{"title":"Reduced Pressure Detector Assemblies","description":null,"products":[{"product_id":"watts-lf957-series-lead-free-stainless-steel-reduced-pressure-detector-backflow-preventer-assembly-osy-gate-valve-shutoff-gallons-minute-meter-backflow-flood-sensor","title":"Watts LF957 Series, Lead-Free Stainless Steel, Reduced Pressure Detector Backflow Preventer Assembly, OSY Gate Valve Shutoff, Gallons\/Minute Meter, Backflow Flood Sensor","description":"\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eWatts LF957 Series Reduced Pressure Detector Backflow Preventer Assembly, OSY Gate Valve Shutoff, Backflow Flood Sensor\u003c\/h2\u003e\n\u003ch2\u003eFeatures \u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFeatures a flood sensor with SentryPlus Alert technology to detect excessive water discharges from the relief valve\u003c\/li\u003e\n\u003cli\u003eAlert features available with add-on sensor connection kit\u003c\/li\u003e\n\u003cli\u003eStainless steel housing and sleeve\u003c\/li\u003e\n\u003cli\u003eUL and FM outside stem and yoke resilient seated gate valves\u003c\/li\u003e\n\u003cli\u003eFurnished with a gallon per minute meter\u003c\/li\u003e\n\u003cli\u003eReplaceable check disc rubber\u003c\/li\u003e\n\u003cli\u003eCompact construction for smaller enclosures\u003c\/li\u003e\n\u003cli\u003eBottom mounted relief valve reduces clearance requirements when installed against an outside wall\u003c\/li\u003e\n\u003cli\u003eTorsion spring check valves provides maximum flow at low pressure drop\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"column\"\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eItem\u003c\/div\u003e \u003cdiv class=\"right\"\u003eBackflow Preventor\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eSize\u003c\/div\u003e \u003cdiv class=\"right\"\u003e2-1\/2\" to 10\"\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eBackflow Preventer Type\u003c\/div\u003e \u003cdiv class=\"right\"\u003eReduced Pressure Detector\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eEnd Connection\u003c\/div\u003e \u003cdiv class=\"right\"\u003eGrooved Joint\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"column\"\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eBody Pattern\u003c\/div\u003e \u003cdiv class=\"right\"\u003eStraight\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eShutoff\u003c\/div\u003e \u003cdiv class=\"right\"\u003eOutside Yoke \u0026amp; Stem Gate Valve\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eTemp. Range\u003c\/div\u003e \u003cdiv class=\"right\"\u003e33°F to 110°F\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eMax. Working Pressure\u003c\/div\u003e \u003cdiv class=\"right\"\u003e175 psi\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv\u003e\n\u003cbr\u003e \u003ch2\u003eView Specification Sheets Here\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-Series-LF957RPDA-Backflow-Preventer-Secification-Sheet.pdf?v=1786490937\" target='_blank\"'\u003e957 Series Specification Sheet\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-SentryPlus-Alert-Flood-Sensor-Connection-Kit-Specification-Sheet.pdf?v=1786490806\" target='_blank\"'\u003eFlood Sensor Connection Kit Specification Sheet\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e\n\u003ch2\u003eView Installation Manuals Here\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-Series-957-957RPDA-LF957RPDA-Installation-Maintenance-and-Repair-Manual.pdf?v=1786490917\" target='_blank\"'\u003e957 Series Installation, Maintenance and Repair Manual\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-Series-957-Series-BMS-Flood-Sensor-Connection-Kit-Installation-Instructions.pdf?v=1786490922\" target='_blank\"'\u003eBMS Sensor Connection Kit Installation Instructions\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-Series-957-Series-Cellular-Flood-Sensor-Connection-Kit-Installation-Instructions.pdf?v=1786490926\" target='_blank\"'\u003eCellular Sensor Connection Kit Installation Instructions\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Watts","offers":[{"title":"Default Title","offer_id":44165176033358,"sku":"Watts-LF957-OSY-GPM","price":6504.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts_252520LF957RPDAOSY-GPM-FS_252520Backflow_252520Preventer_2525201__03461.1756305138.1280.1280.jpg?v=1786656966"},{"product_id":"2-1-2-watts-lf957rpdaosy-gpm-fs-2-1-2-lead-free-stainless-steel-reduced-pressure-detector-backflow-preventer-assembly-osy-gate-valve-shutoff-gallons-minute-meter-backflow-flood-sensor","title":"2-1\/2\" Watts LF957RPDAOSY-GPM-FS 2 1\/2, Lead-Free Stainless Steel, Reduced Pressure Detector Backflow Preventer Assembly, OSY Gate Valve Shutoff, Gallons\/Minute Meter, Backflow Flood Sensor","description":"\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003e2-1\/2\" Watts LF957RPDAOSY-GPM-FS 2 1\/2 Reduced Pressure Detector Backflow Preventer Assembly, OSY Gate Valve Shutoff, Backflow Flood Sensor\u003c\/h2\u003e\n\u003ch2\u003eFeatures \u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFeatures a flood sensor with SentryPlus Alert technology to detect excessive water discharges from the relief valve\u003c\/li\u003e\n\u003cli\u003eAlert features available with add-on sensor connection kit\u003c\/li\u003e\n\u003cli\u003eStainless steel housing and sleeve\u003c\/li\u003e\n\u003cli\u003eUL and FM outside stem and yoke resilient seated gate valves\u003c\/li\u003e\n\u003cli\u003eFurnished with a gallon per minute meter\u003c\/li\u003e\n\u003cli\u003eReplaceable check disc rubber\u003c\/li\u003e\n\u003cli\u003eCompact construction for smaller enclosures\u003c\/li\u003e\n\u003cli\u003eBottom mounted relief valve reduces clearance requirements when installed against an outside wall\u003c\/li\u003e\n\u003cli\u003eTorsion spring check valves provides maximum flow at low pressure drop\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"column\"\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eItem\u003c\/div\u003e \u003cdiv class=\"right\"\u003eBackflow Preventor\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eSize\u003c\/div\u003e \u003cdiv class=\"right\"\u003e2-1\/2\"\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eBackflow Preventer Type\u003c\/div\u003e \u003cdiv class=\"right\"\u003eReduced Pressure Detector\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eEnd Connection\u003c\/div\u003e \u003cdiv class=\"right\"\u003eGrooved Joint\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"column\"\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eBody Pattern\u003c\/div\u003e \u003cdiv class=\"right\"\u003eStraight\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eShutoff\u003c\/div\u003e \u003cdiv class=\"right\"\u003eOutside Yoke \u0026amp; Stem Gate Valve\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eTemp. Range\u003c\/div\u003e \u003cdiv class=\"right\"\u003e33°F to 110°F\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eMax. Working Pressure\u003c\/div\u003e \u003cdiv class=\"right\"\u003e175 psi\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv\u003e\n\u003cbr\u003e \u003ch2\u003eView Specification Sheets Here\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-Series-LF957RPDA-Backflow-Preventer-Secification-Sheet.pdf?v=1786490937\" target='_blank\"'\u003e957 Series Specification Sheet\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-SentryPlus-Alert-Flood-Sensor-Connection-Kit-Specification-Sheet.pdf?v=1786490806\" target='_blank\"'\u003eFlood Sensor Connection Kit Specification Sheet\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e\n\u003ch2\u003eView Installation Manuals Here\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-Series-957-957RPDA-LF957RPDA-Installation-Maintenance-and-Repair-Manual.pdf?v=1786490917\" target='_blank\"'\u003e957 Series Installation, Maintenance and Repair Manual\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-Series-957-Series-BMS-Flood-Sensor-Connection-Kit-Installation-Instructions.pdf?v=1786490922\" target='_blank\"'\u003eBMS Sensor Connection Kit Installation Instructions\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-Series-957-Series-Cellular-Flood-Sensor-Connection-Kit-Installation-Instructions.pdf?v=1786490926\" target='_blank\"'\u003eCellular Sensor Connection Kit Installation Instructions\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Watts","offers":[{"title":"Default Title","offer_id":44165176328270,"sku":"LF957RPDAOSY-GPM-FS 2 1\/2","price":6504.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts_252520LF957RPDAOSY-GPM-FS_252520Backflow_252520Preventer_2525201__02765.1756305139.1280.1280.jpg?v=1786656969"},{"product_id":"3-watts-lf957rpda-osy-gpm-fs-3-lead-free-stainless-steel-reduced-pressure-detector-backflow-preventer-assembly-osy-gate-valve-shutoff-gallons-minute-meter-backflow-flood-sensor","title":"3\" Watts LF957RPDA-OSY-GPM-FS 3, Lead-Free Stainless Steel, Reduced Pressure Detector Backflow Preventer Assembly, OSY Gate Valve Shutoff, Gallons\/Minute Meter, Backflow Flood Sensor","description":"\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003e3\" Watts LF957RPDA-OSY-GPM-FS 3 Reduced Pressure Detector Backflow Preventer Assembly, OSY Gate Valve Shutoff, Backflow Flood Sensor\u003c\/h2\u003e\n\u003ch2\u003eFeatures \u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFeatures a flood sensor with SentryPlus Alert technology to detect excessive water discharges from the relief valve\u003c\/li\u003e\n\u003cli\u003eAlert features available with add-on sensor connection kit\u003c\/li\u003e\n\u003cli\u003eStainless steel housing and sleeve\u003c\/li\u003e\n\u003cli\u003eUL and FM outside stem and yoke resilient seated gate valves\u003c\/li\u003e\n\u003cli\u003eFurnished with a gallon per minute meter\u003c\/li\u003e\n\u003cli\u003eReplaceable check disc rubber\u003c\/li\u003e\n\u003cli\u003eCompact construction for smaller enclosures\u003c\/li\u003e\n\u003cli\u003eBottom mounted relief valve reduces clearance requirements when installed against an outside wall\u003c\/li\u003e\n\u003cli\u003eTorsion spring check valves provides maximum flow at low pressure drop\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"column\"\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eItem\u003c\/div\u003e \u003cdiv class=\"right\"\u003eBackflow Preventor\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eSize\u003c\/div\u003e \u003cdiv class=\"right\"\u003e3\"\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eBackflow Preventer Type\u003c\/div\u003e \u003cdiv class=\"right\"\u003eReduced Pressure Detector\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eEnd Connection\u003c\/div\u003e \u003cdiv class=\"right\"\u003eGrooved Joint\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"column\"\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eBody Pattern\u003c\/div\u003e \u003cdiv class=\"right\"\u003eStraight\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eShutoff\u003c\/div\u003e \u003cdiv class=\"right\"\u003eOutside Yoke \u0026amp; Stem Gate Valve\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eTemp. Range\u003c\/div\u003e \u003cdiv class=\"right\"\u003e33°F to 110°F\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eMax. Working Pressure\u003c\/div\u003e \u003cdiv class=\"right\"\u003e175 psi\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv\u003e\n\u003cbr\u003e \u003ch2\u003eView Specification Sheets Here\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-Series-LF957RPDA-Backflow-Preventer-Secification-Sheet.pdf?v=1786490937\" target='_blank\"'\u003e957 Series Specification Sheet\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-SentryPlus-Alert-Flood-Sensor-Connection-Kit-Specification-Sheet.pdf?v=1786490806\" target='_blank\"'\u003eFlood Sensor Connection Kit Specification Sheet\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e\n\u003ch2\u003eView Installation Manuals Here\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-Series-957-957RPDA-LF957RPDA-Installation-Maintenance-and-Repair-Manual.pdf?v=1786490917\" target='_blank\"'\u003e957 Series Installation, Maintenance and Repair Manual\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-Series-957-Series-BMS-Flood-Sensor-Connection-Kit-Installation-Instructions.pdf?v=1786490922\" target='_blank\"'\u003eBMS Sensor Connection Kit Installation Instructions\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-Series-957-Series-Cellular-Flood-Sensor-Connection-Kit-Installation-Instructions.pdf?v=1786490926\" target='_blank\"'\u003eCellular Sensor Connection Kit Installation Instructions\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Watts","offers":[{"title":"Default Title","offer_id":44165176721486,"sku":"LF957RPDA-OSY-GPM-FS 3","price":7217.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts_252520LF957RPDAOSY-GPM-FS_252520Backflow_252520Preventer_2525201__72373.1756305140.1280.1280.jpg?v=1786656972"},{"product_id":"4-watts-lf957rpda-osy-gpm-fs-4-lead-free-stainless-steel-reduced-pressure-detector-backflow-preventer-assembly-osy-gate-valve-shutoff-gallons-minute-meter-backflow-flood-sensor","title":"4\" Watts LF957RPDA-OSY-GPM-FS 4, Lead-Free Stainless Steel, Reduced Pressure Detector Backflow Preventer Assembly, OSY Gate Valve Shutoff, Gallons\/Minute Meter, Backflow Flood Sensor","description":"\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003e4\" Watts LF957RPDA-OSY-GPM-FS 4 Reduced Pressure Detector Backflow Preventer Assembly, OSY Gate Valve Shutoff, Backflow Flood Sensor\u003c\/h2\u003e\n\u003ch2\u003eFeatures \u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFeatures a flood sensor with SentryPlus Alert technology to detect excessive water discharges from the relief valve\u003c\/li\u003e\n\u003cli\u003eAlert features available with add-on sensor connection kit\u003c\/li\u003e\n\u003cli\u003eStainless steel housing and sleeve\u003c\/li\u003e\n\u003cli\u003eUL and FM outside stem and yoke resilient seated gate valves\u003c\/li\u003e\n\u003cli\u003eFurnished with a gallon per minute meter\u003c\/li\u003e\n\u003cli\u003eReplaceable check disc rubber\u003c\/li\u003e\n\u003cli\u003eCompact construction for smaller enclosures\u003c\/li\u003e\n\u003cli\u003eBottom mounted relief valve reduces clearance requirements when installed against an outside wall\u003c\/li\u003e\n\u003cli\u003eTorsion spring check valves provides maximum flow at low pressure drop\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"column\"\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eItem\u003c\/div\u003e \u003cdiv class=\"right\"\u003eBackflow Preventor\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eSize\u003c\/div\u003e \u003cdiv class=\"right\"\u003e4\"\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eBackflow Preventer Type\u003c\/div\u003e \u003cdiv class=\"right\"\u003eReduced Pressure Detector\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eEnd Connection\u003c\/div\u003e \u003cdiv class=\"right\"\u003eGrooved Joint\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"column\"\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eBody Pattern\u003c\/div\u003e \u003cdiv class=\"right\"\u003eStraight\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eShutoff\u003c\/div\u003e \u003cdiv class=\"right\"\u003eOutside Yoke \u0026amp; Stem Gate Valve\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eTemp. Range\u003c\/div\u003e \u003cdiv class=\"right\"\u003e33°F to 110°F\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eMax. Working Pressure\u003c\/div\u003e \u003cdiv class=\"right\"\u003e175 psi\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv\u003e\n\u003cbr\u003e \u003ch2\u003eView Specification Sheets Here\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-Series-LF957RPDA-Backflow-Preventer-Secification-Sheet.pdf?v=1786490937\" target='_blank\"'\u003e957 Series Specification Sheet\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-SentryPlus-Alert-Flood-Sensor-Connection-Kit-Specification-Sheet.pdf?v=1786490806\" target='_blank\"'\u003eFlood Sensor Connection Kit Specification Sheet\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e\n\u003ch2\u003eView Installation Manuals Here\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-Series-957-957RPDA-LF957RPDA-Installation-Maintenance-and-Repair-Manual.pdf?v=1786490917\" target='_blank\"'\u003e957 Series Installation, Maintenance and Repair Manual\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-Series-957-Series-BMS-Flood-Sensor-Connection-Kit-Installation-Instructions.pdf?v=1786490922\" target='_blank\"'\u003eBMS Sensor Connection Kit Installation Instructions\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-Series-957-Series-Cellular-Flood-Sensor-Connection-Kit-Installation-Instructions.pdf?v=1786490926\" target='_blank\"'\u003eCellular Sensor Connection Kit Installation Instructions\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Watts","offers":[{"title":"Default Title","offer_id":44165177016398,"sku":"LF957RPDA-OSY-GPM-FS 4","price":7955.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts_252520LF957RPDAOSY-GPM-FS_252520Backflow_252520Preventer_2525201__82431.1756305140.1280.1280.jpg?v=1786656974"},{"product_id":"6-watts-lf957rpda-osy-gpm-fs-6-lead-free-stainless-steel-reduced-pressure-detector-backflow-preventer-assembly-osy-gate-valve-shutoff-gallons-minute-meter-backflow-flood-sensor","title":"6\" Watts LF957RPDA-OSY-GPM-FS 6, Lead-Free Stainless Steel, Reduced Pressure Detector Backflow Preventer Assembly, OSY Gate Valve Shutoff, Gallons\/Minute Meter, Backflow Flood Sensor","description":"\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003e6\" Watts LF957RPDA-OSY-GPM-FS 6 Reduced Pressure Detector Backflow Preventer Assembly, OSY Gate Valve Shutoff, Backflow Flood Sensor\u003c\/h2\u003e\n\u003ch2\u003eFeatures \u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFeatures a flood sensor with SentryPlus Alert technology to detect excessive water discharges from the relief valve\u003c\/li\u003e\n\u003cli\u003eAlert features available with add-on sensor connection kit\u003c\/li\u003e\n\u003cli\u003eStainless steel housing and sleeve\u003c\/li\u003e\n\u003cli\u003eUL and FM outside stem and yoke resilient seated gate valves\u003c\/li\u003e\n\u003cli\u003eFurnished with a gallon per minute meter\u003c\/li\u003e\n\u003cli\u003eReplaceable check disc rubber\u003c\/li\u003e\n\u003cli\u003eCompact construction for smaller enclosures\u003c\/li\u003e\n\u003cli\u003eBottom mounted relief valve reduces clearance requirements when installed against an outside wall\u003c\/li\u003e\n\u003cli\u003eTorsion spring check valves provides maximum flow at low pressure drop\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"column\"\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eItem\u003c\/div\u003e \u003cdiv class=\"right\"\u003eBackflow Preventor\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eSize\u003c\/div\u003e \u003cdiv class=\"right\"\u003e6\"\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eBackflow Preventer Type\u003c\/div\u003e \u003cdiv class=\"right\"\u003eReduced Pressure Detector\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eEnd Connection\u003c\/div\u003e \u003cdiv class=\"right\"\u003eGrooved Joint\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"column\"\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eBody Pattern\u003c\/div\u003e \u003cdiv class=\"right\"\u003eStraight\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eShutoff\u003c\/div\u003e \u003cdiv class=\"right\"\u003eOutside Yoke \u0026amp; Stem Gate Valve\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eTemp. Range\u003c\/div\u003e \u003cdiv class=\"right\"\u003e33°F to 110°F\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eMax. Working Pressure\u003c\/div\u003e \u003cdiv class=\"right\"\u003e175 psi\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv\u003e\n\u003cbr\u003e \u003ch2\u003eView Specification Sheets Here\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-Series-LF957RPDA-Backflow-Preventer-Secification-Sheet.pdf?v=1786490937\" target='_blank\"'\u003e957 Series Specification Sheet\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-SentryPlus-Alert-Flood-Sensor-Connection-Kit-Specification-Sheet.pdf?v=1786490806\" target='_blank\"'\u003eFlood Sensor Connection Kit Specification Sheet\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e\n\u003ch2\u003eView Installation Manuals Here\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-Series-957-957RPDA-LF957RPDA-Installation-Maintenance-and-Repair-Manual.pdf?v=1786490917\" target='_blank\"'\u003e957 Series Installation, Maintenance and Repair Manual\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-Series-957-Series-BMS-Flood-Sensor-Connection-Kit-Installation-Instructions.pdf?v=1786490922\" target='_blank\"'\u003eBMS Sensor Connection Kit Installation Instructions\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-Series-957-Series-Cellular-Flood-Sensor-Connection-Kit-Installation-Instructions.pdf?v=1786490926\" target='_blank\"'\u003eCellular Sensor Connection Kit Installation Instructions\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Watts","offers":[{"title":"Default Title","offer_id":44165177344078,"sku":"LF957RPDA-OSY-GPM-FS 6","price":11357.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts_252520LF957RPDAOSY-GPM-FS_252520Backflow_252520Preventer_2525201__41314.1756305141.1280.1280.jpg?v=1786656976"},{"product_id":"8-watts-lf957rpda-osy-gpm-fs-8-lead-free-stainless-steel-reduced-pressure-detector-backflow-preventer-assembly-osy-gate-valve-shutoff-gallons-minute-meter-backflow-flood-sensor","title":"8\" Watts LF957RPDA-OSY-GPM-FS 8, Lead-Free Stainless Steel, Reduced Pressure Detector Backflow Preventer Assembly, OSY Gate Valve Shutoff, Gallons\/Minute Meter, Backflow Flood Sensor","description":"\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003e8\" Watts LF957RPDA-OSY-GPM-FS 8 Reduced Pressure Detector Backflow Preventer Assembly, OSY Gate Valve Shutoff, Backflow Flood Sensor\u003c\/h2\u003e\n\u003ch2\u003eFeatures \u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFeatures a flood sensor with SentryPlus Alert technology to detect excessive water discharges from the relief valve\u003c\/li\u003e\n\u003cli\u003eAlert features available with add-on sensor connection kit\u003c\/li\u003e\n\u003cli\u003eStainless steel housing and sleeve\u003c\/li\u003e\n\u003cli\u003eUL and FM outside stem and yoke resilient seated gate valves\u003c\/li\u003e\n\u003cli\u003eFurnished with a gallon per minute meter\u003c\/li\u003e\n\u003cli\u003eReplaceable check disc rubber\u003c\/li\u003e\n\u003cli\u003eCompact construction for smaller enclosures\u003c\/li\u003e\n\u003cli\u003eBottom mounted relief valve reduces clearance requirements when installed against an outside wall\u003c\/li\u003e\n\u003cli\u003eTorsion spring check valves provides maximum flow at low pressure drop\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"column\"\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eItem\u003c\/div\u003e \u003cdiv class=\"right\"\u003eBackflow Preventor\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eSize\u003c\/div\u003e \u003cdiv class=\"right\"\u003e8\"\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eBackflow Preventer Type\u003c\/div\u003e \u003cdiv class=\"right\"\u003eReduced Pressure Detector\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eEnd Connection\u003c\/div\u003e \u003cdiv class=\"right\"\u003eGrooved Joint\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"column\"\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eBody Pattern\u003c\/div\u003e \u003cdiv class=\"right\"\u003eStraight\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eShutoff\u003c\/div\u003e \u003cdiv class=\"right\"\u003eOutside Yoke \u0026amp; Stem Gate Valve\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eTemp. Range\u003c\/div\u003e \u003cdiv class=\"right\"\u003e33°F to 110°F\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eMax. Working Pressure\u003c\/div\u003e \u003cdiv class=\"right\"\u003e175 psi\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv\u003e\n\u003cbr\u003e \u003ch2\u003eView Specification Sheets Here\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-Series-LF957RPDA-Backflow-Preventer-Secification-Sheet.pdf?v=1786490937\" target='_blank\"'\u003e957 Series Specification Sheet\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-SentryPlus-Alert-Flood-Sensor-Connection-Kit-Specification-Sheet.pdf?v=1786490806\" target='_blank\"'\u003eFlood Sensor Connection Kit Specification Sheet\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e\n\u003ch2\u003eView Installation Manuals Here\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-Series-957-957RPDA-LF957RPDA-Installation-Maintenance-and-Repair-Manual.pdf?v=1786490917\" target='_blank\"'\u003e957 Series Installation, Maintenance and Repair Manual\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-Series-957-Series-BMS-Flood-Sensor-Connection-Kit-Installation-Instructions.pdf?v=1786490922\" target='_blank\"'\u003eBMS Sensor Connection Kit Installation Instructions\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-Series-957-Series-Cellular-Flood-Sensor-Connection-Kit-Installation-Instructions.pdf?v=1786490926\" target='_blank\"'\u003eCellular Sensor Connection Kit Installation Instructions\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Watts","offers":[{"title":"Default Title","offer_id":44165177638990,"sku":"LF957RPDA-OSY-GPM-FS 8","price":20109.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts_252520LF957RPDAOSY-GPM-FS_252520Backflow_252520Preventer_2525201__50627.1756305141.1280.1280.jpg?v=1786656979"},{"product_id":"10-watts-lf957rpda-osy-gpm-fs-10-lead-free-stainless-steel-reduced-pressure-detector-backflow-preventer-assembly-osy-gate-valve-shutoff-gallons-minute-meter-backflow-flood-sensor","title":"10\" Watts LF957RPDA-OSY-GPM-FS 10, Lead-Free Stainless Steel, Reduced Pressure Detector Backflow Preventer Assembly, OSY Gate Valve Shutoff, Gallons\/Minute Meter, Backflow Flood Sensor","description":"\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003e10\" Watts LF957RPDA-OSY-GPM-FS 10 Reduced Pressure Detector Backflow Preventer Assembly, OSY Gate Valve Shutoff, Backflow Flood Sensor\u003c\/h2\u003e\n\u003ch2\u003eFeatures \u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFeatures a flood sensor with SentryPlus Alert technology to detect excessive water discharges from the relief valve\u003c\/li\u003e\n\u003cli\u003eAlert features available with add-on sensor connection kit\u003c\/li\u003e\n\u003cli\u003eStainless steel housing and sleeve\u003c\/li\u003e\n\u003cli\u003eUL and FM outside stem and yoke resilient seated gate valves\u003c\/li\u003e\n\u003cli\u003eFurnished with a gallon per minute meter\u003c\/li\u003e\n\u003cli\u003eReplaceable check disc rubber\u003c\/li\u003e\n\u003cli\u003eCompact construction for smaller enclosures\u003c\/li\u003e\n\u003cli\u003eBottom mounted relief valve reduces clearance requirements when installed against an outside wall\u003c\/li\u003e\n\u003cli\u003eTorsion spring check valves provides maximum flow at low pressure drop\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"column\"\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eItem\u003c\/div\u003e \u003cdiv class=\"right\"\u003eBackflow Preventor\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eSize\u003c\/div\u003e \u003cdiv class=\"right\"\u003e10\"\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eBackflow Preventer Type\u003c\/div\u003e \u003cdiv class=\"right\"\u003eReduced Pressure Detector\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eEnd Connection\u003c\/div\u003e \u003cdiv class=\"right\"\u003eGrooved Joint\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"column\"\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eBody Pattern\u003c\/div\u003e \u003cdiv class=\"right\"\u003eStraight\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eShutoff\u003c\/div\u003e \u003cdiv class=\"right\"\u003eOutside Yoke \u0026amp; Stem Gate Valve\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eTemp. Range\u003c\/div\u003e \u003cdiv class=\"right\"\u003e33°F to 110°F\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eMax. Working Pressure\u003c\/div\u003e \u003cdiv class=\"right\"\u003e175 psi\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv\u003e\n\u003cbr\u003e \u003ch2\u003eView Specification Sheets Here\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-Series-LF957RPDA-Backflow-Preventer-Secification-Sheet.pdf?v=1786490937\" target='_blank\"'\u003e957 Series Specification Sheet\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-SentryPlus-Alert-Flood-Sensor-Connection-Kit-Specification-Sheet.pdf?v=1786490806\" target='_blank\"'\u003eFlood Sensor Connection Kit Specification Sheet\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e\n\u003ch2\u003eView Installation Manuals Here\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-Series-957-957RPDA-LF957RPDA-Installation-Maintenance-and-Repair-Manual.pdf?v=1786490917\" target='_blank\"'\u003e957 Series Installation, Maintenance and Repair Manual\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-Series-957-Series-BMS-Flood-Sensor-Connection-Kit-Installation-Instructions.pdf?v=1786490922\" target='_blank\"'\u003eBMS Sensor Connection Kit Installation Instructions\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-Series-957-Series-Cellular-Flood-Sensor-Connection-Kit-Installation-Instructions.pdf?v=1786490926\" target='_blank\"'\u003eCellular Sensor Connection Kit Installation Instructions\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Watts","offers":[{"title":"Default Title","offer_id":44165177966670,"sku":"LF957RPDA-OSY-GPM-FS 10","price":26148.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts_252520LF957RPDAOSY-GPM-FS_252520Backflow_252520Preventer_2525201__86605.1756305142.1280.1280.jpg?v=1786656982"},{"product_id":"watts-lf957-series-lead-free-stainless-steel-reduced-pressure-detector-backflow-preventer-assembly-osy-gate-valve-shutoff-less-meter","title":"Watts LF957 Series, Lead-Free Stainless Steel, Reduced Pressure Detector Backflow Preventer Assembly, OSY Gate Valve Shutoff, Less Meter","description":"\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eWatts LF957 Series Reduced Pressure Detector Backflow Preventer Assembly, OSY Gate Valve Shutoff\u003c\/h2\u003e\n\u003ch2\u003eFeatures \u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e304 (Schedule 40) stainless steel housing and sleeve\u003c\/li\u003e\n\u003cli\u003eUL and FM outside stem and yoke resilient seated gate valves\u003c\/li\u003e\n\u003cli\u003eQuick access sleeve\u003c\/li\u003e\n\u003cli\u003eReplaceable check disc rubber\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"column\"\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eItem\u003c\/div\u003e \u003cdiv class=\"right\"\u003eBackflow Preventor\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eSize\u003c\/div\u003e \u003cdiv class=\"right\"\u003e3\" to 8\"\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eBackflow Preventer Type\u003c\/div\u003e \u003cdiv class=\"right\"\u003eReduced Pressure Detector\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eEnd Connection\u003c\/div\u003e \u003cdiv class=\"right\"\u003eGrooved Joint\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"column\"\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eBody Pattern\u003c\/div\u003e \u003cdiv class=\"right\"\u003eStraight\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eShutoff\u003c\/div\u003e \u003cdiv class=\"right\"\u003eOutside Yoke \u0026amp; Stem Gate Valve\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eTemp. Range\u003c\/div\u003e \u003cdiv class=\"right\"\u003e33°F to 110°F\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eMax. Working Pressure\u003c\/div\u003e \u003cdiv class=\"right\"\u003e175 psi\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv\u003e\n\u003cbr\u003e \u003ch2\u003eView Specification Sheets Here\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-Series-LF957RPDA-Backflow-Preventer-Secification-Sheet.pdf?v=1786490937\" target='_blank\"'\u003e957 Series Specification Sheet\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-SentryPlus-Alert-Flood-Sensor-Connection-Kit-Specification-Sheet.pdf?v=1786490806\" target='_blank\"'\u003eFlood Sensor Connection Kit Specification Sheet\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e\n\u003ch2\u003eView Installation Manuals Here\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-Series-957-957RPDA-LF957RPDA-Installation-Maintenance-and-Repair-Manual.pdf?v=1786490917\" target='_blank\"'\u003e957 Series Installation, Maintenance and Repair Manual\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-BMS-Sensor-Retrofit-Connection-Kit-Installation-Instructions.pdf?v=1786490946\" target='_blank\"'\u003eBMS Sensor Connection Kit Installation Instructions\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-Cellular-Sensor-Retrofit-Connection-Installation-Instructions.pdf?v=1786490950\" target='_blank\"'\u003eCellular Sensor Connection Kit Installation Instructions\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Watts","offers":[{"title":"Default Title","offer_id":44165178261582,"sku":"Watts-LF957-OSY-LM","price":7076.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts_252520LF957RPDA-OSY-LM_252520Backflow_252520Preventer__43279.1756305142.1280.1280.jpg?v=1786656985"},{"product_id":"3-watts-lf957rpda-osy-lm-3-lead-free-stainless-steel-reduced-pressure-detector-backflow-preventer-assembly-osy-gate-valve-shutoff-less-meter","title":"3\" Watts LF957RPDA-OSY-LM 3, Lead-Free Stainless Steel, Reduced Pressure Detector Backflow Preventer Assembly, OSY Gate Valve Shutoff, Less Meter","description":"\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003e3\" Watts LF957RPDA-OSY-LM 3 Reduced Pressure Detector Backflow Preventer Assembly, OSY Gate Valve Shutoff\u003c\/h2\u003e\n\u003ch2\u003eFeatures \u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e304 (Schedule 40) stainless steel housing and sleeve\u003c\/li\u003e\n\u003cli\u003eUL and FM outside stem and yoke resilient seated gate valves\u003c\/li\u003e\n\u003cli\u003eQuick access sleeve\u003c\/li\u003e\n\u003cli\u003eReplaceable check disc rubber\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"column\"\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eItem\u003c\/div\u003e \u003cdiv class=\"right\"\u003eBackflow Preventor\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eSize\u003c\/div\u003e \u003cdiv class=\"right\"\u003e3\"\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eBackflow Preventer Type\u003c\/div\u003e \u003cdiv class=\"right\"\u003eReduced Pressure Detector\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eEnd Connection\u003c\/div\u003e \u003cdiv class=\"right\"\u003eGrooved Joint\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"column\"\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eBody Pattern\u003c\/div\u003e \u003cdiv class=\"right\"\u003eStraight\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eShutoff\u003c\/div\u003e \u003cdiv class=\"right\"\u003eOutside Yoke \u0026amp; Stem Gate Valve\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eTemp. Range\u003c\/div\u003e \u003cdiv class=\"right\"\u003e33°F to 110°F\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eMax. Working Pressure\u003c\/div\u003e \u003cdiv class=\"right\"\u003e175 psi\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv\u003e\n\u003cbr\u003e \u003ch2\u003eView Specification Sheets Here\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-Series-LF957RPDA-Backflow-Preventer-Secification-Sheet.pdf?v=1786490937\" target='_blank\"'\u003e957 Series Specification Sheet\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-SentryPlus-Alert-Flood-Sensor-Connection-Kit-Specification-Sheet.pdf?v=1786490806\" target='_blank\"'\u003eFlood Sensor Connection Kit Specification Sheet\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e\n\u003ch2\u003eView Installation Manuals Here\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-Series-957-957RPDA-LF957RPDA-Installation-Maintenance-and-Repair-Manual.pdf?v=1786490917\" target='_blank\"'\u003e957 Series Installation, Maintenance and Repair Manual\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-BMS-Sensor-Retrofit-Connection-Kit-Installation-Instructions.pdf?v=1786490946\" target='_blank\"'\u003eBMS Sensor Connection Kit Installation Instructions\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-Cellular-Sensor-Retrofit-Connection-Installation-Instructions.pdf?v=1786490950\" target='_blank\"'\u003eCellular Sensor Connection Kit Installation Instructions\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Watts","offers":[{"title":"Default Title","offer_id":44165178589262,"sku":"LF957RPDA-OSY-LM 3","price":7076.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts_252520LF957RPDA-OSY-LM_252520Backflow_252520Preventer__86472.1756305143.1280.1280.jpg?v=1786656987"},{"product_id":"4-watts-lf957rpda-osy-lm-4-lead-free-stainless-steel-reduced-pressure-detector-backflow-preventer-assembly-osy-gate-valve-shutoff-less-meter","title":"4\" Watts LF957RPDA-OSY-LM 4, Lead-Free Stainless Steel, Reduced Pressure Detector Backflow Preventer Assembly, OSY Gate Valve Shutoff, Less Meter","description":"\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003e4\" Watts LF957RPDA-OSY-LM 4 Reduced Pressure Detector Backflow Preventer Assembly, OSY Gate Valve Shutoff\u003c\/h2\u003e\n\u003ch2\u003eFeatures \u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e304 (Schedule 40) stainless steel housing and sleeve\u003c\/li\u003e\n\u003cli\u003eUL and FM outside stem and yoke resilient seated gate valves\u003c\/li\u003e\n\u003cli\u003eQuick access sleeve\u003c\/li\u003e\n\u003cli\u003eReplaceable check disc rubber\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"column\"\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eItem\u003c\/div\u003e \u003cdiv class=\"right\"\u003eBackflow Preventor\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eSize\u003c\/div\u003e \u003cdiv class=\"right\"\u003e4\"\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eBackflow Preventer Type\u003c\/div\u003e \u003cdiv class=\"right\"\u003eReduced Pressure Detector\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eEnd Connection\u003c\/div\u003e \u003cdiv class=\"right\"\u003eGrooved Joint\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"column\"\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eBody Pattern\u003c\/div\u003e \u003cdiv class=\"right\"\u003eStraight\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eShutoff\u003c\/div\u003e \u003cdiv class=\"right\"\u003eOutside Yoke \u0026amp; Stem Gate Valve\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eTemp. Range\u003c\/div\u003e \u003cdiv class=\"right\"\u003e33°F to 110°F\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eMax. Working Pressure\u003c\/div\u003e \u003cdiv class=\"right\"\u003e175 psi\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv\u003e\n\u003cbr\u003e \u003ch2\u003eView Specification Sheets Here\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-Series-LF957RPDA-Backflow-Preventer-Secification-Sheet.pdf?v=1786490937\" target='_blank\"'\u003e957 Series Specification Sheet\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-SentryPlus-Alert-Flood-Sensor-Connection-Kit-Specification-Sheet.pdf?v=1786490806\" target='_blank\"'\u003eFlood Sensor Connection Kit Specification Sheet\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e\n\u003ch2\u003eView Installation Manuals Here\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-Series-957-957RPDA-LF957RPDA-Installation-Maintenance-and-Repair-Manual.pdf?v=1786490917\" target='_blank\"'\u003e957 Series Installation, Maintenance and Repair Manual\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-BMS-Sensor-Retrofit-Connection-Kit-Installation-Instructions.pdf?v=1786490946\" target='_blank\"'\u003eBMS Sensor Connection Kit Installation Instructions\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-Cellular-Sensor-Retrofit-Connection-Installation-Instructions.pdf?v=1786490950\" target='_blank\"'\u003eCellular Sensor Connection Kit Installation Instructions\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Watts","offers":[{"title":"Default Title","offer_id":44165178916942,"sku":"LF957RPDA-OSY-LM 4","price":7870.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts_252520LF957RPDA-OSY-LM_252520Backflow_252520Preventer__40783.1756305143.1280.1280.jpg?v=1786656990"},{"product_id":"6-watts-lf957rpda-osy-lm-6-lead-free-stainless-steel-reduced-pressure-detector-backflow-preventer-assembly-osy-gate-valve-shutoff-less-meter","title":"6\" Watts LF957RPDA-OSY-LM 6, Lead-Free Stainless Steel, Reduced Pressure Detector Backflow Preventer Assembly, OSY Gate Valve Shutoff, Less Meter","description":"\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003e6\" Watts LF957RPDA-OSY-LM 6 Reduced Pressure Detector Backflow Preventer Assembly, OSY Gate Valve Shutoff\u003c\/h2\u003e\n\u003ch2\u003eFeatures \u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e304 (Schedule 40) stainless steel housing and sleeve\u003c\/li\u003e\n\u003cli\u003eUL and FM outside stem and yoke resilient seated gate valves\u003c\/li\u003e\n\u003cli\u003eQuick access sleeve\u003c\/li\u003e\n\u003cli\u003eReplaceable check disc rubber\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"column\"\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eItem\u003c\/div\u003e \u003cdiv class=\"right\"\u003eBackflow Preventor\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eSize\u003c\/div\u003e \u003cdiv class=\"right\"\u003e6\"\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eBackflow Preventer Type\u003c\/div\u003e \u003cdiv class=\"right\"\u003eReduced Pressure Detector\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eEnd Connection\u003c\/div\u003e \u003cdiv class=\"right\"\u003eGrooved Joint\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"column\"\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eBody Pattern\u003c\/div\u003e \u003cdiv class=\"right\"\u003eStraight\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eShutoff\u003c\/div\u003e \u003cdiv class=\"right\"\u003eOutside Yoke \u0026amp; Stem Gate Valve\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eTemp. Range\u003c\/div\u003e \u003cdiv class=\"right\"\u003e33°F to 110°F\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eMax. Working Pressure\u003c\/div\u003e \u003cdiv class=\"right\"\u003e175 psi\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv\u003e\n\u003cbr\u003e \u003ch2\u003eView Specification Sheets Here\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-Series-LF957RPDA-Backflow-Preventer-Secification-Sheet.pdf?v=1786490937\" target='_blank\"'\u003e957 Series Specification Sheet\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-SentryPlus-Alert-Flood-Sensor-Connection-Kit-Specification-Sheet.pdf?v=1786490806\" target='_blank\"'\u003eFlood Sensor Connection Kit Specification Sheet\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e\n\u003ch2\u003eView Installation Manuals Here\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-Series-957-957RPDA-LF957RPDA-Installation-Maintenance-and-Repair-Manual.pdf?v=1786490917\" target='_blank\"'\u003e957 Series Installation, Maintenance and Repair Manual\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-BMS-Sensor-Retrofit-Connection-Kit-Installation-Instructions.pdf?v=1786490946\" target='_blank\"'\u003eBMS Sensor Connection Kit Installation Instructions\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-Cellular-Sensor-Retrofit-Connection-Installation-Instructions.pdf?v=1786490950\" target='_blank\"'\u003eCellular Sensor Connection Kit Installation Instructions\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Watts","offers":[{"title":"Default Title","offer_id":44165179244622,"sku":"LF957RPDA-OSY-LM 6","price":11306.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts_252520LF957RPDA-OSY-LM_252520Backflow_252520Preventer__19594.1756305143.1280.1280.jpg?v=1786656992"},{"product_id":"8-watts-lf957rpda-osy-lm-fs-8-lead-free-stainless-steel-reduced-pressure-detector-backflow-preventer-assembly-osy-gate-valve-shutoff-less-meter","title":"8\" Watts LF957RPDA-OSY-LM-FS 8, Lead-Free Stainless Steel, Reduced Pressure Detector Backflow Preventer Assembly, OSY Gate Valve Shutoff, Less Meter","description":"\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003e8\" Watts LF957RPDA-OSY-LM-FS 8 Reduced Pressure Detector Backflow Preventer Assembly, OSY Gate Valve Shutoff\u003c\/h2\u003e\n\u003ch2\u003eFeatures \u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e304 (Schedule 40) stainless steel housing and sleeve\u003c\/li\u003e\n\u003cli\u003eUL and FM outside stem and yoke resilient seated gate valves\u003c\/li\u003e\n\u003cli\u003eQuick access sleeve\u003c\/li\u003e\n\u003cli\u003eReplaceable check disc rubber\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"column\"\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eItem\u003c\/div\u003e \u003cdiv class=\"right\"\u003eBackflow Preventor\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eSize\u003c\/div\u003e \u003cdiv class=\"right\"\u003e8\"\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eBackflow Preventer Type\u003c\/div\u003e \u003cdiv class=\"right\"\u003eReduced Pressure Detector\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eEnd Connection\u003c\/div\u003e \u003cdiv class=\"right\"\u003eGrooved Joint\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"column\"\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eBody Pattern\u003c\/div\u003e \u003cdiv class=\"right\"\u003eStraight\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eShutoff\u003c\/div\u003e \u003cdiv class=\"right\"\u003eOutside Yoke \u0026amp; Stem Gate Valve\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eTemp. Range\u003c\/div\u003e \u003cdiv class=\"right\"\u003e33°F to 110°F\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eMax. Working Pressure\u003c\/div\u003e \u003cdiv class=\"right\"\u003e175 psi\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv\u003e\n\u003cbr\u003e \u003ch2\u003eView Specification Sheets Here\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-Series-LF957RPDA-Backflow-Preventer-Secification-Sheet.pdf?v=1786490937\" target='_blank\"'\u003e957 Series Specification Sheet\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-SentryPlus-Alert-Flood-Sensor-Connection-Kit-Specification-Sheet.pdf?v=1786490806\" target='_blank\"'\u003eFlood Sensor Connection Kit Specification Sheet\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e\n\u003ch2\u003eView Installation Manuals Here\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-Series-957-957RPDA-LF957RPDA-Installation-Maintenance-and-Repair-Manual.pdf?v=1786490917\" target='_blank\"'\u003e957 Series Installation, Maintenance and Repair Manual\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-BMS-Sensor-Retrofit-Connection-Kit-Installation-Instructions.pdf?v=1786490946\" target='_blank\"'\u003eBMS Sensor Connection Kit Installation Instructions\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts-Cellular-Sensor-Retrofit-Connection-Installation-Instructions.pdf?v=1786490950\" target='_blank\"'\u003eCellular Sensor Connection Kit Installation Instructions\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Watts","offers":[{"title":"Default Title","offer_id":44165179539534,"sku":"LF957RPDA-OSY-LM-FS 8","price":20141.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watts_252520LF957RPDA-OSY-LM_252520Backflow_252520Preventer__06409.1756305144.1280.1280.jpg?v=1786656995"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/collections\/Watts_252520LF957RPDAOSY-GPM-FS_252520Backflow_252520Preventer_2525201__03461.1756305138.1280.1280.jpg?v=1787607679","url":"https:\/\/valveman.com\/collections\/reduced-pressure-detector-assemblies.oembed","provider":"ValveMan","version":"1.0","type":"link"}