{"title":"Ultrasonic Flow Meters","description":"\u003cp\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@graph\": [\n    {\n      \"@type\": \"CollectionPage\",\n      \"@id\": \"https:\/\/valveman.com\/ultrasonic-flowmeter\/#collectionpage\",\n      \"url\": \"https:\/\/valveman.com\/ultrasonic-flowmeter\/\",\n      \"name\": \"Ultrasonic Flow Meters: Clamp-On, Inline \u0026 Portable | ValveMan\",\n      \"description\": \"Shop clamp-on and inline ultrasonic flow meters. Our guide helps you choose between Doppler and transit time for your application. Get expert help at ValveMan.\",\n      \"isPartOf\": {\n        \"@id\": \"https:\/\/valveman.com\/#website\"\n      },\n      \"breadcrumb\": {\n        \"@id\": \"https:\/\/valveman.com\/ultrasonic-flowmeter\/#breadcrumb\"\n      },\n      \"mainEntity\": {\n        \"@id\": \"https:\/\/valveman.com\/ultrasonic-flowmeter\/#faq\"\n      },\n      \"publisher\": {\n        \"@type\": \"Organization\",\n        \"name\": \"ValveMan\",\n        \"url\": \"https:\/\/valveman.com\/\",\n        \"logo\": {\n          \"@type\": \"ImageObject\",\n          \"url\": \"https:\/\/cdn11.bigcommerce.com\/s-plss3w\/images\/stencil\/250x100\/valveman_logo_1611168313__96123.original.png\"\n        }\n      }\n    },\n    {\n      \"@type\": \"BreadcrumbList\",\n      \"@id\": \"https:\/\/valveman.com\/ultrasonic-flowmeter\/#breadcrumb\",\n      \"itemListElement\": [\n        {\n          \"@type\": \"ListItem\",\n          \"position\": 1,\n          \"name\": \"Home\",\n          \"item\": \"https:\/\/valveman.com\/\"\n        },\n        {\n          \"@type\": \"ListItem\",\n          \"position\": 2,\n          \"name\": \"Instrumentation\",\n          \"item\": \"https:\/\/valveman.com\/instrumentation\/\"\n        },\n        {\n          \"@type\": \"ListItem\",\n          \"position\": 3,\n          \"name\": \"Flow Meters\",\n          \"item\": \"https:\/\/valveman.com\/flow-meters\/\"\n        },\n        {\n          \"@type\": \"ListItem\",\n          \"position\": 4,\n          \"name\": \"Ultrasonic Flow Meters\",\n          \"item\": \"https:\/\/valveman.com\/ultrasonic-flowmeter\/\"\n        }\n      ]\n    },\n    {\n      \"@type\": \"FAQPage\",\n      \"@id\": \"https:\/\/valveman.com\/ultrasonic-flowmeter\/#faq\",\n      \"mainEntity\": [\n        {\n          \"@type\": \"Question\",\n          \"name\": \"What is the main difference between Doppler and transit time ultrasonic flow meters?\",\n          \"acceptedAnswer\": {\n            \"@type\": \"Answer\",\n            \"text\": \"The main difference is the type of liquid they are designed for. Transit time meters work best with clean liquids, measuring the time difference of signals traveling with and against the flow. Doppler meters are designed for dirty or aerated liquids, measuring the frequency shift of signals bouncing off particles or bubbles in the fluid.\"\n          }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"Can a clamp-on meter be as accurate as an inline meter?\",\n          \"acceptedAnswer\": {\n            \"@type\": \"Answer\",\n            \"text\": \"While clamp-on meters are highly accurate, a permanently installed inline meter will typically offer higher accuracy and repeatability. This is because inline meters are factory-calibrated and have a fixed, known path for the ultrasonic signal, eliminating variables like pipe wall thickness and transducer alignment.\"\n          }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"What is flow profile and why does it matter?\",\n          \"acceptedAnswer\": {\n            \"@type\": \"Answer\",\n            \"text\": \"Flow profile refers to the way the fluid moves through the pipe. An ideal, or fully developed, flow profile is uniform and is essential for accurate measurement. This is why ultrasonic meters should be installed with long, straight pipe runs upstream and downstream, away from disturbances like elbows, valves, or pumps that can disrupt the flow profile.\"\n          }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"Do I need to know my pipe's material and wall thickness for a clamp-on ultrasonic flow meter?\",\n          \"acceptedAnswer\": {\n            \"@type\": \"Answer\",\n            \"text\": \"Yes, for clamp-on meters, this information is critical. The meter's setup requires you to input the pipe's outer diameter, wall thickness, and material such as carbon steel, PVC, or copper. The meter uses this data to calculate the exact path and speed of the ultrasonic signal through the pipe wall and into the liquid.\"\n          }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"Can ultrasonic flow meters measure the flow of gases?\",\n          \"acceptedAnswer\": {\n            \"@type\": \"Answer\",\n            \"text\": \"While the technology is similar, ultrasonic meters designed for liquids are not typically suitable for measuring gases. Gas flow measurement requires specialized ultrasonic meters that are calibrated for the unique acoustic properties of gases, which are much different from liquids.\"\n          }\n        }\n      ]\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/p\u003e\n\n\n\u003cdiv style=\"width: 100%; overflow-x: auto; margin: 30px 0;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; min-width: 500px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eTypical Use\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eWater Management\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\n\u003cp\u003eLeak detection and pump performance testing.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eHVAC\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\n\u003cp\u003eMeasuring BTU or energy usage in chilled water loops (together with temperature sensors).\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eFood \u0026amp; Beverage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\n\u003cp\u003eMeasuring liquid flows in a non-intrusive manner, where hygiene is critical.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\n\u003cp\u003e\u003cstrong\u003ePower Plants\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\n\u003cp\u003eMonitoring cooling water flow in massive pipes.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThere are two ways ultrasonic flow meters calculate flow, and that’s our next topic.\u003c\/p\u003e\n\u003ch2\u003eHow Ultrasonic Flow Meters Work\u003c\/h2\u003e\n\u003cp\u003eThere are two primary methods ultrasonic flow meters use to calculate flow: Transit Time and Doppler Effect.\u003c\/p\u003e\n\u003cp\u003eTransit Time: The most common method, based on ultrasonic transit time. In this approach, two transducers are mounted on a pipe, one upstream and one downstream. The transducers send ultrasonic pulses back and forth through the fluid. Sound traveling in the direction of flow reaches the receiving transducer a little faster than sound traveling against the flow. The meter measures this extremely small time difference. From that, the meter can calculate fluid velocity. Transit time ultrasonic flow meters work best with clean or lightly contaminated liquids.\u003c\/p\u003e\n\u003cp\u003eDoppler Effect: The second approach works best for dirty liquids (i.e., slurries, raw sewage) or aerated liquids that have been filled with air bubbles. This method depends wholly on the Doppler effect. When this method is used, a flow meter transducer sends a sound wave into the pipe. This wave either hits (a) solid particles or (b) bubbles moving in the liquid. When the sound wave bounces back, the frequency of the sound changes depending on how fast those particles are moving. The meter measures this frequency shift to calculate the flow speed.\u003c\/p\u003e\n\u003ch2\u003eInline vs. Clamp-On Ultrasonic Flow Meters\u003c\/h2\u003e\n\u003cp\u003eInline flow meters have transducers directly integrated into the meter body (referred to as wetted sensors). This provides a fixed acoustic path for higher accuracy and long-term stability. They are the best choice when precision is critical, such as for billing or chemical dosing.\u003c\/p\u003e\n\u003cp\u003eClamp-on flow meters use transducers that mount to the outside of the pipe. This non-invasive approach is ideal for retrofitting, temporary measurements, or situations where downtime must be minimized. A good example is the \u003ca href=\"\/tek-trol-tek-clamp-1200a-100-series-ultrasonic-flow-meter\/\"\u003eTek-Trol Tek-Clamp 1200A-100 Series Ultrasonic Flow Meter\u003c\/a\u003e.\u003c\/p\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto; margin: 10px 0;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 30px 0; min-width: 700px; font-family: inherit;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 12px; border-bottom: 1px solid #ddd;\"\u003eFeature\u003c\/th\u003e\n\u003cth style=\"text-align: left; padding: 12px; border-bottom: 1px solid #ddd;\"\u003eInline Ultrasonic Flow Meter\u003c\/th\u003e\n\u003cth style=\"text-align: left; padding: 12px; border-bottom: 1px solid #ddd;\"\u003eClamp-On Ultrasonic Flow Meter\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border-bottom: 1px solid #eee;\"\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border-bottom: 1px solid #eee;\"\u003eRequires cutting the pipe; more complex\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border-bottom: 1px solid #eee;\"\u003eStraps to the outside of the pipe; simple\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border-bottom: 1px solid #eee;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border-bottom: 1px solid #eee;\"\u003eHigher, factory calibrated\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border-bottom: 1px solid #eee;\"\u003eGood, depends on setup and pipe conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border-bottom: 1px solid #eee;\"\u003e\u003cstrong\u003eMaintenance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border-bottom: 1px solid #eee;\"\u003eLow; no moving parts\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border-bottom: 1px solid #eee;\"\u003eVery low; transducers are external\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border-bottom: 1px solid #eee;\"\u003e\u003cstrong\u003eCost\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border-bottom: 1px solid #eee;\"\u003eHigher initial cost\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border-bottom: 1px solid #eee;\"\u003eLower initial cost\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border-bottom: 1px solid #eee;\"\u003e\u003cstrong\u003eBest For\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border-bottom: 1px solid #eee;\"\u003eCustody transfer, critical processes\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border-bottom: 1px solid #eee;\"\u003eRetrofits, system audits, temporary use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/inline-vs-clamp-on-ultrasonic-flow-meters.png?v=1786042280\" alt=\"\" width=\"247\" height=\"372\"\u003e\u003c\/p\u003e\n\u003cp\u003eIn short, inline meters are chosen when accuracy and permanent metering are necessary, and clamp-on meters (including portable ultrasonic flow meters) are used when there is a need for flexibility and easy installation.\u003cspan style=\"font-weight: 400;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto; margin: 10px 0;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; min-width: 600px; margin: 30px 0;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eClamp-On\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eInline (Wetted)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eInvasive?\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eNo\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eMinutes (while running)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eHours (system shutdown)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eBest For\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eAudits, retrofitting, corrosive fluids\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eHigh-precision billing, new builds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003eTransit Time vs Doppler Effect Flow Meters\u003c\/h2\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto; margin: 10px 0;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; min-width: 700px; margin: 30px 0;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eTransit Time Ultrasonic Flow Meters\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eDoppler Ultrasonic Flow Meters\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eMeasurement Principle\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eMeasures the time difference between ultrasonic pulses traveling with and against the flow\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eMeasures the frequency shift of ultrasonic waves reflected from particles or gas bubbles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eRequired Fluid Condition\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eClean or lightly contaminated liquids\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eLiquids containing suspended solids or entrained gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003ePresence of Solids \/ Bubbles\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eMinimal to none; excessive solids or bubbles degrade accuracy\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eRequired; without reflectors, the meter cannot function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eTypical Applications\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eWater distribution, chemical processing, oils, hydrocarbons, ultrapure fluids\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eWastewater, sludge, slurry, aerated liquids\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eHigh (±0.5–1% of reading)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eModerate (±2–5% of reading)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eSensitivity to Flow Profile\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eModerate; long straight pipe runs improve accuracy\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eLower sensitivity due to reliance on reflected signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003ePipe Size Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eWide; suitable for small to very large diameter pipes\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eBest suited for medium to large diameter pipes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eInstallation Method\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eClamp-on or inline\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eClamp-on or inline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eEffect of Fluid Properties\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eAffected by temperature, density, and sound velocity\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eDependent on particle concentration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eMaintenance Requirements\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eLow; no moving parts\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eLow; depends on stable solids\/gas content\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eBest Use Case\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eHigh-accuracy measurement in clean systems\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eBest for dirty or aerated systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003eKey Advantages of Ultrasonic Flow Meters\u003c\/h2\u003e\n\u003cp\u003eLet’s look at some of the advantages of the different ultrasonic flow meters.\u003c\/p\u003e\n\u003ch3\u003eBenefits of the Clamp-On Approach:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Invasive:\u003c\/strong\u003e No need to cut pipes, weld flanges, or shut down your process.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo Pressure Drop: \u003c\/strong\u003eNo components inside the pipe to obstruct flow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZero Risk of Leaks or Contamination:\u003c\/strong\u003e No seals to fail.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Portability:\u003c\/strong\u003e A single portable meter can be used to audit multiple pipe locations in a single day.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eBenefits of the Inline Approach:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Accuracy:\u003c\/strong\u003e Factory-calibrated for the highest precision.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuperior Signal Strength:\u003c\/strong\u003e Transducers are in direct contact with the fluid.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong-Term Reliability:\u003c\/strong\u003e Permanently installed and less prone to issues like coupling gel dry-out.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIdeal for Billing:\u003c\/strong\u003e Hard-wired and harder to tamper with, making them suitable for custody transfer applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhich one is right for you?\u003c\/h3\u003e\n\u003cp\u003eWell, if you are doing an energy audit, adding a meter to an existing line that can't be shut down, or working with highly corrosive acids, then choose a clamp-on. And keep in mind that portable ultrasonic meters are available as clamp-on flow meters that can be moved from pipe to pipe.\u003c\/p\u003e\n\u003cp\u003eOn the other hand, if you are designing a brand-new system that requires the absolute highest precision for billing or critical chemical dosing, then go with an inline ultrasonic flow meters solution.\u003c\/p\u003e\n\u003ch2\u003eLimitations of Ultrasonic Flow Meters\u003c\/h2\u003e\n\u003cp\u003eThere are limitations to ultrasonic flow meters, and some rare conditions that must be met in order for the meters to accurately measure flow.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli aria-level=\"1\"\u003e\n\u003cstrong\u003eFull Pipes Only:\u003c\/strong\u003e The pipe must be completely full of liquid. If there is an air pocket at the top, the sound wave will scatter, and the meter will fail. Pro-Tip: Installing the meter on a vertical pipe with upward flow is a good way to ensure full-pipe flow.\u003c\/li\u003e\n\u003cli aria-level=\"1\"\u003e\n\u003cstrong\u003eStraight Run Requirements:\u003c\/strong\u003e To get a steady reading, you usually need a straight section of pipe (roughly 10 times the pipe diameter) before the meter to ensure the flow isn't turbulent from an elbow or valve.\u003c\/li\u003e\n\u003cli aria-level=\"1\"\u003e\n\u003cstrong\u003ePipe Material:\u003c\/strong\u003e They work best on metal or plastic pipes. Materials like concrete or cement-lined pipes can sometimes absorb the sound signal, making measurement difficult.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca style=\"display: inline-block; background: #1b75bc; color: #fff; padding: 12px 20px; text-decoration: none; border-radius: 4px; font-weight: bold;\" href=\"\/pages\/contact\" target=\"_blank\" rel=\"noopener\"\u003e Chat With An Engineer\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eFAQs for Ultrasonic Flow Meters\u003c\/h2\u003e\n\u003ch3\u003e1. What is the main difference between Doppler and transit time ultrasonic flow meters?\u003c\/h3\u003e\n\u003cp\u003eThe main difference is the type of liquid they are designed for. Transit time meters work best with clean liquids, measuring the time difference of signals traveling with and against the flow. Doppler meters are designed for dirty or aerated liquids, measuring the frequency shift of signals bouncing off particles or bubbles in the fluid.\u003c\/p\u003e\n\u003ch3\u003e2. Can a clamp-on meter be as accurate as an inline meter?\u003c\/h3\u003e\n\u003cp\u003eWhile clamp-on meters are highly accurate, a permanently installed inline meter will typically offer higher accuracy and repeatability. This is because inline meters are factory-calibrated and have a fixed, known path for the ultrasonic signal, eliminating variables like pipe wall thickness and transducer alignment.\u003c\/p\u003e\n\u003ch3\u003e3. What is “flow profile” and why does it matter?\u003c\/h3\u003e\n\u003cp\u003eFlow profile refers to the way the fluid moves through the pipe. An ideal, or “fully developed,” flow profile is uniform and is essential for accurate measurement. This is why ultrasonic meters should be installed with long, straight pipe runs upstream and downstream, away from disturbances like elbows, valves, or pumps that can disrupt the flow profile.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e4. Do I need to know my pipe’s material and wall thickness?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eYes, for clamp-on meters, this information is critical. The meter’s setup requires you to input the pipe’s outer diameter, wall thickness, and material (e.g., carbon steel, PVC, copper). The meter uses this data to calculate the exact path and speed of the ultrasonic signal through the pipe wall and into the liquid.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e5. Can ultrasonic meters measure the flow of gases? \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eWhile the technology is similar, ultrasonic meters designed for liquids are not typically suitable for measuring gases. Gas flow measurement requires specialized ultrasonic meters that are calibrated for the unique acoustic properties of gases, which are much different from liquids.\u003c\/p\u003e\n\u003ch2\u003eYour Partner for Ultrasonic Flow Meters\u003c\/h2\u003e\n\u003cp\u003eWhether you need an inline ultrasonic flow meters for monitoring the flow of water for billing or a clamp-on flow meter for energy audits, our application engineers are standing by to help you find the right solution. Experts are standing by to help you evaluate your operation and choose the right type of flow. If you need an expert to confirm your selection or have a complex application, we are ready to help.\u003c\/p\u003e","products":[{"product_id":"tek-trol-tek-clamp-1200a-series-ultrasonic-transducers","title":"Tek-Trol Tek-Clamp 1200A Series Ultrasonic Transducers","description":"\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTek-Trol Tek-Clamp 1200A Series Ultrasonic Transducers\u003c\/h2\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBetter than ±1.0% accuracy\u003c\/li\u003e\n\u003cli\u003ePipe diameters from 1\/2\" to 28\"\u003c\/li\u003e\n\u003cli\u003eProtection class: IP65 (Tek-Clamp 1200A-100F1) ,IP57 (Tek-Clamp 1200A-100M)\u003c\/li\u003e\n\u003cli\u003e4 x 4 key tactile-feedback membrane keypad\u003c\/li\u003e\n\u003cli\u003ePower supply AC 85-264 V or isolation DC 8-36 VDC\u003c\/li\u003e\n\u003cli\u003eLCD with backlight 2 x 20 letters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eItem\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003eUltrasonic Transducers\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eType\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003eWall and DIN Controller \/ Hand Held \/ Bracket Mounted Sensors (Hand Held)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eProtection Class\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003eIP65 (Tek-Clamp 1200A-100F1)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePipe Material\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003eAll metals ,most plastics, fiber glass, etc\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\n\u003ch3\u003eDiscover more about the Tek-Trol Tek-Clamp 1200A Series Ultrasonic Transducers\u003c\/h3\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A_Ultrasonic_Catalog.pdf?v=1789103269\"\u003eCatalog\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A_Ultrasonic_Manual_ff010e8f-c478-4197-a4bd-fe3b08a9716d.pdf?v=1789103275\"\u003eManual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A_Ultrasonic_QSG.pdf?v=1789103281\"\u003eQuick Start Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A-Ultrasonic-Clamp-on-Flowmeter-Datasheet_e7b1cfa0-f6c6-4420-9c4c-c85bacc2dbd8.pdf?v=1789103286\"\u003eDatasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A_ClampOn_ModbusManual.pdf?v=1789103291\"\u003eModbus Map\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A-Water_industry_brochure_en21.r00_W.pdf?v=1789103296\"\u003eWater Industry Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A-OilAndGas_Brochure.pdf?v=1789103301\"\u003eOil and Gas Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eVideos\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=X_wVKDL19GA\u0026amp;t=43s\"\u003eTek-Clamp 1200A Ultrasonic Flow Meter\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=3hE3i6ooxyU\"\u003eTek Clamp 1200A Ultrasonic Clamp On Setup\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=F9tXuQttNGU\"\u003e Tek-Clamp 1200A Ultrasonic Clamp On Flow Meter Flow unit setup\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Tek-Trol","offers":[{"title":"Default Title","offer_id":44163307176014,"sku":"TKTRL-Tek-Clamp 1200A","price":477.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A-Transducers-Image-1.jpg?v=1791569692"},{"product_id":"tek-trol-tek-clamp-1200a-s2-ultrasonic-transducers-1-2-to-4-pipe-wall-and-din-controller","title":"Tek-Trol Tek-Clamp 1200A-S2 Ultrasonic Transducer Pair for Wall Mount \u0026 DIN Flow Meters, 1\/2\" to 4\" Pipe","description":"\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTek-Trol Tek-Clamp 1200A-S2 Ultrasonic Transducer Pair for Wall Mount \u0026amp; DIN Flow Meters, 1\/2\" to 4\" Pipe\u003c\/h2\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBetter than ±1.0% accuracy\u003c\/li\u003e\n\u003cli\u003ePipe diameters from 1\/2\" to 28\"\u003c\/li\u003e\n\u003cli\u003eProtection class: IP65 (Tek-Clamp 1200A-100F1) ,IP57 (Tek-Clamp 1200A-100M)\u003c\/li\u003e\n\u003cli\u003e4 x 4 key tactile-feedback membrane keypad\u003c\/li\u003e\n\u003cli\u003ePower supply AC 85-264 V or isolation DC 8-36 VDC\u003c\/li\u003e\n\u003cli\u003eLCD with backlight 2 x 20 letters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eItem\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003eUltrasonic Transducers\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eType\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003eWall and DIN Controller\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eProtection Class\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003eIP65 (Tek-Clamp 1200A-100F1)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePipe Material\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003eAll metals ,most plastics, fiber glass, etc\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\n\u003ch3\u003eDiscover more about the Tek-Trol Tek-Clamp 1200A Series Ultrasonic Transducers\u003c\/h3\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A_Ultrasonic_Catalog.pdf?v=1789103269\"\u003eCatalog\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A_Ultrasonic_Manual_ff010e8f-c478-4197-a4bd-fe3b08a9716d.pdf?v=1789103275\"\u003eManual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A_Ultrasonic_QSG.pdf?v=1789103281\"\u003eQuick Start Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A-Ultrasonic-Clamp-on-Flowmeter-Datasheet_e7b1cfa0-f6c6-4420-9c4c-c85bacc2dbd8.pdf?v=1789103286\"\u003eDatasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A_ClampOn_ModbusManual.pdf?v=1789103291\"\u003eModbus Map\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A-Water_industry_brochure_en21.r00_W.pdf?v=1789103296\"\u003eWater Industry Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A-OilAndGas_Brochure.pdf?v=1789103301\"\u003eOil and Gas Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eVideos\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=X_wVKDL19GA\u0026amp;t=43s\"\u003eTek-Clamp 1200A Ultrasonic Flow Meter\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=3hE3i6ooxyU\"\u003eTek Clamp 1200A Ultrasonic Clamp On Setup\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=F9tXuQttNGU\"\u003e Tek-Clamp 1200A Ultrasonic Clamp On Flow Meter Flow unit setup\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Tek-Trol","offers":[{"title":"Default Title","offer_id":44163307307086,"sku":"Tek-Clamp 1200A-S2","price":477.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A-Transducers-Image-1.jpg?v=1791569692"},{"product_id":"tek-trol-tek-clamp-1200a-m2-ultrasonic-transducers-2-to-28-pipe-wall-and-din-controller","title":"Tek-Trol Tek-Clamp 1200A-M2 Ultrasonic Transducer Pair for Wall Mount \u0026 DIN Flow Meters, 2\" to 28\" Pipe","description":"\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTek-Trol Tek-Clamp 1200A-M2 Ultrasonic Transducer Pair for Wall Mount \u0026amp; DIN Flow Meters, 2\" to 28\" Pipe\u003c\/h2\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBetter than ±1.0% accuracy\u003c\/li\u003e\n\u003cli\u003ePipe diameters from 1\/2\" to 28\"\u003c\/li\u003e\n\u003cli\u003eProtection class: IP65 (Tek-Clamp 1200A-100F1) ,IP57 (Tek-Clamp 1200A-100M)\u003c\/li\u003e\n\u003cli\u003e4 x 4 key tactile-feedback membrane keypad\u003c\/li\u003e\n\u003cli\u003ePower supply AC 85-264 V or isolation DC 8-36 VDC\u003c\/li\u003e\n\u003cli\u003eLCD with backlight 2 x 20 letters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eItem\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003eUltrasonic Transducers\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eType\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003eWall and DIN Controller\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eProtection Class\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003eIP65 (Tek-Clamp 1200A-100F1)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePipe Material\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003eAll metals ,most plastics, fiber glass, etc\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\n\u003ch3\u003eDiscover more about the Tek-Trol Tek-Clamp 1200A Series Ultrasonic Transducers\u003c\/h3\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A_Ultrasonic_Catalog.pdf?v=1789103269\"\u003eCatalog\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A_Ultrasonic_Manual_ff010e8f-c478-4197-a4bd-fe3b08a9716d.pdf?v=1789103275\"\u003eManual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A_Ultrasonic_QSG.pdf?v=1789103281\"\u003eQuick Start Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A-Ultrasonic-Clamp-on-Flowmeter-Datasheet_e7b1cfa0-f6c6-4420-9c4c-c85bacc2dbd8.pdf?v=1789103286\"\u003eDatasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A_ClampOn_ModbusManual.pdf?v=1789103291\"\u003eModbus Map\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A-Water_industry_brochure_en21.r00_W.pdf?v=1789103296\"\u003eWater Industry Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A-OilAndGas_Brochure.pdf?v=1789103301\"\u003eOil and Gas Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eVideos\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=X_wVKDL19GA\u0026amp;t=43s\"\u003eTek-Clamp 1200A Ultrasonic Flow Meter\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=3hE3i6ooxyU\"\u003eTek Clamp 1200A Ultrasonic Clamp On Setup\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=F9tXuQttNGU\"\u003e Tek-Clamp 1200A Ultrasonic Clamp On Flow Meter Flow unit setup\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Tek-Trol","offers":[{"title":"Default Title","offer_id":44163307438158,"sku":"Tek-Clamp 1200A-M2","price":504.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A-Transducers-Image-1.jpg?v=1791569692"},{"product_id":"tek-trol-tek-clamp-1200a-s2h-ultrasonic-transducers-1-2-to-4-pipe-hand-held","title":"Tek-Trol Tek-Clamp 1200A-S2H Ultrasonic Transducer Pair for Hand Held Flow Meter, 1\/2\" to 4\" Pipe","description":"\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTek-Trol Tek-Clamp 1200A-S2H Ultrasonic Transducer Pair for Hand Held Flow Meter, 1\/2\" to 4\" Pipe\u003c\/h2\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBetter than ±1.0% accuracy\u003c\/li\u003e\n\u003cli\u003ePipe diameters from 1\/2\" to 28\"\u003c\/li\u003e\n\u003cli\u003eProtection class: IP65 (Tek-Clamp 1200A-100F1) ,IP57 (Tek-Clamp 1200A-100M)\u003c\/li\u003e\n\u003cli\u003e4 x 4 key tactile-feedback membrane keypad\u003c\/li\u003e\n\u003cli\u003ePower supply AC 85-264 V or isolation DC 8-36 VDC\u003c\/li\u003e\n\u003cli\u003eLCD with backlight 2 x 20 letters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eItem\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003eUltrasonic Transducers\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eType\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003eHand Held\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eProtection Class\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003eIP65 (Tek-Clamp 1200A-100F1)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePipe Material\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003eAll metals ,most plastics, fiber glass, etc\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\n\u003ch3\u003eDiscover more about the Tek-Trol Tek-Clamp 1200A Series Ultrasonic Transducers\u003c\/h3\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A_Ultrasonic_Catalog.pdf?v=1789103269\"\u003eCatalog\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A_Ultrasonic_Manual_ff010e8f-c478-4197-a4bd-fe3b08a9716d.pdf?v=1789103275\"\u003eManual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A_Ultrasonic_QSG.pdf?v=1789103281\"\u003eQuick Start Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A-Ultrasonic-Clamp-on-Flowmeter-Datasheet_e7b1cfa0-f6c6-4420-9c4c-c85bacc2dbd8.pdf?v=1789103286\"\u003eDatasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A_ClampOn_ModbusManual.pdf?v=1789103291\"\u003eModbus Map\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A-Water_industry_brochure_en21.r00_W.pdf?v=1789103296\"\u003eWater Industry Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A-OilAndGas_Brochure.pdf?v=1789103301\"\u003eOil and Gas Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eVideos\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=X_wVKDL19GA\u0026amp;t=43s\"\u003eTek-Clamp 1200A Ultrasonic Flow Meter\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=3hE3i6ooxyU\"\u003eTek Clamp 1200A Ultrasonic Clamp On Setup\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=F9tXuQttNGU\"\u003e Tek-Clamp 1200A Ultrasonic Clamp On Flow Meter Flow unit setup\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Tek-Trol","offers":[{"title":"Default Title","offer_id":44163307601998,"sku":"Tek-Clamp 1200A-S2H","price":477.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A-Transducers-Image-1.jpg?v=1791569692"},{"product_id":"tek-trol-tek-clamp-1200a-m2h-ultrasonic-transducers-2-to-28-pipe-hand-held","title":"Tek-Trol Tek-Clamp 1200A-M2H Ultrasonic Transducer Pair for Hand Held Flow Meter, 2\" to 28\" Pipe","description":"\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTek-Trol Tek-Clamp 1200A-M2H Ultrasonic Transducer Pair for Hand Held Flow Meter, 2\" to 28\" Pipe\u003c\/h2\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBetter than ±1.0% accuracy\u003c\/li\u003e\n\u003cli\u003ePipe diameters from 1\/2\" to 28\"\u003c\/li\u003e\n\u003cli\u003eProtection class: IP65 (Tek-Clamp 1200A-100F1) ,IP57 (Tek-Clamp 1200A-100M)\u003c\/li\u003e\n\u003cli\u003e4 x 4 key tactile-feedback membrane keypad\u003c\/li\u003e\n\u003cli\u003ePower supply AC 85-264 V or isolation DC 8-36 VDC\u003c\/li\u003e\n\u003cli\u003eLCD with backlight 2 x 20 letters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eItem\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003eUltrasonic Transducers\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eType\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003eHand Held\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eProtection Class\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003eIP65 (Tek-Clamp 1200A-100F1)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePipe Material\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003eAll metals ,most plastics, fiber glass, etc\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\n\u003ch3\u003eDiscover more about the Tek-Trol Tek-Clamp 1200A Series Ultrasonic Transducers\u003c\/h3\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A_Ultrasonic_Catalog.pdf?v=1789103269\"\u003eCatalog\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A_Ultrasonic_Manual_ff010e8f-c478-4197-a4bd-fe3b08a9716d.pdf?v=1789103275\"\u003eManual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A_Ultrasonic_QSG.pdf?v=1789103281\"\u003eQuick Start Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A-Ultrasonic-Clamp-on-Flowmeter-Datasheet_e7b1cfa0-f6c6-4420-9c4c-c85bacc2dbd8.pdf?v=1789103286\"\u003eDatasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A_ClampOn_ModbusManual.pdf?v=1789103291\"\u003eModbus Map\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A-Water_industry_brochure_en21.r00_W.pdf?v=1789103296\"\u003eWater Industry Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A-OilAndGas_Brochure.pdf?v=1789103301\"\u003eOil and Gas Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eVideos\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=X_wVKDL19GA\u0026amp;t=43s\"\u003eTek-Clamp 1200A Ultrasonic Flow Meter\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=3hE3i6ooxyU\"\u003eTek Clamp 1200A Ultrasonic Clamp On Setup\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=F9tXuQttNGU\"\u003e Tek-Clamp 1200A Ultrasonic Clamp On Flow Meter Flow unit setup\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Tek-Trol","offers":[{"title":"Default Title","offer_id":44163307700302,"sku":"Tek-Clamp 1200A-M2H","price":504.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A-Transducers-Image-1.jpg?v=1791569692"},{"product_id":"tek-trol-tek-clamp-1200a-hsh-ultrasonic-transducers-1-2-to-4-pipe-bracket-mounted-sensors-hand-held","title":"Tek-Trol Tek-Clamp 1200A-HSH Bracket-Mounted Ultrasonic Transducer Pair for Hand Held Flow Meter, 1\/2\" to 4\" Pipe","description":"\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTek-Trol Tek-Clamp 1200A-HSH Bracket-Mounted Ultrasonic Transducer Pair for Hand Held Flow Meter, 1\/2\" to 4\" Pipe\u003c\/h2\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBetter than ±1.0% accuracy\u003c\/li\u003e\n\u003cli\u003ePipe diameters from 1\/2\" to 28\"\u003c\/li\u003e\n\u003cli\u003eProtection class: IP65 (Tek-Clamp 1200A-100F1) ,IP57 (Tek-Clamp 1200A-100M)\u003c\/li\u003e\n\u003cli\u003e4 x 4 key tactile-feedback membrane keypad\u003c\/li\u003e\n\u003cli\u003ePower supply AC 85-264 V or isolation DC 8-36 VDC\u003c\/li\u003e\n\u003cli\u003eLCD with backlight 2 x 20 letters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eItem\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003eUltrasonic Transducers\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eType\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003eBracket Mounted Sensors (Hand Held)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eProtection Class\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003eIP65 (Tek-Clamp 1200A-100F1)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePipe Material\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003eAll metals ,most plastics, fiber glass, etc\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\n\u003ch3\u003eDiscover more about the Tek-Trol Tek-Clamp 1200A Series Ultrasonic Transducers\u003c\/h3\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A_Ultrasonic_Catalog.pdf?v=1789103269\"\u003eCatalog\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A_Ultrasonic_Manual_ff010e8f-c478-4197-a4bd-fe3b08a9716d.pdf?v=1789103275\"\u003eManual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A_Ultrasonic_QSG.pdf?v=1789103281\"\u003eQuick Start Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A-Ultrasonic-Clamp-on-Flowmeter-Datasheet_e7b1cfa0-f6c6-4420-9c4c-c85bacc2dbd8.pdf?v=1789103286\"\u003eDatasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A_ClampOn_ModbusManual.pdf?v=1789103291\"\u003eModbus Map\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A-Water_industry_brochure_en21.r00_W.pdf?v=1789103296\"\u003eWater Industry Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A-OilAndGas_Brochure.pdf?v=1789103301\"\u003eOil and Gas Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eVideos\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=X_wVKDL19GA\u0026amp;t=43s\"\u003eTek-Clamp 1200A Ultrasonic Flow Meter\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=3hE3i6ooxyU\"\u003eTek Clamp 1200A Ultrasonic Clamp On Setup\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=F9tXuQttNGU\"\u003e Tek-Clamp 1200A Ultrasonic Clamp On Flow Meter Flow unit setup\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Tek-Trol","offers":[{"title":"Default Title","offer_id":44163307864142,"sku":"Tek-Clamp 1200A-HSH","price":807.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A-Transducers-Image-1.jpg?v=1791569692"},{"product_id":"tek-trol-tek-clamp-1200a-hmh-ultrasonic-transducers-2-to-28-pipe-bracket-mounted-sensors-hand-held","title":"Tek-Trol Tek-Clamp 1200A-HMH Bracket-Mounted Ultrasonic Transducer Pair for Hand Held Flow Meter, 2\" to 28\" Pipe","description":"\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTek-Trol Tek-Clamp 1200A-HMH Bracket-Mounted Ultrasonic Transducer Pair for Hand Held Flow Meter, 2\" to 28\" Pipe\u003c\/h2\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBetter than ±1.0% accuracy\u003c\/li\u003e\n\u003cli\u003ePipe diameters from 1\/2\" to 28\"\u003c\/li\u003e\n\u003cli\u003eProtection class: IP65 (Tek-Clamp 1200A-100F1) ,IP57 (Tek-Clamp 1200A-100M)\u003c\/li\u003e\n\u003cli\u003e4 x 4 key tactile-feedback membrane keypad\u003c\/li\u003e\n\u003cli\u003ePower supply AC 85-264 V or isolation DC 8-36 VDC\u003c\/li\u003e\n\u003cli\u003eLCD with backlight 2 x 20 letters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eItem\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003eUltrasonic Transducers\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eType\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003eBracket Mounted Sensors (Hand Held)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eProtection Class\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003eIP65 (Tek-Clamp 1200A-100F1)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePipe Material\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003eAll metals ,most plastics, fiber glass, etc\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\n\u003ch3\u003eDiscover more about the Tek-Trol Tek-Clamp 1200A Series Ultrasonic Transducers\u003c\/h3\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A_Ultrasonic_Catalog.pdf?v=1789103269\"\u003eCatalog\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A_Ultrasonic_Manual_ff010e8f-c478-4197-a4bd-fe3b08a9716d.pdf?v=1789103275\"\u003eManual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A_Ultrasonic_QSG.pdf?v=1789103281\"\u003eQuick Start Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A-Ultrasonic-Clamp-on-Flowmeter-Datasheet_e7b1cfa0-f6c6-4420-9c4c-c85bacc2dbd8.pdf?v=1789103286\"\u003eDatasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A_ClampOn_ModbusManual.pdf?v=1789103291\"\u003eModbus Map\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A-Water_industry_brochure_en21.r00_W.pdf?v=1789103296\"\u003eWater Industry Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A-OilAndGas_Brochure.pdf?v=1789103301\"\u003eOil and Gas Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eVideos\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=X_wVKDL19GA\u0026amp;t=43s\"\u003eTek-Clamp 1200A Ultrasonic Flow Meter\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=3hE3i6ooxyU\"\u003eTek Clamp 1200A Ultrasonic Clamp On Setup\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=F9tXuQttNGU\"\u003e Tek-Clamp 1200A Ultrasonic Clamp On Flow Meter Flow unit setup\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Tek-Trol","offers":[{"title":"Default Title","offer_id":44163307995214,"sku":"Tek-Clamp 1200A-HMH","price":952.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A-Transducers-Image-1.jpg?v=1791569692"},{"product_id":"tek-trol-tek-clamp-1200a-100-series-ultrasonic-flow-meter","title":"Tek Trol, Tek-Clamp 1200A-100 Series Ultrasonic Flow Meter","description":"\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTek Trol, Tek-Clamp 1200A-100 Series Ultrasonic Flow Meter\u003c\/h2\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBetter than ±1.0% accuracy\u003c\/li\u003e\n\u003cli\u003e Pipe diameters from 1\" to 28\".\u003c\/li\u003e\n\u003cli\u003eProtection class: IP67 for Flow Transducer\u003c\/li\u003e\n\u003cli\u003e4 x 4 Key Touch Membrane Keypad.\u003c\/li\u003e\n\u003cli\u003e3 AAA built-in Ni-MH batteries 1.2V (for over 12 hours of operation). 90V-260V AC Adapter.\u003c\/li\u003e\n\u003cli\u003e 4 x 16-character LCD with backlight.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eItem\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003eUltrasonic Flow Meter\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eProtection Class\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003eFlow Transducer: IP67 \u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePipe Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e1\/2\" to 28\"\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv\u003e\n\u003cbr\u003e \u003ch3\u003eDiscover more about theTek Trol, Tek-Clamp 1200A-100 Series Ultrasonic Flow Meter\u003c\/h3\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Clamp-1200A-100H_Handheld-Ultrasonic_Catalog.pdf?v=1789103307\" target='_blank\"'\u003eCatalog\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Clamp-1200A-100H_HandheldUltrasonic_Manual_4a28cb1b-e13f-4471-860e-881ad4f46417.pdf?v=1789103312\" target='_blank\"'\u003eManual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Clamp-1200A-100H_Handheld_QSG.pdf?v=1789103317\" target='_blank\"'\u003eQuick Start Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Clamp-1200A-100H_HandheldUltrasonic_Datasheet_94039463-2b4c-40da-ab9f-0afb7fda124e.pdf?v=1789103322\" target='_blank\"'\u003eDatasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A_ClampOn_ModbusManual.pdf?v=1789103291\" target='_blank\"'\u003eModbus Map\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A-Water_industry_brochure_en21.r00_W.pdf?v=1789103296\" target='_blank\"'\u003eWater Industry Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A-OilAndGas_Brochure.pdf?v=1789103301\" target='_blank\"'\u003eOil and Gas Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eVideos\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=X_wVKDL19GA\u0026amp;t=43s\" target='_blank\"'\u003eTek-Clamp 1200A Ultrasonic Flow Meter\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=3hE3i6ooxyU\" target='_blank\"'\u003eTek Clamp 1200A Ultrasonic Clamp On Setup\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=F9tXuQttNGU\" target='_blank\"'\u003e Tek-Clamp 1200A Ultrasonic Clamp On Flow Meter Flow unit setup\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Tek-Trol","offers":[{"title":"Default Title","offer_id":44163308159054,"sku":"TKTRL-Tek-Clamp 1200A-100","price":2628.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Clamp-1200A-Ultrasonic-Flow-Meter-Collection.png?v=1791648052"},{"product_id":"tek-trol-tek-clamp-1200a-100f1-ultrasonic-flow-meter-wall-mount","title":"Tek-Trol Tek-Clamp 1200A-100F1 Ultrasonic Flow Meter","description":"\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTek-Clamp 1200A-100F1 -Wall Mount Ultrasonic Flowmeter\u003c\/h2\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBetter than ±1.0% accuracy\u003c\/li\u003e\n\u003cli\u003ePipe diameters from 1\" to 28\".\u003c\/li\u003e\n\u003cli\u003eProtection class: IP67 for Flow Transducer\u003c\/li\u003e\n\u003cli\u003e4 x 4 Key Touch Membrane Keypad.\u003c\/li\u003e\n\u003cli\u003e3 AAA built-in Ni-MH batteries 1.2V (for over 12 hours of operation). 90V-260V AC Adapter.\u003c\/li\u003e\n\u003cli\u003e4 x 16-character LCD with backlight.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eItem\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003eLow Cost DIN Mount Flowmeter\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eProtection Class\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003eFlow Transducer: IP67\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePipe Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e1\/2\" to 28\"\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\n\u003ch3\u003eDiscover more about theTek Trol, Tek-Clamp 1200A-100 Series Ultrasonic Flow Meter\u003c\/h3\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Clamp-1200A-100H_Handheld-Ultrasonic_Catalog.pdf?v=1789103307\"\u003eCatalog\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Clamp-1200A-100H_HandheldUltrasonic_Manual_4a28cb1b-e13f-4471-860e-881ad4f46417.pdf?v=1789103312\"\u003eManual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Clamp-1200A-100H_Handheld_QSG.pdf?v=1789103317\"\u003eQuick Start Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Clamp-1200A-100H_HandheldUltrasonic_Datasheet_94039463-2b4c-40da-ab9f-0afb7fda124e.pdf?v=1789103322\"\u003eDatasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A_ClampOn_ModbusManual.pdf?v=1789103291\"\u003eModbus Map\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A-Water_industry_brochure_en21.r00_W.pdf?v=1789103296\"\u003eWater Industry Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A-OilAndGas_Brochure.pdf?v=1789103301\"\u003eOil and Gas Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eVideos\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=X_wVKDL19GA\u0026amp;t=43s\"\u003eTek-Clamp 1200A Ultrasonic Flow Meter\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=3hE3i6ooxyU\"\u003eTek Clamp 1200A Ultrasonic Clamp On Setup\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=F9tXuQttNGU\"\u003e Tek-Clamp 1200A Ultrasonic Clamp On Flow Meter Flow unit setup\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Tek-Trol","offers":[{"title":"Default Title","offer_id":44163308290126,"sku":"Tek-Clamp 1200A-100F1","price":2628.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-Tek-Clamp-1200A-100F1-Ultrasonic-Flow-Meter-Wall-Mount.png?v=1791569695"},{"product_id":"tek-trol-tek-clamp-1200a-100m-ultrasonic-flow-meter-low-cost-din","title":"Tek-Trol Tek-Clamp 1200A-100M Ultrasonic Flow Meter -Low Cost DIN","description":"\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTek-Clamp 1200A-100M -Low Cost DIN Mount Ultrasonic Flowmeter\u003c\/h2\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBetter than ±1.0% accuracy\u003c\/li\u003e\n\u003cli\u003ePipe diameters from 1\" to 28\".\u003c\/li\u003e\n\u003cli\u003eProtection class: IP67 for Flow Transducer\u003c\/li\u003e\n\u003cli\u003e4 x 4 Key Touch Membrane Keypad.\u003c\/li\u003e\n\u003cli\u003e3 AAA built-in Ni-MH batteries 1.2V (for over 12 hours of operation). 90V-260V AC Adapter.\u003c\/li\u003e\n\u003cli\u003e4 x 16-character LCD with backlight.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eItem\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003eDIN Mount Ultrasonic Flow Meter\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eProtection Class\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003eFlow Transducer: IP67\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePipe Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e1\/2\" to 28\"\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\n\u003ch3\u003eDiscover more about theTek Trol, Tek-Clamp 1200A-100 Series Ultrasonic Flow Meter\u003c\/h3\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Clamp-1200A-100H_Handheld-Ultrasonic_Catalog.pdf?v=1789103307\"\u003eCatalog\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Clamp-1200A-100H_HandheldUltrasonic_Manual_4a28cb1b-e13f-4471-860e-881ad4f46417.pdf?v=1789103312\"\u003eManual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Clamp-1200A-100H_Handheld_QSG.pdf?v=1789103317\"\u003eQuick Start Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Clamp-1200A-100H_HandheldUltrasonic_Datasheet_94039463-2b4c-40da-ab9f-0afb7fda124e.pdf?v=1789103322\"\u003eDatasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A_ClampOn_ModbusManual.pdf?v=1789103291\"\u003eModbus Map\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A-Water_industry_brochure_en21.r00_W.pdf?v=1789103296\"\u003eWater Industry Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A-OilAndGas_Brochure.pdf?v=1789103301\"\u003eOil and Gas Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eVideos\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=X_wVKDL19GA\u0026amp;t=43s\"\u003eTek-Clamp 1200A Ultrasonic Flow Meter\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=3hE3i6ooxyU\"\u003eTek Clamp 1200A Ultrasonic Clamp On Setup\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=F9tXuQttNGU\"\u003e Tek-Clamp 1200A Ultrasonic Clamp On Flow Meter Flow unit setup\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e To view the transducer specifications or purchase transducers separately, visit the \u003ca href=\"https:\/\/valveman.com\/products\/tek-trol-tek-clamp-1200a-series-ultrasonic-transducers\"\u003eTek-Clamp 1200A Series Ultrasonic Transducers\u003c\/a\u003e page.\u003c\/p\u003e\n","brand":"Tek-Trol","offers":[{"title":"Default Title","offer_id":44163308421198,"sku":"Tek-Clamp 1200A-100M","price":1425.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-Tek-Clamp-1200A-100M-Ultrasonic-Flow-Meter-Low-Cost-DIN.png?v=1791569696"},{"product_id":"tek-trol-tek-clamp-1200a-100h-ultrasonic-flow-meter-hand-held-with-carrying-case","title":"Tek-Trol Tek-Clamp 1200A-100H Ultrasonic Flow Meter -Hand Held (With Carrying Case)","description":"\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTek-Clamp 1200A-100H -Hand Held Ultrasonic Flowmeter (With Carrying Case)\u003c\/h2\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBetter than ±1.0% accuracy\u003c\/li\u003e\n\u003cli\u003ePipe diameters from 1\" to 28\"\u003c\/li\u003e\n\u003cli\u003eProtection class: IP67 for Flow Transducer\u003c\/li\u003e\n\u003cli\u003e4 x 4 Key Touch Membrane Keypad.\u003c\/li\u003e\n\u003cli\u003e3 AAA built-in Ni-MH batteries 1.2V (for over 12 hours of operation). 90V-260V AC Adapter.\u003c\/li\u003e\n\u003cli\u003e4 x 16-character LCD with backlight.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eItem\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003eHand Held (With Carrying Case) Ultrasonic Flowmeter\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eProtection Class\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003eFlow Transducer: IP67\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePipe Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e1\/2\" to 28\"\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\n\u003ch3\u003eDiscover more about theTek Trol, Tek-Clamp 1200A-100 Series Ultrasonic Flow Meter\u003c\/h3\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Clamp-1200A-100H_Handheld-Ultrasonic_Catalog.pdf?v=1789103307\"\u003eCatalog\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Clamp-1200A-100H_HandheldUltrasonic_Manual_4a28cb1b-e13f-4471-860e-881ad4f46417.pdf?v=1789103312\"\u003eManual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Clamp-1200A-100H_Handheld_QSG.pdf?v=1789103317\"\u003eQuick Start Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Clamp-1200A-100H_HandheldUltrasonic_Datasheet_94039463-2b4c-40da-ab9f-0afb7fda124e.pdf?v=1789103322\"\u003eDatasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A_ClampOn_ModbusManual.pdf?v=1789103291\"\u003eModbus Map\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A-Water_industry_brochure_en21.r00_W.pdf?v=1789103296\"\u003eWater Industry Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-1200A-OilAndGas_Brochure.pdf?v=1789103301\"\u003eOil and Gas Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eVideos\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=X_wVKDL19GA\u0026amp;t=43s\"\u003eTek-Clamp 1200A Ultrasonic Flow Meter\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=3hE3i6ooxyU\"\u003eTek Clamp 1200A Ultrasonic Clamp On Setup\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=F9tXuQttNGU\"\u003e Tek-Clamp 1200A Ultrasonic Clamp On Flow Meter Flow unit setup\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Tek-Trol","offers":[{"title":"Default Title","offer_id":44163308585038,"sku":"Tek-Clamp 1200A-100H","price":2919.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Clamp-1200A-100H-with-Carrying-Case.png?v=1791647480"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/collections\/flow_20meter_20-_20ultrasonic_20flow_20meter__65742.png?v=1786581601","url":"https:\/\/valveman.com\/collections\/ultrasonic-flow-meters.oembed","provider":"ValveMan","version":"1.0","type":"link"}