Iron\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eInternal check valve, Thermic vent\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003ePMO Max. Operating Pressure\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e125 PSIG\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"column\"\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eTMO Max. Operating Temperature\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e450°F\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003ePMA Max. Allowable Pressure\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e250 PSIG up to 450°F\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eTMA Max. Allowable Temperature\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e450°F @ 250 PSIG\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eIB1031-13-N-125-CV\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e \u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap-Spec-Sheet.pdf?v=1786494449\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"Watson McDaniel","offers":[{"title":"Default Title","offer_id":44165899157582,"sku":"IB1031-13-N-125-CV","price":364.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap__52661.1784299743.1280.1280.jpg?v=1786663414"},{"product_id":"watson-mcdaniel-ib1031-13-n-125-tv-inverted-bucket-steam-trap-cast-iron-body-125-psig-in-line-repairability-npt","title":"Watson McDaniel IB1031-13-N-125-TV Inverted Bucket Steam Trap, Cast Iron Body, 125 PSIG, In-line Repairability, NPT","description":"\u003ch2\u003eWatson McDaniel IB1031-13-N-125-TV Inverted Bucket Steam Trap - 3\/4\" NPT (125 PSIG)\u003c\/h2\u003e \u003ch2\u003eFeatures:\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eWaterhammer Resistant\u003c\/li\u003e \u003cli\u003eSuitable for superheated steam (use internal check valve option to eliminate loss of prime)\u003c\/li\u003e \u003cli\u003eIn-line repairability is simplified by having all internals attached to the cover\u003c\/li\u003e \u003cli\u003eValve \u0026amp; seat are located at the top of the trap body making them less prone to clogging from debris and pipe scale\u003c\/li\u003e \u003cli\u003eAll stainless steel internals with hardened valve \u0026amp; seat\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e \u003ch2\u003eIB1031 Series\u003c\/h2\u003e \u003cp\u003eThe IB1031 series is the smallest of the IB series. It has a max operating pressure (PMO) of up to 150 PSIG and at max differential pressure, it can handle up to 690 lbs\/hr of condensate.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eDRIP, TRACING, PROCESS:\u003c\/strong\u003e IB Series inverted bucket steam traps are used in drip applications to remove condensate from steam mains and steam supply lines. For drip applications, the smaller sized units have adequate capacity. The discharge orifice of the inverted bucket trap is mounted at the top of the trap body, which makes them less susceptible to failure from dirt and debris when compared to other trap types. Since Inverted Bucket traps have poor air-handling capability, they are normally not recommended for most process applications. However, they can be used on certain process applications such as unit heaters and laundry equipment,where discharging air during system start-up is not a critical factor. F\u0026amp;T traps are the preferred choice for systems where air must be quickly discharged.\u003c\/p\u003e \u003ch2\u003eHow It Works\u003c\/h2\u003e \u003cp\u003eWhen the trap is filled with condensate, the inverted bucket inside the steam trap loses its buoyancy and rests on the bottom of the trap. This pulls the disc off the seat allowing condensate to be discharged through the seat orifice located at the top of the trap. When steam enters, it fills the inverted bucket causing the bucket to float to the surface which closes the discharge valve, containing the steam in the system. Eventually, the steam is bled off through a small hole in the top of the bucket causing it to sink, which repeats the cycle.\u003c\/p\u003e \u003ch2\u003eSelection \/ Sizing \/ Capacities\u003c\/h2\u003e \u003cp\u003e\u003cstrong\u003eSelect A Model With A Higher Maximum Operating Pressure (PMO)\u003c\/strong\u003e that Meet or Exceed the Maximum Steam Pressure or The Trap May Not Open. for Example, the Ib-1031-13-N-150 Has a Max Pmo of 150 Psi, Will Handle Capacity up To 570 Lbs\/hr at Maximum. Choose a Model that Will Handle the Capacity Requirement Based on The Differential Pressure Across the Trap. Reference Capacity Charts.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eExample:\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eApplication: 100 Lbs\/hr at 75 Psig Working Pressure and 2 Psi Differential Pressure\u003c\/li\u003e \u003cli\u003eSize\/model: Ib1031, 80 Psig, Specify Pipe Size (1\/2\", 3\/4\"), or Ib1041, 80 Psig, Specify Pipe Size (3\/4\", 1\").\u003c\/li\u003e \u003c\/ul\u003e \u003ch2\u003eOptions\u003c\/h2\u003e \u003cp\u003eStrainer and Blowdown valve connection available on 1041, 1042, 1044 \u0026amp; 1038S. We also have 3 accessories for this trap are Thermic vent to improve air handling capability. Internal check valve for superheated or condensate backflow applications.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eHow to Order Accessories:\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eCheck Valve (Suffix \u003cstrong\u003eCV\u003c\/strong\u003e) Built-in Inlet Check Valve is recommended when used on Superheated Steam\u003cbr\u003e \u003cul\u003e \u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eCV\u003c\/strong\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003cli\u003eThermic Vent (Suffix \u003cstrong\u003eTV\u003c\/strong\u003e) A Thermic Vent is recommended when using a Bucket Trap on any type of process application or where the removal of air from the system is critical.\u003cbr\u003e \u003cul\u003e \u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTV\u003c\/strong\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003cli\u003eThermic Vent \u0026amp; Check Valve (Suffix \u003cstrong\u003eTCV\u003c\/strong\u003e) For combination of Check Valve \u0026amp; Thermic Vent\u003cbr\u003e \u003cul\u003e \u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTCV\u003c\/strong\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003ch2\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e \u003cp\u003eTrap must be installed in upright position to function properly. All working components can be replaced with the trap body remaining in-line. With superheated steam, a check valve should be installed at inlet or trap may lose prime. A replacement kit containing the lever and seat assembly is a more economical option than replacing the entire steam trap. Also available are replacement screens, gaskets and buckets. When ordering replacement lever and seat assemblies, specify model and operating pressure. See Replacement Parts and Kits Section for exact cross-reference to Armstrong PCA (Pressure Change Assembly) kits.\u003c\/p\u003e \u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e \u003cdiv class=\"tech\"\u003e \u003ch2\u003eTechnical Specifications\u003c\/h2\u003e \u003cdiv class=\"specs\"\u003e \u003cdiv class=\"column\"\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eModel\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e1031\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eSizes\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e3\/4\"\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eConnections\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eNPT\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eBody Material\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eCast Iron\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eInternal check valve, Thermic vent\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003ePMO Max. Operating Pressure\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e125 PSIG\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"column\"\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eTMO Max. Operating Temperature\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e450°F\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003ePMA Max. Allowable Pressure\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e250 PSIG up to 450°F\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eTMA Max. Allowable Temperature\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e450°F @ 250 PSIG\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eIB1031-13-N-125-TV\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e \u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap-Spec-Sheet.pdf?v=1786494449\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"Watson McDaniel","offers":[{"title":"Default Title","offer_id":44165899223118,"sku":"IB1031-13-N-125-TV","price":435.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap__30481.1784299743.1280.1280.jpg?v=1786663416"},{"product_id":"watson-mcdaniel-ib1031-13-n-125-tcv-inverted-bucket-steam-trap-cast-iron-body-125-psig-in-line-repairability-npt","title":"Watson McDaniel IB1031-13-N-125-TCV Inverted Bucket Steam Trap, Cast Iron Body, 125 PSIG, In-line Repairability, NPT","description":"\u003ch2\u003eWatson McDaniel IB1031-13-N-125-TCV Inverted Bucket Steam Trap - 3\/4\" NPT (125 PSIG)\u003c\/h2\u003e \u003ch2\u003eFeatures:\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eWaterhammer Resistant\u003c\/li\u003e \u003cli\u003eSuitable for superheated steam (use internal check valve option to eliminate loss of prime)\u003c\/li\u003e \u003cli\u003eIn-line repairability is simplified by having all internals attached to the cover\u003c\/li\u003e \u003cli\u003eValve \u0026amp; seat are located at the top of the trap body making them less prone to clogging from debris and pipe scale\u003c\/li\u003e \u003cli\u003eAll stainless steel internals with hardened valve \u0026amp; seat\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e \u003ch2\u003eIB1031 Series\u003c\/h2\u003e \u003cp\u003eThe IB1031 series is the smallest of the IB series. It has a max operating pressure (PMO) of up to 150 PSIG and at max differential pressure, it can handle up to 690 lbs\/hr of condensate.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eDRIP, TRACING, PROCESS:\u003c\/strong\u003e IB Series inverted bucket steam traps are used in drip applications to remove condensate from steam mains and steam supply lines. For drip applications, the smaller sized units have adequate capacity. The discharge orifice of the inverted bucket trap is mounted at the top of the trap body, which makes them less susceptible to failure from dirt and debris when compared to other trap types. Since Inverted Bucket traps have poor air-handling capability, they are normally not recommended for most process applications. However, they can be used on certain process applications such as unit heaters and laundry equipment,where discharging air during system start-up is not a critical factor. F\u0026amp;T traps are the preferred choice for systems where air must be quickly discharged.\u003c\/p\u003e \u003ch2\u003eHow It Works\u003c\/h2\u003e \u003cp\u003eWhen the trap is filled with condensate, the inverted bucket inside the steam trap loses its buoyancy and rests on the bottom of the trap. This pulls the disc off the seat allowing condensate to be discharged through the seat orifice located at the top of the trap. When steam enters, it fills the inverted bucket causing the bucket to float to the surface which closes the discharge valve, containing the steam in the system. Eventually, the steam is bled off through a small hole in the top of the bucket causing it to sink, which repeats the cycle.\u003c\/p\u003e \u003ch2\u003eSelection \/ Sizing \/ Capacities\u003c\/h2\u003e \u003cp\u003e\u003cstrong\u003eSelect A Model With A Higher Maximum Operating Pressure (PMO)\u003c\/strong\u003e that Meet or Exceed the Maximum Steam Pressure or The Trap May Not Open. for Example, the Ib-1031-13-N-150 Has a Max Pmo of 150 Psi, Will Handle Capacity up To 570 Lbs\/hr at Maximum. Choose a Model that Will Handle the Capacity Requirement Based on The Differential Pressure Across the Trap. Reference Capacity Charts.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eExample:\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eApplication: 100 Lbs\/hr at 75 Psig Working Pressure and 2 Psi Differential Pressure\u003c\/li\u003e \u003cli\u003eSize\/model: Ib1031, 80 Psig, Specify Pipe Size (1\/2\", 3\/4\"), or Ib1041, 80 Psig, Specify Pipe Size (3\/4\", 1\").\u003c\/li\u003e \u003c\/ul\u003e \u003ch2\u003eOptions\u003c\/h2\u003e \u003cp\u003eStrainer and Blowdown valve connection available on 1041, 1042, 1044 \u0026amp; 1038S. We also have 3 accessories for this trap are Thermic vent to improve air handling capability. Internal check valve for superheated or condensate backflow applications.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eHow to Order Accessories:\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eCheck Valve (Suffix \u003cstrong\u003eCV\u003c\/strong\u003e) Built-in Inlet Check Valve is recommended when used on Superheated Steam\u003cbr\u003e \u003cul\u003e \u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eCV\u003c\/strong\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003cli\u003eThermic Vent (Suffix \u003cstrong\u003eTV\u003c\/strong\u003e) A Thermic Vent is recommended when using a Bucket Trap on any type of process application or where the removal of air from the system is critical.\u003cbr\u003e \u003cul\u003e \u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTV\u003c\/strong\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003cli\u003eThermic Vent \u0026amp; Check Valve (Suffix \u003cstrong\u003eTCV\u003c\/strong\u003e) For combination of Check Valve \u0026amp; Thermic Vent\u003cbr\u003e \u003cul\u003e \u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTCV\u003c\/strong\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003ch2\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e \u003cp\u003eTrap must be installed in upright position to function properly. All working components can be replaced with the trap body remaining in-line. With superheated steam, a check valve should be installed at inlet or trap may lose prime. A replacement kit containing the lever and seat assembly is a more economical option than replacing the entire steam trap. Also available are replacement screens, gaskets and buckets. When ordering replacement lever and seat assemblies, specify model and operating pressure. See Replacement Parts and Kits Section for exact cross-reference to Armstrong PCA (Pressure Change Assembly) kits.\u003c\/p\u003e \u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e \u003cdiv class=\"tech\"\u003e \u003ch2\u003eTechnical Specifications\u003c\/h2\u003e \u003cdiv class=\"specs\"\u003e \u003cdiv class=\"column\"\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eModel\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e1031\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eSizes\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e3\/4\"\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eConnections\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eNPT\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eBody Material\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eCast Iron\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eInternal check valve, Thermic vent\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003ePMO Max. Operating Pressure\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e125 PSIG\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"column\"\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eTMO Max. Operating Temperature\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e450°F\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003ePMA Max. Allowable Pressure\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e250 PSIG up to 450°F\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eTMA Max. Allowable Temperature\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e450°F @ 250 PSIG\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eIB1031-13-N-125-TCV\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e \u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap-Spec-Sheet.pdf?v=1786494449\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"Watson McDaniel","offers":[{"title":"Default Title","offer_id":44165899288654,"sku":"IB1031-13-N-125-TCV","price":631.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap__98498.1784299743.1280.1280.jpg?v=1786663419"},{"product_id":"watson-mcdaniel-ib1031-series-inverted-bucket-steam-trap-cast-iron-body-150-psig-in-line-repairability-3-4-npt","title":"Watson McDaniel IB1031 Series Inverted Bucket Steam Trap, Cast Iron Body, 150 PSIG, In-line Repairability, 3\/4\" NPT","description":"\u003ch2\u003eWatson McDaniel IB1031 Series Inverted Bucket Steam Trap - 3\/4\" NPT (150 PSIG)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWaterhammer Resistant\u003c\/li\u003e\n\u003cli\u003eSuitable for superheated steam (use internal check valve option to eliminate loss of prime)\u003c\/li\u003e\n\u003cli\u003eIn-line repairability is simplified by having all internals attached to the cover\u003c\/li\u003e\n\u003cli\u003eValve \u0026amp; seat are located at the top of the trap body making them less prone to clogging from debris and pipe scale\u003c\/li\u003e\n\u003cli\u003eAll stainless steel internals with hardened valve \u0026amp; seat\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eIB1031 Series\u003c\/h2\u003e\u003cp\u003eThe IB1031 series is the smallest of the IB series. It has a max operating pressure (PMO) of up to 150 PSIG and at max differential pressure, it can handle up to 690 lbs\/hr of condensate.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDRIP, TRACING, PROCESS:\u003c\/strong\u003e IB Series inverted bucket steam traps are used in drip applications to remove condensate from steam mains and steam supply lines. For drip applications, the smaller sized units have adequate capacity. The discharge orifice of the inverted bucket trap is mounted at the top of the trap body, which makes them less susceptible to failure from dirt and debris when compared to other trap types. Since Inverted Bucket traps have poor air-handling capability, they are normally not recommended for most process applications. However, they can be used on certain process applications such as unit heaters and laundry equipment,where discharging air during system start-up is not a critical factor. F\u0026amp;T traps are the preferred choice for systems where air must be quickly discharged.\u003c\/p\u003e\u003ch2\u003eHow It Works\u003c\/h2\u003e\u003cp\u003eWhen the trap is filled with condensate, the inverted bucket inside the steam trap loses its buoyancy and rests on the bottom of the trap. This pulls the disc off the seat allowing condensate to be discharged through the seat orifice located at the top of the trap. When steam enters, it fills the inverted bucket causing the bucket to float to the surface which closes the discharge valve, containing the steam in the system. Eventually, the steam is bled off through a small hole in the top of the bucket causing it to sink, which repeats the cycle.\u003c\/p\u003e\u003ch2\u003eSelection \/ Sizing \/ Capacities\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eSelect A Model With A Higher Maximum Operating Pressure (PMO)\u003c\/strong\u003e that Meet or Exceed the Maximum Steam Pressure or The Trap May Not Open. for Example, the Ib-1031-13-N-150 Has a Max Pmo of 150 Psi, Will Handle Capacity up To 570 Lbs\/hr at Maximum. Choose a Model that Will Handle the Capacity Requirement Based on The Differential Pressure Across the Trap. Reference Capacity Charts.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eExample:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eApplication: 100 Lbs\/hr at 75 Psig Working Pressure and 2 Psi Differential Pressure\u003c\/li\u003e\n\u003cli\u003eSize\/model: Ib1031, 80 Psig, Specify Pipe Size (1\/2\", 3\/4\"), or Ib1041, 80 Psig, Specify Pipe Size (3\/4\", 1\").\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eOptions\u003c\/h2\u003e\u003cp\u003eStrainer and Blowdown valve connection available on 1041, 1042, 1044 \u0026amp; 1038S. We also have 3 accessories for this trap are Thermic vent to improve air handling capability. Internal check valve for superheated or condensate backflow applications.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow to Order Accessories:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCheck Valve (Suffix \u003cstrong\u003eCV\u003c\/strong\u003e) Built-in Inlet Check Valve is recommended when used on Superheated Steam\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent (Suffix \u003cstrong\u003eTV\u003c\/strong\u003e) A Thermic Vent is recommended when using a Bucket Trap on any type of process application or where the removal of air from the system is critical.\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent \u0026amp; Check Valve (Suffix \u003cstrong\u003eTCV\u003c\/strong\u003e) For combination of Check Valve \u0026amp; Thermic Vent\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e\u003cp\u003eTrap must be installed in upright position to function properly. All working components can be replaced with the trap body remaining in-line. With superheated steam, a check valve should be installed at inlet or trap may lose prime. A replacement kit containing the lever and seat assembly is a more economical option than replacing the entire steam trap. Also available are replacement screens, gaskets and buckets. When ordering replacement lever and seat assemblies, specify model and operating pressure. See Replacement Parts and Kits Section for exact cross-reference to Armstrong PCA (Pressure Change Assembly) kits.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eModel\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1031\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSizes\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e3\/4\"\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eConnections\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eNPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Material\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eCast Iron\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eInternal check valve, Thermic vent\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMO Max. Operating Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMO Max. Operating Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMA Max. Allowable Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 PSIG up to 450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMA Max. Allowable Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F @ 250 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap-Spec-Sheet.pdf?v=1786494449\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"Watson McDaniel","offers":[{"title":"Default Title","offer_id":44165899354190,"sku":"WM-IB1031-34-150","price":217.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap__33169.1784299743.1280.1280.jpg?v=1786663421"},{"product_id":"watson-mcdaniel-ib1031-13-n-150-inverted-bucket-steam-trap-cast-iron-body-150-psig-in-line-repairability-npt","title":"Watson McDaniel IB1031-13-N-150 Inverted Bucket Steam Trap, Cast Iron Body, 150 PSIG, In-line Repairability, NPT","description":"\u003ch2\u003eWatson McDaniel IB1031-13-N-150 Inverted Bucket Steam Trap - 3\/4\" NPT (150 PSIG)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWaterhammer Resistant\u003c\/li\u003e\n\u003cli\u003eSuitable for superheated steam (use internal check valve option to eliminate loss of prime)\u003c\/li\u003e\n\u003cli\u003eIn-line repairability is simplified by having all internals attached to the cover\u003c\/li\u003e\n\u003cli\u003eValve \u0026amp; seat are located at the top of the trap body making them less prone to clogging from debris and pipe scale\u003c\/li\u003e\n\u003cli\u003eAll stainless steel internals with hardened valve \u0026amp; seat\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eIB1031 Series\u003c\/h2\u003e\u003cp\u003eThe IB1031 series is the smallest of the IB series. It has a max operating pressure (PMO) of up to 150 PSIG and at max differential pressure, it can handle up to 690 lbs\/hr of condensate.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDRIP, TRACING, PROCESS:\u003c\/strong\u003e IB Series inverted bucket steam traps are used in drip applications to remove condensate from steam mains and steam supply lines. For drip applications, the smaller sized units have adequate capacity. The discharge orifice of the inverted bucket trap is mounted at the top of the trap body, which makes them less susceptible to failure from dirt and debris when compared to other trap types. Since Inverted Bucket traps have poor air-handling capability, they are normally not recommended for most process applications. However, they can be used on certain process applications such as unit heaters and laundry equipment,where discharging air during system start-up is not a critical factor. F\u0026amp;T traps are the preferred choice for systems where air must be quickly discharged.\u003c\/p\u003e\u003ch2\u003eHow It Works\u003c\/h2\u003e\u003cp\u003eWhen the trap is filled with condensate, the inverted bucket inside the steam trap loses its buoyancy and rests on the bottom of the trap. This pulls the disc off the seat allowing condensate to be discharged through the seat orifice located at the top of the trap. When steam enters, it fills the inverted bucket causing the bucket to float to the surface which closes the discharge valve, containing the steam in the system. Eventually, the steam is bled off through a small hole in the top of the bucket causing it to sink, which repeats the cycle.\u003c\/p\u003e\u003ch2\u003eSelection \/ Sizing \/ Capacities\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eSelect A Model With A Higher Maximum Operating Pressure (PMO)\u003c\/strong\u003e that Meet or Exceed the Maximum Steam Pressure or The Trap May Not Open. for Example, the Ib-1031-13-N-150 Has a Max Pmo of 150 Psi, Will Handle Capacity up To 570 Lbs\/hr at Maximum. Choose a Model that Will Handle the Capacity Requirement Based on The Differential Pressure Across the Trap. Reference Capacity Charts.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eExample:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eApplication: 100 Lbs\/hr at 75 Psig Working Pressure and 2 Psi Differential Pressure\u003c\/li\u003e\n\u003cli\u003eSize\/model: Ib1031, 80 Psig, Specify Pipe Size (1\/2\", 3\/4\"), or Ib1041, 80 Psig, Specify Pipe Size (3\/4\", 1\").\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eOptions\u003c\/h2\u003e\u003cp\u003eStrainer and Blowdown valve connection available on 1041, 1042, 1044 \u0026amp; 1038S. We also have 3 accessories for this trap are Thermic vent to improve air handling capability. Internal check valve for superheated or condensate backflow applications.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow to Order Accessories:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCheck Valve (Suffix \u003cstrong\u003eCV\u003c\/strong\u003e) Built-in Inlet Check Valve is recommended when used on Superheated Steam\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent (Suffix \u003cstrong\u003eTV\u003c\/strong\u003e) A Thermic Vent is recommended when using a Bucket Trap on any type of process application or where the removal of air from the system is critical.\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent \u0026amp; Check Valve (Suffix \u003cstrong\u003eTCV\u003c\/strong\u003e) For combination of Check Valve \u0026amp; Thermic Vent\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e\u003cp\u003eTrap must be installed in upright position to function properly. All working components can be replaced with the trap body remaining in-line. With superheated steam, a check valve should be installed at inlet or trap may lose prime. A replacement kit containing the lever and seat assembly is a more economical option than replacing the entire steam trap. Also available are replacement screens, gaskets and buckets. When ordering replacement lever and seat assemblies, specify model and operating pressure. See Replacement Parts and Kits Section for exact cross-reference to Armstrong PCA (Pressure Change Assembly) kits.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eModel\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1031\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSizes\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e3\/4\"\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eConnections\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eNPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Material\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eCast Iron\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eInternal check valve, Thermic vent\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMO Max. Operating Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMO Max. Operating Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMA Max. Allowable Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 PSIG up to 450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMA Max. Allowable Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F @ 250 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eIB1031-13-N-150\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap-Spec-Sheet.pdf?v=1786494449\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"Watson McDaniel","offers":[{"title":"Default Title","offer_id":44165899419726,"sku":"IB1031-13-N-150","price":217.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap__30909.1784299721.1280.1280.jpg?v=1786663423"},{"product_id":"watson-mcdaniel-ib1031-13-n-150-cv-inverted-bucket-steam-trap-cast-iron-body-150-psig-in-line-repairability-npt","title":"Watson McDaniel IB1031-13-N-150-CV Inverted Bucket Steam Trap, Cast Iron Body, 150 PSIG, In-line Repairability, NPT","description":"\u003ch2\u003eWatson McDaniel IB1031-13-N-150-CV Inverted Bucket Steam Trap - 3\/4\" NPT (150 PSIG)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWaterhammer Resistant\u003c\/li\u003e\n\u003cli\u003eSuitable for superheated steam (use internal check valve option to eliminate loss of prime)\u003c\/li\u003e\n\u003cli\u003eIn-line repairability is simplified by having all internals attached to the cover\u003c\/li\u003e\n\u003cli\u003eValve \u0026amp; seat are located at the top of the trap body making them less prone to clogging from debris and pipe scale\u003c\/li\u003e\n\u003cli\u003eAll stainless steel internals with hardened valve \u0026amp; seat\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eIB1031 Series\u003c\/h2\u003e\u003cp\u003eThe IB1031 series is the smallest of the IB series. It has a max operating pressure (PMO) of up to 150 PSIG and at max differential pressure, it can handle up to 690 lbs\/hr of condensate.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDRIP, TRACING, PROCESS:\u003c\/strong\u003e IB Series inverted bucket steam traps are used in drip applications to remove condensate from steam mains and steam supply lines. For drip applications, the smaller sized units have adequate capacity. The discharge orifice of the inverted bucket trap is mounted at the top of the trap body, which makes them less susceptible to failure from dirt and debris when compared to other trap types. Since Inverted Bucket traps have poor air-handling capability, they are normally not recommended for most process applications. However, they can be used on certain process applications such as unit heaters and laundry equipment,where discharging air during system start-up is not a critical factor. F\u0026amp;T traps are the preferred choice for systems where air must be quickly discharged.\u003c\/p\u003e\u003ch2\u003eHow It Works\u003c\/h2\u003e\u003cp\u003eWhen the trap is filled with condensate, the inverted bucket inside the steam trap loses its buoyancy and rests on the bottom of the trap. This pulls the disc off the seat allowing condensate to be discharged through the seat orifice located at the top of the trap. When steam enters, it fills the inverted bucket causing the bucket to float to the surface which closes the discharge valve, containing the steam in the system. Eventually, the steam is bled off through a small hole in the top of the bucket causing it to sink, which repeats the cycle.\u003c\/p\u003e\u003ch2\u003eSelection \/ Sizing \/ Capacities\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eSelect A Model With A Higher Maximum Operating Pressure (PMO)\u003c\/strong\u003e that Meet or Exceed the Maximum Steam Pressure or The Trap May Not Open. for Example, the Ib-1031-13-N-150 Has a Max Pmo of 150 Psi, Will Handle Capacity up To 570 Lbs\/hr at Maximum. Choose a Model that Will Handle the Capacity Requirement Based on The Differential Pressure Across the Trap. Reference Capacity Charts.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eExample:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eApplication: 100 Lbs\/hr at 75 Psig Working Pressure and 2 Psi Differential Pressure\u003c\/li\u003e\n\u003cli\u003eSize\/model: Ib1031, 80 Psig, Specify Pipe Size (1\/2\", 3\/4\"), or Ib1041, 80 Psig, Specify Pipe Size (3\/4\", 1\").\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eOptions\u003c\/h2\u003e\u003cp\u003eStrainer and Blowdown valve connection available on 1041, 1042, 1044 \u0026amp; 1038S. We also have 3 accessories for this trap are Thermic vent to improve air handling capability. Internal check valve for superheated or condensate backflow applications.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow to Order Accessories:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCheck Valve (Suffix \u003cstrong\u003eCV\u003c\/strong\u003e) Built-in Inlet Check Valve is recommended when used on Superheated Steam\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent (Suffix \u003cstrong\u003eTV\u003c\/strong\u003e) A Thermic Vent is recommended when using a Bucket Trap on any type of process application or where the removal of air from the system is critical.\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent \u0026amp; Check Valve (Suffix \u003cstrong\u003eTCV\u003c\/strong\u003e) For combination of Check Valve \u0026amp; Thermic Vent\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e\u003cp\u003eTrap must be installed in upright position to function properly. All working components can be replaced with the trap body remaining in-line. With superheated steam, a check valve should be installed at inlet or trap may lose prime. A replacement kit containing the lever and seat assembly is a more economical option than replacing the entire steam trap. Also available are replacement screens, gaskets and buckets. When ordering replacement lever and seat assemblies, specify model and operating pressure. See Replacement Parts and Kits Section for exact cross-reference to Armstrong PCA (Pressure Change Assembly) kits.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eModel\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1031\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSizes\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e3\/4\"\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eConnections\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eNPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Material\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eCast Iron\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eInternal check valve, Thermic vent\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMO Max. Operating Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMO Max. Operating Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMA Max. Allowable Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 PSIG up to 450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMA Max. Allowable Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F @ 250 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eIB1031-13-N-150-CV\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap-Spec-Sheet.pdf?v=1786494449\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"Watson McDaniel","offers":[{"title":"Default Title","offer_id":44165899485262,"sku":"IB1031-13-N-150-CV","price":364.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap__11621.1784299743.1280.1280.jpg?v=1786663426"},{"product_id":"watson-mcdaniel-ib1031-13-n-150-tv-inverted-bucket-steam-trap-cast-iron-body-150-psig-in-line-repairability-npt","title":"Watson McDaniel IB1031-13-N-150-TV Inverted Bucket Steam Trap, Cast Iron Body, 150 PSIG, In-line Repairability, NPT","description":"\u003ch2\u003eWatson McDaniel IB1031-13-N-150-TV Inverted Bucket Steam Trap - 3\/4\" NPT (150 PSIG)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWaterhammer Resistant\u003c\/li\u003e\n\u003cli\u003eSuitable for superheated steam (use internal check valve option to eliminate loss of prime)\u003c\/li\u003e\n\u003cli\u003eIn-line repairability is simplified by having all internals attached to the cover\u003c\/li\u003e\n\u003cli\u003eValve \u0026amp; seat are located at the top of the trap body making them less prone to clogging from debris and pipe scale\u003c\/li\u003e\n\u003cli\u003eAll stainless steel internals with hardened valve \u0026amp; seat\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eIB1031 Series\u003c\/h2\u003e\u003cp\u003eThe IB1031 series is the smallest of the IB series. It has a max operating pressure (PMO) of up to 150 PSIG and at max differential pressure, it can handle up to 690 lbs\/hr of condensate.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDRIP, TRACING, PROCESS:\u003c\/strong\u003e IB Series inverted bucket steam traps are used in drip applications to remove condensate from steam mains and steam supply lines. For drip applications, the smaller sized units have adequate capacity. The discharge orifice of the inverted bucket trap is mounted at the top of the trap body, which makes them less susceptible to failure from dirt and debris when compared to other trap types. Since Inverted Bucket traps have poor air-handling capability, they are normally not recommended for most process applications. However, they can be used on certain process applications such as unit heaters and laundry equipment,where discharging air during system start-up is not a critical factor. F\u0026amp;T traps are the preferred choice for systems where air must be quickly discharged.\u003c\/p\u003e\u003ch2\u003eHow It Works\u003c\/h2\u003e\u003cp\u003eWhen the trap is filled with condensate, the inverted bucket inside the steam trap loses its buoyancy and rests on the bottom of the trap. This pulls the disc off the seat allowing condensate to be discharged through the seat orifice located at the top of the trap. When steam enters, it fills the inverted bucket causing the bucket to float to the surface which closes the discharge valve, containing the steam in the system. Eventually, the steam is bled off through a small hole in the top of the bucket causing it to sink, which repeats the cycle.\u003c\/p\u003e\u003ch2\u003eSelection \/ Sizing \/ Capacities\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eSelect A Model With A Higher Maximum Operating Pressure (PMO)\u003c\/strong\u003e that Meet or Exceed the Maximum Steam Pressure or The Trap May Not Open. for Example, the Ib-1031-13-N-150 Has a Max Pmo of 150 Psi, Will Handle Capacity up To 570 Lbs\/hr at Maximum. Choose a Model that Will Handle the Capacity Requirement Based on The Differential Pressure Across the Trap. Reference Capacity Charts.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eExample:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eApplication: 100 Lbs\/hr at 75 Psig Working Pressure and 2 Psi Differential Pressure\u003c\/li\u003e\n\u003cli\u003eSize\/model: Ib1031, 80 Psig, Specify Pipe Size (1\/2\", 3\/4\"), or Ib1041, 80 Psig, Specify Pipe Size (3\/4\", 1\").\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eOptions\u003c\/h2\u003e\u003cp\u003eStrainer and Blowdown valve connection available on 1041, 1042, 1044 \u0026amp; 1038S. We also have 3 accessories for this trap are Thermic vent to improve air handling capability. Internal check valve for superheated or condensate backflow applications.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow to Order Accessories:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCheck Valve (Suffix \u003cstrong\u003eCV\u003c\/strong\u003e) Built-in Inlet Check Valve is recommended when used on Superheated Steam\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent (Suffix \u003cstrong\u003eTV\u003c\/strong\u003e) A Thermic Vent is recommended when using a Bucket Trap on any type of process application or where the removal of air from the system is critical.\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent \u0026amp; Check Valve (Suffix \u003cstrong\u003eTCV\u003c\/strong\u003e) For combination of Check Valve \u0026amp; Thermic Vent\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e\u003cp\u003eTrap must be installed in upright position to function properly. All working components can be replaced with the trap body remaining in-line. With superheated steam, a check valve should be installed at inlet or trap may lose prime. A replacement kit containing the lever and seat assembly is a more economical option than replacing the entire steam trap. Also available are replacement screens, gaskets and buckets. When ordering replacement lever and seat assemblies, specify model and operating pressure. See Replacement Parts and Kits Section for exact cross-reference to Armstrong PCA (Pressure Change Assembly) kits.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eModel\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1031\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSizes\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e3\/4\"\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eConnections\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eNPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Material\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eCast Iron\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eInternal check valve, Thermic vent\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMO Max. Operating Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMO Max. Operating Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMA Max. Allowable Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 PSIG up to 450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMA Max. Allowable Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F @ 250 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eIB1031-13-N-150-TV\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap-Spec-Sheet.pdf?v=1786494449\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"Watson McDaniel","offers":[{"title":"Default Title","offer_id":44165899583566,"sku":"IB1031-13-N-150-TV","price":435.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap__76415.1784299743.1280.1280.jpg?v=1786663429"},{"product_id":"watson-mcdaniel-ib1031-13-n-150-tcv-inverted-bucket-steam-trap-cast-iron-body-150-psig-in-line-repairability-npt","title":"Watson McDaniel IB1031-13-N-150-TCV Inverted Bucket Steam Trap, Cast Iron Body, 150 PSIG, In-line Repairability, NPT","description":"\u003ch2\u003eWatson McDaniel IB1031-13-N-150-TCV Inverted Bucket Steam Trap - 3\/4\" NPT (150 PSIG)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWaterhammer Resistant\u003c\/li\u003e\n\u003cli\u003eSuitable for superheated steam (use internal check valve option to eliminate loss of prime)\u003c\/li\u003e\n\u003cli\u003eIn-line repairability is simplified by having all internals attached to the cover\u003c\/li\u003e\n\u003cli\u003eValve \u0026amp; seat are located at the top of the trap body making them less prone to clogging from debris and pipe scale\u003c\/li\u003e\n\u003cli\u003eAll stainless steel internals with hardened valve \u0026amp; seat\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eIB1031 Series\u003c\/h2\u003e\u003cp\u003eThe IB1031 series is the smallest of the IB series. It has a max operating pressure (PMO) of up to 150 PSIG and at max differential pressure, it can handle up to 690 lbs\/hr of condensate.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDRIP, TRACING, PROCESS:\u003c\/strong\u003e IB Series inverted bucket steam traps are used in drip applications to remove condensate from steam mains and steam supply lines. For drip applications, the smaller sized units have adequate capacity. The discharge orifice of the inverted bucket trap is mounted at the top of the trap body, which makes them less susceptible to failure from dirt and debris when compared to other trap types. Since Inverted Bucket traps have poor air-handling capability, they are normally not recommended for most process applications. However, they can be used on certain process applications such as unit heaters and laundry equipment,where discharging air during system start-up is not a critical factor. F\u0026amp;T traps are the preferred choice for systems where air must be quickly discharged.\u003c\/p\u003e\u003ch2\u003eHow It Works\u003c\/h2\u003e\u003cp\u003eWhen the trap is filled with condensate, the inverted bucket inside the steam trap loses its buoyancy and rests on the bottom of the trap. This pulls the disc off the seat allowing condensate to be discharged through the seat orifice located at the top of the trap. When steam enters, it fills the inverted bucket causing the bucket to float to the surface which closes the discharge valve, containing the steam in the system. Eventually, the steam is bled off through a small hole in the top of the bucket causing it to sink, which repeats the cycle.\u003c\/p\u003e\u003ch2\u003eSelection \/ Sizing \/ Capacities\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eSelect A Model With A Higher Maximum Operating Pressure (PMO)\u003c\/strong\u003e that Meet or Exceed the Maximum Steam Pressure or The Trap May Not Open. for Example, the Ib-1031-13-N-150 Has a Max Pmo of 150 Psi, Will Handle Capacity up To 570 Lbs\/hr at Maximum. Choose a Model that Will Handle the Capacity Requirement Based on The Differential Pressure Across the Trap. Reference Capacity Charts.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eExample:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eApplication: 100 Lbs\/hr at 75 Psig Working Pressure and 2 Psi Differential Pressure\u003c\/li\u003e\n\u003cli\u003eSize\/model: Ib1031, 80 Psig, Specify Pipe Size (1\/2\", 3\/4\"), or Ib1041, 80 Psig, Specify Pipe Size (3\/4\", 1\").\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eOptions\u003c\/h2\u003e\u003cp\u003eStrainer and Blowdown valve connection available on 1041, 1042, 1044 \u0026amp; 1038S. We also have 3 accessories for this trap are Thermic vent to improve air handling capability. Internal check valve for superheated or condensate backflow applications.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow to Order Accessories:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCheck Valve (Suffix \u003cstrong\u003eCV\u003c\/strong\u003e) Built-in Inlet Check Valve is recommended when used on Superheated Steam\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent (Suffix \u003cstrong\u003eTV\u003c\/strong\u003e) A Thermic Vent is recommended when using a Bucket Trap on any type of process application or where the removal of air from the system is critical.\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent \u0026amp; Check Valve (Suffix \u003cstrong\u003eTCV\u003c\/strong\u003e) For combination of Check Valve \u0026amp; Thermic Vent\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e\u003cp\u003eTrap must be installed in upright position to function properly. All working components can be replaced with the trap body remaining in-line. With superheated steam, a check valve should be installed at inlet or trap may lose prime. A replacement kit containing the lever and seat assembly is a more economical option than replacing the entire steam trap. Also available are replacement screens, gaskets and buckets. When ordering replacement lever and seat assemblies, specify model and operating pressure. See Replacement Parts and Kits Section for exact cross-reference to Armstrong PCA (Pressure Change Assembly) kits.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eModel\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1031\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSizes\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e3\/4\"\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eConnections\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eNPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Material\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eCast Iron\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eInternal check valve, Thermic vent\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMO Max. Operating Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMO Max. Operating Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMA Max. Allowable Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 PSIG up to 450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMA Max. Allowable Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F @ 250 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eIB1031-13-N-150-TCV\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap-Spec-Sheet.pdf?v=1786494449\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"Watson McDaniel","offers":[{"title":"Default Title","offer_id":44165899649102,"sku":"IB1031-13-N-150-TCV","price":631.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap__71605.1784299743.1280.1280.jpg?v=1786663431"},{"product_id":"watson-mcdaniel-ib1031-series-inverted-bucket-steam-trap-cast-iron-body-20-psig-in-line-repairability-3-4-npt","title":"Watson McDaniel IB1031 Series Inverted Bucket Steam Trap, Cast Iron Body, 20 PSIG, In-line Repairability, 3\/4\" NPT","description":"\u003ch2\u003eWatson McDaniel IB1031 Series Inverted Bucket Steam Trap - 3\/4\" NPT (20 PSIG)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWaterhammer Resistant\u003c\/li\u003e\n\u003cli\u003eSuitable for superheated steam (use internal check valve option to eliminate loss of prime)\u003c\/li\u003e\n\u003cli\u003eIn-line repairability is simplified by having all internals attached to the cover\u003c\/li\u003e\n\u003cli\u003eValve \u0026amp; seat are located at the top of the trap body making them less prone to clogging from debris and pipe scale\u003c\/li\u003e\n\u003cli\u003eAll stainless steel internals with hardened valve \u0026amp; seat\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eIB1031 Series\u003c\/h2\u003e\u003cp\u003eThe IB1031 series is the smallest of the IB series. It has a max operating pressure (PMO) of up to 150 PSIG and at max differential pressure, it can handle up to 690 lbs\/hr of condensate.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDRIP, TRACING, PROCESS:\u003c\/strong\u003e IB Series inverted bucket steam traps are used in drip applications to remove condensate from steam mains and steam supply lines. For drip applications, the smaller sized units have adequate capacity. The discharge orifice of the inverted bucket trap is mounted at the top of the trap body, which makes them less susceptible to failure from dirt and debris when compared to other trap types. Since Inverted Bucket traps have poor air-handling capability, they are normally not recommended for most process applications. However, they can be used on certain process applications such as unit heaters and laundry equipment,where discharging air during system start-up is not a critical factor. F\u0026amp;T traps are the preferred choice for systems where air must be quickly discharged.\u003c\/p\u003e\u003ch2\u003eHow It Works\u003c\/h2\u003e\u003cp\u003eWhen the trap is filled with condensate, the inverted bucket inside the steam trap loses its buoyancy and rests on the bottom of the trap. This pulls the disc off the seat allowing condensate to be discharged through the seat orifice located at the top of the trap. When steam enters, it fills the inverted bucket causing the bucket to float to the surface which closes the discharge valve, containing the steam in the system. Eventually, the steam is bled off through a small hole in the top of the bucket causing it to sink, which repeats the cycle.\u003c\/p\u003e\u003ch2\u003eSelection \/ Sizing \/ Capacities\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eSelect A Model With A Higher Maximum Operating Pressure (PMO)\u003c\/strong\u003e that Meet or Exceed the Maximum Steam Pressure or The Trap May Not Open. for Example, the Ib-1031-13-N-150 Has a Max Pmo of 150 Psi, Will Handle Capacity up To 570 Lbs\/hr at Maximum. Choose a Model that Will Handle the Capacity Requirement Based on The Differential Pressure Across the Trap. Reference Capacity Charts.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eExample:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eApplication: 100 Lbs\/hr at 75 Psig Working Pressure and 2 Psi Differential Pressure\u003c\/li\u003e\n\u003cli\u003eSize\/model: Ib1031, 80 Psig, Specify Pipe Size (1\/2\", 3\/4\"), or Ib1041, 80 Psig, Specify Pipe Size (3\/4\", 1\").\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eOptions\u003c\/h2\u003e\u003cp\u003eStrainer and Blowdown valve connection available on 1041, 1042, 1044 \u0026amp; 1038S. We also have 3 accessories for this trap are Thermic vent to improve air handling capability. Internal check valve for superheated or condensate backflow applications.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow to Order Accessories:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCheck Valve (Suffix \u003cstrong\u003eCV\u003c\/strong\u003e) Built-in Inlet Check Valve is recommended when used on Superheated Steam\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent (Suffix \u003cstrong\u003eTV\u003c\/strong\u003e) A Thermic Vent is recommended when using a Bucket Trap on any type of process application or where the removal of air from the system is critical.\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent \u0026amp; Check Valve (Suffix \u003cstrong\u003eTCV\u003c\/strong\u003e) For combination of Check Valve \u0026amp; Thermic Vent\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e\u003cp\u003eTrap must be installed in upright position to function properly. All working components can be replaced with the trap body remaining in-line. With superheated steam, a check valve should be installed at inlet or trap may lose prime. A replacement kit containing the lever and seat assembly is a more economical option than replacing the entire steam trap. Also available are replacement screens, gaskets and buckets. When ordering replacement lever and seat assemblies, specify model and operating pressure. See Replacement Parts and Kits Section for exact cross-reference to Armstrong PCA (Pressure Change Assembly) kits.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eModel\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1031\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSizes\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e3\/4\"\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eConnections\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eNPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Material\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eCast Iron\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eInternal check valve, Thermic vent\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMO Max. Operating Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e20 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMO Max. Operating Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMA Max. Allowable Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 PSIG up to 450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMA Max. Allowable Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F @ 250 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap-Spec-Sheet.pdf?v=1786494449\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"Watson McDaniel","offers":[{"title":"Default Title","offer_id":44165899714638,"sku":"WM-IB1031-34-020","price":217.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap__66667.1784299744.1280.1280.jpg?v=1786663434"},{"product_id":"watson-mcdaniel-ib1031-13-n-020-inverted-bucket-steam-trap-cast-iron-body-20-psig-in-line-repairability-npt","title":"Watson McDaniel IB1031-13-N-020 Inverted Bucket Steam Trap, Cast Iron Body, 20 PSIG, In-line Repairability, NPT","description":"\u003ch2\u003eWatson McDaniel IB1031-13-N-020 Inverted Bucket Steam Trap - 3\/4\" NPT (20 PSIG)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWaterhammer Resistant\u003c\/li\u003e\n\u003cli\u003eSuitable for superheated steam (use internal check valve option to eliminate loss of prime)\u003c\/li\u003e\n\u003cli\u003eIn-line repairability is simplified by having all internals attached to the cover\u003c\/li\u003e\n\u003cli\u003eValve \u0026amp; seat are located at the top of the trap body making them less prone to clogging from debris and pipe scale\u003c\/li\u003e\n\u003cli\u003eAll stainless steel internals with hardened valve \u0026amp; seat\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eIB1031 Series\u003c\/h2\u003e\u003cp\u003eThe IB1031 series is the smallest of the IB series. It has a max operating pressure (PMO) of up to 150 PSIG and at max differential pressure, it can handle up to 690 lbs\/hr of condensate.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDRIP, TRACING, PROCESS:\u003c\/strong\u003e IB Series inverted bucket steam traps are used in drip applications to remove condensate from steam mains and steam supply lines. For drip applications, the smaller sized units have adequate capacity. The discharge orifice of the inverted bucket trap is mounted at the top of the trap body, which makes them less susceptible to failure from dirt and debris when compared to other trap types. Since Inverted Bucket traps have poor air-handling capability, they are normally not recommended for most process applications. However, they can be used on certain process applications such as unit heaters and laundry equipment,where discharging air during system start-up is not a critical factor. F\u0026amp;T traps are the preferred choice for systems where air must be quickly discharged.\u003c\/p\u003e\u003ch2\u003eHow It Works\u003c\/h2\u003e\u003cp\u003eWhen the trap is filled with condensate, the inverted bucket inside the steam trap loses its buoyancy and rests on the bottom of the trap. This pulls the disc off the seat allowing condensate to be discharged through the seat orifice located at the top of the trap. When steam enters, it fills the inverted bucket causing the bucket to float to the surface which closes the discharge valve, containing the steam in the system. Eventually, the steam is bled off through a small hole in the top of the bucket causing it to sink, which repeats the cycle.\u003c\/p\u003e\u003ch2\u003eSelection \/ Sizing \/ Capacities\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eSelect A Model With A Higher Maximum Operating Pressure (PMO)\u003c\/strong\u003e that Meet or Exceed the Maximum Steam Pressure or The Trap May Not Open. for Example, the Ib-1031-13-N-150 Has a Max Pmo of 150 Psi, Will Handle Capacity up To 570 Lbs\/hr at Maximum. Choose a Model that Will Handle the Capacity Requirement Based on The Differential Pressure Across the Trap. Reference Capacity Charts.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eExample:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eApplication: 100 Lbs\/hr at 75 Psig Working Pressure and 2 Psi Differential Pressure\u003c\/li\u003e\n\u003cli\u003eSize\/model: Ib1031, 80 Psig, Specify Pipe Size (1\/2\", 3\/4\"), or Ib1041, 80 Psig, Specify Pipe Size (3\/4\", 1\").\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eOptions\u003c\/h2\u003e\u003cp\u003eStrainer and Blowdown valve connection available on 1041, 1042, 1044 \u0026amp; 1038S. We also have 3 accessories for this trap are Thermic vent to improve air handling capability. Internal check valve for superheated or condensate backflow applications.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow to Order Accessories:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCheck Valve (Suffix \u003cstrong\u003eCV\u003c\/strong\u003e) Built-in Inlet Check Valve is recommended when used on Superheated Steam\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent (Suffix \u003cstrong\u003eTV\u003c\/strong\u003e) A Thermic Vent is recommended when using a Bucket Trap on any type of process application or where the removal of air from the system is critical.\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent \u0026amp; Check Valve (Suffix \u003cstrong\u003eTCV\u003c\/strong\u003e) For combination of Check Valve \u0026amp; Thermic Vent\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e\u003cp\u003eTrap must be installed in upright position to function properly. All working components can be replaced with the trap body remaining in-line. With superheated steam, a check valve should be installed at inlet or trap may lose prime. A replacement kit containing the lever and seat assembly is a more economical option than replacing the entire steam trap. Also available are replacement screens, gaskets and buckets. When ordering replacement lever and seat assemblies, specify model and operating pressure. See Replacement Parts and Kits Section for exact cross-reference to Armstrong PCA (Pressure Change Assembly) kits.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eModel\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1031\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSizes\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e3\/4\"\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eConnections\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eNPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Material\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eCast Iron\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eInternal check valve, Thermic vent\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMO Max. Operating Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e20 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMO Max. Operating Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMA Max. Allowable Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 PSIG up to 450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMA Max. Allowable Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F @ 250 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eIB1031-13-N-020\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap-Spec-Sheet.pdf?v=1786494449\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"Watson McDaniel","offers":[{"title":"Default Title","offer_id":44165899812942,"sku":"IB1031-13-N-020","price":217.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap__39593.1784299721.1280.1280.jpg?v=1786663436"},{"product_id":"watson-mcdaniel-ib1031-13-n-020-cv-inverted-bucket-steam-trap-cast-iron-body-20-psig-in-line-repairability-npt","title":"Watson McDaniel IB1031-13-N-020-CV Inverted Bucket Steam Trap, Cast Iron Body, 20 PSIG, In-line Repairability, NPT","description":"\u003ch2\u003eWatson McDaniel IB1031-13-N-020-CV Inverted Bucket Steam Trap - 3\/4\" NPT (20 PSIG)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWaterhammer Resistant\u003c\/li\u003e\n\u003cli\u003eSuitable for superheated steam (use internal check valve option to eliminate loss of prime)\u003c\/li\u003e\n\u003cli\u003eIn-line repairability is simplified by having all internals attached to the cover\u003c\/li\u003e\n\u003cli\u003eValve \u0026amp; seat are located at the top of the trap body making them less prone to clogging from debris and pipe scale\u003c\/li\u003e\n\u003cli\u003eAll stainless steel internals with hardened valve \u0026amp; seat\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eIB1031 Series\u003c\/h2\u003e\u003cp\u003eThe IB1031 series is the smallest of the IB series. It has a max operating pressure (PMO) of up to 150 PSIG and at max differential pressure, it can handle up to 690 lbs\/hr of condensate.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDRIP, TRACING, PROCESS:\u003c\/strong\u003e IB Series inverted bucket steam traps are used in drip applications to remove condensate from steam mains and steam supply lines. For drip applications, the smaller sized units have adequate capacity. The discharge orifice of the inverted bucket trap is mounted at the top of the trap body, which makes them less susceptible to failure from dirt and debris when compared to other trap types. Since Inverted Bucket traps have poor air-handling capability, they are normally not recommended for most process applications. However, they can be used on certain process applications such as unit heaters and laundry equipment,where discharging air during system start-up is not a critical factor. F\u0026amp;T traps are the preferred choice for systems where air must be quickly discharged.\u003c\/p\u003e\u003ch2\u003eHow It Works\u003c\/h2\u003e\u003cp\u003eWhen the trap is filled with condensate, the inverted bucket inside the steam trap loses its buoyancy and rests on the bottom of the trap. This pulls the disc off the seat allowing condensate to be discharged through the seat orifice located at the top of the trap. When steam enters, it fills the inverted bucket causing the bucket to float to the surface which closes the discharge valve, containing the steam in the system. Eventually, the steam is bled off through a small hole in the top of the bucket causing it to sink, which repeats the cycle.\u003c\/p\u003e\u003ch2\u003eSelection \/ Sizing \/ Capacities\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eSelect A Model With A Higher Maximum Operating Pressure (PMO)\u003c\/strong\u003e that Meet or Exceed the Maximum Steam Pressure or The Trap May Not Open. for Example, the Ib-1031-13-N-150 Has a Max Pmo of 150 Psi, Will Handle Capacity up To 570 Lbs\/hr at Maximum. Choose a Model that Will Handle the Capacity Requirement Based on The Differential Pressure Across the Trap. Reference Capacity Charts.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eExample:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eApplication: 100 Lbs\/hr at 75 Psig Working Pressure and 2 Psi Differential Pressure\u003c\/li\u003e\n\u003cli\u003eSize\/model: Ib1031, 80 Psig, Specify Pipe Size (1\/2\", 3\/4\"), or Ib1041, 80 Psig, Specify Pipe Size (3\/4\", 1\").\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eOptions\u003c\/h2\u003e\u003cp\u003eStrainer and Blowdown valve connection available on 1041, 1042, 1044 \u0026amp; 1038S. We also have 3 accessories for this trap are Thermic vent to improve air handling capability. Internal check valve for superheated or condensate backflow applications.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow to Order Accessories:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCheck Valve (Suffix \u003cstrong\u003eCV\u003c\/strong\u003e) Built-in Inlet Check Valve is recommended when used on Superheated Steam\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent (Suffix \u003cstrong\u003eTV\u003c\/strong\u003e) A Thermic Vent is recommended when using a Bucket Trap on any type of process application or where the removal of air from the system is critical.\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent \u0026amp; Check Valve (Suffix \u003cstrong\u003eTCV\u003c\/strong\u003e) For combination of Check Valve \u0026amp; Thermic Vent\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e\u003cp\u003eTrap must be installed in upright position to function properly. All working components can be replaced with the trap body remaining in-line. With superheated steam, a check valve should be installed at inlet or trap may lose prime. A replacement kit containing the lever and seat assembly is a more economical option than replacing the entire steam trap. Also available are replacement screens, gaskets and buckets. When ordering replacement lever and seat assemblies, specify model and operating pressure. See Replacement Parts and Kits Section for exact cross-reference to Armstrong PCA (Pressure Change Assembly) kits.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eModel\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1031\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSizes\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e3\/4\"\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eConnections\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eNPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Material\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eCast Iron\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eInternal check valve, Thermic vent\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMO Max. Operating Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e20 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMO Max. Operating Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMA Max. Allowable Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 PSIG up to 450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMA Max. Allowable Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F @ 250 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eIB1031-13-N-020-CV\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap-Spec-Sheet.pdf?v=1786494449\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"Watson McDaniel","offers":[{"title":"Default Title","offer_id":44165899911246,"sku":"IB1031-13-N-020-CV","price":364.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap__91590.1784299744.1280.1280.jpg?v=1786663439"},{"product_id":"watson-mcdaniel-ib1031-13-n-020-tv-inverted-bucket-steam-trap-cast-iron-body-20-psig-in-line-repairability-npt","title":"Watson McDaniel IB1031-13-N-020-TV Inverted Bucket Steam Trap, Cast Iron Body, 20 PSIG, In-line Repairability, NPT","description":"\u003ch2\u003eWatson McDaniel IB1031-13-N-020-TV Inverted Bucket Steam Trap - 3\/4\" NPT (20 PSIG)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWaterhammer Resistant\u003c\/li\u003e\n\u003cli\u003eSuitable for superheated steam (use internal check valve option to eliminate loss of prime)\u003c\/li\u003e\n\u003cli\u003eIn-line repairability is simplified by having all internals attached to the cover\u003c\/li\u003e\n\u003cli\u003eValve \u0026amp; seat are located at the top of the trap body making them less prone to clogging from debris and pipe scale\u003c\/li\u003e\n\u003cli\u003eAll stainless steel internals with hardened valve \u0026amp; seat\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eIB1031 Series\u003c\/h2\u003e\u003cp\u003eThe IB1031 series is the smallest of the IB series. It has a max operating pressure (PMO) of up to 150 PSIG and at max differential pressure, it can handle up to 690 lbs\/hr of condensate.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDRIP, TRACING, PROCESS:\u003c\/strong\u003e IB Series inverted bucket steam traps are used in drip applications to remove condensate from steam mains and steam supply lines. For drip applications, the smaller sized units have adequate capacity. The discharge orifice of the inverted bucket trap is mounted at the top of the trap body, which makes them less susceptible to failure from dirt and debris when compared to other trap types. Since Inverted Bucket traps have poor air-handling capability, they are normally not recommended for most process applications. However, they can be used on certain process applications such as unit heaters and laundry equipment,where discharging air during system start-up is not a critical factor. F\u0026amp;T traps are the preferred choice for systems where air must be quickly discharged.\u003c\/p\u003e\u003ch2\u003eHow It Works\u003c\/h2\u003e\u003cp\u003eWhen the trap is filled with condensate, the inverted bucket inside the steam trap loses its buoyancy and rests on the bottom of the trap. This pulls the disc off the seat allowing condensate to be discharged through the seat orifice located at the top of the trap. When steam enters, it fills the inverted bucket causing the bucket to float to the surface which closes the discharge valve, containing the steam in the system. Eventually, the steam is bled off through a small hole in the top of the bucket causing it to sink, which repeats the cycle.\u003c\/p\u003e\u003ch2\u003eSelection \/ Sizing \/ Capacities\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eSelect A Model With A Higher Maximum Operating Pressure (PMO)\u003c\/strong\u003e that Meet or Exceed the Maximum Steam Pressure or The Trap May Not Open. for Example, the Ib-1031-13-N-150 Has a Max Pmo of 150 Psi, Will Handle Capacity up To 570 Lbs\/hr at Maximum. Choose a Model that Will Handle the Capacity Requirement Based on The Differential Pressure Across the Trap. Reference Capacity Charts.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eExample:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eApplication: 100 Lbs\/hr at 75 Psig Working Pressure and 2 Psi Differential Pressure\u003c\/li\u003e\n\u003cli\u003eSize\/model: Ib1031, 80 Psig, Specify Pipe Size (1\/2\", 3\/4\"), or Ib1041, 80 Psig, Specify Pipe Size (3\/4\", 1\").\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eOptions\u003c\/h2\u003e\u003cp\u003eStrainer and Blowdown valve connection available on 1041, 1042, 1044 \u0026amp; 1038S. We also have 3 accessories for this trap are Thermic vent to improve air handling capability. Internal check valve for superheated or condensate backflow applications.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow to Order Accessories:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCheck Valve (Suffix \u003cstrong\u003eCV\u003c\/strong\u003e) Built-in Inlet Check Valve is recommended when used on Superheated Steam\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent (Suffix \u003cstrong\u003eTV\u003c\/strong\u003e) A Thermic Vent is recommended when using a Bucket Trap on any type of process application or where the removal of air from the system is critical.\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent \u0026amp; Check Valve (Suffix \u003cstrong\u003eTCV\u003c\/strong\u003e) For combination of Check Valve \u0026amp; Thermic Vent\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e\u003cp\u003eTrap must be installed in upright position to function properly. All working components can be replaced with the trap body remaining in-line. With superheated steam, a check valve should be installed at inlet or trap may lose prime. A replacement kit containing the lever and seat assembly is a more economical option than replacing the entire steam trap. Also available are replacement screens, gaskets and buckets. When ordering replacement lever and seat assemblies, specify model and operating pressure. See Replacement Parts and Kits Section for exact cross-reference to Armstrong PCA (Pressure Change Assembly) kits.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eModel\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1031\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSizes\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e3\/4\"\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eConnections\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eNPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Material\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eCast Iron\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eInternal check valve, Thermic vent\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMO Max. Operating Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e20 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMO Max. Operating Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMA Max. Allowable Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 PSIG up to 450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMA Max. Allowable Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F @ 250 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eIB1031-13-N-020-TV\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap-Spec-Sheet.pdf?v=1786494449\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"Watson McDaniel","offers":[{"title":"Default Title","offer_id":44165899976782,"sku":"IB1031-13-N-020-TV","price":435.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap__92827.1784299744.1280.1280.jpg?v=1786663441"},{"product_id":"watson-mcdaniel-ib1031-13-n-020-tcv-inverted-bucket-steam-trap-cast-iron-body-20-psig-in-line-repairability-npt","title":"Watson McDaniel IB1031-13-N-020-TCV Inverted Bucket Steam Trap, Cast Iron Body, 20 PSIG, In-line Repairability, NPT","description":"\u003ch2\u003eWatson McDaniel IB1031-13-N-020-TCV Inverted Bucket Steam Trap - 3\/4\" NPT (20 PSIG)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWaterhammer Resistant\u003c\/li\u003e\n\u003cli\u003eSuitable for superheated steam (use internal check valve option to eliminate loss of prime)\u003c\/li\u003e\n\u003cli\u003eIn-line repairability is simplified by having all internals attached to the cover\u003c\/li\u003e\n\u003cli\u003eValve \u0026amp; seat are located at the top of the trap body making them less prone to clogging from debris and pipe scale\u003c\/li\u003e\n\u003cli\u003eAll stainless steel internals with hardened valve \u0026amp; seat\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eIB1031 Series\u003c\/h2\u003e\u003cp\u003eThe IB1031 series is the smallest of the IB series. It has a max operating pressure (PMO) of up to 150 PSIG and at max differential pressure, it can handle up to 690 lbs\/hr of condensate.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDRIP, TRACING, PROCESS:\u003c\/strong\u003e IB Series inverted bucket steam traps are used in drip applications to remove condensate from steam mains and steam supply lines. For drip applications, the smaller sized units have adequate capacity. The discharge orifice of the inverted bucket trap is mounted at the top of the trap body, which makes them less susceptible to failure from dirt and debris when compared to other trap types. Since Inverted Bucket traps have poor air-handling capability, they are normally not recommended for most process applications. However, they can be used on certain process applications such as unit heaters and laundry equipment,where discharging air during system start-up is not a critical factor. F\u0026amp;T traps are the preferred choice for systems where air must be quickly discharged.\u003c\/p\u003e\u003ch2\u003eHow It Works\u003c\/h2\u003e\u003cp\u003eWhen the trap is filled with condensate, the inverted bucket inside the steam trap loses its buoyancy and rests on the bottom of the trap. This pulls the disc off the seat allowing condensate to be discharged through the seat orifice located at the top of the trap. When steam enters, it fills the inverted bucket causing the bucket to float to the surface which closes the discharge valve, containing the steam in the system. Eventually, the steam is bled off through a small hole in the top of the bucket causing it to sink, which repeats the cycle.\u003c\/p\u003e\u003ch2\u003eSelection \/ Sizing \/ Capacities\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eSelect A Model With A Higher Maximum Operating Pressure (PMO)\u003c\/strong\u003e that Meet or Exceed the Maximum Steam Pressure or The Trap May Not Open. for Example, the Ib-1031-13-N-150 Has a Max Pmo of 150 Psi, Will Handle Capacity up To 570 Lbs\/hr at Maximum. Choose a Model that Will Handle the Capacity Requirement Based on The Differential Pressure Across the Trap. Reference Capacity Charts.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eExample:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eApplication: 100 Lbs\/hr at 75 Psig Working Pressure and 2 Psi Differential Pressure\u003c\/li\u003e\n\u003cli\u003eSize\/model: Ib1031, 80 Psig, Specify Pipe Size (1\/2\", 3\/4\"), or Ib1041, 80 Psig, Specify Pipe Size (3\/4\", 1\").\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eOptions\u003c\/h2\u003e\u003cp\u003eStrainer and Blowdown valve connection available on 1041, 1042, 1044 \u0026amp; 1038S. We also have 3 accessories for this trap are Thermic vent to improve air handling capability. Internal check valve for superheated or condensate backflow applications.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow to Order Accessories:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCheck Valve (Suffix \u003cstrong\u003eCV\u003c\/strong\u003e) Built-in Inlet Check Valve is recommended when used on Superheated Steam\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent (Suffix \u003cstrong\u003eTV\u003c\/strong\u003e) A Thermic Vent is recommended when using a Bucket Trap on any type of process application or where the removal of air from the system is critical.\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent \u0026amp; Check Valve (Suffix \u003cstrong\u003eTCV\u003c\/strong\u003e) For combination of Check Valve \u0026amp; Thermic Vent\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e\u003cp\u003eTrap must be installed in upright position to function properly. All working components can be replaced with the trap body remaining in-line. With superheated steam, a check valve should be installed at inlet or trap may lose prime. A replacement kit containing the lever and seat assembly is a more economical option than replacing the entire steam trap. Also available are replacement screens, gaskets and buckets. When ordering replacement lever and seat assemblies, specify model and operating pressure. See Replacement Parts and Kits Section for exact cross-reference to Armstrong PCA (Pressure Change Assembly) kits.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eModel\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1031\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSizes\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e3\/4\"\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eConnections\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eNPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Material\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eCast Iron\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eInternal check valve, Thermic vent\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMO Max. Operating Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e20 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMO Max. Operating Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMA Max. Allowable Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 PSIG up to 450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMA Max. Allowable Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F @ 250 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eIB1031-13-N-020-TCV\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap-Spec-Sheet.pdf?v=1786494449\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"Watson McDaniel","offers":[{"title":"Default Title","offer_id":44165900042318,"sku":"IB1031-13-N-020-TCV","price":631.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap__71876.1784299744.1280.1280.jpg?v=1786663443"},{"product_id":"watson-mcdaniel-ib1031-series-inverted-bucket-steam-trap-cast-iron-body-80-psig-in-line-repairability-3-4-npt","title":"Watson McDaniel IB1031 Series Inverted Bucket Steam Trap, Cast Iron Body, 80 PSIG, In-line Repairability, 3\/4\" NPT","description":"\u003ch2\u003eWatson McDaniel IB1031 Series Inverted Bucket Steam Trap - 3\/4\" NPT (80 PSIG)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWaterhammer Resistant\u003c\/li\u003e\n\u003cli\u003eSuitable for superheated steam (use internal check valve option to eliminate loss of prime)\u003c\/li\u003e\n\u003cli\u003eIn-line repairability is simplified by having all internals attached to the cover\u003c\/li\u003e\n\u003cli\u003eValve \u0026amp; seat are located at the top of the trap body making them less prone to clogging from debris and pipe scale\u003c\/li\u003e\n\u003cli\u003eAll stainless steel internals with hardened valve \u0026amp; seat\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eIB1031 Series\u003c\/h2\u003e\u003cp\u003eThe IB1031 series is the smallest of the IB series. It has a max operating pressure (PMO) of up to 150 PSIG and at max differential pressure, it can handle up to 690 lbs\/hr of condensate.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDRIP, TRACING, PROCESS:\u003c\/strong\u003e IB Series inverted bucket steam traps are used in drip applications to remove condensate from steam mains and steam supply lines. For drip applications, the smaller sized units have adequate capacity. The discharge orifice of the inverted bucket trap is mounted at the top of the trap body, which makes them less susceptible to failure from dirt and debris when compared to other trap types. Since Inverted Bucket traps have poor air-handling capability, they are normally not recommended for most process applications. However, they can be used on certain process applications such as unit heaters and laundry equipment,where discharging air during system start-up is not a critical factor. F\u0026amp;T traps are the preferred choice for systems where air must be quickly discharged.\u003c\/p\u003e\u003ch2\u003eHow It Works\u003c\/h2\u003e\u003cp\u003eWhen the trap is filled with condensate, the inverted bucket inside the steam trap loses its buoyancy and rests on the bottom of the trap. This pulls the disc off the seat allowing condensate to be discharged through the seat orifice located at the top of the trap. When steam enters, it fills the inverted bucket causing the bucket to float to the surface which closes the discharge valve, containing the steam in the system. Eventually, the steam is bled off through a small hole in the top of the bucket causing it to sink, which repeats the cycle.\u003c\/p\u003e\u003ch2\u003eSelection \/ Sizing \/ Capacities\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eSelect A Model With A Higher Maximum Operating Pressure (PMO)\u003c\/strong\u003e that Meet or Exceed the Maximum Steam Pressure or The Trap May Not Open. for Example, the Ib-1031-13-N-150 Has a Max Pmo of 150 Psi, Will Handle Capacity up To 570 Lbs\/hr at Maximum. Choose a Model that Will Handle the Capacity Requirement Based on The Differential Pressure Across the Trap. Reference Capacity Charts.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eExample:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eApplication: 100 Lbs\/hr at 75 Psig Working Pressure and 2 Psi Differential Pressure\u003c\/li\u003e\n\u003cli\u003eSize\/model: Ib1031, 80 Psig, Specify Pipe Size (1\/2\", 3\/4\"), or Ib1041, 80 Psig, Specify Pipe Size (3\/4\", 1\").\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eOptions\u003c\/h2\u003e\u003cp\u003eStrainer and Blowdown valve connection available on 1041, 1042, 1044 \u0026amp; 1038S. We also have 3 accessories for this trap are Thermic vent to improve air handling capability. Internal check valve for superheated or condensate backflow applications.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow to Order Accessories:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCheck Valve (Suffix \u003cstrong\u003eCV\u003c\/strong\u003e) Built-in Inlet Check Valve is recommended when used on Superheated Steam\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent (Suffix \u003cstrong\u003eTV\u003c\/strong\u003e) A Thermic Vent is recommended when using a Bucket Trap on any type of process application or where the removal of air from the system is critical.\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent \u0026amp; Check Valve (Suffix \u003cstrong\u003eTCV\u003c\/strong\u003e) For combination of Check Valve \u0026amp; Thermic Vent\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e\u003cp\u003eTrap must be installed in upright position to function properly. All working components can be replaced with the trap body remaining in-line. With superheated steam, a check valve should be installed at inlet or trap may lose prime. A replacement kit containing the lever and seat assembly is a more economical option than replacing the entire steam trap. Also available are replacement screens, gaskets and buckets. When ordering replacement lever and seat assemblies, specify model and operating pressure. See Replacement Parts and Kits Section for exact cross-reference to Armstrong PCA (Pressure Change Assembly) kits.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eModel\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1031\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSizes\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e3\/4\"\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eConnections\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eNPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Material\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eCast Iron\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eInternal check valve, Thermic vent\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMO Max. Operating Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e80 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMO Max. Operating Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMA Max. Allowable Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 PSIG up to 450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMA Max. Allowable Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F @ 250 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap-Spec-Sheet.pdf?v=1786494449\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"Watson McDaniel","offers":[{"title":"Default Title","offer_id":44165900107854,"sku":"WM-IB1031-34-080","price":217.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap__37763.1784299744.1280.1280.jpg?v=1786663446"},{"product_id":"watson-mcdaniel-ib1031-13-n-080-inverted-bucket-steam-trap-cast-iron-body-80-psig-in-line-repairability-npt","title":"Watson McDaniel IB1031-13-N-080 Inverted Bucket Steam Trap, Cast Iron Body, 80 PSIG, In-line Repairability, NPT","description":"\u003ch2\u003eWatson McDaniel IB1031-13-N-080 Inverted Bucket Steam Trap - 3\/4\" NPT (80 PSIG)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWaterhammer Resistant\u003c\/li\u003e\n\u003cli\u003eSuitable for superheated steam (use internal check valve option to eliminate loss of prime)\u003c\/li\u003e\n\u003cli\u003eIn-line repairability is simplified by having all internals attached to the cover\u003c\/li\u003e\n\u003cli\u003eValve \u0026amp; seat are located at the top of the trap body making them less prone to clogging from debris and pipe scale\u003c\/li\u003e\n\u003cli\u003eAll stainless steel internals with hardened valve \u0026amp; seat\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eIB1031 Series\u003c\/h2\u003e\u003cp\u003eThe IB1031 series is the smallest of the IB series. It has a max operating pressure (PMO) of up to 150 PSIG and at max differential pressure, it can handle up to 690 lbs\/hr of condensate.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDRIP, TRACING, PROCESS:\u003c\/strong\u003e IB Series inverted bucket steam traps are used in drip applications to remove condensate from steam mains and steam supply lines. For drip applications, the smaller sized units have adequate capacity. The discharge orifice of the inverted bucket trap is mounted at the top of the trap body, which makes them less susceptible to failure from dirt and debris when compared to other trap types. Since Inverted Bucket traps have poor air-handling capability, they are normally not recommended for most process applications. However, they can be used on certain process applications such as unit heaters and laundry equipment,where discharging air during system start-up is not a critical factor. F\u0026amp;T traps are the preferred choice for systems where air must be quickly discharged.\u003c\/p\u003e\u003ch2\u003eHow It Works\u003c\/h2\u003e\u003cp\u003eWhen the trap is filled with condensate, the inverted bucket inside the steam trap loses its buoyancy and rests on the bottom of the trap. This pulls the disc off the seat allowing condensate to be discharged through the seat orifice located at the top of the trap. When steam enters, it fills the inverted bucket causing the bucket to float to the surface which closes the discharge valve, containing the steam in the system. Eventually, the steam is bled off through a small hole in the top of the bucket causing it to sink, which repeats the cycle.\u003c\/p\u003e\u003ch2\u003eSelection \/ Sizing \/ Capacities\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eSelect A Model With A Higher Maximum Operating Pressure (PMO)\u003c\/strong\u003e that Meet or Exceed the Maximum Steam Pressure or The Trap May Not Open. for Example, the Ib-1031-13-N-150 Has a Max Pmo of 150 Psi, Will Handle Capacity up To 570 Lbs\/hr at Maximum. Choose a Model that Will Handle the Capacity Requirement Based on The Differential Pressure Across the Trap. Reference Capacity Charts.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eExample:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eApplication: 100 Lbs\/hr at 75 Psig Working Pressure and 2 Psi Differential Pressure\u003c\/li\u003e\n\u003cli\u003eSize\/model: Ib1031, 80 Psig, Specify Pipe Size (1\/2\", 3\/4\"), or Ib1041, 80 Psig, Specify Pipe Size (3\/4\", 1\").\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eOptions\u003c\/h2\u003e\u003cp\u003eStrainer and Blowdown valve connection available on 1041, 1042, 1044 \u0026amp; 1038S. We also have 3 accessories for this trap are Thermic vent to improve air handling capability. Internal check valve for superheated or condensate backflow applications.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow to Order Accessories:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCheck Valve (Suffix \u003cstrong\u003eCV\u003c\/strong\u003e) Built-in Inlet Check Valve is recommended when used on Superheated Steam\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent (Suffix \u003cstrong\u003eTV\u003c\/strong\u003e) A Thermic Vent is recommended when using a Bucket Trap on any type of process application or where the removal of air from the system is critical.\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent \u0026amp; Check Valve (Suffix \u003cstrong\u003eTCV\u003c\/strong\u003e) For combination of Check Valve \u0026amp; Thermic Vent\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e\u003cp\u003eTrap must be installed in upright position to function properly. All working components can be replaced with the trap body remaining in-line. With superheated steam, a check valve should be installed at inlet or trap may lose prime. A replacement kit containing the lever and seat assembly is a more economical option than replacing the entire steam trap. Also available are replacement screens, gaskets and buckets. When ordering replacement lever and seat assemblies, specify model and operating pressure. See Replacement Parts and Kits Section for exact cross-reference to Armstrong PCA (Pressure Change Assembly) kits.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eModel\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1031\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSizes\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e3\/4\"\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eConnections\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eNPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Material\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eCast Iron\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eInternal check valve, Thermic vent\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMO Max. Operating Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e80 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMO Max. Operating Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMA Max. Allowable Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 PSIG up to 450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMA Max. Allowable Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F @ 250 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eIB1031-13-N-080\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap-Spec-Sheet.pdf?v=1786494449\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"Watson McDaniel","offers":[{"title":"Default Title","offer_id":44165900173390,"sku":"IB1031-13-N-080","price":217.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap__72486.1784299744.1280.1280.jpg?v=1786663448"},{"product_id":"watson-mcdaniel-ib1031-13-n-080-cv-inverted-bucket-steam-trap-cast-iron-body-80-psig-in-line-repairability-npt","title":"Watson McDaniel IB1031-13-N-080-CV Inverted Bucket Steam Trap, Cast Iron Body, 80 PSIG, In-line Repairability, NPT","description":"\u003ch2\u003eWatson McDaniel IB1031-13-N-080-CV Inverted Bucket Steam Trap - 3\/4\" NPT (80 PSIG)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWaterhammer Resistant\u003c\/li\u003e\n\u003cli\u003eSuitable for superheated steam (use internal check valve option to eliminate loss of prime)\u003c\/li\u003e\n\u003cli\u003eIn-line repairability is simplified by having all internals attached to the cover\u003c\/li\u003e\n\u003cli\u003eValve \u0026amp; seat are located at the top of the trap body making them less prone to clogging from debris and pipe scale\u003c\/li\u003e\n\u003cli\u003eAll stainless steel internals with hardened valve \u0026amp; seat\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eIB1031 Series\u003c\/h2\u003e\u003cp\u003eThe IB1031 series is the smallest of the IB series. It has a max operating pressure (PMO) of up to 150 PSIG and at max differential pressure, it can handle up to 690 lbs\/hr of condensate.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDRIP, TRACING, PROCESS:\u003c\/strong\u003e IB Series inverted bucket steam traps are used in drip applications to remove condensate from steam mains and steam supply lines. For drip applications, the smaller sized units have adequate capacity. The discharge orifice of the inverted bucket trap is mounted at the top of the trap body, which makes them less susceptible to failure from dirt and debris when compared to other trap types. Since Inverted Bucket traps have poor air-handling capability, they are normally not recommended for most process applications. However, they can be used on certain process applications such as unit heaters and laundry equipment,where discharging air during system start-up is not a critical factor. F\u0026amp;T traps are the preferred choice for systems where air must be quickly discharged.\u003c\/p\u003e\u003ch2\u003eHow It Works\u003c\/h2\u003e\u003cp\u003eWhen the trap is filled with condensate, the inverted bucket inside the steam trap loses its buoyancy and rests on the bottom of the trap. This pulls the disc off the seat allowing condensate to be discharged through the seat orifice located at the top of the trap. When steam enters, it fills the inverted bucket causing the bucket to float to the surface which closes the discharge valve, containing the steam in the system. Eventually, the steam is bled off through a small hole in the top of the bucket causing it to sink, which repeats the cycle.\u003c\/p\u003e\u003ch2\u003eSelection \/ Sizing \/ Capacities\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eSelect A Model With A Higher Maximum Operating Pressure (PMO)\u003c\/strong\u003e that Meet or Exceed the Maximum Steam Pressure or The Trap May Not Open. for Example, the Ib-1031-13-N-150 Has a Max Pmo of 150 Psi, Will Handle Capacity up To 570 Lbs\/hr at Maximum. Choose a Model that Will Handle the Capacity Requirement Based on The Differential Pressure Across the Trap. Reference Capacity Charts.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eExample:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eApplication: 100 Lbs\/hr at 75 Psig Working Pressure and 2 Psi Differential Pressure\u003c\/li\u003e\n\u003cli\u003eSize\/model: Ib1031, 80 Psig, Specify Pipe Size (1\/2\", 3\/4\"), or Ib1041, 80 Psig, Specify Pipe Size (3\/4\", 1\").\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eOptions\u003c\/h2\u003e\u003cp\u003eStrainer and Blowdown valve connection available on 1041, 1042, 1044 \u0026amp; 1038S. We also have 3 accessories for this trap are Thermic vent to improve air handling capability. Internal check valve for superheated or condensate backflow applications.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow to Order Accessories:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCheck Valve (Suffix \u003cstrong\u003eCV\u003c\/strong\u003e) Built-in Inlet Check Valve is recommended when used on Superheated Steam\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent (Suffix \u003cstrong\u003eTV\u003c\/strong\u003e) A Thermic Vent is recommended when using a Bucket Trap on any type of process application or where the removal of air from the system is critical.\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent \u0026amp; Check Valve (Suffix \u003cstrong\u003eTCV\u003c\/strong\u003e) For combination of Check Valve \u0026amp; Thermic Vent\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e\u003cp\u003eTrap must be installed in upright position to function properly. All working components can be replaced with the trap body remaining in-line. With superheated steam, a check valve should be installed at inlet or trap may lose prime. A replacement kit containing the lever and seat assembly is a more economical option than replacing the entire steam trap. Also available are replacement screens, gaskets and buckets. When ordering replacement lever and seat assemblies, specify model and operating pressure. See Replacement Parts and Kits Section for exact cross-reference to Armstrong PCA (Pressure Change Assembly) kits.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eModel\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1031\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSizes\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e3\/4\"\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eConnections\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eNPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Material\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eCast Iron\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eInternal check valve, Thermic vent\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMO Max. Operating Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e80 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMO Max. Operating Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMA Max. Allowable Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 PSIG up to 450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMA Max. Allowable Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F @ 250 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eIB1031-13-N-080-CV\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap-Spec-Sheet.pdf?v=1786494449\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"Watson McDaniel","offers":[{"title":"Default Title","offer_id":44165900238926,"sku":"IB1031-13-N-080-CV","price":364.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap__77352.1784299744.1280.1280.jpg?v=1786663451"},{"product_id":"watson-mcdaniel-ib1031-13-n-080-tv-inverted-bucket-steam-trap-cast-iron-body-80-psig-in-line-repairability-npt","title":"Watson McDaniel IB1031-13-N-080-TV Inverted Bucket Steam Trap, Cast Iron Body, 80 PSIG, In-line Repairability, NPT","description":"\u003ch2\u003eWatson McDaniel IB1031-13-N-080-TV Inverted Bucket Steam Trap - 3\/4\" NPT (80 PSIG)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWaterhammer Resistant\u003c\/li\u003e\n\u003cli\u003eSuitable for superheated steam (use internal check valve option to eliminate loss of prime)\u003c\/li\u003e\n\u003cli\u003eIn-line repairability is simplified by having all internals attached to the cover\u003c\/li\u003e\n\u003cli\u003eValve \u0026amp; seat are located at the top of the trap body making them less prone to clogging from debris and pipe scale\u003c\/li\u003e\n\u003cli\u003eAll stainless steel internals with hardened valve \u0026amp; seat\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eIB1031 Series\u003c\/h2\u003e\u003cp\u003eThe IB1031 series is the smallest of the IB series. It has a max operating pressure (PMO) of up to 150 PSIG and at max differential pressure, it can handle up to 690 lbs\/hr of condensate.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDRIP, TRACING, PROCESS:\u003c\/strong\u003e IB Series inverted bucket steam traps are used in drip applications to remove condensate from steam mains and steam supply lines. For drip applications, the smaller sized units have adequate capacity. The discharge orifice of the inverted bucket trap is mounted at the top of the trap body, which makes them less susceptible to failure from dirt and debris when compared to other trap types. Since Inverted Bucket traps have poor air-handling capability, they are normally not recommended for most process applications. However, they can be used on certain process applications such as unit heaters and laundry equipment,where discharging air during system start-up is not a critical factor. F\u0026amp;T traps are the preferred choice for systems where air must be quickly discharged.\u003c\/p\u003e\u003ch2\u003eHow It Works\u003c\/h2\u003e\u003cp\u003eWhen the trap is filled with condensate, the inverted bucket inside the steam trap loses its buoyancy and rests on the bottom of the trap. This pulls the disc off the seat allowing condensate to be discharged through the seat orifice located at the top of the trap. When steam enters, it fills the inverted bucket causing the bucket to float to the surface which closes the discharge valve, containing the steam in the system. Eventually, the steam is bled off through a small hole in the top of the bucket causing it to sink, which repeats the cycle.\u003c\/p\u003e\u003ch2\u003eSelection \/ Sizing \/ Capacities\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eSelect A Model With A Higher Maximum Operating Pressure (PMO)\u003c\/strong\u003e that Meet or Exceed the Maximum Steam Pressure or The Trap May Not Open. for Example, the Ib-1031-13-N-150 Has a Max Pmo of 150 Psi, Will Handle Capacity up To 570 Lbs\/hr at Maximum. Choose a Model that Will Handle the Capacity Requirement Based on The Differential Pressure Across the Trap. Reference Capacity Charts.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eExample:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eApplication: 100 Lbs\/hr at 75 Psig Working Pressure and 2 Psi Differential Pressure\u003c\/li\u003e\n\u003cli\u003eSize\/model: Ib1031, 80 Psig, Specify Pipe Size (1\/2\", 3\/4\"), or Ib1041, 80 Psig, Specify Pipe Size (3\/4\", 1\").\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eOptions\u003c\/h2\u003e\u003cp\u003eStrainer and Blowdown valve connection available on 1041, 1042, 1044 \u0026amp; 1038S. We also have 3 accessories for this trap are Thermic vent to improve air handling capability. Internal check valve for superheated or condensate backflow applications.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow to Order Accessories:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCheck Valve (Suffix \u003cstrong\u003eCV\u003c\/strong\u003e) Built-in Inlet Check Valve is recommended when used on Superheated Steam\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent (Suffix \u003cstrong\u003eTV\u003c\/strong\u003e) A Thermic Vent is recommended when using a Bucket Trap on any type of process application or where the removal of air from the system is critical.\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent \u0026amp; Check Valve (Suffix \u003cstrong\u003eTCV\u003c\/strong\u003e) For combination of Check Valve \u0026amp; Thermic Vent\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e\u003cp\u003eTrap must be installed in upright position to function properly. All working components can be replaced with the trap body remaining in-line. With superheated steam, a check valve should be installed at inlet or trap may lose prime. A replacement kit containing the lever and seat assembly is a more economical option than replacing the entire steam trap. Also available are replacement screens, gaskets and buckets. When ordering replacement lever and seat assemblies, specify model and operating pressure. See Replacement Parts and Kits Section for exact cross-reference to Armstrong PCA (Pressure Change Assembly) kits.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eModel\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1031\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSizes\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e3\/4\"\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eConnections\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eNPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Material\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eCast Iron\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eInternal check valve, Thermic vent\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMO Max. Operating Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e80 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMO Max. Operating Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMA Max. Allowable Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 PSIG up to 450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMA Max. Allowable Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F @ 250 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eIB1031-13-N-080-TV\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap-Spec-Sheet.pdf?v=1786494449\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"Watson McDaniel","offers":[{"title":"Default Title","offer_id":44165900304462,"sku":"IB1031-13-N-080-TV","price":435.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap__13466.1784299744.1280.1280.jpg?v=1786663453"},{"product_id":"watson-mcdaniel-ib1031-13-n-080-tcv-inverted-bucket-steam-trap-cast-iron-body-80-psig-in-line-repairability-npt","title":"Watson McDaniel IB1031-13-N-080-TCV Inverted Bucket Steam Trap, Cast Iron Body, 80 PSIG, In-line Repairability, NPT","description":"\u003ch2\u003eWatson McDaniel IB1031-13-N-080-TCV Inverted Bucket Steam Trap - 3\/4\" NPT (80 PSIG)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWaterhammer Resistant\u003c\/li\u003e\n\u003cli\u003eSuitable for superheated steam (use internal check valve option to eliminate loss of prime)\u003c\/li\u003e\n\u003cli\u003eIn-line repairability is simplified by having all internals attached to the cover\u003c\/li\u003e\n\u003cli\u003eValve \u0026amp; seat are located at the top of the trap body making them less prone to clogging from debris and pipe scale\u003c\/li\u003e\n\u003cli\u003eAll stainless steel internals with hardened valve \u0026amp; seat\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eIB1031 Series\u003c\/h2\u003e\u003cp\u003eThe IB1031 series is the smallest of the IB series. It has a max operating pressure (PMO) of up to 150 PSIG and at max differential pressure, it can handle up to 690 lbs\/hr of condensate.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDRIP, TRACING, PROCESS:\u003c\/strong\u003e IB Series inverted bucket steam traps are used in drip applications to remove condensate from steam mains and steam supply lines. For drip applications, the smaller sized units have adequate capacity. The discharge orifice of the inverted bucket trap is mounted at the top of the trap body, which makes them less susceptible to failure from dirt and debris when compared to other trap types. Since Inverted Bucket traps have poor air-handling capability, they are normally not recommended for most process applications. However, they can be used on certain process applications such as unit heaters and laundry equipment,where discharging air during system start-up is not a critical factor. F\u0026amp;T traps are the preferred choice for systems where air must be quickly discharged.\u003c\/p\u003e\u003ch2\u003eHow It Works\u003c\/h2\u003e\u003cp\u003eWhen the trap is filled with condensate, the inverted bucket inside the steam trap loses its buoyancy and rests on the bottom of the trap. This pulls the disc off the seat allowing condensate to be discharged through the seat orifice located at the top of the trap. When steam enters, it fills the inverted bucket causing the bucket to float to the surface which closes the discharge valve, containing the steam in the system. Eventually, the steam is bled off through a small hole in the top of the bucket causing it to sink, which repeats the cycle.\u003c\/p\u003e\u003ch2\u003eSelection \/ Sizing \/ Capacities\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eSelect A Model With A Higher Maximum Operating Pressure (PMO)\u003c\/strong\u003e that Meet or Exceed the Maximum Steam Pressure or The Trap May Not Open. for Example, the Ib-1031-13-N-150 Has a Max Pmo of 150 Psi, Will Handle Capacity up To 570 Lbs\/hr at Maximum. Choose a Model that Will Handle the Capacity Requirement Based on The Differential Pressure Across the Trap. Reference Capacity Charts.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eExample:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eApplication: 100 Lbs\/hr at 75 Psig Working Pressure and 2 Psi Differential Pressure\u003c\/li\u003e\n\u003cli\u003eSize\/model: Ib1031, 80 Psig, Specify Pipe Size (1\/2\", 3\/4\"), or Ib1041, 80 Psig, Specify Pipe Size (3\/4\", 1\").\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eOptions\u003c\/h2\u003e\u003cp\u003eStrainer and Blowdown valve connection available on 1041, 1042, 1044 \u0026amp; 1038S. We also have 3 accessories for this trap are Thermic vent to improve air handling capability. Internal check valve for superheated or condensate backflow applications.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow to Order Accessories:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCheck Valve (Suffix \u003cstrong\u003eCV\u003c\/strong\u003e) Built-in Inlet Check Valve is recommended when used on Superheated Steam\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent (Suffix \u003cstrong\u003eTV\u003c\/strong\u003e) A Thermic Vent is recommended when using a Bucket Trap on any type of process application or where the removal of air from the system is critical.\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent \u0026amp; Check Valve (Suffix \u003cstrong\u003eTCV\u003c\/strong\u003e) For combination of Check Valve \u0026amp; Thermic Vent\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e\u003cp\u003eTrap must be installed in upright position to function properly. All working components can be replaced with the trap body remaining in-line. With superheated steam, a check valve should be installed at inlet or trap may lose prime. A replacement kit containing the lever and seat assembly is a more economical option than replacing the entire steam trap. Also available are replacement screens, gaskets and buckets. When ordering replacement lever and seat assemblies, specify model and operating pressure. See Replacement Parts and Kits Section for exact cross-reference to Armstrong PCA (Pressure Change Assembly) kits.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eModel\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1031\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSizes\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e3\/4\"\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eConnections\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eNPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Material\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eCast Iron\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eInternal check valve, Thermic vent\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMO Max. Operating Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e80 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMO Max. Operating Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMA Max. Allowable Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 PSIG up to 450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMA Max. Allowable Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F @ 250 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eIB1031-13-N-080-TCV\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap-Spec-Sheet.pdf?v=1786494449\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"Watson McDaniel","offers":[{"title":"Default Title","offer_id":44165900369998,"sku":"IB1031-13-N-080-TCV","price":631.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap__12431.1784299744.1280.1280.jpg?v=1786663456"},{"product_id":"watson-mcdaniel-ib1032-series-inverted-bucket-steam-trap-cast-iron-body-15-psig-in-line-repairability-1-2-npt","title":"Watson McDaniel IB1032 Series Inverted Bucket Steam Trap, Cast Iron Body, 15 PSIG, In-line Repairability, 1\/2\" NPT","description":"\u003ch2\u003eWatson McDaniel IB1032 Series Inverted Bucket Steam Trap - 1\/2\" NPT (15 PSIG)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWaterhammer resistant\u003c\/li\u003e\n\u003cli\u003eSuitable for superheated steam (Use internal check valve option to eliminate loss of prime)\u003c\/li\u003e\n\u003cli\u003eIn-line repairability is simplified by having all internals attached to the cover\u003c\/li\u003e\n\u003cli\u003eValve \u0026amp; seat are located at the top of the trap body making them less prone to clogging from debris and pipe scale\u003c\/li\u003e\n\u003cli\u003eAll stainless steel internals with hardened valve \u0026amp; seat\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eIB1032 Series\u003c\/h2\u003e\u003cp\u003eThe IB1032 series has a larger capacity than the IB1031. It has a max operating pressure (PMO) of 250 PSIG and at max differential pressure, it can handle up to 1,060 lbs\/hr of condensate.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDRIP, TRACING, PROCESS:\u003c\/strong\u003e IB Series inverted bucket steam traps are used in drip applications to remove condensate from steam mains and steam supply lines. For drip applications, the smaller sized units have adequate capacity. The discharge orifice of the inverted bucket trap is mounted at the top of the trap body, which makes them less susceptible to failure from dirt and debris when compared to other trap types. Since Inverted Bucket traps have poor air-handling capability, they are normally not recommended for most process applications. However, they can be used on certain process applications such as unit heaters and laundry equipment,where discharging air during system start-up is not a critical factor. F\u0026amp;T traps are the preferred choice for systems where air must be quickly discharged.\u003c\/p\u003e\u003ch2\u003eHow It Works\u003c\/h2\u003e\u003cp\u003eWhen the trap is filled with condensate, the inverted bucket inside the steam trap loses its buoyancy and rests on the bottom of the trap. This pulls the disc off the seat allowing condensate to be discharged through the seat orifice located at the top of the trap. When steam enters, it fills the inverted bucket causing the bucket to float to the surface which closes the discharge valve, containing the steam in the system. Eventually, the steam is bled off through a small hole in the top of the bucket causing it to sink, which repeats the cycle.\u003c\/p\u003e\u003ch2\u003eSelection \/ Sizing \/ Capacities\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eSelect a model with a higher maximum operating pressure (PMO)\u003c\/strong\u003e that meet or exceed the maximum steam pressure or the trap may not open. For example, the IB-1031-13-N-150 has a Max PMO of 150 PSI, will handle capacity up to 570 lbs\/hr at Maximum. Choose a model that will handle the capacity requirement based on the differential pressure across the trap. Reference capacity charts.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eExample:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eApplication: 100 lbs\/hr at 75 PSIG working pressure and 2 PSI differential pressure\u003c\/li\u003e\n\u003cli\u003eSize\/Model: IB1031, 80 PSIG, Specify pipe size (1\/2\", 3\/4\"), or IB1041, 80 PSIG, Specify pipe size (3\/4\", 1\").\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e\u003cp\u003eTrap must be installed in upright position to function properly. All working components can be replaced with the trap body remaining in-line. With superheated steam, a check valve should be installed at inlet or trap may lose prime. A replacement kit containing the lever and seat assembly is a more economical option than replacing the entire steam trap. Also available are replacement screens, gaskets and buckets. When ordering replacement lever and seat assemblies, specify model and operating pressure. See Replacement Parts and Kits Section for exact cross-reference to Armstrong PCA (Pressure Change Assembly) kits.\u003c\/p\u003e\u003ch2\u003eOptions\u003c\/h2\u003e\u003cp\u003eStrainer and Blowdown valve connection available on 1041, 1042, 1044 \u0026amp; 1038S. We also have 3 accessories for this trap are Thermic vent to improve air handling capability. Internal check valve for superheated or condensate backflow applications.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow to Order Accessories:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCheck Valve (Suffix \u003cstrong\u003eCV\u003c\/strong\u003e) Built-in Inlet Check Valve is recommended when used on Superheated Steam\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent (Suffix \u003cstrong\u003eTV\u003c\/strong\u003e) A Thermic Vent is recommended when using a Bucket Trap on any type of process application or where the removal of air from the system is critical.\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent \u0026amp; Check Valve (Suffix \u003cstrong\u003eTCV\u003c\/strong\u003e) For combination of Check Valve \u0026amp; Thermic Vent\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eModel\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1032\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSizes\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\"\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eConnections\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eNPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Material\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eCast Iron\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eInternal check valve, Thermic vent\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMO Max. Operating Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e15 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMO Max. Operating Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMA Max. Allowable Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 PSIG up to 450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMA Max. Allowable Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F @ 250 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap-Spec-Sheet.pdf?v=1786494449\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"Watson McDaniel","offers":[{"title":"Default Title","offer_id":44165900435534,"sku":"WM-IB1032-12-N-015","price":301.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1032-Inverted-Bucket-Steam-Trap__43102.1784299721.1280.1280.jpg?v=1786663458"},{"product_id":"watson-mcdaniel-ib1032-12-n-015-inverted-bucket-steam-trap-cast-iron-body-15-psig-in-line-repairability-npt","title":"Watson McDaniel IB1032-12-N-015 Inverted Bucket Steam Trap, Cast Iron Body, 15 PSIG, In-line Repairability, NPT","description":"\u003ch2\u003eWatson McDaniel IB1032-12-N-015 Inverted Bucket Steam Trap - 1\/2\" NPT (15 PSIG)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWaterhammer resistant\u003c\/li\u003e\n\u003cli\u003eSuitable for superheated steam (Use internal check valve option to eliminate loss of prime)\u003c\/li\u003e\n\u003cli\u003eIn-line repairability is simplified by having all internals attached to the cover\u003c\/li\u003e\n\u003cli\u003eValve \u0026amp; seat are located at the top of the trap body making them less prone to clogging from debris and pipe scale\u003c\/li\u003e\n\u003cli\u003eAll stainless steel internals with hardened valve \u0026amp; seat\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eIB1032 Series\u003c\/h2\u003e\u003cp\u003eThe IB1032 series has a larger capacity than the IB1031. It has a max operating pressure (PMO) of 250 PSIG and at max differential pressure, it can handle up to 1,060 lbs\/hr of condensate.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDRIP, TRACING, PROCESS:\u003c\/strong\u003e IB Series inverted bucket steam traps are used in drip applications to remove condensate from steam mains and steam supply lines. For drip applications, the smaller sized units have adequate capacity. The discharge orifice of the inverted bucket trap is mounted at the top of the trap body, which makes them less susceptible to failure from dirt and debris when compared to other trap types. Since Inverted Bucket traps have poor air-handling capability, they are normally not recommended for most process applications. However, they can be used on certain process applications such as unit heaters and laundry equipment,where discharging air during system start-up is not a critical factor. F\u0026amp;T traps are the preferred choice for systems where air must be quickly discharged.\u003c\/p\u003e\u003ch2\u003eHow It Works\u003c\/h2\u003e\u003cp\u003eWhen the trap is filled with condensate, the inverted bucket inside the steam trap loses its buoyancy and rests on the bottom of the trap. This pulls the disc off the seat allowing condensate to be discharged through the seat orifice located at the top of the trap. When steam enters, it fills the inverted bucket causing the bucket to float to the surface which closes the discharge valve, containing the steam in the system. Eventually, the steam is bled off through a small hole in the top of the bucket causing it to sink, which repeats the cycle.\u003c\/p\u003e\u003ch2\u003eSelection \/ Sizing \/ Capacities\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eSelect a model with a higher maximum operating pressure (PMO)\u003c\/strong\u003e that meet or exceed the maximum steam pressure or the trap may not open. For example, the IB-1031-13-N-150 has a Max PMO of 150 PSI, will handle capacity up to 570 lbs\/hr at Maximum. Choose a model that will handle the capacity requirement based on the differential pressure across the trap. Reference capacity charts.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eExample:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eApplication: 100 lbs\/hr at 75 PSIG working pressure and 2 PSI differential pressure\u003c\/li\u003e\n\u003cli\u003eSize\/Model: IB1031, 80 PSIG, Specify pipe size (1\/2\", 3\/4\"), or IB1041, 80 PSIG, Specify pipe size (3\/4\", 1\").\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e\u003cp\u003eTrap must be installed in upright position to function properly. All working components can be replaced with the trap body remaining in-line. With superheated steam, a check valve should be installed at inlet or trap may lose prime. A replacement kit containing the lever and seat assembly is a more economical option than replacing the entire steam trap. Also available are replacement screens, gaskets and buckets. When ordering replacement lever and seat assemblies, specify model and operating pressure. See Replacement Parts and Kits Section for exact cross-reference to Armstrong PCA (Pressure Change Assembly) kits.\u003c\/p\u003e\u003ch2\u003eOptions\u003c\/h2\u003e\u003cp\u003eStrainer and Blowdown valve connection available on 1041, 1042, 1044 \u0026amp; 1038S. We also have 3 accessories for this trap are Thermic vent to improve air handling capability. Internal check valve for superheated or condensate backflow applications.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow to Order Accessories:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCheck Valve (Suffix \u003cstrong\u003eCV\u003c\/strong\u003e) Built-in Inlet Check Valve is recommended when used on Superheated Steam\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent (Suffix \u003cstrong\u003eTV\u003c\/strong\u003e) A Thermic Vent is recommended when using a Bucket Trap on any type of process application or where the removal of air from the system is critical.\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent \u0026amp; Check Valve (Suffix \u003cstrong\u003eTCV\u003c\/strong\u003e) For combination of Check Valve \u0026amp; Thermic Vent\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eModel\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1032\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSizes\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\"\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eConnections\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eNPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Material\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eCast Iron\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eInternal check valve, Thermic vent\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMO Max. Operating Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e15 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMO Max. Operating Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMA Max. Allowable Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 PSIG up to 450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMA Max. Allowable Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F @ 250 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eIB1032-12-N-015\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap-Spec-Sheet.pdf?v=1786494449\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"Watson McDaniel","offers":[{"title":"Default Title","offer_id":44165900501070,"sku":"IB1032-12-N-015","price":301.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1032-Inverted-Bucket-Steam-Trap__82006.1784299721.1280.1280.jpg?v=1786663461"},{"product_id":"watson-mcdaniel-ib1032-12-n-015-cv-inverted-bucket-steam-trap-cast-iron-body-15-psig-in-line-repairability-npt","title":"Watson McDaniel IB1032-12-N-015-CV Inverted Bucket Steam Trap, Cast Iron Body, 15 PSIG, In-line Repairability, NPT","description":"\u003ch2\u003eWatson McDaniel IB1032-12-N-015-CV Inverted Bucket Steam Trap - 1\/2\" NPT (15 PSIG)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWaterhammer resistant\u003c\/li\u003e\n\u003cli\u003eSuitable for superheated steam (Use internal check valve option to eliminate loss of prime)\u003c\/li\u003e\n\u003cli\u003eIn-line repairability is simplified by having all internals attached to the cover\u003c\/li\u003e\n\u003cli\u003eValve \u0026amp; seat are located at the top of the trap body making them less prone to clogging from debris and pipe scale\u003c\/li\u003e\n\u003cli\u003eAll stainless steel internals with hardened valve \u0026amp; seat\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eIB1032 Series\u003c\/h2\u003e\u003cp\u003eThe IB1032 series has a larger capacity than the IB1031. It has a max operating pressure (PMO) of 250 PSIG and at max differential pressure, it can handle up to 1,060 lbs\/hr of condensate.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDRIP, TRACING, PROCESS:\u003c\/strong\u003e IB Series inverted bucket steam traps are used in drip applications to remove condensate from steam mains and steam supply lines. For drip applications, the smaller sized units have adequate capacity. The discharge orifice of the inverted bucket trap is mounted at the top of the trap body, which makes them less susceptible to failure from dirt and debris when compared to other trap types. Since Inverted Bucket traps have poor air-handling capability, they are normally not recommended for most process applications. However, they can be used on certain process applications such as unit heaters and laundry equipment,where discharging air during system start-up is not a critical factor. F\u0026amp;T traps are the preferred choice for systems where air must be quickly discharged.\u003c\/p\u003e\u003ch2\u003eHow It Works\u003c\/h2\u003e\u003cp\u003eWhen the trap is filled with condensate, the inverted bucket inside the steam trap loses its buoyancy and rests on the bottom of the trap. This pulls the disc off the seat allowing condensate to be discharged through the seat orifice located at the top of the trap. When steam enters, it fills the inverted bucket causing the bucket to float to the surface which closes the discharge valve, containing the steam in the system. Eventually, the steam is bled off through a small hole in the top of the bucket causing it to sink, which repeats the cycle.\u003c\/p\u003e\u003ch2\u003eSelection \/ Sizing \/ Capacities\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eSelect a model with a higher maximum operating pressure (PMO)\u003c\/strong\u003e that meet or exceed the maximum steam pressure or the trap may not open. For example, the IB-1031-13-N-150 has a Max PMO of 150 PSI, will handle capacity up to 570 lbs\/hr at Maximum. Choose a model that will handle the capacity requirement based on the differential pressure across the trap. Reference capacity charts.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eExample:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eApplication: 100 lbs\/hr at 75 PSIG working pressure and 2 PSI differential pressure\u003c\/li\u003e\n\u003cli\u003eSize\/Model: IB1031, 80 PSIG, Specify pipe size (1\/2\", 3\/4\"), or IB1041, 80 PSIG, Specify pipe size (3\/4\", 1\").\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e\u003cp\u003eTrap must be installed in upright position to function properly. All working components can be replaced with the trap body remaining in-line. With superheated steam, a check valve should be installed at inlet or trap may lose prime. A replacement kit containing the lever and seat assembly is a more economical option than replacing the entire steam trap. Also available are replacement screens, gaskets and buckets. When ordering replacement lever and seat assemblies, specify model and operating pressure. See Replacement Parts and Kits Section for exact cross-reference to Armstrong PCA (Pressure Change Assembly) kits.\u003c\/p\u003e\u003ch2\u003eOptions\u003c\/h2\u003e\u003cp\u003eStrainer and Blowdown valve connection available on 1041, 1042, 1044 \u0026amp; 1038S. We also have 3 accessories for this trap are Thermic vent to improve air handling capability. Internal check valve for superheated or condensate backflow applications.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow to Order Accessories:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCheck Valve (Suffix \u003cstrong\u003eCV\u003c\/strong\u003e) Built-in Inlet Check Valve is recommended when used on Superheated Steam\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent (Suffix \u003cstrong\u003eTV\u003c\/strong\u003e) A Thermic Vent is recommended when using a Bucket Trap on any type of process application or where the removal of air from the system is critical.\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent \u0026amp; Check Valve (Suffix \u003cstrong\u003eTCV\u003c\/strong\u003e) For combination of Check Valve \u0026amp; Thermic Vent\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eModel\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1032\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSizes\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\"\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eConnections\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eNPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Material\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eCast Iron\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eInternal check valve, Thermic vent\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMO Max. Operating Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e15 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMO Max. Operating Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMA Max. Allowable Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 PSIG up to 450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMA Max. Allowable Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F @ 250 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eIB1032-12-N-015-CV\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap-Spec-Sheet.pdf?v=1786494449\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"Watson McDaniel","offers":[{"title":"Default Title","offer_id":44165900566606,"sku":"IB1032-12-N-015-CV","price":439.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1032-Inverted-Bucket-Steam-Trap__97755.1784299744.1280.1280.jpg?v=1786663463"},{"product_id":"watson-mcdaniel-ib1032-12-n-015-tv-inverted-bucket-steam-trap-cast-iron-body-15-psig-in-line-repairability-npt","title":"Watson McDaniel IB1032-12-N-015-TV Inverted Bucket Steam Trap, Cast Iron Body, 15 PSIG, In-line Repairability, NPT","description":"\u003ch2\u003eWatson McDaniel IB1032-12-N-015-TV Inverted Bucket Steam Trap - 1\/2\" NPT (15 PSIG)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWaterhammer resistant\u003c\/li\u003e\n\u003cli\u003eSuitable for superheated steam (Use internal check valve option to eliminate loss of prime)\u003c\/li\u003e\n\u003cli\u003eIn-line repairability is simplified by having all internals attached to the cover\u003c\/li\u003e\n\u003cli\u003eValve \u0026amp; seat are located at the top of the trap body making them less prone to clogging from debris and pipe scale\u003c\/li\u003e\n\u003cli\u003eAll stainless steel internals with hardened valve \u0026amp; seat\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eIB1032 Series\u003c\/h2\u003e\u003cp\u003eThe IB1032 series has a larger capacity than the IB1031. It has a max operating pressure (PMO) of 250 PSIG and at max differential pressure, it can handle up to 1,060 lbs\/hr of condensate.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDRIP, TRACING, PROCESS:\u003c\/strong\u003e IB Series inverted bucket steam traps are used in drip applications to remove condensate from steam mains and steam supply lines. For drip applications, the smaller sized units have adequate capacity. The discharge orifice of the inverted bucket trap is mounted at the top of the trap body, which makes them less susceptible to failure from dirt and debris when compared to other trap types. Since Inverted Bucket traps have poor air-handling capability, they are normally not recommended for most process applications. However, they can be used on certain process applications such as unit heaters and laundry equipment,where discharging air during system start-up is not a critical factor. F\u0026amp;T traps are the preferred choice for systems where air must be quickly discharged.\u003c\/p\u003e\u003ch2\u003eHow It Works\u003c\/h2\u003e\u003cp\u003eWhen the trap is filled with condensate, the inverted bucket inside the steam trap loses its buoyancy and rests on the bottom of the trap. This pulls the disc off the seat allowing condensate to be discharged through the seat orifice located at the top of the trap. When steam enters, it fills the inverted bucket causing the bucket to float to the surface which closes the discharge valve, containing the steam in the system. Eventually, the steam is bled off through a small hole in the top of the bucket causing it to sink, which repeats the cycle.\u003c\/p\u003e\u003ch2\u003eSelection \/ Sizing \/ Capacities\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eSelect a model with a higher maximum operating pressure (PMO)\u003c\/strong\u003e that meet or exceed the maximum steam pressure or the trap may not open. For example, the IB-1031-13-N-150 has a Max PMO of 150 PSI, will handle capacity up to 570 lbs\/hr at Maximum. Choose a model that will handle the capacity requirement based on the differential pressure across the trap. Reference capacity charts.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eExample:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eApplication: 100 lbs\/hr at 75 PSIG working pressure and 2 PSI differential pressure\u003c\/li\u003e\n\u003cli\u003eSize\/Model: IB1031, 80 PSIG, Specify pipe size (1\/2\", 3\/4\"), or IB1041, 80 PSIG, Specify pipe size (3\/4\", 1\").\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e\u003cp\u003eTrap must be installed in upright position to function properly. All working components can be replaced with the trap body remaining in-line. With superheated steam, a check valve should be installed at inlet or trap may lose prime. A replacement kit containing the lever and seat assembly is a more economical option than replacing the entire steam trap. Also available are replacement screens, gaskets and buckets. When ordering replacement lever and seat assemblies, specify model and operating pressure. See Replacement Parts and Kits Section for exact cross-reference to Armstrong PCA (Pressure Change Assembly) kits.\u003c\/p\u003e\u003ch2\u003eOptions\u003c\/h2\u003e\u003cp\u003eStrainer and Blowdown valve connection available on 1041, 1042, 1044 \u0026amp; 1038S. We also have 3 accessories for this trap are Thermic vent to improve air handling capability. Internal check valve for superheated or condensate backflow applications.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow to Order Accessories:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCheck Valve (Suffix \u003cstrong\u003eCV\u003c\/strong\u003e) Built-in Inlet Check Valve is recommended when used on Superheated Steam\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent (Suffix \u003cstrong\u003eTV\u003c\/strong\u003e) A Thermic Vent is recommended when using a Bucket Trap on any type of process application or where the removal of air from the system is critical.\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent \u0026amp; Check Valve (Suffix \u003cstrong\u003eTCV\u003c\/strong\u003e) For combination of Check Valve \u0026amp; Thermic Vent\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eModel\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1032\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSizes\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\"\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eConnections\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eNPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Material\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eCast Iron\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eInternal check valve, Thermic vent\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMO Max. Operating Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e15 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMO Max. Operating Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMA Max. Allowable Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 PSIG up to 450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMA Max. Allowable Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F @ 250 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eIB1032-12-N-015-TV\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap-Spec-Sheet.pdf?v=1786494449\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"Watson McDaniel","offers":[{"title":"Default Title","offer_id":44165900632142,"sku":"IB1032-12-N-015-TV","price":608.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1032-Inverted-Bucket-Steam-Trap__61630.1784299744.1280.1280.jpg?v=1786663465"},{"product_id":"watson-mcdaniel-ib1032-12-n-015-tcv-inverted-bucket-steam-trap-cast-iron-body-15-psig-in-line-repairability-npt","title":"Watson McDaniel IB1032-12-N-015-TCV Inverted Bucket Steam Trap, Cast Iron Body, 15 PSIG, In-line Repairability, NPT","description":"\u003ch2\u003eWatson McDaniel IB1032-12-N-015-TCV Inverted Bucket Steam Trap - 1\/2\" NPT (15 PSIG)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWaterhammer resistant\u003c\/li\u003e\n\u003cli\u003eSuitable for superheated steam (Use internal check valve option to eliminate loss of prime)\u003c\/li\u003e\n\u003cli\u003eIn-line repairability is simplified by having all internals attached to the cover\u003c\/li\u003e\n\u003cli\u003eValve \u0026amp; seat are located at the top of the trap body making them less prone to clogging from debris and pipe scale\u003c\/li\u003e\n\u003cli\u003eAll stainless steel internals with hardened valve \u0026amp; seat\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eIB1032 Series\u003c\/h2\u003e\u003cp\u003eThe IB1032 series has a larger capacity than the IB1031. It has a max operating pressure (PMO) of 250 PSIG and at max differential pressure, it can handle up to 1,060 lbs\/hr of condensate.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDRIP, TRACING, PROCESS:\u003c\/strong\u003e IB Series inverted bucket steam traps are used in drip applications to remove condensate from steam mains and steam supply lines. For drip applications, the smaller sized units have adequate capacity. The discharge orifice of the inverted bucket trap is mounted at the top of the trap body, which makes them less susceptible to failure from dirt and debris when compared to other trap types. Since Inverted Bucket traps have poor air-handling capability, they are normally not recommended for most process applications. However, they can be used on certain process applications such as unit heaters and laundry equipment,where discharging air during system start-up is not a critical factor. F\u0026amp;T traps are the preferred choice for systems where air must be quickly discharged.\u003c\/p\u003e\u003ch2\u003eHow It Works\u003c\/h2\u003e\u003cp\u003eWhen the trap is filled with condensate, the inverted bucket inside the steam trap loses its buoyancy and rests on the bottom of the trap. This pulls the disc off the seat allowing condensate to be discharged through the seat orifice located at the top of the trap. When steam enters, it fills the inverted bucket causing the bucket to float to the surface which closes the discharge valve, containing the steam in the system. Eventually, the steam is bled off through a small hole in the top of the bucket causing it to sink, which repeats the cycle.\u003c\/p\u003e\u003ch2\u003eSelection \/ Sizing \/ Capacities\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eSelect a model with a higher maximum operating pressure (PMO)\u003c\/strong\u003e that meet or exceed the maximum steam pressure or the trap may not open. For example, the IB-1031-13-N-150 has a Max PMO of 150 PSI, will handle capacity up to 570 lbs\/hr at Maximum. Choose a model that will handle the capacity requirement based on the differential pressure across the trap. Reference capacity charts.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eExample:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eApplication: 100 lbs\/hr at 75 PSIG working pressure and 2 PSI differential pressure\u003c\/li\u003e\n\u003cli\u003eSize\/Model: IB1031, 80 PSIG, Specify pipe size (1\/2\", 3\/4\"), or IB1041, 80 PSIG, Specify pipe size (3\/4\", 1\").\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e\u003cp\u003eTrap must be installed in upright position to function properly. All working components can be replaced with the trap body remaining in-line. With superheated steam, a check valve should be installed at inlet or trap may lose prime. A replacement kit containing the lever and seat assembly is a more economical option than replacing the entire steam trap. Also available are replacement screens, gaskets and buckets. When ordering replacement lever and seat assemblies, specify model and operating pressure. See Replacement Parts and Kits Section for exact cross-reference to Armstrong PCA (Pressure Change Assembly) kits.\u003c\/p\u003e\u003ch2\u003eOptions\u003c\/h2\u003e\u003cp\u003eStrainer and Blowdown valve connection available on 1041, 1042, 1044 \u0026amp; 1038S. We also have 3 accessories for this trap are Thermic vent to improve air handling capability. Internal check valve for superheated or condensate backflow applications.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow to Order Accessories:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCheck Valve (Suffix \u003cstrong\u003eCV\u003c\/strong\u003e) Built-in Inlet Check Valve is recommended when used on Superheated Steam\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent (Suffix \u003cstrong\u003eTV\u003c\/strong\u003e) A Thermic Vent is recommended when using a Bucket Trap on any type of process application or where the removal of air from the system is critical.\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent \u0026amp; Check Valve (Suffix \u003cstrong\u003eTCV\u003c\/strong\u003e) For combination of Check Valve \u0026amp; Thermic Vent\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eModel\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1032\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSizes\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\"\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eConnections\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eNPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Material\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eCast Iron\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eInternal check valve, Thermic vent\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMO Max. Operating Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e15 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMO Max. Operating Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMA Max. Allowable Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 PSIG up to 450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMA Max. Allowable Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F @ 250 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eIB1032-12-N-015-TCV\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap-Spec-Sheet.pdf?v=1786494449\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"Watson McDaniel","offers":[{"title":"Default Title","offer_id":44165900697678,"sku":"IB1032-12-N-015-TCV","price":763.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1032-Inverted-Bucket-Steam-Trap__84256.1784299744.1280.1280.jpg?v=1786663468"},{"product_id":"watson-mcdaniel-ib1032-series-inverted-bucket-steam-trap-cast-iron-body-30-psig-in-line-repairability-1-2-npt","title":"Watson McDaniel IB1032 Series Inverted Bucket Steam Trap, Cast Iron Body, 30 PSIG, In-line Repairability, 1\/2\" NPT","description":"\u003ch2\u003eWatson McDaniel IB1032 Series Inverted Bucket Steam Trap - 1\/2\" NPT (30 PSIG)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWaterhammer resistant\u003c\/li\u003e\n\u003cli\u003eSuitable for superheated steam (Use internal check valve option to eliminate loss of prime)\u003c\/li\u003e\n\u003cli\u003eIn-line repairability is simplified by having all internals attached to the cover\u003c\/li\u003e\n\u003cli\u003eValve \u0026amp; seat are located at the top of the trap body making them less prone to clogging from debris and pipe scale\u003c\/li\u003e\n\u003cli\u003eAll stainless steel internals with hardened valve \u0026amp; seat\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eIB1032 Series\u003c\/h2\u003e\u003cp\u003eThe IB1032 series has a larger capacity than the IB1031. It has a max operating pressure (PMO) of 250 PSIG and at max differential pressure, it can handle up to 1,060 lbs\/hr of condensate.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDRIP, TRACING, PROCESS:\u003c\/strong\u003e IB Series inverted bucket steam traps are used in drip applications to remove condensate from steam mains and steam supply lines. For drip applications, the smaller sized units have adequate capacity. The discharge orifice of the inverted bucket trap is mounted at the top of the trap body, which makes them less susceptible to failure from dirt and debris when compared to other trap types. Since Inverted Bucket traps have poor air-handling capability, they are normally not recommended for most process applications. However, they can be used on certain process applications such as unit heaters and laundry equipment,where discharging air during system start-up is not a critical factor. F\u0026amp;T traps are the preferred choice for systems where air must be quickly discharged.\u003c\/p\u003e\u003ch2\u003eHow It Works\u003c\/h2\u003e\u003cp\u003eWhen the trap is filled with condensate, the inverted bucket inside the steam trap loses its buoyancy and rests on the bottom of the trap. This pulls the disc off the seat allowing condensate to be discharged through the seat orifice located at the top of the trap. When steam enters, it fills the inverted bucket causing the bucket to float to the surface which closes the discharge valve, containing the steam in the system. Eventually, the steam is bled off through a small hole in the top of the bucket causing it to sink, which repeats the cycle.\u003c\/p\u003e\u003ch2\u003eSelection \/ Sizing \/ Capacities\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eSelect a model with a higher maximum operating pressure (PMO)\u003c\/strong\u003e that meet or exceed the maximum steam pressure or the trap may not open. For example, the IB-1031-13-N-150 has a Max PMO of 150 PSI, will handle capacity up to 570 lbs\/hr at Maximum. Choose a model that will handle the capacity requirement based on the differential pressure across the trap. Reference capacity charts.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eExample:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eApplication: 100 lbs\/hr at 75 PSIG working pressure and 2 PSI differential pressure\u003c\/li\u003e\n\u003cli\u003eSize\/Model: IB1031, 80 PSIG, Specify pipe size (1\/2\", 3\/4\"), or IB1041, 80 PSIG, Specify pipe size (3\/4\", 1\").\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e\u003cp\u003eTrap must be installed in upright position to function properly. All working components can be replaced with the trap body remaining in-line. With superheated steam, a check valve should be installed at inlet or trap may lose prime. A replacement kit containing the lever and seat assembly is a more economical option than replacing the entire steam trap. Also available are replacement screens, gaskets and buckets. When ordering replacement lever and seat assemblies, specify model and operating pressure. See Replacement Parts and Kits Section for exact cross-reference to Armstrong PCA (Pressure Change Assembly) kits.\u003c\/p\u003e\u003ch2\u003eOptions\u003c\/h2\u003e\u003cp\u003eStrainer and Blowdown valve connection available on 1041, 1042, 1044 \u0026amp; 1038S. We also have 3 accessories for this trap are Thermic vent to improve air handling capability. Internal check valve for superheated or condensate backflow applications.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow to Order Accessories:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCheck Valve (Suffix \u003cstrong\u003eCV\u003c\/strong\u003e) Built-in Inlet Check Valve is recommended when used on Superheated Steam\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent (Suffix \u003cstrong\u003eTV\u003c\/strong\u003e) A Thermic Vent is recommended when using a Bucket Trap on any type of process application or where the removal of air from the system is critical.\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent \u0026amp; Check Valve (Suffix \u003cstrong\u003eTCV\u003c\/strong\u003e) For combination of Check Valve \u0026amp; Thermic Vent\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eModel\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1032\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSizes\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\"\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eConnections\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eNPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Material\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eCast Iron\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eInternal check valve, Thermic vent\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMO Max. Operating Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e30 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMO Max. Operating Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMA Max. Allowable Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 PSIG up to 450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMA Max. Allowable Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F @ 250 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap-Spec-Sheet.pdf?v=1786494449\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"Watson McDaniel","offers":[{"title":"Default Title","offer_id":44165900763214,"sku":"WM-IB1032-12-N-030","price":301.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1032-Inverted-Bucket-Steam-Trap__46068.1784299721.1280.1280.jpg?v=1786663470"},{"product_id":"watson-mcdaniel-ib1032-12-n-030-inverted-bucket-steam-trap-cast-iron-body-30-psig-in-line-repairability-npt","title":"Watson McDaniel IB1032-12-N-030 Inverted Bucket Steam Trap, Cast Iron Body, 30 PSIG, In-line Repairability, NPT","description":"\u003ch2\u003eWatson McDaniel IB1032-12-N-030 Inverted Bucket Steam Trap - 1\/2\" NPT (30 PSIG)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWaterhammer resistant\u003c\/li\u003e\n\u003cli\u003eSuitable for superheated steam (Use internal check valve option to eliminate loss of prime)\u003c\/li\u003e\n\u003cli\u003eIn-line repairability is simplified by having all internals attached to the cover\u003c\/li\u003e\n\u003cli\u003eValve \u0026amp; seat are located at the top of the trap body making them less prone to clogging from debris and pipe scale\u003c\/li\u003e\n\u003cli\u003eAll stainless steel internals with hardened valve \u0026amp; seat\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eIB1032 Series\u003c\/h2\u003e\u003cp\u003eThe IB1032 series has a larger capacity than the IB1031. It has a max operating pressure (PMO) of 250 PSIG and at max differential pressure, it can handle up to 1,060 lbs\/hr of condensate.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDRIP, TRACING, PROCESS:\u003c\/strong\u003e IB Series inverted bucket steam traps are used in drip applications to remove condensate from steam mains and steam supply lines. For drip applications, the smaller sized units have adequate capacity. The discharge orifice of the inverted bucket trap is mounted at the top of the trap body, which makes them less susceptible to failure from dirt and debris when compared to other trap types. Since Inverted Bucket traps have poor air-handling capability, they are normally not recommended for most process applications. However, they can be used on certain process applications such as unit heaters and laundry equipment,where discharging air during system start-up is not a critical factor. F\u0026amp;T traps are the preferred choice for systems where air must be quickly discharged.\u003c\/p\u003e\u003ch2\u003eHow It Works\u003c\/h2\u003e\u003cp\u003eWhen the trap is filled with condensate, the inverted bucket inside the steam trap loses its buoyancy and rests on the bottom of the trap. This pulls the disc off the seat allowing condensate to be discharged through the seat orifice located at the top of the trap. When steam enters, it fills the inverted bucket causing the bucket to float to the surface which closes the discharge valve, containing the steam in the system. Eventually, the steam is bled off through a small hole in the top of the bucket causing it to sink, which repeats the cycle.\u003c\/p\u003e\u003ch2\u003eSelection \/ Sizing \/ Capacities\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eSelect a model with a higher maximum operating pressure (PMO)\u003c\/strong\u003e that meet or exceed the maximum steam pressure or the trap may not open. For example, the IB-1031-13-N-150 has a Max PMO of 150 PSI, will handle capacity up to 570 lbs\/hr at Maximum. Choose a model that will handle the capacity requirement based on the differential pressure across the trap. Reference capacity charts.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eExample:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eApplication: 100 lbs\/hr at 75 PSIG working pressure and 2 PSI differential pressure\u003c\/li\u003e\n\u003cli\u003eSize\/Model: IB1031, 80 PSIG, Specify pipe size (1\/2\", 3\/4\"), or IB1041, 80 PSIG, Specify pipe size (3\/4\", 1\").\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e\u003cp\u003eTrap must be installed in upright position to function properly. All working components can be replaced with the trap body remaining in-line. With superheated steam, a check valve should be installed at inlet or trap may lose prime. A replacement kit containing the lever and seat assembly is a more economical option than replacing the entire steam trap. Also available are replacement screens, gaskets and buckets. When ordering replacement lever and seat assemblies, specify model and operating pressure. See Replacement Parts and Kits Section for exact cross-reference to Armstrong PCA (Pressure Change Assembly) kits.\u003c\/p\u003e\u003ch2\u003eOptions\u003c\/h2\u003e\u003cp\u003eStrainer and Blowdown valve connection available on 1041, 1042, 1044 \u0026amp; 1038S. We also have 3 accessories for this trap are Thermic vent to improve air handling capability. Internal check valve for superheated or condensate backflow applications.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow to Order Accessories:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCheck Valve (Suffix \u003cstrong\u003eCV\u003c\/strong\u003e) Built-in Inlet Check Valve is recommended when used on Superheated Steam\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent (Suffix \u003cstrong\u003eTV\u003c\/strong\u003e) A Thermic Vent is recommended when using a Bucket Trap on any type of process application or where the removal of air from the system is critical.\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent \u0026amp; Check Valve (Suffix \u003cstrong\u003eTCV\u003c\/strong\u003e) For combination of Check Valve \u0026amp; Thermic Vent\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eModel\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1032\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSizes\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\"\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eConnections\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eNPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Material\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eCast Iron\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eInternal check valve, Thermic vent\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMO Max. Operating Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e30 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMO Max. Operating Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMA Max. Allowable Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 PSIG up to 450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMA Max. Allowable Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F @ 250 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eIB1032-12-N-030\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap-Spec-Sheet.pdf?v=1786494449\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"Watson McDaniel","offers":[{"title":"Default Title","offer_id":44165900828750,"sku":"IB1032-12-N-030","price":301.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1032-Inverted-Bucket-Steam-Trap__38433.1784299721.1280.1280.jpg?v=1786663472"},{"product_id":"watson-mcdaniel-ib1032-12-n-030-cv-inverted-bucket-steam-trap-cast-iron-body-30-psig-in-line-repairability-npt","title":"Watson McDaniel IB1032-12-N-030-CV Inverted Bucket Steam Trap, Cast Iron Body, 30 PSIG, In-line Repairability, NPT","description":"\u003ch2\u003eWatson McDaniel IB1032-12-N-030-CV Inverted Bucket Steam Trap - 1\/2\" NPT (30 PSIG)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWaterhammer resistant\u003c\/li\u003e\n\u003cli\u003eSuitable for superheated steam (Use internal check valve option to eliminate loss of prime)\u003c\/li\u003e\n\u003cli\u003eIn-line repairability is simplified by having all internals attached to the cover\u003c\/li\u003e\n\u003cli\u003eValve \u0026amp; seat are located at the top of the trap body making them less prone to clogging from debris and pipe scale\u003c\/li\u003e\n\u003cli\u003eAll stainless steel internals with hardened valve \u0026amp; seat\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eIB1032 Series\u003c\/h2\u003e\u003cp\u003eThe IB1032 series has a larger capacity than the IB1031. It has a max operating pressure (PMO) of 250 PSIG and at max differential pressure, it can handle up to 1,060 lbs\/hr of condensate.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDRIP, TRACING, PROCESS:\u003c\/strong\u003e IB Series inverted bucket steam traps are used in drip applications to remove condensate from steam mains and steam supply lines. For drip applications, the smaller sized units have adequate capacity. The discharge orifice of the inverted bucket trap is mounted at the top of the trap body, which makes them less susceptible to failure from dirt and debris when compared to other trap types. Since Inverted Bucket traps have poor air-handling capability, they are normally not recommended for most process applications. However, they can be used on certain process applications such as unit heaters and laundry equipment,where discharging air during system start-up is not a critical factor. F\u0026amp;T traps are the preferred choice for systems where air must be quickly discharged.\u003c\/p\u003e\u003ch2\u003eHow It Works\u003c\/h2\u003e\u003cp\u003eWhen the trap is filled with condensate, the inverted bucket inside the steam trap loses its buoyancy and rests on the bottom of the trap. This pulls the disc off the seat allowing condensate to be discharged through the seat orifice located at the top of the trap. When steam enters, it fills the inverted bucket causing the bucket to float to the surface which closes the discharge valve, containing the steam in the system. Eventually, the steam is bled off through a small hole in the top of the bucket causing it to sink, which repeats the cycle.\u003c\/p\u003e\u003ch2\u003eSelection \/ Sizing \/ Capacities\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eSelect a model with a higher maximum operating pressure (PMO)\u003c\/strong\u003e that meet or exceed the maximum steam pressure or the trap may not open. For example, the IB-1031-13-N-150 has a Max PMO of 150 PSI, will handle capacity up to 570 lbs\/hr at Maximum. Choose a model that will handle the capacity requirement based on the differential pressure across the trap. Reference capacity charts.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eExample:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eApplication: 100 lbs\/hr at 75 PSIG working pressure and 2 PSI differential pressure\u003c\/li\u003e\n\u003cli\u003eSize\/Model: IB1031, 80 PSIG, Specify pipe size (1\/2\", 3\/4\"), or IB1041, 80 PSIG, Specify pipe size (3\/4\", 1\").\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e\u003cp\u003eTrap must be installed in upright position to function properly. All working components can be replaced with the trap body remaining in-line. With superheated steam, a check valve should be installed at inlet or trap may lose prime. A replacement kit containing the lever and seat assembly is a more economical option than replacing the entire steam trap. Also available are replacement screens, gaskets and buckets. When ordering replacement lever and seat assemblies, specify model and operating pressure. See Replacement Parts and Kits Section for exact cross-reference to Armstrong PCA (Pressure Change Assembly) kits.\u003c\/p\u003e\u003ch2\u003eOptions\u003c\/h2\u003e\u003cp\u003eStrainer and Blowdown valve connection available on 1041, 1042, 1044 \u0026amp; 1038S. We also have 3 accessories for this trap are Thermic vent to improve air handling capability. Internal check valve for superheated or condensate backflow applications.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow to Order Accessories:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCheck Valve (Suffix \u003cstrong\u003eCV\u003c\/strong\u003e) Built-in Inlet Check Valve is recommended when used on Superheated Steam\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent (Suffix \u003cstrong\u003eTV\u003c\/strong\u003e) A Thermic Vent is recommended when using a Bucket Trap on any type of process application or where the removal of air from the system is critical.\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent \u0026amp; Check Valve (Suffix \u003cstrong\u003eTCV\u003c\/strong\u003e) For combination of Check Valve \u0026amp; Thermic Vent\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eModel\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1032\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSizes\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\"\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eConnections\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eNPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Material\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eCast Iron\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eInternal check valve, Thermic vent\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMO Max. Operating Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e30 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMO Max. Operating Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMA Max. Allowable Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 PSIG up to 450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMA Max. Allowable Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F @ 250 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eIB1032-12-N-030-CV\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap-Spec-Sheet.pdf?v=1786494449\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"Watson McDaniel","offers":[{"title":"Default Title","offer_id":44165900894286,"sku":"IB1032-12-N-030-CV","price":439.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1032-Inverted-Bucket-Steam-Trap__07225.1784299744.1280.1280.jpg?v=1786663474"},{"product_id":"watson-mcdaniel-ib1032-12-n-030-tv-inverted-bucket-steam-trap-cast-iron-body-30-psig-in-line-repairability-npt","title":"Watson McDaniel IB1032-12-N-030-TV Inverted Bucket Steam Trap, Cast Iron Body, 30 PSIG, In-line Repairability, NPT","description":"\u003ch2\u003eWatson McDaniel IB1032-12-N-030-TV Inverted Bucket Steam Trap - 1\/2\" NPT (30 PSIG)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWaterhammer resistant\u003c\/li\u003e\n\u003cli\u003eSuitable for superheated steam (Use internal check valve option to eliminate loss of prime)\u003c\/li\u003e\n\u003cli\u003eIn-line repairability is simplified by having all internals attached to the cover\u003c\/li\u003e\n\u003cli\u003eValve \u0026amp; seat are located at the top of the trap body making them less prone to clogging from debris and pipe scale\u003c\/li\u003e\n\u003cli\u003eAll stainless steel internals with hardened valve \u0026amp; seat\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eIB1032 Series\u003c\/h2\u003e\u003cp\u003eThe IB1032 series has a larger capacity than the IB1031. It has a max operating pressure (PMO) of 250 PSIG and at max differential pressure, it can handle up to 1,060 lbs\/hr of condensate.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDRIP, TRACING, PROCESS:\u003c\/strong\u003e IB Series inverted bucket steam traps are used in drip applications to remove condensate from steam mains and steam supply lines. For drip applications, the smaller sized units have adequate capacity. The discharge orifice of the inverted bucket trap is mounted at the top of the trap body, which makes them less susceptible to failure from dirt and debris when compared to other trap types. Since Inverted Bucket traps have poor air-handling capability, they are normally not recommended for most process applications. However, they can be used on certain process applications such as unit heaters and laundry equipment,where discharging air during system start-up is not a critical factor. F\u0026amp;T traps are the preferred choice for systems where air must be quickly discharged.\u003c\/p\u003e\u003ch2\u003eHow It Works\u003c\/h2\u003e\u003cp\u003eWhen the trap is filled with condensate, the inverted bucket inside the steam trap loses its buoyancy and rests on the bottom of the trap. This pulls the disc off the seat allowing condensate to be discharged through the seat orifice located at the top of the trap. When steam enters, it fills the inverted bucket causing the bucket to float to the surface which closes the discharge valve, containing the steam in the system. Eventually, the steam is bled off through a small hole in the top of the bucket causing it to sink, which repeats the cycle.\u003c\/p\u003e\u003ch2\u003eSelection \/ Sizing \/ Capacities\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eSelect a model with a higher maximum operating pressure (PMO)\u003c\/strong\u003e that meet or exceed the maximum steam pressure or the trap may not open. For example, the IB-1031-13-N-150 has a Max PMO of 150 PSI, will handle capacity up to 570 lbs\/hr at Maximum. Choose a model that will handle the capacity requirement based on the differential pressure across the trap. Reference capacity charts.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eExample:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eApplication: 100 lbs\/hr at 75 PSIG working pressure and 2 PSI differential pressure\u003c\/li\u003e\n\u003cli\u003eSize\/Model: IB1031, 80 PSIG, Specify pipe size (1\/2\", 3\/4\"), or IB1041, 80 PSIG, Specify pipe size (3\/4\", 1\").\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e\u003cp\u003eTrap must be installed in upright position to function properly. All working components can be replaced with the trap body remaining in-line. With superheated steam, a check valve should be installed at inlet or trap may lose prime. A replacement kit containing the lever and seat assembly is a more economical option than replacing the entire steam trap. Also available are replacement screens, gaskets and buckets. When ordering replacement lever and seat assemblies, specify model and operating pressure. See Replacement Parts and Kits Section for exact cross-reference to Armstrong PCA (Pressure Change Assembly) kits.\u003c\/p\u003e\u003ch2\u003eOptions\u003c\/h2\u003e\u003cp\u003eStrainer and Blowdown valve connection available on 1041, 1042, 1044 \u0026amp; 1038S. We also have 3 accessories for this trap are Thermic vent to improve air handling capability. Internal check valve for superheated or condensate backflow applications.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow to Order Accessories:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCheck Valve (Suffix \u003cstrong\u003eCV\u003c\/strong\u003e) Built-in Inlet Check Valve is recommended when used on Superheated Steam\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent (Suffix \u003cstrong\u003eTV\u003c\/strong\u003e) A Thermic Vent is recommended when using a Bucket Trap on any type of process application or where the removal of air from the system is critical.\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent \u0026amp; Check Valve (Suffix \u003cstrong\u003eTCV\u003c\/strong\u003e) For combination of Check Valve \u0026amp; Thermic Vent\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eModel\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1032\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSizes\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\"\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eConnections\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eNPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Material\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eCast Iron\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eInternal check valve, Thermic vent\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMO Max. Operating Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e30 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMO Max. Operating Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMA Max. Allowable Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 PSIG up to 450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMA Max. Allowable Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F @ 250 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eIB1032-12-N-030-TV\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap-Spec-Sheet.pdf?v=1786494449\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"Watson McDaniel","offers":[{"title":"Default Title","offer_id":44165900992590,"sku":"IB1032-12-N-030-TV","price":608.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1032-Inverted-Bucket-Steam-Trap__25192.1784299744.1280.1280.jpg?v=1786663477"},{"product_id":"watson-mcdaniel-ib1032-12-n-030-tcv-inverted-bucket-steam-trap-cast-iron-body-30-psig-in-line-repairability-npt","title":"Watson McDaniel IB1032-12-N-030-TCV Inverted Bucket Steam Trap, Cast Iron Body, 30 PSIG, In-line Repairability, NPT","description":"\u003ch2\u003eWatson McDaniel IB1032-12-N-030-TCV Inverted Bucket Steam Trap - 1\/2\" NPT (30 PSIG)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWaterhammer resistant\u003c\/li\u003e\n\u003cli\u003eSuitable for superheated steam (Use internal check valve option to eliminate loss of prime)\u003c\/li\u003e\n\u003cli\u003eIn-line repairability is simplified by having all internals attached to the cover\u003c\/li\u003e\n\u003cli\u003eValve \u0026amp; seat are located at the top of the trap body making them less prone to clogging from debris and pipe scale\u003c\/li\u003e\n\u003cli\u003eAll stainless steel internals with hardened valve \u0026amp; seat\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eIB1032 Series\u003c\/h2\u003e\u003cp\u003eThe IB1032 series has a larger capacity than the IB1031. It has a max operating pressure (PMO) of 250 PSIG and at max differential pressure, it can handle up to 1,060 lbs\/hr of condensate.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDRIP, TRACING, PROCESS:\u003c\/strong\u003e IB Series inverted bucket steam traps are used in drip applications to remove condensate from steam mains and steam supply lines. For drip applications, the smaller sized units have adequate capacity. The discharge orifice of the inverted bucket trap is mounted at the top of the trap body, which makes them less susceptible to failure from dirt and debris when compared to other trap types. Since Inverted Bucket traps have poor air-handling capability, they are normally not recommended for most process applications. However, they can be used on certain process applications such as unit heaters and laundry equipment,where discharging air during system start-up is not a critical factor. F\u0026amp;T traps are the preferred choice for systems where air must be quickly discharged.\u003c\/p\u003e\u003ch2\u003eHow It Works\u003c\/h2\u003e\u003cp\u003eWhen the trap is filled with condensate, the inverted bucket inside the steam trap loses its buoyancy and rests on the bottom of the trap. This pulls the disc off the seat allowing condensate to be discharged through the seat orifice located at the top of the trap. When steam enters, it fills the inverted bucket causing the bucket to float to the surface which closes the discharge valve, containing the steam in the system. Eventually, the steam is bled off through a small hole in the top of the bucket causing it to sink, which repeats the cycle.\u003c\/p\u003e\u003ch2\u003eSelection \/ Sizing \/ Capacities\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eSelect a model with a higher maximum operating pressure (PMO)\u003c\/strong\u003e that meet or exceed the maximum steam pressure or the trap may not open. For example, the IB-1031-13-N-150 has a Max PMO of 150 PSI, will handle capacity up to 570 lbs\/hr at Maximum. Choose a model that will handle the capacity requirement based on the differential pressure across the trap. Reference capacity charts.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eExample:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eApplication: 100 lbs\/hr at 75 PSIG working pressure and 2 PSI differential pressure\u003c\/li\u003e\n\u003cli\u003eSize\/Model: IB1031, 80 PSIG, Specify pipe size (1\/2\", 3\/4\"), or IB1041, 80 PSIG, Specify pipe size (3\/4\", 1\").\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e\u003cp\u003eTrap must be installed in upright position to function properly. All working components can be replaced with the trap body remaining in-line. With superheated steam, a check valve should be installed at inlet or trap may lose prime. A replacement kit containing the lever and seat assembly is a more economical option than replacing the entire steam trap. Also available are replacement screens, gaskets and buckets. When ordering replacement lever and seat assemblies, specify model and operating pressure. See Replacement Parts and Kits Section for exact cross-reference to Armstrong PCA (Pressure Change Assembly) kits.\u003c\/p\u003e\u003ch2\u003eOptions\u003c\/h2\u003e\u003cp\u003eStrainer and Blowdown valve connection available on 1041, 1042, 1044 \u0026amp; 1038S. We also have 3 accessories for this trap are Thermic vent to improve air handling capability. Internal check valve for superheated or condensate backflow applications.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow to Order Accessories:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCheck Valve (Suffix \u003cstrong\u003eCV\u003c\/strong\u003e) Built-in Inlet Check Valve is recommended when used on Superheated Steam\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent (Suffix \u003cstrong\u003eTV\u003c\/strong\u003e) A Thermic Vent is recommended when using a Bucket Trap on any type of process application or where the removal of air from the system is critical.\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermic Vent \u0026amp; Check Valve (Suffix \u003cstrong\u003eTCV\u003c\/strong\u003e) For combination of Check Valve \u0026amp; Thermic Vent\u003cbr\u003e\u003cul\u003e\u003cli\u003eExample: IB1031-12-N-125-\u003cstrong\u003eTCV\u003c\/strong\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eModel\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1032\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSizes\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\"\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eConnections\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eNPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Material\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eCast Iron\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eInternal check valve, Thermic vent\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMO Max. Operating Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e30 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMO Max. Operating Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMA Max. Allowable Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 PSIG up to 450°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMA Max. Allowable Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450°F @ 250 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eIB1032-12-N-030-TCV\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap-Spec-Sheet.pdf?v=1786494449\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"Watson McDaniel","offers":[{"title":"Default Title","offer_id":44165901058126,"sku":"IB1032-12-N-030-TCV","price":763.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-IB1032-Inverted-Bucket-Steam-Trap__10563.1784299744.1280.1280.jpg?v=1786663479"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/collections\/Watson-McDaniel-IB1031-Inverted-Bucket-Steam-Trap__17988.1784299742.1280.1280.jpg?v=1787607398","url":"https:\/\/valveman.com\/collections\/inverted-bucket.oembed","provider":"ValveMan","version":"1.0","type":"link"}