{"title":"Volume Boosters","description":null,"products":[{"product_id":"controlair-type-600-series-ratio-relay-volume-booster-ca-t600-1-4-in-type-600-ratio-1-1-1-6-1-4-npt","title":"ControlAir Type 600 Series Ratio Relay Volume Booster, CA-T600-1\/4-in, Type 600, Ratio 1:1 - 1:6, 1\/4\" NPT","description":"\u003ch2\u003eControlAir Type 600 Series Ratio Relay Volume Booster\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHigh Flow Capacity: Allows flows up to 50 SCFM (1,400 Nl\/min)\u003c\/li\u003e\n\u003cli\u003eMultiple Signal to Output Ratios: 1:1, 1:2, 1:3, 1:6, 2:1 and 3:1.\u003c\/li\u003e\n\u003cli\u003eStable Output: Venturi aspirator maintains output pressure under varying flow conditions.\u003c\/li\u003e\n\u003cli\u003eMultiple Port Sizes: Available in 1\/4\", 3\/8\" and 1\/2\" NPT\/BSPP.\u003c\/li\u003e\n\u003cli\u003eBalanced Supply Valve: Rolling diaphragm design makes unit insensitive to supply pressure variation.\u003c\/li\u003e\n\u003cli\u003eOptional Negative Bias: 4 psi (0.3 bar) negative bias option allows \"zero\" of I\/P's.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eMeet High Flow Requirements With A Low Flow Pneumatic Signal\u003c\/h2\u003e\u003cp\u003eThe Type 600 ratio relay volume booster is designed to use a pneumatic signal to produce an output pressure which has high flow capacity and can be amplified. This unit is most useful for systems requiring the conversion of a low flow control signal to the higher flow requirements of an operating system. Using an independent supply pressure for greater volume, the Type 600 relays up to 50 scfm (1,400 Nl\/min) flow capacity to a final control element such as a valve actuator. The standard signal to output ratio is 1:1, however, the Type 600 is also available with an amplified ratio of 1:2, 1:3 and 1:6.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal\/Output Ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1:1, 1:2, 1:3, 1:6, 2:1, 3:1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eFlow Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e50 scfm (1415 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePort Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\" BSPP, 1\/2\" NPT, 1\/4\" BSPP, 1\/4\" NPT, 3\/8\" BSPP, 3\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal Port Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/4\" NPT, 1\/4\" BSP\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Port Size (optional)\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Flow Cv\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eSee PDF Sales Sheet\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSensitivity (depending on ratio) water column\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.25\" to 1.5\" (0.64 to 3.8 cm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eRatio Accuracy- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0% to 2.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eZero Error- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e2.0% to 3.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSupply Pressure Sensitivity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.1 to 0.6 psig for a change of 50 pis (3.5 bar) in supply pressure\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAir Consumption, Maximum depending on output range\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0 to 10 scfh (0.5 to 5.0 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Supply Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 psig (17 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Output Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 psig (10 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Signal Pressure depending on ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 to 25 psig (10.34 to 1.27 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAmbient Temperature Limits\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e-40° to 160°F (-40° to 71°C)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eWeight\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.4 lbs (635 gm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMounting Options\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003ePipe, panel, bracket\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eAluminium\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOther Internal Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eStainless steel, brass, plated steel, acetal, nitrile, polyester\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster-Spec-Sheet1.pdf?v=1786493176\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"ControlAir","offers":[{"title":"Default Title","offer_id":44165542314062,"sku":"CA-T600-1\/4-in","price":186.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster__36181.1784299845.1280.1280.jpg?v=1786659686"},{"product_id":"controlair-type-600-series-ratio-relay-volume-booster-429-841-026-600-ba-ratio-1-1-1-4-npt","title":"ControlAir Type 600 Series Ratio Relay Volume Booster, 429-841-026, 600-BA, Ratio 1:1, 1\/4\" NPT","description":"\u003ch2\u003eControlAir Type 600 Series Ratio Relay Volume Booster (600-BA)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHigh Flow Capacity: Allows flows up to 50 SCFM (1,400 Nl\/min)\u003c\/li\u003e\n\u003cli\u003eMultiple Signal to Output Ratios: 1:1, 1:2, 1:3, 1:6, 2:1 and 3:1.\u003c\/li\u003e\n\u003cli\u003eStable Output: Venturi aspirator maintains output pressure under varying flow conditions.\u003c\/li\u003e\n\u003cli\u003eMultiple Port Sizes: Available in 1\/4\", 3\/8\" and 1\/2\" NPT\/BSPP.\u003c\/li\u003e\n\u003cli\u003eBalanced Supply Valve: Rolling diaphragm design makes unit insensitive to supply pressure variation.\u003c\/li\u003e\n\u003cli\u003eOptional Negative Bias: 4 psi (0.3 bar) negative bias option allows \"zero\" of I\/P's.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eMeet High Flow Requirements With A Low Flow Pneumatic Signal\u003c\/h2\u003e\u003cp\u003eThe Type 600 ratio relay volume booster is designed to use a pneumatic signal to produce an output pressure which has high flow capacity and can be amplified. This unit is most useful for systems requiring the conversion of a low flow control signal to the higher flow requirements of an operating system. Using an independent supply pressure for greater volume, the Type 600 relays up to 50 scfm (1,400 Nl\/min) flow capacity to a final control element such as a valve actuator. The standard signal to output ratio is 1:1, however, the Type 600 is also available with an amplified ratio of 1:2, 1:3 and 1:6.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal\/Output Ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1:1, 1:2, 1:3, 1:6, 2:1, 3:1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eFlow Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e50 scfm (1415 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePort Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\" BSPP, 1\/2\" NPT, 1\/4\" BSPP, 1\/4\" NPT, 3\/8\" BSPP, 3\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal Port Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/4\" NPT, 1\/4\" BSP\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Port Size (optional)\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Flow Cv\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eSee PDF Sales Sheet\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSensitivity (depending on ratio) water column\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.25\" to 1.5\" (0.64 to 3.8 cm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eRatio Accuracy- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0% to 2.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eZero Error- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e2.0% to 3.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSupply Pressure Sensitivity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.1 to 0.6 psig for a change of 50 pis (3.5 bar) in supply pressure\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAir Consumption, Maximum depending on output range\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0 to 10 scfh (0.5 to 5.0 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Supply Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 psig (17 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Output Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 psig (10 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Signal Pressure depending on ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 to 25 psig (10.34 to 1.27 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAmbient Temperature Limits\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e-40° to 160°F (-40° to 71°C)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eWeight\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.4 lbs (635 gm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMounting Options\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003ePipe, panel, bracket\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eAluminium\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOther Internal Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eStainless steel, brass, plated steel, acetal, nitrile, polyester\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e429-841-026\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster-Spec-Sheet1.pdf?v=1786493176\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"ControlAir","offers":[{"title":"Default Title","offer_id":44165542510670,"sku":"429-841-026","price":186.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster__18791.1784299736.1280.1280.jpg?v=1786659689"},{"product_id":"controlair-type-600-series-ratio-relay-volume-booster-429-841-045-600-bae-ratio-1-1-1-4-npt-tapped-exhaust","title":"ControlAir Type 600 Series Ratio Relay Volume Booster, 429-841-045, 600-BAE, Ratio 1:1, 1\/4\" NPT, Tapped Exhaust","description":"\u003ch2\u003eControlAir Type 600 Series Ratio Relay Volume Booster (600-BAE)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHigh Flow Capacity: Allows flows up to 50 SCFM (1,400 Nl\/min)\u003c\/li\u003e\n\u003cli\u003eMultiple Signal to Output Ratios: 1:1, 1:2, 1:3, 1:6, 2:1 and 3:1.\u003c\/li\u003e\n\u003cli\u003eStable Output: Venturi aspirator maintains output pressure under varying flow conditions.\u003c\/li\u003e\n\u003cli\u003eMultiple Port Sizes: Available in 1\/4\", 3\/8\" and 1\/2\" NPT\/BSPP.\u003c\/li\u003e\n\u003cli\u003eBalanced Supply Valve: Rolling diaphragm design makes unit insensitive to supply pressure variation.\u003c\/li\u003e\n\u003cli\u003eOptional Negative Bias: 4 psi (0.3 bar) negative bias option allows \"zero\" of I\/P's.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eMeet High Flow Requirements With A Low Flow Pneumatic Signal\u003c\/h2\u003e\u003cp\u003eThe Type 600 ratio relay volume booster is designed to use a pneumatic signal to produce an output pressure which has high flow capacity and can be amplified. This unit is most useful for systems requiring the conversion of a low flow control signal to the higher flow requirements of an operating system. Using an independent supply pressure for greater volume, the Type 600 relays up to 50 scfm (1,400 Nl\/min) flow capacity to a final control element such as a valve actuator. The standard signal to output ratio is 1:1, however, the Type 600 is also available with an amplified ratio of 1:2, 1:3 and 1:6.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal\/Output Ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1:1, 1:2, 1:3, 1:6, 2:1, 3:1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eFlow Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e50 scfm (1415 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePort Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\" BSPP, 1\/2\" NPT, 1\/4\" BSPP, 1\/4\" NPT, 3\/8\" BSPP, 3\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal Port Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/4\" NPT, 1\/4\" BSP\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Port Size (optional)\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Flow Cv\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eSee PDF Sales Sheet\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSensitivity (depending on ratio) water column\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.25\" to 1.5\" (0.64 to 3.8 cm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eRatio Accuracy- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0% to 2.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eZero Error- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e2.0% to 3.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSupply Pressure Sensitivity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.1 to 0.6 psig for a change of 50 pis (3.5 bar) in supply pressure\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAir Consumption, Maximum depending on output range\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0 to 10 scfh (0.5 to 5.0 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Supply Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 psig (17 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Output Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 psig (10 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Signal Pressure depending on ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 to 25 psig (10.34 to 1.27 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAmbient Temperature Limits\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e-40° to 160°F (-40° to 71°C)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eWeight\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.4 lbs (635 gm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMounting Options\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003ePipe, panel, bracket\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eAluminium\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOther Internal Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eStainless steel, brass, plated steel, acetal, nitrile, polyester\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e429-841-026\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eTapped Exhaust: Yes\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster-Spec-Sheet1.pdf?v=1786493176\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"ControlAir","offers":[{"title":"Default Title","offer_id":44165542707278,"sku":"429-841-045","price":209.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster__90120.1784299774.1280.1280.jpg?v=1786659692"},{"product_id":"controlair-type-600-series-ratio-relay-volume-booster-429-841-256-600-baeu-ratio-1-1-1-4-npt-tapped-exhaust-bsp-porting","title":"ControlAir Type 600 Series Ratio Relay Volume Booster, 429-841-256, 600-BAEU, Ratio 1:1, 1\/4\" NPT, Tapped Exhaust, BSP Porting","description":"\u003ch2\u003eControlAir Type 600 Series Ratio Relay Volume Booster (600-BAEU)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHigh Flow Capacity: Allows flows up to 50 SCFM (1,400 Nl\/min)\u003c\/li\u003e\n\u003cli\u003eMultiple Signal to Output Ratios: 1:1, 1:2, 1:3, 1:6, 2:1 and 3:1.\u003c\/li\u003e\n\u003cli\u003eStable Output: Venturi aspirator maintains output pressure under varying flow conditions.\u003c\/li\u003e\n\u003cli\u003eMultiple Port Sizes: Available in 1\/4\", 3\/8\" and 1\/2\" NPT\/BSPP.\u003c\/li\u003e\n\u003cli\u003eBalanced Supply Valve: Rolling diaphragm design makes unit insensitive to supply pressure variation.\u003c\/li\u003e\n\u003cli\u003eOptional Negative Bias: 4 psi (0.3 bar) negative bias option allows \"zero\" of I\/P's.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eMeet High Flow Requirements With A Low Flow Pneumatic Signal\u003c\/h2\u003e\u003cp\u003eThe Type 600 ratio relay volume booster is designed to use a pneumatic signal to produce an output pressure which has high flow capacity and can be amplified. This unit is most useful for systems requiring the conversion of a low flow control signal to the higher flow requirements of an operating system. Using an independent supply pressure for greater volume, the Type 600 relays up to 50 scfm (1,400 Nl\/min) flow capacity to a final control element such as a valve actuator. The standard signal to output ratio is 1:1, however, the Type 600 is also available with an amplified ratio of 1:2, 1:3 and 1:6.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal\/Output Ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1:1, 1:2, 1:3, 1:6, 2:1, 3:1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eFlow Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e50 scfm (1415 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePort Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\" BSPP, 1\/2\" NPT, 1\/4\" BSPP, 1\/4\" NPT, 3\/8\" BSPP, 3\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal Port Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/4\" NPT, 1\/4\" BSP\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Port Size (optional)\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Flow Cv\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eSee PDF Sales Sheet\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSensitivity (depending on ratio) water column\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.25\" to 1.5\" (0.64 to 3.8 cm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eRatio Accuracy- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0% to 2.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eZero Error- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e2.0% to 3.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSupply Pressure Sensitivity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.1 to 0.6 psig for a change of 50 pis (3.5 bar) in supply pressure\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAir Consumption, Maximum depending on output range\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0 to 10 scfh (0.5 to 5.0 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Supply Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 psig (17 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Output Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 psig (10 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Signal Pressure depending on ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 to 25 psig (10.34 to 1.27 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAmbient Temperature Limits\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e-40° to 160°F (-40° to 71°C)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eWeight\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.4 lbs (635 gm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMounting Options\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003ePipe, panel, bracket\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eAluminium\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOther Internal Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eStainless steel, brass, plated steel, acetal, nitrile, polyester\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e429-841-256\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eTapped Exhaust: Yes, BSP Porting: Yes\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster-Spec-Sheet1.pdf?v=1786493176\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"ControlAir","offers":[{"title":"Default Title","offer_id":44165543034958,"sku":"429-841-256","price":209.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster__25316.1784299845.1280.1280.jpg?v=1786659695"},{"product_id":"controlair-type-600-series-ratio-relay-volume-booster-429-841-123-600-baez-ratio-1-1-1-4-npt-tapped-exhaust-fixed-negative-bias","title":"ControlAir Type 600 Series Ratio Relay Volume Booster, 429-841-123, 600-BAEZ, Ratio 1:1, 1\/4\" NPT, Tapped Exhaust, Fixed Negative Bias","description":"\u003ch2\u003eControlAir Type 600 Series Ratio Relay Volume Booster (600-BAEZ)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHigh Flow Capacity: Allows flows up to 50 SCFM (1,400 Nl\/min)\u003c\/li\u003e\n\u003cli\u003eMultiple Signal to Output Ratios: 1:1, 1:2, 1:3, 1:6, 2:1 and 3:1.\u003c\/li\u003e\n\u003cli\u003eStable Output: Venturi aspirator maintains output pressure under varying flow conditions.\u003c\/li\u003e\n\u003cli\u003eMultiple Port Sizes: Available in 1\/4\", 3\/8\" and 1\/2\" NPT\/BSPP.\u003c\/li\u003e\n\u003cli\u003eBalanced Supply Valve: Rolling diaphragm design makes unit insensitive to supply pressure variation.\u003c\/li\u003e\n\u003cli\u003eOptional Negative Bias: 4 psi (0.3 bar) negative bias option allows \"zero\" of I\/P's.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eMeet High Flow Requirements With A Low Flow Pneumatic Signal\u003c\/h2\u003e\u003cp\u003eThe Type 600 ratio relay volume booster is designed to use a pneumatic signal to produce an output pressure which has high flow capacity and can be amplified. This unit is most useful for systems requiring the conversion of a low flow control signal to the higher flow requirements of an operating system. Using an independent supply pressure for greater volume, the Type 600 relays up to 50 scfm (1,400 Nl\/min) flow capacity to a final control element such as a valve actuator. The standard signal to output ratio is 1:1, however, the Type 600 is also available with an amplified ratio of 1:2, 1:3 and 1:6.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal\/Output Ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1:1, 1:2, 1:3, 1:6, 2:1, 3:1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eFlow Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e50 scfm (1415 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePort Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\" BSPP, 1\/2\" NPT, 1\/4\" BSPP, 1\/4\" NPT, 3\/8\" BSPP, 3\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal Port Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/4\" NPT, 1\/4\" BSP\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Port Size (optional)\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Flow Cv\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eSee PDF Sales Sheet\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSensitivity (depending on ratio) water column\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.25\" to 1.5\" (0.64 to 3.8 cm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eRatio Accuracy- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0% to 2.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eZero Error- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e2.0% to 3.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSupply Pressure Sensitivity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.1 to 0.6 psig for a change of 50 pis (3.5 bar) in supply pressure\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAir Consumption, Maximum depending on output range\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0 to 10 scfh (0.5 to 5.0 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Supply Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 psig (17 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Output Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 psig (10 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Signal Pressure depending on ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 to 25 psig (10.34 to 1.27 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAmbient Temperature Limits\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e-40° to 160°F (-40° to 71°C)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eWeight\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.4 lbs (635 gm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMounting Options\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003ePipe, panel, bracket\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eAluminium\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOther Internal Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eStainless steel, brass, plated steel, acetal, nitrile, polyester\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e429-841-123\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eTapped Exhaust: Yes, Fixed Negative Bias: Yes\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster-Spec-Sheet1.pdf?v=1786493176\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"ControlAir","offers":[{"title":"Default Title","offer_id":44165543264334,"sku":"429-841-123","price":241.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster__76379.1784299907.1280.1280.jpg?v=1786659700"},{"product_id":"controlair-type-600-series-ratio-relay-volume-booster-429-841-234-600-bau-ratio-1-1-1-4-npt-bsp-porting","title":"ControlAir Type 600 Series Ratio Relay Volume Booster, 429-841-234, 600-BAU, Ratio 1:1, 1\/4\" NPT, BSP Porting","description":"\u003ch2\u003eControlAir Type 600 Series Ratio Relay Volume Booster (600-BAU)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHigh Flow Capacity: Allows flows up to 50 SCFM (1,400 Nl\/min)\u003c\/li\u003e\n\u003cli\u003eMultiple Signal to Output Ratios: 1:1, 1:2, 1:3, 1:6, 2:1 and 3:1.\u003c\/li\u003e\n\u003cli\u003eStable Output: Venturi aspirator maintains output pressure under varying flow conditions.\u003c\/li\u003e\n\u003cli\u003eMultiple Port Sizes: Available in 1\/4\", 3\/8\" and 1\/2\" NPT\/BSPP.\u003c\/li\u003e\n\u003cli\u003eBalanced Supply Valve: Rolling diaphragm design makes unit insensitive to supply pressure variation.\u003c\/li\u003e\n\u003cli\u003eOptional Negative Bias: 4 psi (0.3 bar) negative bias option allows \"zero\" of I\/P's.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eMeet High Flow Requirements With A Low Flow Pneumatic Signal\u003c\/h2\u003e\u003cp\u003eThe Type 600 ratio relay volume booster is designed to use a pneumatic signal to produce an output pressure which has high flow capacity and can be amplified. This unit is most useful for systems requiring the conversion of a low flow control signal to the higher flow requirements of an operating system. Using an independent supply pressure for greater volume, the Type 600 relays up to 50 scfm (1,400 Nl\/min) flow capacity to a final control element such as a valve actuator. The standard signal to output ratio is 1:1, however, the Type 600 is also available with an amplified ratio of 1:2, 1:3 and 1:6.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal\/Output Ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1:1, 1:2, 1:3, 1:6, 2:1, 3:1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eFlow Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e50 scfm (1415 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePort Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\" BSPP, 1\/2\" NPT, 1\/4\" BSPP, 1\/4\" NPT, 3\/8\" BSPP, 3\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal Port Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/4\" NPT, 1\/4\" BSP\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Port Size (optional)\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Flow Cv\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eSee PDF Sales Sheet\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSensitivity (depending on ratio) water column\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.25\" to 1.5\" (0.64 to 3.8 cm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eRatio Accuracy- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0% to 2.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eZero Error- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e2.0% to 3.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSupply Pressure Sensitivity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.1 to 0.6 psig for a change of 50 pis (3.5 bar) in supply pressure\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAir Consumption, Maximum depending on output range\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0 to 10 scfh (0.5 to 5.0 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Supply Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 psig (17 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Output Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 psig (10 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Signal Pressure depending on ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 to 25 psig (10.34 to 1.27 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAmbient Temperature Limits\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e-40° to 160°F (-40° to 71°C)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eWeight\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.4 lbs (635 gm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMounting Options\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003ePipe, panel, bracket\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eAluminium\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOther Internal Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eStainless steel, brass, plated steel, acetal, nitrile, polyester\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e429-841-234\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eBSP Porting: Yes\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster-Spec-Sheet1.pdf?v=1786493176\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"ControlAir","offers":[{"title":"Default Title","offer_id":44165543428174,"sku":"429-841-234","price":186.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster__87898.1784299774.1280.1280.jpg?v=1786659703"},{"product_id":"controlair-type-600-series-ratio-relay-volume-booster-429-841-329-600-bauz-ratio-1-1-1-4-npt-bsp-porting-fixed-negative-bias","title":"ControlAir Type 600 Series Ratio Relay Volume Booster, 429-841-329, 600-BAUZ, Ratio 1:1, 1\/4\" NPT, BSP Porting, Fixed Negative Bias","description":"\u003ch2\u003eControlAir Type 600 Series Ratio Relay Volume Booster (600-BAUZ)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHigh Flow Capacity: Allows flows up to 50 SCFM (1,400 Nl\/min)\u003c\/li\u003e\n\u003cli\u003eMultiple Signal to Output Ratios: 1:1, 1:2, 1:3, 1:6, 2:1 and 3:1.\u003c\/li\u003e\n\u003cli\u003eStable Output: Venturi aspirator maintains output pressure under varying flow conditions.\u003c\/li\u003e\n\u003cli\u003eMultiple Port Sizes: Available in 1\/4\", 3\/8\" and 1\/2\" NPT\/BSPP.\u003c\/li\u003e\n\u003cli\u003eBalanced Supply Valve: Rolling diaphragm design makes unit insensitive to supply pressure variation.\u003c\/li\u003e\n\u003cli\u003eOptional Negative Bias: 4 psi (0.3 bar) negative bias option allows \"zero\" of I\/P's.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eMeet High Flow Requirements With A Low Flow Pneumatic Signal\u003c\/h2\u003e\u003cp\u003eThe Type 600 ratio relay volume booster is designed to use a pneumatic signal to produce an output pressure which has high flow capacity and can be amplified. This unit is most useful for systems requiring the conversion of a low flow control signal to the higher flow requirements of an operating system. Using an independent supply pressure for greater volume, the Type 600 relays up to 50 scfm (1,400 Nl\/min) flow capacity to a final control element such as a valve actuator. The standard signal to output ratio is 1:1, however, the Type 600 is also available with an amplified ratio of 1:2, 1:3 and 1:6.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal\/Output Ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1:1, 1:2, 1:3, 1:6, 2:1, 3:1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eFlow Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e50 scfm (1415 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePort Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\" BSPP, 1\/2\" NPT, 1\/4\" BSPP, 1\/4\" NPT, 3\/8\" BSPP, 3\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal Port Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/4\" NPT, 1\/4\" BSP\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Port Size (optional)\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Flow Cv\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eSee PDF Sales Sheet\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSensitivity (depending on ratio) water column\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.25\" to 1.5\" (0.64 to 3.8 cm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eRatio Accuracy- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0% to 2.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eZero Error- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e2.0% to 3.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSupply Pressure Sensitivity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.1 to 0.6 psig for a change of 50 pis (3.5 bar) in supply pressure\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAir Consumption, Maximum depending on output range\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0 to 10 scfh (0.5 to 5.0 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Supply Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 psig (17 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Output Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 psig (10 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Signal Pressure depending on ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 to 25 psig (10.34 to 1.27 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAmbient Temperature Limits\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e-40° to 160°F (-40° to 71°C)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eWeight\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.4 lbs (635 gm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMounting Options\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003ePipe, panel, bracket\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eAluminium\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOther Internal Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eStainless steel, brass, plated steel, acetal, nitrile, polyester\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e429-841-329\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eBSP Porting: Yes, Fixed Negative Bias: Yes\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster-Spec-Sheet1.pdf?v=1786493176\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"ControlAir","offers":[{"title":"Default Title","offer_id":44165543985230,"sku":"429-841-329","price":217.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster__52163.1784299908.1280.1280.jpg?v=1786659705"},{"product_id":"controlair-type-600-series-ratio-relay-volume-booster-429-841-295-600-bax-ratio-1-1-1-4-npt-atex-2014-34-eu","title":"ControlAir Type 600 Series Ratio Relay Volume Booster, 429-841-295, 600-BAX, Ratio 1:1, 1\/4\" NPT, ATEX 2014\/34\/EU","description":"\u003ch2\u003eControlAir Type 600 Series Ratio Relay Volume Booster (600-BAX)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHigh Flow Capacity: Allows flows up to 50 SCFM (1,400 Nl\/min)\u003c\/li\u003e\n\u003cli\u003eMultiple Signal to Output Ratios: 1:1, 1:2, 1:3, 1:6, 2:1 and 3:1.\u003c\/li\u003e\n\u003cli\u003eStable Output: Venturi aspirator maintains output pressure under varying flow conditions.\u003c\/li\u003e\n\u003cli\u003eMultiple Port Sizes: Available in 1\/4\", 3\/8\" and 1\/2\" NPT\/BSPP.\u003c\/li\u003e\n\u003cli\u003eBalanced Supply Valve: Rolling diaphragm design makes unit insensitive to supply pressure variation.\u003c\/li\u003e\n\u003cli\u003eOptional Negative Bias: 4 psi (0.3 bar) negative bias option allows \"zero\" of I\/P's.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eMeet High Flow Requirements With A Low Flow Pneumatic Signal\u003c\/h2\u003e\u003cp\u003eThe Type 600 ratio relay volume booster is designed to use a pneumatic signal to produce an output pressure which has high flow capacity and can be amplified. This unit is most useful for systems requiring the conversion of a low flow control signal to the higher flow requirements of an operating system. Using an independent supply pressure for greater volume, the Type 600 relays up to 50 scfm (1,400 Nl\/min) flow capacity to a final control element such as a valve actuator. The standard signal to output ratio is 1:1, however, the Type 600 is also available with an amplified ratio of 1:2, 1:3 and 1:6.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal\/Output Ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1:1, 1:2, 1:3, 1:6, 2:1, 3:1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eFlow Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e50 scfm (1415 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePort Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\" BSPP, 1\/2\" NPT, 1\/4\" BSPP, 1\/4\" NPT, 3\/8\" BSPP, 3\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal Port Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/4\" NPT, 1\/4\" BSP\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Port Size (optional)\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Flow Cv\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eSee PDF Sales Sheet\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSensitivity (depending on ratio) water column\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.25\" to 1.5\" (0.64 to 3.8 cm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eRatio Accuracy- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0% to 2.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eZero Error- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e2.0% to 3.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSupply Pressure Sensitivity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.1 to 0.6 psig for a change of 50 pis (3.5 bar) in supply pressure\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAir Consumption, Maximum depending on output range\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0 to 10 scfh (0.5 to 5.0 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Supply Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 psig (17 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Output Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 psig (10 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Signal Pressure depending on ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 to 25 psig (10.34 to 1.27 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAmbient Temperature Limits\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e-40° to 160°F (-40° to 71°C)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eWeight\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.4 lbs (635 gm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMounting Options\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003ePipe, panel, bracket\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eAluminium\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOther Internal Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eStainless steel, brass, plated steel, acetal, nitrile, polyester\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e429-841-295\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eATEX 2014\/34\/EU: Yes\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster-Spec-Sheet1.pdf?v=1786493176\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"ControlAir","offers":[{"title":"Default Title","offer_id":44165544869966,"sku":"429-841-295","price":192.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster__73657.1784299846.1280.1280.jpg?v=1786659708"},{"product_id":"controlair-type-600-series-ratio-relay-volume-booster-429-841-033-600-baz-ratio-1-1-1-4-npt-fixed-negative-bias","title":"ControlAir Type 600 Series Ratio Relay Volume Booster, 429-841-033, 600-BAZ, Ratio 1:1, 1\/4\" NPT, Fixed Negative Bias","description":"\u003ch2\u003eControlAir Type 600 Series Ratio Relay Volume Booster (600-BAZ)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHigh Flow Capacity: Allows flows up to 50 SCFM (1,400 Nl\/min)\u003c\/li\u003e\n\u003cli\u003eMultiple Signal to Output Ratios: 1:1, 1:2, 1:3, 1:6, 2:1 and 3:1.\u003c\/li\u003e\n\u003cli\u003eStable Output: Venturi aspirator maintains output pressure under varying flow conditions.\u003c\/li\u003e\n\u003cli\u003eMultiple Port Sizes: Available in 1\/4\", 3\/8\" and 1\/2\" NPT\/BSPP.\u003c\/li\u003e\n\u003cli\u003eBalanced Supply Valve: Rolling diaphragm design makes unit insensitive to supply pressure variation.\u003c\/li\u003e\n\u003cli\u003eOptional Negative Bias: 4 psi (0.3 bar) negative bias option allows \"zero\" of I\/P's.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eMeet High Flow Requirements With A Low Flow Pneumatic Signal\u003c\/h2\u003e\u003cp\u003eThe Type 600 ratio relay volume booster is designed to use a pneumatic signal to produce an output pressure which has high flow capacity and can be amplified. This unit is most useful for systems requiring the conversion of a low flow control signal to the higher flow requirements of an operating system. Using an independent supply pressure for greater volume, the Type 600 relays up to 50 scfm (1,400 Nl\/min) flow capacity to a final control element such as a valve actuator. The standard signal to output ratio is 1:1, however, the Type 600 is also available with an amplified ratio of 1:2, 1:3 and 1:6.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal\/Output Ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1:1, 1:2, 1:3, 1:6, 2:1, 3:1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eFlow Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e50 scfm (1415 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePort Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\" BSPP, 1\/2\" NPT, 1\/4\" BSPP, 1\/4\" NPT, 3\/8\" BSPP, 3\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal Port Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/4\" NPT, 1\/4\" BSP\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Port Size (optional)\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Flow Cv\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eSee PDF Sales Sheet\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSensitivity (depending on ratio) water column\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.25\" to 1.5\" (0.64 to 3.8 cm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eRatio Accuracy- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0% to 2.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eZero Error- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e2.0% to 3.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSupply Pressure Sensitivity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.1 to 0.6 psig for a change of 50 pis (3.5 bar) in supply pressure\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAir Consumption, Maximum depending on output range\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0 to 10 scfh (0.5 to 5.0 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Supply Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 psig (17 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Output Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 psig (10 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Signal Pressure depending on ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 to 25 psig (10.34 to 1.27 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAmbient Temperature Limits\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e-40° to 160°F (-40° to 71°C)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eWeight\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.4 lbs (635 gm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMounting Options\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003ePipe, panel, bracket\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eAluminium\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOther Internal Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eStainless steel, brass, plated steel, acetal, nitrile, polyester\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e429-841-033\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eFixed Negative Bias: Yes\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster-Spec-Sheet1.pdf?v=1786493176\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"ControlAir","offers":[{"title":"Default Title","offer_id":44165545427022,"sku":"429-841-033","price":217.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster__19859.1784299846.1280.1280.jpg?v=1786659710"},{"product_id":"controlair-type-600-series-ratio-relay-volume-booster-429-842-218-600-bb-ratio-1-2-1-4-npt","title":"ControlAir Type 600 Series Ratio Relay Volume Booster, 429-842-218, 600-BB, Ratio 1:2, 1\/4\" NPT","description":"\u003ch2\u003eControlAir Type 600 Series Ratio Relay Volume Booster (600-BB)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHigh Flow Capacity: Allows flows up to 50 SCFM (1,400 Nl\/min)\u003c\/li\u003e\n\u003cli\u003eMultiple Signal to Output Ratios: 1:1, 1:2, 1:3, 1:6, 2:1 and 3:1.\u003c\/li\u003e\n\u003cli\u003eStable Output: Venturi aspirator maintains output pressure under varying flow conditions.\u003c\/li\u003e\n\u003cli\u003eMultiple Port Sizes: Available in 1\/4\", 3\/8\" and 1\/2\" NPT\/BSPP.\u003c\/li\u003e\n\u003cli\u003eBalanced Supply Valve: Rolling diaphragm design makes unit insensitive to supply pressure variation.\u003c\/li\u003e\n\u003cli\u003eOptional Negative Bias: 4 psi (0.3 bar) negative bias option allows \"zero\" of I\/P's.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eMeet High Flow Requirements With A Low Flow Pneumatic Signal\u003c\/h2\u003e\u003cp\u003eThe Type 600 ratio relay volume booster is designed to use a pneumatic signal to produce an output pressure which has high flow capacity and can be amplified. This unit is most useful for systems requiring the conversion of a low flow control signal to the higher flow requirements of an operating system. Using an independent supply pressure for greater volume, the Type 600 relays up to 50 scfm (1,400 Nl\/min) flow capacity to a final control element such as a valve actuator. The standard signal to output ratio is 1:1, however, the Type 600 is also available with an amplified ratio of 1:2, 1:3 and 1:6.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal\/Output Ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1:1, 1:2, 1:3, 1:6, 2:1, 3:1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eFlow Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e50 scfm (1415 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePort Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\" BSPP, 1\/2\" NPT, 1\/4\" BSPP, 1\/4\" NPT, 3\/8\" BSPP, 3\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal Port Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/4\" NPT, 1\/4\" BSP\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Port Size (optional)\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Flow Cv\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eSee PDF Sales Sheet\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSensitivity (depending on ratio) water column\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.25\" to 1.5\" (0.64 to 3.8 cm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eRatio Accuracy- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0% to 2.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eZero Error- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e2.0% to 3.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSupply Pressure Sensitivity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.1 to 0.6 psig for a change of 50 pis (3.5 bar) in supply pressure\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAir Consumption, Maximum depending on output range\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0 to 10 scfh (0.5 to 5.0 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Supply Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 psig (17 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Output Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 psig (10 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Signal Pressure depending on ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 to 25 psig (10.34 to 1.27 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAmbient Temperature Limits\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e-40° to 160°F (-40° to 71°C)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eWeight\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.4 lbs (635 gm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMounting Options\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003ePipe, panel, bracket\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eAluminium\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOther Internal Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eStainless steel, brass, plated steel, acetal, nitrile, polyester\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e429-842-218\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster-Spec-Sheet1.pdf?v=1786493176\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"ControlAir","offers":[{"title":"Default Title","offer_id":44165545984078,"sku":"429-842-218","price":251.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster__12146.1784299736.1280.1280.jpg?v=1786659713"},{"product_id":"controlair-type-600-series-ratio-relay-volume-booster-429-842-292-600-bbe-ratio-1-2-1-4-npt-tapped-exhaust","title":"ControlAir Type 600 Series Ratio Relay Volume Booster, 429-842-292, 600-BBE, Ratio 1:2, 1\/4\" NPT, Tapped Exhaust","description":"\u003ch2\u003eControlAir Type 600 Series Ratio Relay Volume Booster (600-BBE)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHigh Flow Capacity: Allows flows up to 50 SCFM (1,400 Nl\/min)\u003c\/li\u003e\n\u003cli\u003eMultiple Signal to Output Ratios: 1:1, 1:2, 1:3, 1:6, 2:1 and 3:1.\u003c\/li\u003e\n\u003cli\u003eStable Output: Venturi aspirator maintains output pressure under varying flow conditions.\u003c\/li\u003e\n\u003cli\u003eMultiple Port Sizes: Available in 1\/4\", 3\/8\" and 1\/2\" NPT\/BSPP.\u003c\/li\u003e\n\u003cli\u003eBalanced Supply Valve: Rolling diaphragm design makes unit insensitive to supply pressure variation.\u003c\/li\u003e\n\u003cli\u003eOptional Negative Bias: 4 psi (0.3 bar) negative bias option allows \"zero\" of I\/P's.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eMeet High Flow Requirements With A Low Flow Pneumatic Signal\u003c\/h2\u003e\u003cp\u003eThe Type 600 ratio relay volume booster is designed to use a pneumatic signal to produce an output pressure which has high flow capacity and can be amplified. This unit is most useful for systems requiring the conversion of a low flow control signal to the higher flow requirements of an operating system. Using an independent supply pressure for greater volume, the Type 600 relays up to 50 scfm (1,400 Nl\/min) flow capacity to a final control element such as a valve actuator. The standard signal to output ratio is 1:1, however, the Type 600 is also available with an amplified ratio of 1:2, 1:3 and 1:6.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal\/Output Ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1:1, 1:2, 1:3, 1:6, 2:1, 3:1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eFlow Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e50 scfm (1415 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePort Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\" BSPP, 1\/2\" NPT, 1\/4\" BSPP, 1\/4\" NPT, 3\/8\" BSPP, 3\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal Port Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/4\" NPT, 1\/4\" BSP\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Port Size (optional)\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Flow Cv\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eSee PDF Sales Sheet\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSensitivity (depending on ratio) water column\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.25\" to 1.5\" (0.64 to 3.8 cm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eRatio Accuracy- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0% to 2.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eZero Error- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e2.0% to 3.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSupply Pressure Sensitivity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.1 to 0.6 psig for a change of 50 pis (3.5 bar) in supply pressure\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAir Consumption, Maximum depending on output range\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0 to 10 scfh (0.5 to 5.0 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Supply Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 psig (17 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Output Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 psig (10 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Signal Pressure depending on ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 to 25 psig (10.34 to 1.27 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAmbient Temperature Limits\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e-40° to 160°F (-40° to 71°C)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eWeight\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.4 lbs (635 gm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMounting Options\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003ePipe, panel, bracket\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eAluminium\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOther Internal Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eStainless steel, brass, plated steel, acetal, nitrile, polyester\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e429-842-292\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eTapped Exhaust: Yes\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster-Spec-Sheet1.pdf?v=1786493176\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"ControlAir","offers":[{"title":"Default Title","offer_id":44165546573902,"sku":"429-842-292","price":274.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster__31702.1784299774.1280.1280.jpg?v=1786659716"},{"product_id":"controlair-type-600-series-ratio-relay-volume-booster-429-842-302-600-bbez-ratio-1-2-1-4-npt-tapped-exhaust-fixed-negative-bias","title":"ControlAir Type 600 Series Ratio Relay Volume Booster, 429-842-302, 600-BBEZ, Ratio 1:2, 1\/4\" NPT, Tapped Exhaust, Fixed Negative Bias","description":"\u003ch2\u003eControlAir Type 600 Series Ratio Relay Volume Booster (600-BBEZ)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHigh Flow Capacity: Allows flows up to 50 SCFM (1,400 Nl\/min)\u003c\/li\u003e\n\u003cli\u003eMultiple Signal to Output Ratios: 1:1, 1:2, 1:3, 1:6, 2:1 and 3:1.\u003c\/li\u003e\n\u003cli\u003eStable Output: Venturi aspirator maintains output pressure under varying flow conditions.\u003c\/li\u003e\n\u003cli\u003eMultiple Port Sizes: Available in 1\/4\", 3\/8\" and 1\/2\" NPT\/BSPP.\u003c\/li\u003e\n\u003cli\u003eBalanced Supply Valve: Rolling diaphragm design makes unit insensitive to supply pressure variation.\u003c\/li\u003e\n\u003cli\u003eOptional Negative Bias: 4 psi (0.3 bar) negative bias option allows \"zero\" of I\/P's.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eMeet High Flow Requirements With A Low Flow Pneumatic Signal\u003c\/h2\u003e\u003cp\u003eThe Type 600 ratio relay volume booster is designed to use a pneumatic signal to produce an output pressure which has high flow capacity and can be amplified. This unit is most useful for systems requiring the conversion of a low flow control signal to the higher flow requirements of an operating system. Using an independent supply pressure for greater volume, the Type 600 relays up to 50 scfm (1,400 Nl\/min) flow capacity to a final control element such as a valve actuator. The standard signal to output ratio is 1:1, however, the Type 600 is also available with an amplified ratio of 1:2, 1:3 and 1:6.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal\/Output Ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1:1, 1:2, 1:3, 1:6, 2:1, 3:1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eFlow Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e50 scfm (1415 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePort Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\" BSPP, 1\/2\" NPT, 1\/4\" BSPP, 1\/4\" NPT, 3\/8\" BSPP, 3\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal Port Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/4\" NPT, 1\/4\" BSP\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Port Size (optional)\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Flow Cv\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eSee PDF Sales Sheet\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSensitivity (depending on ratio) water column\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.25\" to 1.5\" (0.64 to 3.8 cm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eRatio Accuracy- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0% to 2.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eZero Error- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e2.0% to 3.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSupply Pressure Sensitivity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.1 to 0.6 psig for a change of 50 pis (3.5 bar) in supply pressure\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAir Consumption, Maximum depending on output range\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0 to 10 scfh (0.5 to 5.0 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Supply Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 psig (17 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Output Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 psig (10 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Signal Pressure depending on ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 to 25 psig (10.34 to 1.27 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAmbient Temperature Limits\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e-40° to 160°F (-40° to 71°C)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eWeight\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.4 lbs (635 gm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMounting Options\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003ePipe, panel, bracket\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eAluminium\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOther Internal Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eStainless steel, brass, plated steel, acetal, nitrile, polyester\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e429-842-302\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eTapped Exhaust: Yes, Fixed Negative Bias: Yes\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster-Spec-Sheet1.pdf?v=1786493176\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"ControlAir","offers":[{"title":"Default Title","offer_id":44165547130958,"sku":"429-842-302","price":306.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster__56684.1784299908.1280.1280.jpg?v=1786659719"},{"product_id":"controlair-type-600-series-ratio-relay-volume-booster-429-842-234-600-bbu-ratio-1-2-1-4-npt-bsp-porting","title":"ControlAir Type 600 Series Ratio Relay Volume Booster, 429-842-234, 600-BBU, Ratio 1:2, 1\/4\" NPT, BSP Porting","description":"\u003ch2\u003eControlAir Type 600 Series Ratio Relay Volume Booster (600-BBU)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHigh Flow Capacity: Allows flows up to 50 SCFM (1,400 Nl\/min)\u003c\/li\u003e\n\u003cli\u003eMultiple Signal to Output Ratios: 1:1, 1:2, 1:3, 1:6, 2:1 and 3:1.\u003c\/li\u003e\n\u003cli\u003eStable Output: Venturi aspirator maintains output pressure under varying flow conditions.\u003c\/li\u003e\n\u003cli\u003eMultiple Port Sizes: Available in 1\/4\", 3\/8\" and 1\/2\" NPT\/BSPP.\u003c\/li\u003e\n\u003cli\u003eBalanced Supply Valve: Rolling diaphragm design makes unit insensitive to supply pressure variation.\u003c\/li\u003e\n\u003cli\u003eOptional Negative Bias: 4 psi (0.3 bar) negative bias option allows \"zero\" of I\/P's.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eMeet High Flow Requirements With A Low Flow Pneumatic Signal\u003c\/h2\u003e\u003cp\u003eThe Type 600 ratio relay volume booster is designed to use a pneumatic signal to produce an output pressure which has high flow capacity and can be amplified. This unit is most useful for systems requiring the conversion of a low flow control signal to the higher flow requirements of an operating system. Using an independent supply pressure for greater volume, the Type 600 relays up to 50 scfm (1,400 Nl\/min) flow capacity to a final control element such as a valve actuator. The standard signal to output ratio is 1:1, however, the Type 600 is also available with an amplified ratio of 1:2, 1:3 and 1:6.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal\/Output Ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1:1, 1:2, 1:3, 1:6, 2:1, 3:1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eFlow Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e50 scfm (1415 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePort Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\" BSPP, 1\/2\" NPT, 1\/4\" BSPP, 1\/4\" NPT, 3\/8\" BSPP, 3\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal Port Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/4\" NPT, 1\/4\" BSP\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Port Size (optional)\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Flow Cv\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eSee PDF Sales Sheet\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSensitivity (depending on ratio) water column\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.25\" to 1.5\" (0.64 to 3.8 cm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eRatio Accuracy- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0% to 2.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eZero Error- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e2.0% to 3.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSupply Pressure Sensitivity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.1 to 0.6 psig for a change of 50 pis (3.5 bar) in supply pressure\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAir Consumption, Maximum depending on output range\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0 to 10 scfh (0.5 to 5.0 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Supply Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 psig (17 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Output Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 psig (10 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Signal Pressure depending on ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 to 25 psig (10.34 to 1.27 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAmbient Temperature Limits\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e-40° to 160°F (-40° to 71°C)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eWeight\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.4 lbs (635 gm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMounting Options\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003ePipe, panel, bracket\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eAluminium\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOther Internal Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eStainless steel, brass, plated steel, acetal, nitrile, polyester\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e429-842-234\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eBSP Porting: Yes\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster-Spec-Sheet1.pdf?v=1786493176\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"ControlAir","offers":[{"title":"Default Title","offer_id":44165547753550,"sku":"429-842-234","price":251.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster__81138.1784299775.1280.1280.jpg?v=1786659722"},{"product_id":"controlair-type-600-series-ratio-relay-volume-booster-429-842-255-600-bbz-ratio-1-2-1-4-npt-fixed-negative-bias","title":"ControlAir Type 600 Series Ratio Relay Volume Booster, 429-842-255, 600-BBZ, Ratio 1:2, 1\/4\" NPT, Fixed Negative Bias","description":"\u003ch2\u003eControlAir Type 600 Series Ratio Relay Volume Booster (600-BBZ)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHigh Flow Capacity: Allows flows up to 50 SCFM (1,400 Nl\/min)\u003c\/li\u003e\n\u003cli\u003eMultiple Signal to Output Ratios: 1:1, 1:2, 1:3, 1:6, 2:1 and 3:1.\u003c\/li\u003e\n\u003cli\u003eStable Output: Venturi aspirator maintains output pressure under varying flow conditions.\u003c\/li\u003e\n\u003cli\u003eMultiple Port Sizes: Available in 1\/4\", 3\/8\" and 1\/2\" NPT\/BSPP.\u003c\/li\u003e\n\u003cli\u003eBalanced Supply Valve: Rolling diaphragm design makes unit insensitive to supply pressure variation.\u003c\/li\u003e\n\u003cli\u003eOptional Negative Bias: 4 psi (0.3 bar) negative bias option allows \"zero\" of I\/P's.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eMeet High Flow Requirements With A Low Flow Pneumatic Signal\u003c\/h2\u003e\u003cp\u003eThe Type 600 ratio relay volume booster is designed to use a pneumatic signal to produce an output pressure which has high flow capacity and can be amplified. This unit is most useful for systems requiring the conversion of a low flow control signal to the higher flow requirements of an operating system. Using an independent supply pressure for greater volume, the Type 600 relays up to 50 scfm (1,400 Nl\/min) flow capacity to a final control element such as a valve actuator. The standard signal to output ratio is 1:1, however, the Type 600 is also available with an amplified ratio of 1:2, 1:3 and 1:6.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal\/Output Ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1:1, 1:2, 1:3, 1:6, 2:1, 3:1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eFlow Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e50 scfm (1415 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePort Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\" BSPP, 1\/2\" NPT, 1\/4\" BSPP, 1\/4\" NPT, 3\/8\" BSPP, 3\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal Port Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/4\" NPT, 1\/4\" BSP\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Port Size (optional)\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Flow Cv\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eSee PDF Sales Sheet\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSensitivity (depending on ratio) water column\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.25\" to 1.5\" (0.64 to 3.8 cm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eRatio Accuracy- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0% to 2.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eZero Error- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e2.0% to 3.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSupply Pressure Sensitivity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.1 to 0.6 psig for a change of 50 pis (3.5 bar) in supply pressure\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAir Consumption, Maximum depending on output range\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0 to 10 scfh (0.5 to 5.0 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Supply Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 psig (17 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Output Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 psig (10 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Signal Pressure depending on ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 to 25 psig (10.34 to 1.27 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAmbient Temperature Limits\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e-40° to 160°F (-40° to 71°C)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eWeight\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.4 lbs (635 gm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMounting Options\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003ePipe, panel, bracket\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eAluminium\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOther Internal Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eStainless steel, brass, plated steel, acetal, nitrile, polyester\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e429-842-255\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eFixed Negative Bias: Yes\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster-Spec-Sheet1.pdf?v=1786493176\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"ControlAir","offers":[{"title":"Default Title","offer_id":44165547982926,"sku":"429-842-255","price":283.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster__43834.1784299846.1280.1280.jpg?v=1786659724"},{"product_id":"controlair-type-600-series-ratio-relay-volume-booster-429-843-001-600-bc-ratio-1-3-1-4-npt","title":"ControlAir Type 600 Series Ratio Relay Volume Booster, 429-843-001, 600-BC, Ratio 1:3, 1\/4\" NPT","description":"\u003ch2\u003eControlAir Type 600 Series Ratio Relay Volume Booster (600-BC)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHigh Flow Capacity: Allows flows up to 50 SCFM (1,400 Nl\/min)\u003c\/li\u003e\n\u003cli\u003eMultiple Signal to Output Ratios: 1:1, 1:2, 1:3, 1:6, 2:1 and 3:1.\u003c\/li\u003e\n\u003cli\u003eStable Output: Venturi aspirator maintains output pressure under varying flow conditions.\u003c\/li\u003e\n\u003cli\u003eMultiple Port Sizes: Available in 1\/4\", 3\/8\" and 1\/2\" NPT\/BSPP.\u003c\/li\u003e\n\u003cli\u003eBalanced Supply Valve: Rolling diaphragm design makes unit insensitive to supply pressure variation.\u003c\/li\u003e\n\u003cli\u003eOptional Negative Bias: 4 psi (0.3 bar) negative bias option allows \"zero\" of I\/P's.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eMeet High Flow Requirements With A Low Flow Pneumatic Signal\u003c\/h2\u003e\u003cp\u003eThe Type 600 ratio relay volume booster is designed to use a pneumatic signal to produce an output pressure which has high flow capacity and can be amplified. This unit is most useful for systems requiring the conversion of a low flow control signal to the higher flow requirements of an operating system. Using an independent supply pressure for greater volume, the Type 600 relays up to 50 scfm (1,400 Nl\/min) flow capacity to a final control element such as a valve actuator. The standard signal to output ratio is 1:1, however, the Type 600 is also available with an amplified ratio of 1:2, 1:3 and 1:6.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal\/Output Ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1:1, 1:2, 1:3, 1:6, 2:1, 3:1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eFlow Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e50 scfm (1415 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePort Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\" BSPP, 1\/2\" NPT, 1\/4\" BSPP, 1\/4\" NPT, 3\/8\" BSPP, 3\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal Port Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/4\" NPT, 1\/4\" BSP\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Port Size (optional)\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Flow Cv\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eSee PDF Sales Sheet\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSensitivity (depending on ratio) water column\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.25\" to 1.5\" (0.64 to 3.8 cm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eRatio Accuracy- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0% to 2.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eZero Error- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e2.0% to 3.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSupply Pressure Sensitivity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.1 to 0.6 psig for a change of 50 pis (3.5 bar) in supply pressure\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAir Consumption, Maximum depending on output range\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0 to 10 scfh (0.5 to 5.0 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Supply Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 psig (17 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Output Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 psig (10 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Signal Pressure depending on ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 to 25 psig (10.34 to 1.27 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAmbient Temperature Limits\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e-40° to 160°F (-40° to 71°C)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eWeight\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.4 lbs (635 gm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMounting Options\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003ePipe, panel, bracket\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eAluminium\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOther Internal Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eStainless steel, brass, plated steel, acetal, nitrile, polyester\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e429-843-001\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster-Spec-Sheet1.pdf?v=1786493176\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"ControlAir","offers":[{"title":"Default Title","offer_id":44165548507214,"sku":"429-843-001","price":251.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster__90883.1784299736.1280.1280.jpg?v=1786659727"},{"product_id":"controlair-type-600-series-ratio-relay-volume-booster-429-843-006-600-bce-ratio-1-3-1-4-npt-tapped-exhaust","title":"ControlAir Type 600 Series Ratio Relay Volume Booster, 429-843-006, 600-BCE, Ratio 1:3, 1\/4\" NPT, Tapped Exhaust","description":"\u003ch2\u003eControlAir Type 600 Series Ratio Relay Volume Booster (600-BCE)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHigh Flow Capacity: Allows flows up to 50 SCFM (1,400 Nl\/min)\u003c\/li\u003e\n\u003cli\u003eMultiple Signal to Output Ratios: 1:1, 1:2, 1:3, 1:6, 2:1 and 3:1.\u003c\/li\u003e\n\u003cli\u003eStable Output: Venturi aspirator maintains output pressure under varying flow conditions.\u003c\/li\u003e\n\u003cli\u003eMultiple Port Sizes: Available in 1\/4\", 3\/8\" and 1\/2\" NPT\/BSPP.\u003c\/li\u003e\n\u003cli\u003eBalanced Supply Valve: Rolling diaphragm design makes unit insensitive to supply pressure variation.\u003c\/li\u003e\n\u003cli\u003eOptional Negative Bias: 4 psi (0.3 bar) negative bias option allows \"zero\" of I\/P's.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eMeet High Flow Requirements With A Low Flow Pneumatic Signal\u003c\/h2\u003e\u003cp\u003eThe Type 600 ratio relay volume booster is designed to use a pneumatic signal to produce an output pressure which has high flow capacity and can be amplified. This unit is most useful for systems requiring the conversion of a low flow control signal to the higher flow requirements of an operating system. Using an independent supply pressure for greater volume, the Type 600 relays up to 50 scfm (1,400 Nl\/min) flow capacity to a final control element such as a valve actuator. The standard signal to output ratio is 1:1, however, the Type 600 is also available with an amplified ratio of 1:2, 1:3 and 1:6.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal\/Output Ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1:1, 1:2, 1:3, 1:6, 2:1, 3:1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eFlow Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e50 scfm (1415 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePort Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\" BSPP, 1\/2\" NPT, 1\/4\" BSPP, 1\/4\" NPT, 3\/8\" BSPP, 3\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal Port Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/4\" NPT, 1\/4\" BSP\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Port Size (optional)\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Flow Cv\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eSee PDF Sales Sheet\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSensitivity (depending on ratio) water column\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.25\" to 1.5\" (0.64 to 3.8 cm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eRatio Accuracy- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0% to 2.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eZero Error- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e2.0% to 3.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSupply Pressure Sensitivity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.1 to 0.6 psig for a change of 50 pis (3.5 bar) in supply pressure\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAir Consumption, Maximum depending on output range\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0 to 10 scfh (0.5 to 5.0 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Supply Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 psig (17 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Output Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 psig (10 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Signal Pressure depending on ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 to 25 psig (10.34 to 1.27 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAmbient Temperature Limits\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e-40° to 160°F (-40° to 71°C)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eWeight\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.4 lbs (635 gm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMounting Options\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003ePipe, panel, bracket\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eAluminium\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOther Internal Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eStainless steel, brass, plated steel, acetal, nitrile, polyester\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e429-843-006\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eTapped Exhaust: Yes\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster-Spec-Sheet1.pdf?v=1786493176\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"ControlAir","offers":[{"title":"Default Title","offer_id":44165549031502,"sku":"429-843-006","price":274.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster__10944.1784299775.1280.1280.jpg?v=1786659730"},{"product_id":"controlair-type-600-series-ratio-relay-volume-booster-429-843-021-600-bcex-ratio-1-3-1-4-npt-tapped-exhaust-atex-2014-34-eu","title":"ControlAir Type 600 Series Ratio Relay Volume Booster, 429-843-021, 600-BCEX, Ratio 1:3, 1\/4\" NPT, Tapped Exhaust, ATEX 2014\/34\/EU","description":"\u003ch2\u003eControlAir Type 600 Series Ratio Relay Volume Booster (600-BCEX)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHigh Flow Capacity: Allows flows up to 50 SCFM (1,400 Nl\/min)\u003c\/li\u003e\n\u003cli\u003eMultiple Signal to Output Ratios: 1:1, 1:2, 1:3, 1:6, 2:1 and 3:1.\u003c\/li\u003e\n\u003cli\u003eStable Output: Venturi aspirator maintains output pressure under varying flow conditions.\u003c\/li\u003e\n\u003cli\u003eMultiple Port Sizes: Available in 1\/4\", 3\/8\" and 1\/2\" NPT\/BSPP.\u003c\/li\u003e\n\u003cli\u003eBalanced Supply Valve: Rolling diaphragm design makes unit insensitive to supply pressure variation.\u003c\/li\u003e\n\u003cli\u003eOptional Negative Bias: 4 psi (0.3 bar) negative bias option allows \"zero\" of I\/P's.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eMeet High Flow Requirements With A Low Flow Pneumatic Signal\u003c\/h2\u003e\u003cp\u003eThe Type 600 ratio relay volume booster is designed to use a pneumatic signal to produce an output pressure which has high flow capacity and can be amplified. This unit is most useful for systems requiring the conversion of a low flow control signal to the higher flow requirements of an operating system. Using an independent supply pressure for greater volume, the Type 600 relays up to 50 scfm (1,400 Nl\/min) flow capacity to a final control element such as a valve actuator. The standard signal to output ratio is 1:1, however, the Type 600 is also available with an amplified ratio of 1:2, 1:3 and 1:6.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal\/Output Ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1:1, 1:2, 1:3, 1:6, 2:1, 3:1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eFlow Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e50 scfm (1415 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePort Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\" BSPP, 1\/2\" NPT, 1\/4\" BSPP, 1\/4\" NPT, 3\/8\" BSPP, 3\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal Port Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/4\" NPT, 1\/4\" BSP\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Port Size (optional)\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Flow Cv\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eSee PDF Sales Sheet\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSensitivity (depending on ratio) water column\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.25\" to 1.5\" (0.64 to 3.8 cm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eRatio Accuracy- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0% to 2.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eZero Error- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e2.0% to 3.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSupply Pressure Sensitivity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.1 to 0.6 psig for a change of 50 pis (3.5 bar) in supply pressure\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAir Consumption, Maximum depending on output range\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0 to 10 scfh (0.5 to 5.0 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Supply Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 psig (17 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Output Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 psig (10 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Signal Pressure depending on ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 to 25 psig (10.34 to 1.27 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAmbient Temperature Limits\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e-40° to 160°F (-40° to 71°C)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eWeight\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.4 lbs (635 gm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMounting Options\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003ePipe, panel, bracket\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eAluminium\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOther Internal Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eStainless steel, brass, plated steel, acetal, nitrile, polyester\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e429-843-021\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eTapped Exhaust: Yes, ATEX 2014\/34\/EU: Yes\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster-Spec-Sheet1.pdf?v=1786493176\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"ControlAir","offers":[{"title":"Default Title","offer_id":44165549654094,"sku":"429-843-021","price":281.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster__61279.1784300252.1280.1280.jpg?v=1786659732"},{"product_id":"controlair-type-600-series-ratio-relay-volume-booster-429-843-007-600-bcez-ratio-1-3-1-4-npt-tapped-exhaust-fixed-negative-bias","title":"ControlAir Type 600 Series Ratio Relay Volume Booster, 429-843-007, 600-BCEZ, Ratio 1:3, 1\/4\" NPT, Tapped Exhaust, Fixed Negative Bias","description":"\u003ch2\u003eControlAir Type 600 Series Ratio Relay Volume Booster (600-BCEZ)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHigh Flow Capacity: Allows flows up to 50 SCFM (1,400 Nl\/min)\u003c\/li\u003e\n\u003cli\u003eMultiple Signal to Output Ratios: 1:1, 1:2, 1:3, 1:6, 2:1 and 3:1.\u003c\/li\u003e\n\u003cli\u003eStable Output: Venturi aspirator maintains output pressure under varying flow conditions.\u003c\/li\u003e\n\u003cli\u003eMultiple Port Sizes: Available in 1\/4\", 3\/8\" and 1\/2\" NPT\/BSPP.\u003c\/li\u003e\n\u003cli\u003eBalanced Supply Valve: Rolling diaphragm design makes unit insensitive to supply pressure variation.\u003c\/li\u003e\n\u003cli\u003eOptional Negative Bias: 4 psi (0.3 bar) negative bias option allows \"zero\" of I\/P's.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eMeet High Flow Requirements With A Low Flow Pneumatic Signal\u003c\/h2\u003e\u003cp\u003eThe Type 600 ratio relay volume booster is designed to use a pneumatic signal to produce an output pressure which has high flow capacity and can be amplified. This unit is most useful for systems requiring the conversion of a low flow control signal to the higher flow requirements of an operating system. Using an independent supply pressure for greater volume, the Type 600 relays up to 50 scfm (1,400 Nl\/min) flow capacity to a final control element such as a valve actuator. The standard signal to output ratio is 1:1, however, the Type 600 is also available with an amplified ratio of 1:2, 1:3 and 1:6.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal\/Output Ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1:1, 1:2, 1:3, 1:6, 2:1, 3:1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eFlow Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e50 scfm (1415 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePort Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\" BSPP, 1\/2\" NPT, 1\/4\" BSPP, 1\/4\" NPT, 3\/8\" BSPP, 3\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal Port Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/4\" NPT, 1\/4\" BSP\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Port Size (optional)\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Flow Cv\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eSee PDF Sales Sheet\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSensitivity (depending on ratio) water column\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.25\" to 1.5\" (0.64 to 3.8 cm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eRatio Accuracy- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0% to 2.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eZero Error- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e2.0% to 3.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSupply Pressure Sensitivity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.1 to 0.6 psig for a change of 50 pis (3.5 bar) in supply pressure\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAir Consumption, Maximum depending on output range\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0 to 10 scfh (0.5 to 5.0 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Supply Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 psig (17 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Output Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 psig (10 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Signal Pressure depending on ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 to 25 psig (10.34 to 1.27 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAmbient Temperature Limits\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e-40° to 160°F (-40° to 71°C)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eWeight\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.4 lbs (635 gm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMounting Options\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003ePipe, panel, bracket\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eAluminium\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOther Internal Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eStainless steel, brass, plated steel, acetal, nitrile, polyester\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e429-843-007\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eTapped Exhaust: Yes, Fixed Negative Bias: Yes\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster-Spec-Sheet1.pdf?v=1786493176\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"ControlAir","offers":[{"title":"Default Title","offer_id":44165550211150,"sku":"429-843-007","price":306.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster__24006.1784299908.1280.1280.jpg?v=1786659735"},{"product_id":"controlair-type-600-series-ratio-relay-volume-booster-429-843-013-600-bcu-ratio-1-3-1-4-npt-bsp-porting","title":"ControlAir Type 600 Series Ratio Relay Volume Booster, 429-843-013, 600-BCU, Ratio 1:3, 1\/4\" NPT, BSP Porting","description":"\u003ch2\u003eControlAir Type 600 Series Ratio Relay Volume Booster (600-BCU)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHigh Flow Capacity: Allows flows up to 50 SCFM (1,400 Nl\/min)\u003c\/li\u003e\n\u003cli\u003eMultiple Signal to Output Ratios: 1:1, 1:2, 1:3, 1:6, 2:1 and 3:1.\u003c\/li\u003e\n\u003cli\u003eStable Output: Venturi aspirator maintains output pressure under varying flow conditions.\u003c\/li\u003e\n\u003cli\u003eMultiple Port Sizes: Available in 1\/4\", 3\/8\" and 1\/2\" NPT\/BSPP.\u003c\/li\u003e\n\u003cli\u003eBalanced Supply Valve: Rolling diaphragm design makes unit insensitive to supply pressure variation.\u003c\/li\u003e\n\u003cli\u003eOptional Negative Bias: 4 psi (0.3 bar) negative bias option allows \"zero\" of I\/P's.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eMeet High Flow Requirements With A Low Flow Pneumatic Signal\u003c\/h2\u003e\u003cp\u003eThe Type 600 ratio relay volume booster is designed to use a pneumatic signal to produce an output pressure which has high flow capacity and can be amplified. This unit is most useful for systems requiring the conversion of a low flow control signal to the higher flow requirements of an operating system. Using an independent supply pressure for greater volume, the Type 600 relays up to 50 scfm (1,400 Nl\/min) flow capacity to a final control element such as a valve actuator. The standard signal to output ratio is 1:1, however, the Type 600 is also available with an amplified ratio of 1:2, 1:3 and 1:6.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal\/Output Ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1:1, 1:2, 1:3, 1:6, 2:1, 3:1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eFlow Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e50 scfm (1415 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePort Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\" BSPP, 1\/2\" NPT, 1\/4\" BSPP, 1\/4\" NPT, 3\/8\" BSPP, 3\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal Port Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/4\" NPT, 1\/4\" BSP\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Port Size (optional)\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Flow Cv\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eSee PDF Sales Sheet\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSensitivity (depending on ratio) water column\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.25\" to 1.5\" (0.64 to 3.8 cm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eRatio Accuracy- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0% to 2.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eZero Error- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e2.0% to 3.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSupply Pressure Sensitivity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.1 to 0.6 psig for a change of 50 pis (3.5 bar) in supply pressure\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAir Consumption, Maximum depending on output range\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0 to 10 scfh (0.5 to 5.0 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Supply Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 psig (17 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Output Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 psig (10 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Signal Pressure depending on ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 to 25 psig (10.34 to 1.27 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAmbient Temperature Limits\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e-40° to 160°F (-40° to 71°C)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eWeight\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.4 lbs (635 gm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMounting Options\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003ePipe, panel, bracket\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eAluminium\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOther Internal Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eStainless steel, brass, plated steel, acetal, nitrile, polyester\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e429-843-013\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eBSP Porting: Yes\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster-Spec-Sheet1.pdf?v=1786493176\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"ControlAir","offers":[{"title":"Default Title","offer_id":44165550768206,"sku":"429-843-013","price":251.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster__98377.1784299775.1280.1280.jpg?v=1786659737"},{"product_id":"controlair-type-600-series-ratio-relay-volume-booster-429-843-003-600-bcz-ratio-1-3-1-4-npt-fixed-negative-bias","title":"ControlAir Type 600 Series Ratio Relay Volume Booster, 429-843-003, 600-BCZ, Ratio 1:3, 1\/4\" NPT, Fixed Negative Bias","description":"\u003ch2\u003eControlAir Type 600 Series Ratio Relay Volume Booster (600-BCZ)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHigh Flow Capacity: Allows flows up to 50 SCFM (1,400 Nl\/min)\u003c\/li\u003e\n\u003cli\u003eMultiple Signal to Output Ratios: 1:1, 1:2, 1:3, 1:6, 2:1 and 3:1.\u003c\/li\u003e\n\u003cli\u003eStable Output: Venturi aspirator maintains output pressure under varying flow conditions.\u003c\/li\u003e\n\u003cli\u003eMultiple Port Sizes: Available in 1\/4\", 3\/8\" and 1\/2\" NPT\/BSPP.\u003c\/li\u003e\n\u003cli\u003eBalanced Supply Valve: Rolling diaphragm design makes unit insensitive to supply pressure variation.\u003c\/li\u003e\n\u003cli\u003eOptional Negative Bias: 4 psi (0.3 bar) negative bias option allows \"zero\" of I\/P's.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eMeet High Flow Requirements With A Low Flow Pneumatic Signal\u003c\/h2\u003e\u003cp\u003eThe Type 600 ratio relay volume booster is designed to use a pneumatic signal to produce an output pressure which has high flow capacity and can be amplified. This unit is most useful for systems requiring the conversion of a low flow control signal to the higher flow requirements of an operating system. Using an independent supply pressure for greater volume, the Type 600 relays up to 50 scfm (1,400 Nl\/min) flow capacity to a final control element such as a valve actuator. The standard signal to output ratio is 1:1, however, the Type 600 is also available with an amplified ratio of 1:2, 1:3 and 1:6.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal\/Output Ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1:1, 1:2, 1:3, 1:6, 2:1, 3:1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eFlow Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e50 scfm (1415 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePort Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\" BSPP, 1\/2\" NPT, 1\/4\" BSPP, 1\/4\" NPT, 3\/8\" BSPP, 3\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal Port Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/4\" NPT, 1\/4\" BSP\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Port Size (optional)\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Flow Cv\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eSee PDF Sales Sheet\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSensitivity (depending on ratio) water column\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.25\" to 1.5\" (0.64 to 3.8 cm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eRatio Accuracy- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0% to 2.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eZero Error- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e2.0% to 3.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSupply Pressure Sensitivity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.1 to 0.6 psig for a change of 50 pis (3.5 bar) in supply pressure\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAir Consumption, Maximum depending on output range\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0 to 10 scfh (0.5 to 5.0 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Supply Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 psig (17 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Output Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 psig (10 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Signal Pressure depending on ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 to 25 psig (10.34 to 1.27 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAmbient Temperature Limits\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e-40° to 160°F (-40° to 71°C)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eWeight\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.4 lbs (635 gm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMounting Options\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003ePipe, panel, bracket\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eAluminium\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOther Internal Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eStainless steel, brass, plated steel, acetal, nitrile, polyester\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e429-843-003\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eFixed Negative Bias: Yes\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster-Spec-Sheet1.pdf?v=1786493176\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"ControlAir","offers":[{"title":"Default Title","offer_id":44165551325262,"sku":"429-843-003","price":283.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster__27875.1784299847.1280.1280.jpg?v=1786659740"},{"product_id":"controlair-type-600-series-ratio-relay-volume-booster-429-846-001-600-bd-ratio-1-6-1-4-npt","title":"ControlAir Type 600 Series Ratio Relay Volume Booster, 429-846-001, 600-BD, Ratio 1:6, 1\/4\" NPT","description":"\u003ch2\u003eControlAir Type 600 Series Ratio Relay Volume Booster (600-BD)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHigh Flow Capacity: Allows flows up to 50 SCFM (1,400 Nl\/min)\u003c\/li\u003e\n\u003cli\u003eMultiple Signal to Output Ratios: 1:1, 1:2, 1:3, 1:6, 2:1 and 3:1.\u003c\/li\u003e\n\u003cli\u003eStable Output: Venturi aspirator maintains output pressure under varying flow conditions.\u003c\/li\u003e\n\u003cli\u003eMultiple Port Sizes: Available in 1\/4\", 3\/8\" and 1\/2\" NPT\/BSPP.\u003c\/li\u003e\n\u003cli\u003eBalanced Supply Valve: Rolling diaphragm design makes unit insensitive to supply pressure variation.\u003c\/li\u003e\n\u003cli\u003eOptional Negative Bias: 4 psi (0.3 bar) negative bias option allows \"zero\" of I\/P's.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eMeet High Flow Requirements With A Low Flow Pneumatic Signal\u003c\/h2\u003e\u003cp\u003eThe Type 600 ratio relay volume booster is designed to use a pneumatic signal to produce an output pressure which has high flow capacity and can be amplified. This unit is most useful for systems requiring the conversion of a low flow control signal to the higher flow requirements of an operating system. Using an independent supply pressure for greater volume, the Type 600 relays up to 50 scfm (1,400 Nl\/min) flow capacity to a final control element such as a valve actuator. The standard signal to output ratio is 1:1, however, the Type 600 is also available with an amplified ratio of 1:2, 1:3 and 1:6.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal\/Output Ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1:1, 1:2, 1:3, 1:6, 2:1, 3:1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eFlow Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e50 scfm (1415 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePort Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\" BSPP, 1\/2\" NPT, 1\/4\" BSPP, 1\/4\" NPT, 3\/8\" BSPP, 3\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal Port Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/4\" NPT, 1\/4\" BSP\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Port Size (optional)\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Flow Cv\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eSee PDF Sales Sheet\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSensitivity (depending on ratio) water column\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.25\" to 1.5\" (0.64 to 3.8 cm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eRatio Accuracy- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0% to 2.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eZero Error- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e2.0% to 3.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSupply Pressure Sensitivity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.1 to 0.6 psig for a change of 50 pis (3.5 bar) in supply pressure\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAir Consumption, Maximum depending on output range\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0 to 10 scfh (0.5 to 5.0 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Supply Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 psig (17 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Output Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 psig (10 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Signal Pressure depending on ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 to 25 psig (10.34 to 1.27 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAmbient Temperature Limits\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e-40° to 160°F (-40° to 71°C)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eWeight\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.4 lbs (635 gm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMounting Options\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003ePipe, panel, bracket\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eAluminium\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOther Internal Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eStainless steel, brass, plated steel, acetal, nitrile, polyester\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e429-846-001\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster-Spec-Sheet1.pdf?v=1786493176\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"ControlAir","offers":[{"title":"Default Title","offer_id":44165551882318,"sku":"429-846-001","price":251.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster__16995.1784299737.1280.1280.jpg?v=1786659743"},{"product_id":"controlair-type-600-series-ratio-relay-volume-booster-429-846-008-600-bde-ratio-1-6-1-4-npt-tapped-exhaust","title":"ControlAir Type 600 Series Ratio Relay Volume Booster, 429-846-008, 600-BDE, Ratio 1:6, 1\/4\" NPT, Tapped Exhaust","description":"\u003ch2\u003eControlAir Type 600 Series Ratio Relay Volume Booster (600-BDE)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHigh Flow Capacity: Allows flows up to 50 SCFM (1,400 Nl\/min)\u003c\/li\u003e\n\u003cli\u003eMultiple Signal to Output Ratios: 1:1, 1:2, 1:3, 1:6, 2:1 and 3:1.\u003c\/li\u003e\n\u003cli\u003eStable Output: Venturi aspirator maintains output pressure under varying flow conditions.\u003c\/li\u003e\n\u003cli\u003eMultiple Port Sizes: Available in 1\/4\", 3\/8\" and 1\/2\" NPT\/BSPP.\u003c\/li\u003e\n\u003cli\u003eBalanced Supply Valve: Rolling diaphragm design makes unit insensitive to supply pressure variation.\u003c\/li\u003e\n\u003cli\u003eOptional Negative Bias: 4 psi (0.3 bar) negative bias option allows \"zero\" of I\/P's.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eMeet High Flow Requirements With A Low Flow Pneumatic Signal\u003c\/h2\u003e\u003cp\u003eThe Type 600 ratio relay volume booster is designed to use a pneumatic signal to produce an output pressure which has high flow capacity and can be amplified. This unit is most useful for systems requiring the conversion of a low flow control signal to the higher flow requirements of an operating system. Using an independent supply pressure for greater volume, the Type 600 relays up to 50 scfm (1,400 Nl\/min) flow capacity to a final control element such as a valve actuator. The standard signal to output ratio is 1:1, however, the Type 600 is also available with an amplified ratio of 1:2, 1:3 and 1:6.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal\/Output Ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1:1, 1:2, 1:3, 1:6, 2:1, 3:1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eFlow Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e50 scfm (1415 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePort Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\" BSPP, 1\/2\" NPT, 1\/4\" BSPP, 1\/4\" NPT, 3\/8\" BSPP, 3\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal Port Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/4\" NPT, 1\/4\" BSP\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Port Size (optional)\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Flow Cv\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eSee PDF Sales Sheet\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSensitivity (depending on ratio) water column\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.25\" to 1.5\" (0.64 to 3.8 cm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eRatio Accuracy- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0% to 2.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eZero Error- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e2.0% to 3.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSupply Pressure Sensitivity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.1 to 0.6 psig for a change of 50 pis (3.5 bar) in supply pressure\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAir Consumption, Maximum depending on output range\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0 to 10 scfh (0.5 to 5.0 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Supply Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 psig (17 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Output Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 psig (10 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Signal Pressure depending on ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 to 25 psig (10.34 to 1.27 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAmbient Temperature Limits\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e-40° to 160°F (-40° to 71°C)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eWeight\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.4 lbs (635 gm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMounting Options\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003ePipe, panel, bracket\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eAluminium\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOther Internal Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eStainless steel, brass, plated steel, acetal, nitrile, polyester\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e429-846-008\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eTapped Exhaust: Yes\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster-Spec-Sheet1.pdf?v=1786493176\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"ControlAir","offers":[{"title":"Default Title","offer_id":44165552439374,"sku":"429-846-008","price":274.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster__83869.1784299776.1280.1280.jpg?v=1786659745"},{"product_id":"controlair-type-600-series-ratio-relay-volume-booster-429-846-010-600-bdez-ratio-1-6-1-4-npt-tapped-exhaust-fixed-negative-bias","title":"ControlAir Type 600 Series Ratio Relay Volume Booster, 429-846-010, 600-BDEZ, Ratio 1:6, 1\/4\" NPT, Tapped Exhaust, Fixed Negative Bias","description":"\u003ch2\u003eControlAir Type 600 Series Ratio Relay Volume Booster (600-BDEZ)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHigh Flow Capacity: Allows flows up to 50 SCFM (1,400 Nl\/min)\u003c\/li\u003e\n\u003cli\u003eMultiple Signal to Output Ratios: 1:1, 1:2, 1:3, 1:6, 2:1 and 3:1.\u003c\/li\u003e\n\u003cli\u003eStable Output: Venturi aspirator maintains output pressure under varying flow conditions.\u003c\/li\u003e\n\u003cli\u003eMultiple Port Sizes: Available in 1\/4\", 3\/8\" and 1\/2\" NPT\/BSPP.\u003c\/li\u003e\n\u003cli\u003eBalanced Supply Valve: Rolling diaphragm design makes unit insensitive to supply pressure variation.\u003c\/li\u003e\n\u003cli\u003eOptional Negative Bias: 4 psi (0.3 bar) negative bias option allows \"zero\" of I\/P's.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eMeet High Flow Requirements With A Low Flow Pneumatic Signal\u003c\/h2\u003e\u003cp\u003eThe Type 600 ratio relay volume booster is designed to use a pneumatic signal to produce an output pressure which has high flow capacity and can be amplified. This unit is most useful for systems requiring the conversion of a low flow control signal to the higher flow requirements of an operating system. Using an independent supply pressure for greater volume, the Type 600 relays up to 50 scfm (1,400 Nl\/min) flow capacity to a final control element such as a valve actuator. The standard signal to output ratio is 1:1, however, the Type 600 is also available with an amplified ratio of 1:2, 1:3 and 1:6.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal\/Output Ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1:1, 1:2, 1:3, 1:6, 2:1, 3:1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eFlow Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e50 scfm (1415 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePort Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\" BSPP, 1\/2\" NPT, 1\/4\" BSPP, 1\/4\" NPT, 3\/8\" BSPP, 3\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal Port Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/4\" NPT, 1\/4\" BSP\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Port Size (optional)\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Flow Cv\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eSee PDF Sales Sheet\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSensitivity (depending on ratio) water column\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.25\" to 1.5\" (0.64 to 3.8 cm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eRatio Accuracy- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0% to 2.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eZero Error- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e2.0% to 3.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSupply Pressure Sensitivity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.1 to 0.6 psig for a change of 50 pis (3.5 bar) in supply pressure\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAir Consumption, Maximum depending on output range\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0 to 10 scfh (0.5 to 5.0 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Supply Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 psig (17 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Output Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 psig (10 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Signal Pressure depending on ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 to 25 psig (10.34 to 1.27 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAmbient Temperature Limits\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e-40° to 160°F (-40° to 71°C)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eWeight\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.4 lbs (635 gm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMounting Options\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003ePipe, panel, bracket\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eAluminium\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOther Internal Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eStainless steel, brass, plated steel, acetal, nitrile, polyester\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e429-846-010\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eTapped Exhaust: Yes, Fixed Negative Bias: Yes\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster-Spec-Sheet1.pdf?v=1786493176\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"ControlAir","offers":[{"title":"Default Title","offer_id":44165552996430,"sku":"429-846-010","price":306.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster__69107.1784299908.1280.1280.jpg?v=1786659748"},{"product_id":"controlair-type-600-series-ratio-relay-volume-booster-429-846-013-600-bdu-ratio-1-6-1-4-npt-bsp-porting","title":"ControlAir Type 600 Series Ratio Relay Volume Booster, 429-846-013, 600-BDU, Ratio 1:6, 1\/4\" NPT, BSP Porting","description":"\u003ch2\u003eControlAir Type 600 Series Ratio Relay Volume Booster (600-BDU)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHigh Flow Capacity: Allows flows up to 50 SCFM (1,400 Nl\/min)\u003c\/li\u003e\n\u003cli\u003eMultiple Signal to Output Ratios: 1:1, 1:2, 1:3, 1:6, 2:1 and 3:1.\u003c\/li\u003e\n\u003cli\u003eStable Output: Venturi aspirator maintains output pressure under varying flow conditions.\u003c\/li\u003e\n\u003cli\u003eMultiple Port Sizes: Available in 1\/4\", 3\/8\" and 1\/2\" NPT\/BSPP.\u003c\/li\u003e\n\u003cli\u003eBalanced Supply Valve: Rolling diaphragm design makes unit insensitive to supply pressure variation.\u003c\/li\u003e\n\u003cli\u003eOptional Negative Bias: 4 psi (0.3 bar) negative bias option allows \"zero\" of I\/P's.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eMeet High Flow Requirements With A Low Flow Pneumatic Signal\u003c\/h2\u003e\u003cp\u003eThe Type 600 ratio relay volume booster is designed to use a pneumatic signal to produce an output pressure which has high flow capacity and can be amplified. This unit is most useful for systems requiring the conversion of a low flow control signal to the higher flow requirements of an operating system. Using an independent supply pressure for greater volume, the Type 600 relays up to 50 scfm (1,400 Nl\/min) flow capacity to a final control element such as a valve actuator. The standard signal to output ratio is 1:1, however, the Type 600 is also available with an amplified ratio of 1:2, 1:3 and 1:6.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal\/Output Ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1:1, 1:2, 1:3, 1:6, 2:1, 3:1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eFlow Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e50 scfm (1415 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePort Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\" BSPP, 1\/2\" NPT, 1\/4\" BSPP, 1\/4\" NPT, 3\/8\" BSPP, 3\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal Port Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/4\" NPT, 1\/4\" BSP\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Port Size (optional)\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Flow Cv\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eSee PDF Sales Sheet\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSensitivity (depending on ratio) water column\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.25\" to 1.5\" (0.64 to 3.8 cm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eRatio Accuracy- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0% to 2.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eZero Error- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e2.0% to 3.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSupply Pressure Sensitivity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.1 to 0.6 psig for a change of 50 pis (3.5 bar) in supply pressure\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAir Consumption, Maximum depending on output range\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0 to 10 scfh (0.5 to 5.0 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Supply Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 psig (17 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Output Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 psig (10 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Signal Pressure depending on ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 to 25 psig (10.34 to 1.27 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAmbient Temperature Limits\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e-40° to 160°F (-40° to 71°C)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eWeight\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.4 lbs (635 gm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMounting Options\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003ePipe, panel, bracket\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eAluminium\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOther Internal Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eStainless steel, brass, plated steel, acetal, nitrile, polyester\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e429-846-013\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eBSP Porting: Yes\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster-Spec-Sheet1.pdf?v=1786493176\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"ControlAir","offers":[{"title":"Default Title","offer_id":44165553553486,"sku":"429-846-013","price":251.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster__49242.1784299776.1280.1280.jpg?v=1786659751"},{"product_id":"controlair-type-600-series-ratio-relay-volume-booster-429-846-030-600-bdx-ratio-1-6-1-4-npt-atex-2014-34-eu","title":"ControlAir Type 600 Series Ratio Relay Volume Booster, 429-846-030, 600-BDX, Ratio 1:6, 1\/4\" NPT, ATEX 2014\/34\/EU","description":"\u003ch2\u003eControlAir Type 600 Series Ratio Relay Volume Booster (600-BDX)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHigh Flow Capacity: Allows flows up to 50 SCFM (1,400 Nl\/min)\u003c\/li\u003e\n\u003cli\u003eMultiple Signal to Output Ratios: 1:1, 1:2, 1:3, 1:6, 2:1 and 3:1.\u003c\/li\u003e\n\u003cli\u003eStable Output: Venturi aspirator maintains output pressure under varying flow conditions.\u003c\/li\u003e\n\u003cli\u003eMultiple Port Sizes: Available in 1\/4\", 3\/8\" and 1\/2\" NPT\/BSPP.\u003c\/li\u003e\n\u003cli\u003eBalanced Supply Valve: Rolling diaphragm design makes unit insensitive to supply pressure variation.\u003c\/li\u003e\n\u003cli\u003eOptional Negative Bias: 4 psi (0.3 bar) negative bias option allows \"zero\" of I\/P's.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eMeet High Flow Requirements With A Low Flow Pneumatic Signal\u003c\/h2\u003e\u003cp\u003eThe Type 600 ratio relay volume booster is designed to use a pneumatic signal to produce an output pressure which has high flow capacity and can be amplified. This unit is most useful for systems requiring the conversion of a low flow control signal to the higher flow requirements of an operating system. Using an independent supply pressure for greater volume, the Type 600 relays up to 50 scfm (1,400 Nl\/min) flow capacity to a final control element such as a valve actuator. The standard signal to output ratio is 1:1, however, the Type 600 is also available with an amplified ratio of 1:2, 1:3 and 1:6.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal\/Output Ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1:1, 1:2, 1:3, 1:6, 2:1, 3:1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eFlow Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e50 scfm (1415 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePort Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\" BSPP, 1\/2\" NPT, 1\/4\" BSPP, 1\/4\" NPT, 3\/8\" BSPP, 3\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal Port Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/4\" NPT, 1\/4\" BSP\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Port Size (optional)\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Flow Cv\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eSee PDF Sales Sheet\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSensitivity (depending on ratio) water column\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.25\" to 1.5\" (0.64 to 3.8 cm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eRatio Accuracy- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0% to 2.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eZero Error- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e2.0% to 3.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSupply Pressure Sensitivity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.1 to 0.6 psig for a change of 50 pis (3.5 bar) in supply pressure\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAir Consumption, Maximum depending on output range\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0 to 10 scfh (0.5 to 5.0 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Supply Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 psig (17 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Output Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 psig (10 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Signal Pressure depending on ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 to 25 psig (10.34 to 1.27 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAmbient Temperature Limits\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e-40° to 160°F (-40° to 71°C)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eWeight\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.4 lbs (635 gm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMounting Options\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003ePipe, panel, bracket\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eAluminium\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOther Internal Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eStainless steel, brass, plated steel, acetal, nitrile, polyester\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e429-846-030\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eATEX 2014\/34\/EU: Yes\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster-Spec-Sheet1.pdf?v=1786493176\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"ControlAir","offers":[{"title":"Default Title","offer_id":44165554110542,"sku":"429-846-030","price":257.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster__73136.1784299908.1280.1280.jpg?v=1786659754"},{"product_id":"controlair-type-600-series-ratio-relay-volume-booster-ca-t600-1-2-in-type-600-1-2-npt-ratio-1-1-1-6","title":"ControlAir Type 600 Series Ratio Relay Volume Booster, CA-T600-1\/2-in, Type 600, 1\/2\" NPT, Ratio 1:1 - 1:6","description":"\u003ch2\u003eControlAir Type 600 Series Ratio Relay Volume Booster\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHigh Flow Capacity: Allows flows up to 50 SCFM (1,400 Nl\/min)\u003c\/li\u003e\n\u003cli\u003eMultiple Signal to Output Ratios: 1:1, 1:2, 1:3, 1:6, 2:1 and 3:1.\u003c\/li\u003e\n\u003cli\u003eStable Output: Venturi aspirator maintains output pressure under varying flow conditions.\u003c\/li\u003e\n\u003cli\u003eMultiple Port Sizes: Available in 1\/4\", 3\/8\" and 1\/2\" NPT\/BSPP.\u003c\/li\u003e\n\u003cli\u003eBalanced Supply Valve: Rolling diaphragm design makes unit insensitive to supply pressure variation.\u003c\/li\u003e\n\u003cli\u003eOptional Negative Bias: 4 psi (0.3 bar) negative bias option allows \"zero\" of I\/P's.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eMeet High Flow Requirements With A Low Flow Pneumatic Signal\u003c\/h2\u003e\u003cp\u003eThe Type 600 ratio relay volume booster is designed to use a pneumatic signal to produce an output pressure which has high flow capacity and can be amplified. This unit is most useful for systems requiring the conversion of a low flow control signal to the higher flow requirements of an operating system. Using an independent supply pressure for greater volume, the Type 600 relays up to 50 scfm (1,400 Nl\/min) flow capacity to a final control element such as a valve actuator. The standard signal to output ratio is 1:1, however, the Type 600 is also available with an amplified ratio of 1:2, 1:3 and 1:6.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal\/Output Ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1:1, 1:2, 1:3, 1:6, 2:1, 3:1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eFlow Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e50 scfm (1415 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePort Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\" BSPP, 1\/2\" NPT, 1\/4\" BSPP, 1\/4\" NPT, 3\/8\" BSPP, 3\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal Port Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/4\" NPT, 1\/4\" BSP\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Port Size (optional)\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Flow Cv\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eSee PDF Sales Sheet\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSensitivity (depending on ratio) water column\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.25\" to 1.5\" (0.64 to 3.8 cm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eRatio Accuracy- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0% to 2.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eZero Error- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e2.0% to 3.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSupply Pressure Sensitivity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.1 to 0.6 psig for a change of 50 pis (3.5 bar) in supply pressure\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAir Consumption, Maximum depending on output range\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0 to 10 scfh (0.5 to 5.0 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Supply Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 psig (17 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Output Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 psig (10 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Signal Pressure depending on ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 to 25 psig (10.34 to 1.27 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAmbient Temperature Limits\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e-40° to 160°F (-40° to 71°C)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eWeight\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.4 lbs (635 gm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMounting Options\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003ePipe, panel, bracket\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eAluminium\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOther Internal Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eStainless steel, brass, plated steel, acetal, nitrile, polyester\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster-Spec-Sheet1.pdf?v=1786493176\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e\n\u003c\/div\u003e","brand":"ControlAir","offers":[{"title":"Default Title","offer_id":44165554241614,"sku":"CA-T600-1\/2-in","price":218.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster__06586.1784299848.1280.1280.jpg?v=1786659756"},{"product_id":"controlair-type-600-series-ratio-relay-volume-booster-429-846-003-600-bdz-ratio-1-6-1-4-npt-fixed-negative-bias","title":"ControlAir Type 600 Series Ratio Relay Volume Booster, 429-846-003, 600-BDZ, Ratio 1:6, 1\/4\" NPT, Fixed Negative Bias","description":"\u003ch2\u003eControlAir Type 600 Series Ratio Relay Volume Booster (600-BDZ)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHigh Flow Capacity: Allows flows up to 50 SCFM (1,400 Nl\/min)\u003c\/li\u003e\n\u003cli\u003eMultiple Signal to Output Ratios: 1:1, 1:2, 1:3, 1:6, 2:1 and 3:1.\u003c\/li\u003e\n\u003cli\u003eStable Output: Venturi aspirator maintains output pressure under varying flow conditions.\u003c\/li\u003e\n\u003cli\u003eMultiple Port Sizes: Available in 1\/4\", 3\/8\" and 1\/2\" NPT\/BSPP.\u003c\/li\u003e\n\u003cli\u003eBalanced Supply Valve: Rolling diaphragm design makes unit insensitive to supply pressure variation.\u003c\/li\u003e\n\u003cli\u003eOptional Negative Bias: 4 psi (0.3 bar) negative bias option allows \"zero\" of I\/P's.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eMeet High Flow Requirements With A Low Flow Pneumatic Signal\u003c\/h2\u003e\u003cp\u003eThe Type 600 ratio relay volume booster is designed to use a pneumatic signal to produce an output pressure which has high flow capacity and can be amplified. This unit is most useful for systems requiring the conversion of a low flow control signal to the higher flow requirements of an operating system. Using an independent supply pressure for greater volume, the Type 600 relays up to 50 scfm (1,400 Nl\/min) flow capacity to a final control element such as a valve actuator. The standard signal to output ratio is 1:1, however, the Type 600 is also available with an amplified ratio of 1:2, 1:3 and 1:6.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal\/Output Ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1:1, 1:2, 1:3, 1:6, 2:1, 3:1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eFlow Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e50 scfm (1415 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePort Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\" BSPP, 1\/2\" NPT, 1\/4\" BSPP, 1\/4\" NPT, 3\/8\" BSPP, 3\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal Port Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/4\" NPT, 1\/4\" BSP\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Port Size (optional)\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Flow Cv\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eSee PDF Sales Sheet\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSensitivity (depending on ratio) water column\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.25\" to 1.5\" (0.64 to 3.8 cm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eRatio Accuracy- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0% to 2.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eZero Error- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e2.0% to 3.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSupply Pressure Sensitivity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.1 to 0.6 psig for a change of 50 pis (3.5 bar) in supply pressure\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAir Consumption, Maximum depending on output range\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0 to 10 scfh (0.5 to 5.0 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Supply Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 psig (17 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Output Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 psig (10 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Signal Pressure depending on ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 to 25 psig (10.34 to 1.27 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAmbient Temperature Limits\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e-40° to 160°F (-40° to 71°C)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eWeight\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.4 lbs (635 gm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMounting Options\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003ePipe, panel, bracket\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eAluminium\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOther Internal Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eStainless steel, brass, plated steel, acetal, nitrile, polyester\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e429-846-003\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eFixed Negative Bias: Yes\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster-Spec-Sheet1.pdf?v=1786493176\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"ControlAir","offers":[{"title":"Default Title","offer_id":44165554307150,"sku":"429-846-003","price":283.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster__49752.1784299847.1280.1280.jpg?v=1786659757"},{"product_id":"controlair-type-600-series-ratio-relay-volume-booster-429-841-078-600-da-1-2-npt-ratio-1-1","title":"ControlAir Type 600 Series Ratio Relay Volume Booster, 429-841-078, 600-DA, 1\/2\" NPT, Ratio 1:1","description":"\u003ch2\u003eControlAir Type 600 Series Ratio Relay Volume Booster (600-DA)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHigh Flow Capacity: Allows flows up to 50 SCFM (1,400 Nl\/min)\u003c\/li\u003e\n\u003cli\u003eMultiple Signal to Output Ratios: 1:1, 1:2, 1:3, 1:6, 2:1 and 3:1.\u003c\/li\u003e\n\u003cli\u003eStable Output: Venturi aspirator maintains output pressure under varying flow conditions.\u003c\/li\u003e\n\u003cli\u003eMultiple Port Sizes: Available in 1\/4\", 3\/8\" and 1\/2\" NPT\/BSPP.\u003c\/li\u003e\n\u003cli\u003eBalanced Supply Valve: Rolling diaphragm design makes unit insensitive to supply pressure variation.\u003c\/li\u003e\n\u003cli\u003eOptional Negative Bias: 4 psi (0.3 bar) negative bias option allows \"zero\" of I\/P's.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eMeet High Flow Requirements With A Low Flow Pneumatic Signal\u003c\/h2\u003e\u003cp\u003eThe Type 600 ratio relay volume booster is designed to use a pneumatic signal to produce an output pressure which has high flow capacity and can be amplified. This unit is most useful for systems requiring the conversion of a low flow control signal to the higher flow requirements of an operating system. Using an independent supply pressure for greater volume, the Type 600 relays up to 50 scfm (1,400 Nl\/min) flow capacity to a final control element such as a valve actuator. The standard signal to output ratio is 1:1, however, the Type 600 is also available with an amplified ratio of 1:2, 1:3 and 1:6.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal\/Output Ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1:1, 1:2, 1:3, 1:6, 2:1, 3:1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eFlow Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e50 scfm (1415 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePort Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\" BSPP, 1\/2\" NPT, 1\/4\" BSPP, 1\/4\" NPT, 3\/8\" BSPP, 3\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal Port Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/4\" NPT, 1\/4\" BSP\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Port Size (optional)\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Flow Cv\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eSee PDF Sales Sheet\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSensitivity (depending on ratio) water column\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.25\" to 1.5\" (0.64 to 3.8 cm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eRatio Accuracy- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0% to 2.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eZero Error- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e2.0% to 3.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSupply Pressure Sensitivity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.1 to 0.6 psig for a change of 50 pis (3.5 bar) in supply pressure\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAir Consumption, Maximum depending on output range\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0 to 10 scfh (0.5 to 5.0 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Supply Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 psig (17 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Output Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 psig (10 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Signal Pressure depending on ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 to 25 psig (10.34 to 1.27 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAmbient Temperature Limits\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e-40° to 160°F (-40° to 71°C)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eWeight\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.4 lbs (635 gm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMounting Options\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003ePipe, panel, bracket\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eAluminium\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOther Internal Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eStainless steel, brass, plated steel, acetal, nitrile, polyester\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e429-841-078\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster-Spec-Sheet1.pdf?v=1786493176\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"ControlAir","offers":[{"title":"Default Title","offer_id":44165554438222,"sku":"429-841-078","price":218.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster__20548.1784299738.1280.1280.jpg?v=1786659760"},{"product_id":"controlair-type-600-series-ratio-relay-volume-booster-429-841-169-600-dae-1-2-npt-ratio-1-1-tapped-exhaust","title":"ControlAir Type 600 Series Ratio Relay Volume Booster, 429-841-169, 600-DAE, 1\/2\" NPT, Ratio 1:1, Tapped Exhaust","description":"\u003ch2\u003eControlAir Type 600 Series Ratio Relay Volume Booster (600-DAE)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHigh Flow Capacity: Allows flows up to 50 SCFM (1,400 Nl\/min)\u003c\/li\u003e\n\u003cli\u003eMultiple Signal to Output Ratios: 1:1, 1:2, 1:3, 1:6, 2:1 and 3:1.\u003c\/li\u003e\n\u003cli\u003eStable Output: Venturi aspirator maintains output pressure under varying flow conditions.\u003c\/li\u003e\n\u003cli\u003eMultiple Port Sizes: Available in 1\/4\", 3\/8\" and 1\/2\" NPT\/BSPP.\u003c\/li\u003e\n\u003cli\u003eBalanced Supply Valve: Rolling diaphragm design makes unit insensitive to supply pressure variation.\u003c\/li\u003e\n\u003cli\u003eOptional Negative Bias: 4 psi (0.3 bar) negative bias option allows \"zero\" of I\/P's.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eMeet High Flow Requirements With A Low Flow Pneumatic Signal\u003c\/h2\u003e\u003cp\u003eThe Type 600 ratio relay volume booster is designed to use a pneumatic signal to produce an output pressure which has high flow capacity and can be amplified. This unit is most useful for systems requiring the conversion of a low flow control signal to the higher flow requirements of an operating system. Using an independent supply pressure for greater volume, the Type 600 relays up to 50 scfm (1,400 Nl\/min) flow capacity to a final control element such as a valve actuator. The standard signal to output ratio is 1:1, however, the Type 600 is also available with an amplified ratio of 1:2, 1:3 and 1:6.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal\/Output Ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1:1, 1:2, 1:3, 1:6, 2:1, 3:1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eFlow Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e50 scfm (1415 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePort Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\" BSPP, 1\/2\" NPT, 1\/4\" BSPP, 1\/4\" NPT, 3\/8\" BSPP, 3\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal Port Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/4\" NPT, 1\/4\" BSP\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Port Size (optional)\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Flow Cv\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eSee PDF Sales Sheet\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSensitivity (depending on ratio) water column\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.25\" to 1.5\" (0.64 to 3.8 cm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eRatio Accuracy- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0% to 2.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eZero Error- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e2.0% to 3.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSupply Pressure Sensitivity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.1 to 0.6 psig for a change of 50 pis (3.5 bar) in supply pressure\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAir Consumption, Maximum depending on output range\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0 to 10 scfh (0.5 to 5.0 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Supply Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 psig (17 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Output Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 psig (10 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Signal Pressure depending on ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 to 25 psig (10.34 to 1.27 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAmbient Temperature Limits\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e-40° to 160°F (-40° to 71°C)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eWeight\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.4 lbs (635 gm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMounting Options\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003ePipe, panel, bracket\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eAluminium\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOther Internal Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eStainless steel, brass, plated steel, acetal, nitrile, polyester\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e429-841-169\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eTapped Exhaust: Yes\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster-Spec-Sheet1.pdf?v=1786493176\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"ControlAir","offers":[{"title":"Default Title","offer_id":44165554667598,"sku":"429-841-169","price":241.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster__60562.1784299848.1280.1280.jpg?v=1786659761"},{"product_id":"controlair-type-600-series-ratio-relay-volume-booster-429-841-428-600-daeu-1-2-npt-ratio-1-1-tapped-exhaust-bsp-porting","title":"ControlAir Type 600 Series Ratio Relay Volume Booster, 429-841-428, 600-DAEU, 1\/2\" NPT, Ratio 1:1, Tapped Exhaust, BSP Porting","description":"\u003ch2\u003eControlAir Type 600 Series Ratio Relay Volume Booster (600-DAEU)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHigh Flow Capacity: Allows flows up to 50 SCFM (1,400 Nl\/min)\u003c\/li\u003e\n\u003cli\u003eMultiple Signal to Output Ratios: 1:1, 1:2, 1:3, 1:6, 2:1 and 3:1.\u003c\/li\u003e\n\u003cli\u003eStable Output: Venturi aspirator maintains output pressure under varying flow conditions.\u003c\/li\u003e\n\u003cli\u003eMultiple Port Sizes: Available in 1\/4\", 3\/8\" and 1\/2\" NPT\/BSPP.\u003c\/li\u003e\n\u003cli\u003eBalanced Supply Valve: Rolling diaphragm design makes unit insensitive to supply pressure variation.\u003c\/li\u003e\n\u003cli\u003eOptional Negative Bias: 4 psi (0.3 bar) negative bias option allows \"zero\" of I\/P's.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eMeet High Flow Requirements With A Low Flow Pneumatic Signal\u003c\/h2\u003e\u003cp\u003eThe Type 600 ratio relay volume booster is designed to use a pneumatic signal to produce an output pressure which has high flow capacity and can be amplified. This unit is most useful for systems requiring the conversion of a low flow control signal to the higher flow requirements of an operating system. Using an independent supply pressure for greater volume, the Type 600 relays up to 50 scfm (1,400 Nl\/min) flow capacity to a final control element such as a valve actuator. The standard signal to output ratio is 1:1, however, the Type 600 is also available with an amplified ratio of 1:2, 1:3 and 1:6.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal\/Output Ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1:1, 1:2, 1:3, 1:6, 2:1, 3:1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eFlow Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e50 scfm (1415 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePort Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\" BSPP, 1\/2\" NPT, 1\/4\" BSPP, 1\/4\" NPT, 3\/8\" BSPP, 3\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal Port Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/4\" NPT, 1\/4\" BSP\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Port Size (optional)\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Flow Cv\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eSee PDF Sales Sheet\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSensitivity (depending on ratio) water column\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.25\" to 1.5\" (0.64 to 3.8 cm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eRatio Accuracy- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0% to 2.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eZero Error- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e2.0% to 3.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSupply Pressure Sensitivity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.1 to 0.6 psig for a change of 50 pis (3.5 bar) in supply pressure\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAir Consumption, Maximum depending on output range\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0 to 10 scfh (0.5 to 5.0 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Supply Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 psig (17 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Output Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 psig (10 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Signal Pressure depending on ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 to 25 psig (10.34 to 1.27 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAmbient Temperature Limits\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e-40° to 160°F (-40° to 71°C)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eWeight\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.4 lbs (635 gm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMounting Options\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003ePipe, panel, bracket\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eAluminium\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOther Internal Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eStainless steel, brass, plated steel, acetal, nitrile, polyester\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e429-841-428\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eTapped Exhaust: Yes, BSP Porting: Yes\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster-Spec-Sheet1.pdf?v=1786493176\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"ControlAir","offers":[{"title":"Default Title","offer_id":44165555224654,"sku":"429-841-428","price":241.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster__57089.1784299848.1280.1280.jpg?v=1786659764"},{"product_id":"controlair-type-600-series-ratio-relay-volume-booster-429-841-442-600-daeux-1-2-npt-ratio-1-1-tapped-exhaust-bsp-porting-atex-2014-34-eu","title":"ControlAir Type 600 Series Ratio Relay Volume Booster, 429-841-442, 600-DAEUX, 1\/2\" NPT, Ratio 1:1, Tapped Exhaust, BSP Porting, ATEX 2014\/34\/EU","description":"\u003ch2\u003eControlAir Type 600 Series Ratio Relay Volume Booster (600-DAEUX)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHigh Flow Capacity: Allows flows up to 50 SCFM (1,400 Nl\/min)\u003c\/li\u003e\n\u003cli\u003eMultiple Signal to Output Ratios: 1:1, 1:2, 1:3, 1:6, 2:1 and 3:1.\u003c\/li\u003e\n\u003cli\u003eStable Output: Venturi aspirator maintains output pressure under varying flow conditions.\u003c\/li\u003e\n\u003cli\u003eMultiple Port Sizes: Available in 1\/4\", 3\/8\" and 1\/2\" NPT\/BSPP.\u003c\/li\u003e\n\u003cli\u003eBalanced Supply Valve: Rolling diaphragm design makes unit insensitive to supply pressure variation.\u003c\/li\u003e\n\u003cli\u003eOptional Negative Bias: 4 psi (0.3 bar) negative bias option allows \"zero\" of I\/P's.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eMeet High Flow Requirements With A Low Flow Pneumatic Signal\u003c\/h2\u003e\u003cp\u003eThe Type 600 ratio relay volume booster is designed to use a pneumatic signal to produce an output pressure which has high flow capacity and can be amplified. This unit is most useful for systems requiring the conversion of a low flow control signal to the higher flow requirements of an operating system. Using an independent supply pressure for greater volume, the Type 600 relays up to 50 scfm (1,400 Nl\/min) flow capacity to a final control element such as a valve actuator. The standard signal to output ratio is 1:1, however, the Type 600 is also available with an amplified ratio of 1:2, 1:3 and 1:6.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal\/Output Ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1:1, 1:2, 1:3, 1:6, 2:1, 3:1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eFlow Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e50 scfm (1415 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePort Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\" BSPP, 1\/2\" NPT, 1\/4\" BSPP, 1\/4\" NPT, 3\/8\" BSPP, 3\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal Port Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/4\" NPT, 1\/4\" BSP\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Port Size (optional)\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Flow Cv\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eSee PDF Sales Sheet\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSensitivity (depending on ratio) water column\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.25\" to 1.5\" (0.64 to 3.8 cm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eRatio Accuracy- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0% to 2.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eZero Error- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e2.0% to 3.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSupply Pressure Sensitivity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.1 to 0.6 psig for a change of 50 pis (3.5 bar) in supply pressure\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAir Consumption, Maximum depending on output range\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0 to 10 scfh (0.5 to 5.0 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Supply Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 psig (17 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Output Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 psig (10 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Signal Pressure depending on ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 to 25 psig (10.34 to 1.27 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAmbient Temperature Limits\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e-40° to 160°F (-40° to 71°C)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eWeight\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.4 lbs (635 gm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMounting Options\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003ePipe, panel, bracket\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eAluminium\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOther Internal Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eStainless steel, brass, plated steel, acetal, nitrile, polyester\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e429-841-442\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eTapped Exhaust: Yes, BSP Porting: Yes, ATEX 2014\/34\/EU: Yes\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster-Spec-Sheet1.pdf?v=1786493176\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"ControlAir","offers":[{"title":"Default Title","offer_id":44165555781710,"sku":"429-841-442","price":247.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster__52524.1784300316.1280.1280.jpg?v=1786659766"},{"product_id":"controlair-type-600-series-ratio-relay-volume-booster-429-841-370-600-daez-1-2-npt-ratio-1-1-tapped-exhaust-fixed-negative-bias","title":"ControlAir Type 600 Series Ratio Relay Volume Booster, 429-841-370, 600-DAEZ, 1\/2\" NPT, Ratio 1:1, Tapped Exhaust, Fixed Negative Bias","description":"\u003ch2\u003eControlAir Type 600 Series Ratio Relay Volume Booster (600-DAEZ)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHigh Flow Capacity: Allows flows up to 50 SCFM (1,400 Nl\/min)\u003c\/li\u003e\n\u003cli\u003eMultiple Signal to Output Ratios: 1:1, 1:2, 1:3, 1:6, 2:1 and 3:1.\u003c\/li\u003e\n\u003cli\u003eStable Output: Venturi aspirator maintains output pressure under varying flow conditions.\u003c\/li\u003e\n\u003cli\u003eMultiple Port Sizes: Available in 1\/4\", 3\/8\" and 1\/2\" NPT\/BSPP.\u003c\/li\u003e\n\u003cli\u003eBalanced Supply Valve: Rolling diaphragm design makes unit insensitive to supply pressure variation.\u003c\/li\u003e\n\u003cli\u003eOptional Negative Bias: 4 psi (0.3 bar) negative bias option allows \"zero\" of I\/P's.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eMeet High Flow Requirements With A Low Flow Pneumatic Signal\u003c\/h2\u003e\u003cp\u003eThe Type 600 ratio relay volume booster is designed to use a pneumatic signal to produce an output pressure which has high flow capacity and can be amplified. This unit is most useful for systems requiring the conversion of a low flow control signal to the higher flow requirements of an operating system. Using an independent supply pressure for greater volume, the Type 600 relays up to 50 scfm (1,400 Nl\/min) flow capacity to a final control element such as a valve actuator. The standard signal to output ratio is 1:1, however, the Type 600 is also available with an amplified ratio of 1:2, 1:3 and 1:6.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal\/Output Ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1:1, 1:2, 1:3, 1:6, 2:1, 3:1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eFlow Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e50 scfm (1415 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePort Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\" BSPP, 1\/2\" NPT, 1\/4\" BSPP, 1\/4\" NPT, 3\/8\" BSPP, 3\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal Port Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/4\" NPT, 1\/4\" BSP\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Port Size (optional)\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Flow Cv\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eSee PDF Sales Sheet\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSensitivity (depending on ratio) water column\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.25\" to 1.5\" (0.64 to 3.8 cm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eRatio Accuracy- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0% to 2.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eZero Error- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e2.0% to 3.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSupply Pressure Sensitivity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.1 to 0.6 psig for a change of 50 pis (3.5 bar) in supply pressure\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAir Consumption, Maximum depending on output range\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0 to 10 scfh (0.5 to 5.0 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Supply Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 psig (17 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Output Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 psig (10 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Signal Pressure depending on ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 to 25 psig (10.34 to 1.27 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAmbient Temperature Limits\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e-40° to 160°F (-40° to 71°C)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eWeight\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.4 lbs (635 gm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMounting Options\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003ePipe, panel, bracket\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eAluminium\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOther Internal Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eStainless steel, brass, plated steel, acetal, nitrile, polyester\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e429-841-370\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eTapped Exhaust: Yes, Fixed Negative Bias: Yes\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster-Spec-Sheet1.pdf?v=1786493176\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"ControlAir","offers":[{"title":"Default Title","offer_id":44165556338766,"sku":"429-841-370","price":273.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster__64359.1784299909.1280.1280.jpg?v=1786659769"},{"product_id":"controlair-type-600-series-ratio-relay-volume-booster-429-841-175-600-dau-1-2-npt-ratio-1-1-bsp-porting","title":"ControlAir Type 600 Series Ratio Relay Volume Booster, 429-841-175, 600-DAU, 1\/2\" NPT, Ratio 1:1, BSP Porting","description":"\u003ch2\u003eControlAir Type 600 Series Ratio Relay Volume Booster (600-DAU)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHigh Flow Capacity: Allows flows up to 50 SCFM (1,400 Nl\/min)\u003c\/li\u003e\n\u003cli\u003eMultiple Signal to Output Ratios: 1:1, 1:2, 1:3, 1:6, 2:1 and 3:1.\u003c\/li\u003e\n\u003cli\u003eStable Output: Venturi aspirator maintains output pressure under varying flow conditions.\u003c\/li\u003e\n\u003cli\u003eMultiple Port Sizes: Available in 1\/4\", 3\/8\" and 1\/2\" NPT\/BSPP.\u003c\/li\u003e\n\u003cli\u003eBalanced Supply Valve: Rolling diaphragm design makes unit insensitive to supply pressure variation.\u003c\/li\u003e\n\u003cli\u003eOptional Negative Bias: 4 psi (0.3 bar) negative bias option allows \"zero\" of I\/P's.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eMeet High Flow Requirements With A Low Flow Pneumatic Signal\u003c\/h2\u003e\u003cp\u003eThe Type 600 ratio relay volume booster is designed to use a pneumatic signal to produce an output pressure which has high flow capacity and can be amplified. This unit is most useful for systems requiring the conversion of a low flow control signal to the higher flow requirements of an operating system. Using an independent supply pressure for greater volume, the Type 600 relays up to 50 scfm (1,400 Nl\/min) flow capacity to a final control element such as a valve actuator. The standard signal to output ratio is 1:1, however, the Type 600 is also available with an amplified ratio of 1:2, 1:3 and 1:6.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal\/Output Ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1:1, 1:2, 1:3, 1:6, 2:1, 3:1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eFlow Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e50 scfm (1415 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePort Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\" BSPP, 1\/2\" NPT, 1\/4\" BSPP, 1\/4\" NPT, 3\/8\" BSPP, 3\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal Port Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/4\" NPT, 1\/4\" BSP\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Port Size (optional)\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Flow Cv\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eSee PDF Sales Sheet\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSensitivity (depending on ratio) water column\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.25\" to 1.5\" (0.64 to 3.8 cm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eRatio Accuracy- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0% to 2.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eZero Error- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e2.0% to 3.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSupply Pressure Sensitivity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.1 to 0.6 psig for a change of 50 pis (3.5 bar) in supply pressure\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAir Consumption, Maximum depending on output range\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0 to 10 scfh (0.5 to 5.0 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Supply Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 psig (17 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Output Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 psig (10 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Signal Pressure depending on ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 to 25 psig (10.34 to 1.27 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAmbient Temperature Limits\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e-40° to 160°F (-40° to 71°C)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eWeight\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.4 lbs (635 gm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMounting Options\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003ePipe, panel, bracket\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eAluminium\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOther Internal Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eStainless steel, brass, plated steel, acetal, nitrile, polyester\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e429-841-175\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eBSP Porting: Yes\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster-Spec-Sheet1.pdf?v=1786493176\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"ControlAir","offers":[{"title":"Default Title","offer_id":44165557059662,"sku":"429-841-175","price":218.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster__03203.1784299777.1280.1280.jpg?v=1786659771"},{"product_id":"controlair-type-600-series-ratio-relay-volume-booster-429-841-376-600-daux-1-2-npt-ratio-1-1-bsp-porting-atex-2014-34-eu","title":"ControlAir Type 600 Series Ratio Relay Volume Booster, 429-841-376, 600-DAUX, 1\/2\" NPT, Ratio 1:1, BSP Porting, ATEX 2014\/34\/EU","description":"\u003ch2\u003eControlAir Type 600 Series Ratio Relay Volume Booster (600-DAUX)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHigh Flow Capacity: Allows flows up to 50 SCFM (1,400 Nl\/min)\u003c\/li\u003e\n\u003cli\u003eMultiple Signal to Output Ratios: 1:1, 1:2, 1:3, 1:6, 2:1 and 3:1.\u003c\/li\u003e\n\u003cli\u003eStable Output: Venturi aspirator maintains output pressure under varying flow conditions.\u003c\/li\u003e\n\u003cli\u003eMultiple Port Sizes: Available in 1\/4\", 3\/8\" and 1\/2\" NPT\/BSPP.\u003c\/li\u003e\n\u003cli\u003eBalanced Supply Valve: Rolling diaphragm design makes unit insensitive to supply pressure variation.\u003c\/li\u003e\n\u003cli\u003eOptional Negative Bias: 4 psi (0.3 bar) negative bias option allows \"zero\" of I\/P's.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eMeet High Flow Requirements With A Low Flow Pneumatic Signal\u003c\/h2\u003e\u003cp\u003eThe Type 600 ratio relay volume booster is designed to use a pneumatic signal to produce an output pressure which has high flow capacity and can be amplified. This unit is most useful for systems requiring the conversion of a low flow control signal to the higher flow requirements of an operating system. Using an independent supply pressure for greater volume, the Type 600 relays up to 50 scfm (1,400 Nl\/min) flow capacity to a final control element such as a valve actuator. The standard signal to output ratio is 1:1, however, the Type 600 is also available with an amplified ratio of 1:2, 1:3 and 1:6.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal\/Output Ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1:1, 1:2, 1:3, 1:6, 2:1, 3:1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eFlow Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e50 scfm (1415 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePort Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\" BSPP, 1\/2\" NPT, 1\/4\" BSPP, 1\/4\" NPT, 3\/8\" BSPP, 3\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal Port Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/4\" NPT, 1\/4\" BSP\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Port Size (optional)\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Flow Cv\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eSee PDF Sales Sheet\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSensitivity (depending on ratio) water column\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.25\" to 1.5\" (0.64 to 3.8 cm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eRatio Accuracy- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0% to 2.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eZero Error- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e2.0% to 3.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSupply Pressure Sensitivity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.1 to 0.6 psig for a change of 50 pis (3.5 bar) in supply pressure\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAir Consumption, Maximum depending on output range\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0 to 10 scfh (0.5 to 5.0 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Supply Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 psig (17 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Output Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 psig (10 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Signal Pressure depending on ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 to 25 psig (10.34 to 1.27 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAmbient Temperature Limits\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e-40° to 160°F (-40° to 71°C)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eWeight\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.4 lbs (635 gm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMounting Options\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003ePipe, panel, bracket\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eAluminium\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOther Internal Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eStainless steel, brass, plated steel, acetal, nitrile, polyester\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e429-841-376\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eBSP Porting: Yes, ATEX 2014\/34\/EU: Yes\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster-Spec-Sheet1.pdf?v=1786493176\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"ControlAir","offers":[{"title":"Default Title","offer_id":44165557616718,"sku":"429-841-376","price":250.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster__95784.1784300253.1280.1280.jpg?v=1786659774"},{"product_id":"controlair-type-600-series-ratio-relay-volume-booster-429-841-455-600-dax-1-2-npt-ratio-1-1-atex-2014-34-eu","title":"ControlAir Type 600 Series Ratio Relay Volume Booster, 429-841-455, 600-DAX, 1\/2\" NPT, Ratio 1:1, ATEX 2014\/34\/EU","description":"\u003ch2\u003eControlAir Type 600 Series Ratio Relay Volume Booster (600-DAX)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHigh Flow Capacity: Allows flows up to 50 SCFM (1,400 Nl\/min)\u003c\/li\u003e\n\u003cli\u003eMultiple Signal to Output Ratios: 1:1, 1:2, 1:3, 1:6, 2:1 and 3:1.\u003c\/li\u003e\n\u003cli\u003eStable Output: Venturi aspirator maintains output pressure under varying flow conditions.\u003c\/li\u003e\n\u003cli\u003eMultiple Port Sizes: Available in 1\/4\", 3\/8\" and 1\/2\" NPT\/BSPP.\u003c\/li\u003e\n\u003cli\u003eBalanced Supply Valve: Rolling diaphragm design makes unit insensitive to supply pressure variation.\u003c\/li\u003e\n\u003cli\u003eOptional Negative Bias: 4 psi (0.3 bar) negative bias option allows \"zero\" of I\/P's.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eMeet High Flow Requirements With A Low Flow Pneumatic Signal\u003c\/h2\u003e\u003cp\u003eThe Type 600 ratio relay volume booster is designed to use a pneumatic signal to produce an output pressure which has high flow capacity and can be amplified. This unit is most useful for systems requiring the conversion of a low flow control signal to the higher flow requirements of an operating system. Using an independent supply pressure for greater volume, the Type 600 relays up to 50 scfm (1,400 Nl\/min) flow capacity to a final control element such as a valve actuator. The standard signal to output ratio is 1:1, however, the Type 600 is also available with an amplified ratio of 1:2, 1:3 and 1:6.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal\/Output Ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1:1, 1:2, 1:3, 1:6, 2:1, 3:1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eFlow Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e50 scfm (1415 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePort Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\" BSPP, 1\/2\" NPT, 1\/4\" BSPP, 1\/4\" NPT, 3\/8\" BSPP, 3\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal Port Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/4\" NPT, 1\/4\" BSP\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Port Size (optional)\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Flow Cv\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eSee PDF Sales Sheet\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSensitivity (depending on ratio) water column\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.25\" to 1.5\" (0.64 to 3.8 cm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eRatio Accuracy- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0% to 2.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eZero Error- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e2.0% to 3.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSupply Pressure Sensitivity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.1 to 0.6 psig for a change of 50 pis (3.5 bar) in supply pressure\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAir Consumption, Maximum depending on output range\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0 to 10 scfh (0.5 to 5.0 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Supply Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 psig (17 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Output Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 psig (10 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Signal Pressure depending on ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 to 25 psig (10.34 to 1.27 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAmbient Temperature Limits\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e-40° to 160°F (-40° to 71°C)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eWeight\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.4 lbs (635 gm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMounting Options\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003ePipe, panel, bracket\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eAluminium\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOther Internal Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eStainless steel, brass, plated steel, acetal, nitrile, polyester\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e429-841-455\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eATEX 2014\/34\/EU: Yes\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster-Spec-Sheet1.pdf?v=1786493176\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"ControlAir","offers":[{"title":"Default Title","offer_id":44165557813326,"sku":"429-841-455","price":224.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster__19074.1784299848.1280.1280.jpg?v=1786659776"},{"product_id":"controlair-type-600-series-ratio-relay-volume-booster-429-841-106-600-daz-1-2-npt-ratio-1-1-fixed-negative-bias","title":"ControlAir Type 600 Series Ratio Relay Volume Booster, 429-841-106, 600-DAZ, 1\/2\" NPT, Ratio 1:1, Fixed Negative Bias","description":"\u003ch2\u003eControlAir Type 600 Series Ratio Relay Volume Booster (600-DAZ)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHigh Flow Capacity: Allows flows up to 50 SCFM (1,400 Nl\/min)\u003c\/li\u003e\n\u003cli\u003eMultiple Signal to Output Ratios: 1:1, 1:2, 1:3, 1:6, 2:1 and 3:1.\u003c\/li\u003e\n\u003cli\u003eStable Output: Venturi aspirator maintains output pressure under varying flow conditions.\u003c\/li\u003e\n\u003cli\u003eMultiple Port Sizes: Available in 1\/4\", 3\/8\" and 1\/2\" NPT\/BSPP.\u003c\/li\u003e\n\u003cli\u003eBalanced Supply Valve: Rolling diaphragm design makes unit insensitive to supply pressure variation.\u003c\/li\u003e\n\u003cli\u003eOptional Negative Bias: 4 psi (0.3 bar) negative bias option allows \"zero\" of I\/P's.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eMeet High Flow Requirements With A Low Flow Pneumatic Signal\u003c\/h2\u003e\u003cp\u003eThe Type 600 ratio relay volume booster is designed to use a pneumatic signal to produce an output pressure which has high flow capacity and can be amplified. This unit is most useful for systems requiring the conversion of a low flow control signal to the higher flow requirements of an operating system. Using an independent supply pressure for greater volume, the Type 600 relays up to 50 scfm (1,400 Nl\/min) flow capacity to a final control element such as a valve actuator. The standard signal to output ratio is 1:1, however, the Type 600 is also available with an amplified ratio of 1:2, 1:3 and 1:6.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal\/Output Ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1:1, 1:2, 1:3, 1:6, 2:1, 3:1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eFlow Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e50 scfm (1415 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePort Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\" BSPP, 1\/2\" NPT, 1\/4\" BSPP, 1\/4\" NPT, 3\/8\" BSPP, 3\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal Port Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/4\" NPT, 1\/4\" BSP\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Port Size (optional)\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Flow Cv\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eSee PDF Sales Sheet\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSensitivity (depending on ratio) water column\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.25\" to 1.5\" (0.64 to 3.8 cm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eRatio Accuracy- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0% to 2.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eZero Error- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e2.0% to 3.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSupply Pressure Sensitivity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.1 to 0.6 psig for a change of 50 pis (3.5 bar) in supply pressure\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAir Consumption, Maximum depending on output range\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0 to 10 scfh (0.5 to 5.0 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Supply Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 psig (17 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Output Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 psig (10 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Signal Pressure depending on ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 to 25 psig (10.34 to 1.27 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAmbient Temperature Limits\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e-40° to 160°F (-40° to 71°C)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eWeight\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.4 lbs (635 gm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMounting Options\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003ePipe, panel, bracket\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eAluminium\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOther Internal Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eStainless steel, brass, plated steel, acetal, nitrile, polyester\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e429-841-106\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eFixed Negative Bias: Yes\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster-Spec-Sheet1.pdf?v=1786493176\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"ControlAir","offers":[{"title":"Default Title","offer_id":44165558370382,"sku":"429-841-106","price":250.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster__41159.1784299849.1280.1280.jpg?v=1786659779"},{"product_id":"controlair-type-600-series-ratio-relay-volume-booster-429-842-220-600-db-1-2-npt-ratio-1-2","title":"ControlAir Type 600 Series Ratio Relay Volume Booster, 429-842-220, 600-DB, 1\/2\" NPT, Ratio 1:2","description":"\u003ch2\u003eControlAir Type 600 Series Ratio Relay Volume Booster (600-DB)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHigh Flow Capacity: Allows flows up to 50 SCFM (1,400 Nl\/min)\u003c\/li\u003e\n\u003cli\u003eMultiple Signal to Output Ratios: 1:1, 1:2, 1:3, 1:6, 2:1 and 3:1.\u003c\/li\u003e\n\u003cli\u003eStable Output: Venturi aspirator maintains output pressure under varying flow conditions.\u003c\/li\u003e\n\u003cli\u003eMultiple Port Sizes: Available in 1\/4\", 3\/8\" and 1\/2\" NPT\/BSPP.\u003c\/li\u003e\n\u003cli\u003eBalanced Supply Valve: Rolling diaphragm design makes unit insensitive to supply pressure variation.\u003c\/li\u003e\n\u003cli\u003eOptional Negative Bias: 4 psi (0.3 bar) negative bias option allows \"zero\" of I\/P's.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eMeet High Flow Requirements With A Low Flow Pneumatic Signal\u003c\/h2\u003e\u003cp\u003eThe Type 600 ratio relay volume booster is designed to use a pneumatic signal to produce an output pressure which has high flow capacity and can be amplified. This unit is most useful for systems requiring the conversion of a low flow control signal to the higher flow requirements of an operating system. Using an independent supply pressure for greater volume, the Type 600 relays up to 50 scfm (1,400 Nl\/min) flow capacity to a final control element such as a valve actuator. The standard signal to output ratio is 1:1, however, the Type 600 is also available with an amplified ratio of 1:2, 1:3 and 1:6.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal\/Output Ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1:1, 1:2, 1:3, 1:6, 2:1, 3:1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eFlow Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e50 scfm (1415 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePort Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\" BSPP, 1\/2\" NPT, 1\/4\" BSPP, 1\/4\" NPT, 3\/8\" BSPP, 3\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal Port Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/4\" NPT, 1\/4\" BSP\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Port Size (optional)\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Flow Cv\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eSee PDF Sales Sheet\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSensitivity (depending on ratio) water column\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.25\" to 1.5\" (0.64 to 3.8 cm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eRatio Accuracy- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0% to 2.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eZero Error- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e2.0% to 3.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSupply Pressure Sensitivity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.1 to 0.6 psig for a change of 50 pis (3.5 bar) in supply pressure\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAir Consumption, Maximum depending on output range\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0 to 10 scfh (0.5 to 5.0 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Supply Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 psig (17 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Output Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 psig (10 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Signal Pressure depending on ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 to 25 psig (10.34 to 1.27 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAmbient Temperature Limits\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e-40° to 160°F (-40° to 71°C)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eWeight\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.4 lbs (635 gm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMounting Options\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003ePipe, panel, bracket\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eAluminium\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOther Internal Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eStainless steel, brass, plated steel, acetal, nitrile, polyester\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e429-842-220\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster-Spec-Sheet1.pdf?v=1786493176\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"ControlAir","offers":[{"title":"Default Title","offer_id":44165558894670,"sku":"429-842-220","price":279.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster__29579.1784299738.1280.1280.jpg?v=1786659782"},{"product_id":"controlair-type-600-series-ratio-relay-volume-booster-429-842-385-600-dbu-1-2-npt-ratio-1-2-atex-2014-34-eu","title":"ControlAir Type 600 Series Ratio Relay Volume Booster, 429-842-385, 600-DBU, 1\/2\" NPT, Ratio 1:2, ATEX 2014\/34\/EU","description":"\u003ch2\u003eControlAir Type 600 Series Ratio Relay Volume Booster (600-DBU)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHigh Flow Capacity: Allows flows up to 50 SCFM (1,400 Nl\/min)\u003c\/li\u003e\n\u003cli\u003eMultiple Signal to Output Ratios: 1:1, 1:2, 1:3, 1:6, 2:1 and 3:1.\u003c\/li\u003e\n\u003cli\u003eStable Output: Venturi aspirator maintains output pressure under varying flow conditions.\u003c\/li\u003e\n\u003cli\u003eMultiple Port Sizes: Available in 1\/4\", 3\/8\" and 1\/2\" NPT\/BSPP.\u003c\/li\u003e\n\u003cli\u003eBalanced Supply Valve: Rolling diaphragm design makes unit insensitive to supply pressure variation.\u003c\/li\u003e\n\u003cli\u003eOptional Negative Bias: 4 psi (0.3 bar) negative bias option allows \"zero\" of I\/P's.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eMeet High Flow Requirements With A Low Flow Pneumatic Signal\u003c\/h2\u003e\u003cp\u003eThe Type 600 ratio relay volume booster is designed to use a pneumatic signal to produce an output pressure which has high flow capacity and can be amplified. This unit is most useful for systems requiring the conversion of a low flow control signal to the higher flow requirements of an operating system. Using an independent supply pressure for greater volume, the Type 600 relays up to 50 scfm (1,400 Nl\/min) flow capacity to a final control element such as a valve actuator. The standard signal to output ratio is 1:1, however, the Type 600 is also available with an amplified ratio of 1:2, 1:3 and 1:6.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal\/Output Ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1:1, 1:2, 1:3, 1:6, 2:1, 3:1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eFlow Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e50 scfm (1415 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePort Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\" BSPP, 1\/2\" NPT, 1\/4\" BSPP, 1\/4\" NPT, 3\/8\" BSPP, 3\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal Port Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/4\" NPT, 1\/4\" BSP\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Port Size (optional)\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Flow Cv\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eSee PDF Sales Sheet\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSensitivity (depending on ratio) water column\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.25\" to 1.5\" (0.64 to 3.8 cm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eRatio Accuracy- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0% to 2.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eZero Error- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e2.0% to 3.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSupply Pressure Sensitivity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.1 to 0.6 psig for a change of 50 pis (3.5 bar) in supply pressure\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAir Consumption, Maximum depending on output range\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0 to 10 scfh (0.5 to 5.0 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Supply Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 psig (17 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Output Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 psig (10 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Signal Pressure depending on ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 to 25 psig (10.34 to 1.27 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAmbient Temperature Limits\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e-40° to 160°F (-40° to 71°C)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eWeight\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.4 lbs (635 gm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMounting Options\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003ePipe, panel, bracket\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eAluminium\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOther Internal Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eStainless steel, brass, plated steel, acetal, nitrile, polyester\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e429-842-385\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eBSP Porting: Yes\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster-Spec-Sheet1.pdf?v=1786493176\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"ControlAir","offers":[{"title":"Default Title","offer_id":44165559484494,"sku":"429-842-385","price":279.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster__31566.1784299849.1280.1280.jpg?v=1786659784"},{"product_id":"controlair-type-600-series-ratio-relay-volume-booster-429-843-005-600-dc-1-2-npt-ratio-1-3","title":"ControlAir Type 600 Series Ratio Relay Volume Booster, 429-843-005, 600-DC, 1\/2\" NPT, Ratio 1:3","description":"\u003ch2\u003eControlAir Type 600 Series Ratio Relay Volume Booster (600-DC)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHigh Flow Capacity: Allows flows up to 50 SCFM (1,400 Nl\/min)\u003c\/li\u003e\n\u003cli\u003eMultiple Signal to Output Ratios: 1:1, 1:2, 1:3, 1:6, 2:1 and 3:1.\u003c\/li\u003e\n\u003cli\u003eStable Output: Venturi aspirator maintains output pressure under varying flow conditions.\u003c\/li\u003e\n\u003cli\u003eMultiple Port Sizes: Available in 1\/4\", 3\/8\" and 1\/2\" NPT\/BSPP.\u003c\/li\u003e\n\u003cli\u003eBalanced Supply Valve: Rolling diaphragm design makes unit insensitive to supply pressure variation.\u003c\/li\u003e\n\u003cli\u003eOptional Negative Bias: 4 psi (0.3 bar) negative bias option allows \"zero\" of I\/P's.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eMeet High Flow Requirements With A Low Flow Pneumatic Signal\u003c\/h2\u003e\u003cp\u003eThe Type 600 ratio relay volume booster is designed to use a pneumatic signal to produce an output pressure which has high flow capacity and can be amplified. This unit is most useful for systems requiring the conversion of a low flow control signal to the higher flow requirements of an operating system. Using an independent supply pressure for greater volume, the Type 600 relays up to 50 scfm (1,400 Nl\/min) flow capacity to a final control element such as a valve actuator. The standard signal to output ratio is 1:1, however, the Type 600 is also available with an amplified ratio of 1:2, 1:3 and 1:6.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal\/Output Ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1:1, 1:2, 1:3, 1:6, 2:1, 3:1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eFlow Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e50 scfm (1415 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePort Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\" BSPP, 1\/2\" NPT, 1\/4\" BSPP, 1\/4\" NPT, 3\/8\" BSPP, 3\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal Port Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/4\" NPT, 1\/4\" BSP\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Port Size (optional)\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Flow Cv\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eSee PDF Sales Sheet\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSensitivity (depending on ratio) water column\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.25\" to 1.5\" (0.64 to 3.8 cm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eRatio Accuracy- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0% to 2.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eZero Error- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e2.0% to 3.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSupply Pressure Sensitivity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.1 to 0.6 psig for a change of 50 pis (3.5 bar) in supply pressure\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAir Consumption, Maximum depending on output range\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0 to 10 scfh (0.5 to 5.0 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Supply Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 psig (17 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Output Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 psig (10 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Signal Pressure depending on ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 to 25 psig (10.34 to 1.27 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAmbient Temperature Limits\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e-40° to 160°F (-40° to 71°C)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eWeight\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.4 lbs (635 gm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMounting Options\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003ePipe, panel, bracket\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eAluminium\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOther Internal Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eStainless steel, brass, plated steel, acetal, nitrile, polyester\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e429-843-005\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster-Spec-Sheet1.pdf?v=1786493176\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"ControlAir","offers":[{"title":"Default Title","offer_id":44165560139854,"sku":"429-843-005","price":279.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster__59020.1784299738.1280.1280.jpg?v=1786659787"},{"product_id":"controlair-type-600-series-ratio-relay-volume-booster-429-843-046-600-dce-1-2-npt-ratio-1-3-tapped-exhaust","title":"ControlAir Type 600 Series Ratio Relay Volume Booster, 429-843-046, 600-DCE, 1\/2\" NPT, Ratio 1:3, Tapped Exhaust","description":"\u003ch2\u003eControlAir Type 600 Series Ratio Relay Volume Booster (600-DCE)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHigh Flow Capacity: Allows flows up to 50 SCFM (1,400 Nl\/min)\u003c\/li\u003e\n\u003cli\u003eMultiple Signal to Output Ratios: 1:1, 1:2, 1:3, 1:6, 2:1 and 3:1.\u003c\/li\u003e\n\u003cli\u003eStable Output: Venturi aspirator maintains output pressure under varying flow conditions.\u003c\/li\u003e\n\u003cli\u003eMultiple Port Sizes: Available in 1\/4\", 3\/8\" and 1\/2\" NPT\/BSPP.\u003c\/li\u003e\n\u003cli\u003eBalanced Supply Valve: Rolling diaphragm design makes unit insensitive to supply pressure variation.\u003c\/li\u003e\n\u003cli\u003eOptional Negative Bias: 4 psi (0.3 bar) negative bias option allows \"zero\" of I\/P's.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eMeet High Flow Requirements With A Low Flow Pneumatic Signal\u003c\/h2\u003e\u003cp\u003eThe Type 600 ratio relay volume booster is designed to use a pneumatic signal to produce an output pressure which has high flow capacity and can be amplified. This unit is most useful for systems requiring the conversion of a low flow control signal to the higher flow requirements of an operating system. Using an independent supply pressure for greater volume, the Type 600 relays up to 50 scfm (1,400 Nl\/min) flow capacity to a final control element such as a valve actuator. The standard signal to output ratio is 1:1, however, the Type 600 is also available with an amplified ratio of 1:2, 1:3 and 1:6.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal\/Output Ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1:1, 1:2, 1:3, 1:6, 2:1, 3:1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eFlow Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e50 scfm (1415 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePort Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\" BSPP, 1\/2\" NPT, 1\/4\" BSPP, 1\/4\" NPT, 3\/8\" BSPP, 3\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal Port Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/4\" NPT, 1\/4\" BSP\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Port Size (optional)\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Flow Cv\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eSee PDF Sales Sheet\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSensitivity (depending on ratio) water column\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.25\" to 1.5\" (0.64 to 3.8 cm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eRatio Accuracy- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0% to 2.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eZero Error- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e2.0% to 3.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSupply Pressure Sensitivity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.1 to 0.6 psig for a change of 50 pis (3.5 bar) in supply pressure\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAir Consumption, Maximum depending on output range\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0 to 10 scfh (0.5 to 5.0 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Supply Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 psig (17 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Output Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 psig (10 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Signal Pressure depending on ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 to 25 psig (10.34 to 1.27 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAmbient Temperature Limits\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e-40° to 160°F (-40° to 71°C)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eWeight\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.4 lbs (635 gm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMounting Options\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003ePipe, panel, bracket\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eAluminium\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOther Internal Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eStainless steel, brass, plated steel, acetal, nitrile, polyester\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e429-843-046\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eTapped Exhaust: Yes\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster-Spec-Sheet1.pdf?v=1786493176\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"ControlAir","offers":[{"title":"Default Title","offer_id":44165560696910,"sku":"429-843-046","price":302.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster__64357.1784299777.1280.1280.jpg?v=1786659789"},{"product_id":"controlair-type-600-series-ratio-relay-volume-booster-429-843-009-600-dcez-1-2-npt-ratio-1-3-tapped-exhaust-fixed-negative-bias","title":"ControlAir Type 600 Series Ratio Relay Volume Booster, 429-843-009, 600-DCEZ, 1\/2\" NPT, Ratio 1:3, Tapped Exhaust, Fixed Negative Bias","description":"\u003ch2\u003eControlAir Type 600 Series Ratio Relay Volume Booster (600-DCEZ)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHigh Flow Capacity: Allows flows up to 50 SCFM (1,400 Nl\/min)\u003c\/li\u003e\n\u003cli\u003eMultiple Signal to Output Ratios: 1:1, 1:2, 1:3, 1:6, 2:1 and 3:1.\u003c\/li\u003e\n\u003cli\u003eStable Output: Venturi aspirator maintains output pressure under varying flow conditions.\u003c\/li\u003e\n\u003cli\u003eMultiple Port Sizes: Available in 1\/4\", 3\/8\" and 1\/2\" NPT\/BSPP.\u003c\/li\u003e\n\u003cli\u003eBalanced Supply Valve: Rolling diaphragm design makes unit insensitive to supply pressure variation.\u003c\/li\u003e\n\u003cli\u003eOptional Negative Bias: 4 psi (0.3 bar) negative bias option allows \"zero\" of I\/P's.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eMeet High Flow Requirements With A Low Flow Pneumatic Signal\u003c\/h2\u003e\u003cp\u003eThe Type 600 ratio relay volume booster is designed to use a pneumatic signal to produce an output pressure which has high flow capacity and can be amplified. This unit is most useful for systems requiring the conversion of a low flow control signal to the higher flow requirements of an operating system. Using an independent supply pressure for greater volume, the Type 600 relays up to 50 scfm (1,400 Nl\/min) flow capacity to a final control element such as a valve actuator. The standard signal to output ratio is 1:1, however, the Type 600 is also available with an amplified ratio of 1:2, 1:3 and 1:6.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal\/Output Ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1:1, 1:2, 1:3, 1:6, 2:1, 3:1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eFlow Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e50 scfm (1415 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePort Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\" BSPP, 1\/2\" NPT, 1\/4\" BSPP, 1\/4\" NPT, 3\/8\" BSPP, 3\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal Port Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/4\" NPT, 1\/4\" BSP\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Port Size (optional)\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Flow Cv\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eSee PDF Sales Sheet\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSensitivity (depending on ratio) water column\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.25\" to 1.5\" (0.64 to 3.8 cm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eRatio Accuracy- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0% to 2.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eZero Error- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e2.0% to 3.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSupply Pressure Sensitivity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.1 to 0.6 psig for a change of 50 pis (3.5 bar) in supply pressure\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAir Consumption, Maximum depending on output range\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0 to 10 scfh (0.5 to 5.0 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Supply Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 psig (17 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Output Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 psig (10 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Signal Pressure depending on ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 to 25 psig (10.34 to 1.27 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAmbient Temperature Limits\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e-40° to 160°F (-40° to 71°C)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eWeight\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.4 lbs (635 gm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMounting Options\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003ePipe, panel, bracket\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eAluminium\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOther Internal Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eStainless steel, brass, plated steel, acetal, nitrile, polyester\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e429-843-009\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eTapped Exhaust: Yes, Fixed Negative Bias: Yes\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster-Spec-Sheet1.pdf?v=1786493176\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"ControlAir","offers":[{"title":"Default Title","offer_id":44165560893518,"sku":"429-843-009","price":334.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster__76242.1784299909.1280.1280.jpg?v=1786659792"},{"product_id":"controlair-type-600-series-ratio-relay-volume-booster-429-843-023-600-dcu-1-2-npt-ratio-1-3-bsp-porting","title":"ControlAir Type 600 Series Ratio Relay Volume Booster, 429-843-023, 600-DCU, 1\/2\" NPT, Ratio 1:3, BSP Porting","description":"\u003ch2\u003eControlAir Type 600 Series Ratio Relay Volume Booster (600-DCU)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHigh Flow Capacity: Allows flows up to 50 SCFM (1,400 Nl\/min)\u003c\/li\u003e\n\u003cli\u003eMultiple Signal to Output Ratios: 1:1, 1:2, 1:3, 1:6, 2:1 and 3:1.\u003c\/li\u003e\n\u003cli\u003eStable Output: Venturi aspirator maintains output pressure under varying flow conditions.\u003c\/li\u003e\n\u003cli\u003eMultiple Port Sizes: Available in 1\/4\", 3\/8\" and 1\/2\" NPT\/BSPP.\u003c\/li\u003e\n\u003cli\u003eBalanced Supply Valve: Rolling diaphragm design makes unit insensitive to supply pressure variation.\u003c\/li\u003e\n\u003cli\u003eOptional Negative Bias: 4 psi (0.3 bar) negative bias option allows \"zero\" of I\/P's.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eMeet High Flow Requirements With A Low Flow Pneumatic Signal\u003c\/h2\u003e\u003cp\u003eThe Type 600 ratio relay volume booster is designed to use a pneumatic signal to produce an output pressure which has high flow capacity and can be amplified. This unit is most useful for systems requiring the conversion of a low flow control signal to the higher flow requirements of an operating system. Using an independent supply pressure for greater volume, the Type 600 relays up to 50 scfm (1,400 Nl\/min) flow capacity to a final control element such as a valve actuator. The standard signal to output ratio is 1:1, however, the Type 600 is also available with an amplified ratio of 1:2, 1:3 and 1:6.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal\/Output Ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1:1, 1:2, 1:3, 1:6, 2:1, 3:1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eFlow Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e50 scfm (1415 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePort Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\" BSPP, 1\/2\" NPT, 1\/4\" BSPP, 1\/4\" NPT, 3\/8\" BSPP, 3\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal Port Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/4\" NPT, 1\/4\" BSP\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Port Size (optional)\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Flow Cv\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eSee PDF Sales Sheet\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSensitivity (depending on ratio) water column\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.25\" to 1.5\" (0.64 to 3.8 cm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eRatio Accuracy- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0% to 2.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eZero Error- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e2.0% to 3.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSupply Pressure Sensitivity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.1 to 0.6 psig for a change of 50 pis (3.5 bar) in supply pressure\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAir Consumption, Maximum depending on output range\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0 to 10 scfh (0.5 to 5.0 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Supply Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 psig (17 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Output Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 psig (10 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Signal Pressure depending on ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 to 25 psig (10.34 to 1.27 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAmbient Temperature Limits\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e-40° to 160°F (-40° to 71°C)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eWeight\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.4 lbs (635 gm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMounting Options\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003ePipe, panel, bracket\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eAluminium\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOther Internal Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eStainless steel, brass, plated steel, acetal, nitrile, polyester\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e429-843-023\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eBSP Porting: Yes\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster-Spec-Sheet1.pdf?v=1786493176\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"ControlAir","offers":[{"title":"Default Title","offer_id":44165561450574,"sku":"429-843-023","price":279.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster__96730.1784299849.1280.1280.jpg?v=1786659795"},{"product_id":"controlair-type-600-series-ratio-relay-volume-booster-429-843-037-600-dcz-1-2-npt-ratio-1-3-fixed-negative-bias","title":"ControlAir Type 600 Series Ratio Relay Volume Booster, 429-843-037, 600-DCZ, 1\/2\" NPT, Ratio 1:3, Fixed Negative Bias","description":"\u003ch2\u003eControlAir Type 600 Series Ratio Relay Volume Booster (600-DCZ)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHigh Flow Capacity: Allows flows up to 50 SCFM (1,400 Nl\/min)\u003c\/li\u003e\n\u003cli\u003eMultiple Signal to Output Ratios: 1:1, 1:2, 1:3, 1:6, 2:1 and 3:1.\u003c\/li\u003e\n\u003cli\u003eStable Output: Venturi aspirator maintains output pressure under varying flow conditions.\u003c\/li\u003e\n\u003cli\u003eMultiple Port Sizes: Available in 1\/4\", 3\/8\" and 1\/2\" NPT\/BSPP.\u003c\/li\u003e\n\u003cli\u003eBalanced Supply Valve: Rolling diaphragm design makes unit insensitive to supply pressure variation.\u003c\/li\u003e\n\u003cli\u003eOptional Negative Bias: 4 psi (0.3 bar) negative bias option allows \"zero\" of I\/P's.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eMeet High Flow Requirements With A Low Flow Pneumatic Signal\u003c\/h2\u003e\u003cp\u003eThe Type 600 ratio relay volume booster is designed to use a pneumatic signal to produce an output pressure which has high flow capacity and can be amplified. This unit is most useful for systems requiring the conversion of a low flow control signal to the higher flow requirements of an operating system. Using an independent supply pressure for greater volume, the Type 600 relays up to 50 scfm (1,400 Nl\/min) flow capacity to a final control element such as a valve actuator. The standard signal to output ratio is 1:1, however, the Type 600 is also available with an amplified ratio of 1:2, 1:3 and 1:6.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal\/Output Ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1:1, 1:2, 1:3, 1:6, 2:1, 3:1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eFlow Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e50 scfm (1415 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePort Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\" BSPP, 1\/2\" NPT, 1\/4\" BSPP, 1\/4\" NPT, 3\/8\" BSPP, 3\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal Port Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/4\" NPT, 1\/4\" BSP\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Port Size (optional)\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Flow Cv\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eSee PDF Sales Sheet\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSensitivity (depending on ratio) water column\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.25\" to 1.5\" (0.64 to 3.8 cm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eRatio Accuracy- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0% to 2.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eZero Error- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e2.0% to 3.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSupply Pressure Sensitivity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.1 to 0.6 psig for a change of 50 pis (3.5 bar) in supply pressure\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAir Consumption, Maximum depending on output range\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0 to 10 scfh (0.5 to 5.0 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Supply Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 psig (17 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Output Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 psig (10 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Signal Pressure depending on ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 to 25 psig (10.34 to 1.27 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAmbient Temperature Limits\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e-40° to 160°F (-40° to 71°C)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eWeight\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.4 lbs (635 gm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMounting Options\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003ePipe, panel, bracket\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eAluminium\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOther Internal Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eStainless steel, brass, plated steel, acetal, nitrile, polyester\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e429-843-037\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eFixed Negative Bias: Yes\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster-Spec-Sheet1.pdf?v=1786493176\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"ControlAir","offers":[{"title":"Default Title","offer_id":44165562073166,"sku":"429-843-037","price":311.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster__56729.1784299849.1280.1280.jpg?v=1786659799"},{"product_id":"controlair-type-600-series-ratio-relay-volume-booster-429-846-006-600-dd-1-2-npt-ratio-1-6","title":"ControlAir Type 600 Series Ratio Relay Volume Booster, 429-846-006, 600-DD, 1\/2\" NPT, Ratio 1:6","description":"\u003ch2\u003eControlAir Type 600 Series Ratio Relay Volume Booster (600-DD)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHigh Flow Capacity: Allows flows up to 50 SCFM (1,400 Nl\/min)\u003c\/li\u003e\n\u003cli\u003eMultiple Signal to Output Ratios: 1:1, 1:2, 1:3, 1:6, 2:1 and 3:1.\u003c\/li\u003e\n\u003cli\u003eStable Output: Venturi aspirator maintains output pressure under varying flow conditions.\u003c\/li\u003e\n\u003cli\u003eMultiple Port Sizes: Available in 1\/4\", 3\/8\" and 1\/2\" NPT\/BSPP.\u003c\/li\u003e\n\u003cli\u003eBalanced Supply Valve: Rolling diaphragm design makes unit insensitive to supply pressure variation.\u003c\/li\u003e\n\u003cli\u003eOptional Negative Bias: 4 psi (0.3 bar) negative bias option allows \"zero\" of I\/P's.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eMeet High Flow Requirements With A Low Flow Pneumatic Signal\u003c\/h2\u003e\u003cp\u003eThe Type 600 ratio relay volume booster is designed to use a pneumatic signal to produce an output pressure which has high flow capacity and can be amplified. This unit is most useful for systems requiring the conversion of a low flow control signal to the higher flow requirements of an operating system. Using an independent supply pressure for greater volume, the Type 600 relays up to 50 scfm (1,400 Nl\/min) flow capacity to a final control element such as a valve actuator. The standard signal to output ratio is 1:1, however, the Type 600 is also available with an amplified ratio of 1:2, 1:3 and 1:6.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal\/Output Ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1:1, 1:2, 1:3, 1:6, 2:1, 3:1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eFlow Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e50 scfm (1415 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePort Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\" BSPP, 1\/2\" NPT, 1\/4\" BSPP, 1\/4\" NPT, 3\/8\" BSPP, 3\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal Port Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/4\" NPT, 1\/4\" BSP\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Port Size (optional)\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/8\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Flow Cv\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eSee PDF Sales Sheet\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSensitivity (depending on ratio) water column\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.25\" to 1.5\" (0.64 to 3.8 cm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eRatio Accuracy- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0% to 2.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eZero Error- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e2.0% to 3.0%\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSupply Pressure Sensitivity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.1 to 0.6 psig for a change of 50 pis (3.5 bar) in supply pressure\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAir Consumption, Maximum depending on output range\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.0 to 10 scfh (0.5 to 5.0 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Supply Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 psig (17 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Output Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 psig (10 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Signal Pressure depending on ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 to 25 psig (10.34 to 1.27 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAmbient Temperature Limits\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e-40° to 160°F (-40° to 71°C)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eWeight\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1.4 lbs (635 gm)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMounting Options\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003ePipe, panel, bracket\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eAluminium\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOther Internal Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eStainless steel, brass, plated steel, acetal, nitrile, polyester\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e429-846-006\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster-Spec-Sheet1.pdf?v=1786493176\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"ControlAir","offers":[{"title":"Default Title","offer_id":44165562630222,"sku":"429-846-006","price":279.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster__01524.1784299739.1280.1280.jpg?v=1786659801"},{"product_id":"controlair-type-600-series-ratio-relay-volume-booster-429-846-041-600-ddxz-1-2-npt-ratio-1-6-atex-2014-34-eu-fixed-negative-bias","title":"ControlAir Type 600 Series Ratio Relay Volume Booster, 429-846-041, 600-DDXZ, 1\/2\" NPT, Ratio 1:6, ATEX 2014\/34\/EU, Fixed Negative Bias","description":"\u003ch2\u003eControlAir Type 600 Series Ratio Relay Volume Booster (600-DDXZ)\u003c\/h2\u003e \u003ch2\u003eFeatures:\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eHigh Flow Capacity: Allows flows up to 50 SCFM (1,400 Nl\/min)\u003c\/li\u003e \u003cli\u003eMultiple Signal to Output Ratios: 1:1, 1:2, 1:3, 1:6, 2:1 and 3:1.\u003c\/li\u003e \u003cli\u003eStable Output: Venturi aspirator maintains output pressure under varying flow conditions.\u003c\/li\u003e \u003cli\u003eMultiple Port Sizes: Available in 1\/4\", 3\/8\" and 1\/2\" NPT\/BSPP.\u003c\/li\u003e \u003cli\u003eBalanced Supply Valve: Rolling diaphragm design makes unit insensitive to supply pressure variation.\u003c\/li\u003e \u003cli\u003eOptional Negative Bias: 4 psi (0.3 bar) negative bias option allows \"zero\" of I\/P's.\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e \u003ch2\u003eMeet High Flow Requirements With A Low Flow Pneumatic Signal\u003c\/h2\u003e \u003cp\u003eThe Type 600 ratio relay volume booster is designed to use a pneumatic signal to produce an output pressure which has high flow capacity and can be amplified. This unit is most useful for systems requiring the conversion of a low flow control signal to the higher flow requirements of an operating system. Using an independent supply pressure for greater volume, the Type 600 relays up to 50 scfm (1,400 Nl\/min) flow capacity to a final control element such as a valve actuator. The standard signal to output ratio is 1:1, however, the Type 600 is also available with an amplified ratio of 1:2, 1:3 and 1:6.\u003c\/p\u003e \u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e \u003cdiv class=\"tech\"\u003e \u003ch2\u003eTechnical Specifications\u003c\/h2\u003e \u003cdiv class=\"specs\"\u003e \u003cdiv class=\"column\"\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eSignal\/Output Ratio\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e1:1, 1:2, 1:3, 1:6, 2:1, 3:1\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eFlow Capacity\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e50 scfm (1415 Nl\/min)\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003ePort Size\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e1\/2\" BSPP, 1\/2\" NPT, 1\/4\" BSPP, 1\/4\" NPT, 3\/8\" BSPP, 3\/8\" NPT\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eSignal Port Size\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e1\/4\" NPT, 1\/4\" BSP\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eExhaust Port Size (optional)\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e1\/8\" NPT\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eMax. Flow Cv\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e1\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eExhaust Capacity\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eSee PDF Sales Sheet\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eSensitivity (depending on ratio) water column\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e0.25\" to 1.5\" (0.64 to 3.8 cm)\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eRatio Accuracy- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e1.0% to 2.0%\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eZero Error- % of output span w\/ 3-15 psig (0.2 to 1.05 bar) signal\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e2.0% to 3.0%\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"column\"\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eSupply Pressure Sensitivity\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e0.1 to 0.6 psig for a change of 50 pis (3.5 bar) in supply pressure\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eAir Consumption, Maximum depending on output range\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e1.0 to 10 scfh (0.5 to 5.0 Nl\/min)\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eMax. Supply Pressure\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e250 psig (17 bar)\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eMax. Output Pressure\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e150 psig (10 bar)\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eMax. Signal Pressure depending on ratio\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e150 to 25 psig (10.34 to 1.27 bar)\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eAmbient Temperature Limits\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e-40° to 160°F (-40° to 71°C)\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eWeight\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e1.4 lbs (635 gm)\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eMounting Options\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003ePipe, panel, bracket\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eBody Materials\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eAluminium\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eOther Internal Materials\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eStainless steel, brass, plated steel, acetal, nitrile, polyester\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e429-846-041\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eATEX 2014\/34\/EU: Yes, Fixed Negative Bias: Yes\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e \u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster-Spec-Sheet1.pdf?v=1786493176\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"ControlAir","offers":[{"title":"Default Title","offer_id":44165563187278,"sku":"429-846-041","price":317.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-600-Volume-Booster__54183.1784300316.1280.1280.jpg?v=1786659804"},{"product_id":"controlair-type-6100-series-high-flow-capacity-volume-booster-ca-t6100-14-12-34-in-type-6100-aluminum-1-4-1-2-3-4-npt","title":"ControlAir Type 6100 Series High Flow Capacity Volume Booster, CA-T6100-14-12-34-IN, Type 6100, Aluminum, 1\/4\", 1\/2\", 3\/4\" NPT","description":"\u003ch2\u003eControlAir Type 6100 Series High Flow Capacity Volume Booster\u003c\/h2\u003e \u003ch2\u003eFeatures:\u003c\/h2\u003e \u003cul\u003e \u003cli\u003e1\/4”, 1\/2” or 3\/4\" NPT Porting\u003c\/li\u003e \u003cli\u003eAluminum or 316 Stainless Steel Construction\u003c\/li\u003e \u003cli\u003eIntegral Adjustable Bypass Valve: Allows small incremental signal changes without opening the primary valve.\u003c\/li\u003e \u003cli\u003eHigh Flow Capacity: For rapid actuator stroking.\u003c\/li\u003e \u003cli\u003eSoft Valve Seat Design Provides tight shutoff and eliminates leakage in steady state operation.\u003c\/li\u003e \u003cli\u003eHigh Temperature Operation: Up to 200°F (93°C), Optional 284°F (140°C)\u003c\/li\u003e \u003cli\u003eHigh Output Exhaust Vents: (2) 1\/4\" NPT tapped exhaust (Type 6100 option) 1\/2\" NPT tapped exhaust (Type 6200 standard)\u003c\/li\u003e \u003cli\u003e(2) 1\/4\" NPT Gauge Ports\u003c\/li\u003e \u003cli\u003eOptional Negative Bias: 4 psi (0.3 bar) negative bias of signal pressure to 'zero' I\/P's\u003c\/li\u003e \u003cli\u003eIEC 61508 SIL3 Certified\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e \u003ch2\u003eRapid Stroke Capability In A Rugged Aluminum Casing\u003c\/h2\u003e \u003cp\u003eThe Type 6100 aluminum volume booster is a 1:1 signal to output relays that is utilized in applications that require high forward airflow and exhaust capacities. Typically they are used to increase the throttling speed of large volume valve actuators. They are suitable for either diaphragm or piston actuators. A fixed deadband and adjustable bypass valve combine to allow small incremental downstream adjustment without opening the main booster valve. The bypass valve is used to adjust dynamic response to provide stable operation over a wide range of actuator sizes. Negative Bias adjustment (up to -4 psi) is available to “zero” downstream pressures when using standard signal pressure ranges.\u003c\/p\u003e \u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e \u003cdiv class=\"tech\"\u003e \u003ch2\u003eTechnical Specifications\u003c\/h2\u003e \u003cdiv class=\"specs\"\u003e \u003cdiv class=\"column\"\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eFlow Capacity\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e250 scfm (7,075 Nl.min)\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003ePort Size\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e1\/2\" NPT, 1\/4\" NPT, 3\/4\" NPT\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eSignal Port Size\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e1\/4\" NPT\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eExhaust Port Size (optional)\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e1\/4\" NPT\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eGauge Port Size\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e1\/4\" NPT\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eMaximum Flow\/Exhaust Coefficient (Cv) 1\/4\" port\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e2 \/ 3.5\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eMaximum Flow\/Exhaust Coefficient (Cv) 1\/2\" port\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e4.5 \/ 3.5\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eMaximum Flow\/Exhaust Coefficient (Cv) 3\/4\" port\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e5 \/ 3.5\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eExhaust Capacity (3\/4\" port)\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e80 scfm (2, 264 Nl\/min)\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eSignal\/Output Ratio\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e1:1\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eDeadband\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eless than 0.2 psig (0.01 bar)\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"column\"\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eSupply Pressure Sensitivity\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e0.1 psig (0.007 bar) for a 25 psi (1.7 bar) change in supply pressure\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eMax. Supply Pressure\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e250 psig (17 bar)\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eMax. Output Pressure\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e150 psig (10 bar)\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eMax. Signal Pressure\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e150 psig (10 bar)\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eAmbient Temperature Limits\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e-40° to 200°F (-40° to 93°C)\u003c\/div\u003e \u003cdiv\u003eLow Temperature Option: -62° to 194°F (-52° to 90°C)\u003c\/div\u003e \u003cdiv\u003eExpanded Temperature Option: -65° to 284°F (-54° to 140°C)\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eWeight\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e2.5 lbs (1.13 kg)\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eMounting Options\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eIn line, mounting bracket\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eBody Materials\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eAluminium\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eOther Materials\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eZinc platted steel, nitrile, silicone\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eCA-T6100-14-12-34-IN\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e \u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-6100-High-Flow-Capacity-Volume-Booster-Spec-Sheet.pdf?v=1786493229\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"ControlAir","offers":[{"title":"Default Title","offer_id":44165564989518,"sku":"CA-T6100-14-12-34-IN","price":458.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-6100-High-Flow-Capacity-Volume-Booster__04608.1784299909.1280.1280.jpg?v=1786659814"},{"product_id":"controlair-type-6100-series-high-flow-capacity-volume-booster-429-841-341-6100-ba-aluminum-1-4-npt","title":"ControlAir Type 6100 Series High Flow Capacity Volume Booster, 429-841-341, 6100-BA, Aluminum, 1\/4\" NPT","description":"\u003ch2\u003eControlAir Type 6100 Series High Flow Capacity Volume Booster (6100-BA)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e1\/4”, 1\/2” or 3\/4\" NPT Porting\u003c\/li\u003e\n\u003cli\u003eAluminum or 316 Stainless Steel Construction\u003c\/li\u003e\n\u003cli\u003eIntegral Adjustable Bypass Valve: Allows small incremental signal changes without opening the primary valve.\u003c\/li\u003e\n\u003cli\u003eHigh Flow Capacity: For rapid actuator stroking.\u003c\/li\u003e\n\u003cli\u003eSoft Valve Seat Design Provides tight shutoff and eliminates leakage in steady state operation.\u003c\/li\u003e\n\u003cli\u003eHigh Temperature Operation: Up to 200°F (93°C), Optional 284°F (140°C)\u003c\/li\u003e\n\u003cli\u003eHigh Output Exhaust Vents: (2) 1\/4\" NPT tapped exhaust (Type 6100 option) 1\/2\" NPT tapped exhaust (Type 6200 standard)\u003c\/li\u003e\n\u003cli\u003e(2) 1\/4\" NPT Gauge Ports\u003c\/li\u003e\n\u003cli\u003eOptional Negative Bias: 4 psi (0.3 bar) negative bias of signal pressure to 'zero' I\/P's\u003c\/li\u003e\n\u003cli\u003eIEC 61508 SIL3 Certified\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eRapid Stroke Capability In A Rugged Aluminum Casing\u003c\/h2\u003e\u003cp\u003eThe Type 6100 aluminum volume booster is a 1:1 signal to output relays that is utilized in applications that require high forward airflow and exhaust capacities. Typically they are used to increase the throttling speed of large volume valve actuators. They are suitable for either diaphragm or piston actuators. A fixed deadband and adjustable bypass valve combine to allow small incremental downstream adjustment without opening the main booster valve. The bypass valve is used to adjust dynamic response to provide stable operation over a wide range of actuator sizes. Negative Bias adjustment (up to -4 psi) is available to “zero” downstream pressures when using standard signal pressure ranges.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eFlow Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 scfm (7,075 Nl.min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePort Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\" NPT, 1\/4\" NPT, 3\/4\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal Port Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/4\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Port Size (optional)\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/4\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eGauge Port Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/4\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMaximum Flow\/Exhaust Coefficient (Cv) 1\/4\" port\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e2 \/ 3.5\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMaximum Flow\/Exhaust Coefficient (Cv) 1\/2\" port\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e4.5 \/ 3.5\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMaximum Flow\/Exhaust Coefficient (Cv) 3\/4\" port\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e5 \/ 3.5\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Capacity (3\/4\" port)\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e80 scfm (2, 264 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal\/Output Ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1:1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eDeadband\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eless than 0.2 psig (0.01 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSupply Pressure Sensitivity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.1 psig (0.007 bar) for a 25 psi (1.7 bar) change in supply pressure\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Supply Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 psig (17 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Output Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 psig (10 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Signal Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 psig (10 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAmbient Temperature Limits\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\n\u003cdiv\u003e-40° to 200°F (-40° to 93°C)\u003c\/div\u003e\n\u003cdiv\u003eLow Temperature Option: -62° to 194°F (-52° to 90°C)\u003c\/div\u003e\n\u003cdiv\u003eExpanded Temperature Option: -65° to 284°F (-54° to 140°C)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eWeight\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e2.5 lbs (1.13 kg)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMounting Options\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eIn line, mounting bracket\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eAluminium\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOther Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eZinc platted steel, nitrile, silicone\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e429-841-341\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-6100-High-Flow-Capacity-Volume-Booster-Spec-Sheet.pdf?v=1786493229\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"ControlAir","offers":[{"title":"Default Title","offer_id":44165565153358,"sku":"429-841-341","price":458.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-6100-High-Flow-Capacity-Volume-Booster__72464.1784299739.1280.1280.jpg?v=1786659816"},{"product_id":"controlair-type-6100-series-high-flow-capacity-volume-booster-429-841-413-6100-bae-aluminum-1-4-npt-tapped-exhaust-2-1-4-npt","title":"ControlAir Type 6100 Series High Flow Capacity Volume Booster, 429-841-413, 6100-BAE, Aluminum, 1\/4\" NPT, Tapped Exhaust (2) 1\/4\" NPT","description":"\u003ch2\u003eControlAir Type 6100 Series High Flow Capacity Volume Booster (6100-BAE)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e1\/4”, 1\/2” or 3\/4\" NPT Porting\u003c\/li\u003e\n\u003cli\u003eAluminum or 316 Stainless Steel Construction\u003c\/li\u003e\n\u003cli\u003eIntegral Adjustable Bypass Valve: Allows small incremental signal changes without opening the primary valve.\u003c\/li\u003e\n\u003cli\u003eHigh Flow Capacity: For rapid actuator stroking.\u003c\/li\u003e\n\u003cli\u003eSoft Valve Seat Design Provides tight shutoff and eliminates leakage in steady state operation.\u003c\/li\u003e\n\u003cli\u003eHigh Temperature Operation: Up to 200°F (93°C), Optional 284°F (140°C)\u003c\/li\u003e\n\u003cli\u003eHigh Output Exhaust Vents: (2) 1\/4\" NPT tapped exhaust (Type 6100 option) 1\/2\" NPT tapped exhaust (Type 6200 standard)\u003c\/li\u003e\n\u003cli\u003e(2) 1\/4\" NPT Gauge Ports\u003c\/li\u003e\n\u003cli\u003eOptional Negative Bias: 4 psi (0.3 bar) negative bias of signal pressure to 'zero' I\/P's\u003c\/li\u003e\n\u003cli\u003eIEC 61508 SIL3 Certified\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eRapid Stroke Capability In A Rugged Aluminum Casing\u003c\/h2\u003e\u003cp\u003eThe Type 6100 aluminum volume booster is a 1:1 signal to output relays that is utilized in applications that require high forward airflow and exhaust capacities. Typically they are used to increase the throttling speed of large volume valve actuators. They are suitable for either diaphragm or piston actuators. A fixed deadband and adjustable bypass valve combine to allow small incremental downstream adjustment without opening the main booster valve. The bypass valve is used to adjust dynamic response to provide stable operation over a wide range of actuator sizes. Negative Bias adjustment (up to -4 psi) is available to “zero” downstream pressures when using standard signal pressure ranges.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eFlow Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 scfm (7,075 Nl.min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePort Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\" NPT, 1\/4\" NPT, 3\/4\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal Port Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/4\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Port Size (optional)\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/4\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eGauge Port Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/4\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMaximum Flow\/Exhaust Coefficient (Cv) 1\/4\" port\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e2 \/ 3.5\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMaximum Flow\/Exhaust Coefficient (Cv) 1\/2\" port\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e4.5 \/ 3.5\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMaximum Flow\/Exhaust Coefficient (Cv) 3\/4\" port\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e5 \/ 3.5\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Capacity (3\/4\" port)\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e80 scfm (2, 264 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal\/Output Ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1:1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eDeadband\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eless than 0.2 psig (0.01 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSupply Pressure Sensitivity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.1 psig (0.007 bar) for a 25 psi (1.7 bar) change in supply pressure\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Supply Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 psig (17 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Output Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 psig (10 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Signal Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 psig (10 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAmbient Temperature Limits\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\n\u003cdiv\u003e-40° to 200°F (-40° to 93°C)\u003c\/div\u003e\n\u003cdiv\u003eLow Temperature Option: -62° to 194°F (-52° to 90°C)\u003c\/div\u003e\n\u003cdiv\u003eExpanded Temperature Option: -65° to 284°F (-54° to 140°C)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eWeight\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e2.5 lbs (1.13 kg)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMounting Options\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eIn line, mounting bracket\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eAluminium\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOther Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eZinc platted steel, nitrile, silicone\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e429-841-413\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eTapped Exhaust (2) 1\/4\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-6100-High-Flow-Capacity-Volume-Booster-Spec-Sheet.pdf?v=1786493229\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"ControlAir","offers":[{"title":"Default Title","offer_id":44165565710414,"sku":"429-841-413","price":503.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-6100-High-Flow-Capacity-Volume-Booster__01932.1784300254.1280.1280.jpg?v=1786659818"},{"product_id":"controlair-type-6100-series-high-flow-capacity-volume-booster-429-841-387-6100-baz-aluminum-1-4-npt-fixed-negative-bias","title":"ControlAir Type 6100 Series High Flow Capacity Volume Booster, 429-841-387, 6100-BAZ, Aluminum, 1\/4\" NPT, Fixed Negative Bias","description":"\u003ch2\u003eControlAir Type 6100 Series High Flow Capacity Volume Booster (6100-BAZ)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e1\/4”, 1\/2” or 3\/4\" NPT Porting\u003c\/li\u003e\n\u003cli\u003eAluminum or 316 Stainless Steel Construction\u003c\/li\u003e\n\u003cli\u003eIntegral Adjustable Bypass Valve: Allows small incremental signal changes without opening the primary valve.\u003c\/li\u003e\n\u003cli\u003eHigh Flow Capacity: For rapid actuator stroking.\u003c\/li\u003e\n\u003cli\u003eSoft Valve Seat Design Provides tight shutoff and eliminates leakage in steady state operation.\u003c\/li\u003e\n\u003cli\u003eHigh Temperature Operation: Up to 200°F (93°C), Optional 284°F (140°C)\u003c\/li\u003e\n\u003cli\u003eHigh Output Exhaust Vents: (2) 1\/4\" NPT tapped exhaust (Type 6100 option) 1\/2\" NPT tapped exhaust (Type 6200 standard)\u003c\/li\u003e\n\u003cli\u003e(2) 1\/4\" NPT Gauge Ports\u003c\/li\u003e\n\u003cli\u003eOptional Negative Bias: 4 psi (0.3 bar) negative bias of signal pressure to 'zero' I\/P's\u003c\/li\u003e\n\u003cli\u003eIEC 61508 SIL3 Certified\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eRapid Stroke Capability In A Rugged Aluminum Casing\u003c\/h2\u003e\u003cp\u003eThe Type 6100 aluminum volume booster is a 1:1 signal to output relays that is utilized in applications that require high forward airflow and exhaust capacities. Typically they are used to increase the throttling speed of large volume valve actuators. They are suitable for either diaphragm or piston actuators. A fixed deadband and adjustable bypass valve combine to allow small incremental downstream adjustment without opening the main booster valve. The bypass valve is used to adjust dynamic response to provide stable operation over a wide range of actuator sizes. Negative Bias adjustment (up to -4 psi) is available to “zero” downstream pressures when using standard signal pressure ranges.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eFlow Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 scfm (7,075 Nl.min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePort Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\" NPT, 1\/4\" NPT, 3\/4\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal Port Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/4\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Port Size (optional)\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/4\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eGauge Port Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/4\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMaximum Flow\/Exhaust Coefficient (Cv) 1\/4\" port\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e2 \/ 3.5\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMaximum Flow\/Exhaust Coefficient (Cv) 1\/2\" port\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e4.5 \/ 3.5\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMaximum Flow\/Exhaust Coefficient (Cv) 3\/4\" port\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e5 \/ 3.5\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Capacity (3\/4\" port)\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e80 scfm (2, 264 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal\/Output Ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1:1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eDeadband\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eless than 0.2 psig (0.01 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSupply Pressure Sensitivity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.1 psig (0.007 bar) for a 25 psi (1.7 bar) change in supply pressure\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Supply Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 psig (17 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Output Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 psig (10 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Signal Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 psig (10 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAmbient Temperature Limits\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\n\u003cdiv\u003e-40° to 200°F (-40° to 93°C)\u003c\/div\u003e\n\u003cdiv\u003eLow Temperature Option: -62° to 194°F (-52° to 90°C)\u003c\/div\u003e\n\u003cdiv\u003eExpanded Temperature Option: -65° to 284°F (-54° to 140°C)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eWeight\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e2.5 lbs (1.13 kg)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMounting Options\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eIn line, mounting bracket\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eAluminium\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOther Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eZinc platted steel, nitrile, silicone\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e429-841-387\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eFixed Negative Bias\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-6100-High-Flow-Capacity-Volume-Booster-Spec-Sheet.pdf?v=1786493229\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"ControlAir","offers":[{"title":"Default Title","offer_id":44165566988366,"sku":"429-841-387","price":503.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-6100-High-Flow-Capacity-Volume-Booster__31579.1784299849.1280.1280.jpg?v=1786659821"},{"product_id":"controlair-type-6100-series-high-flow-capacity-volume-booster-429-841-342-6100-da-aluminum-1-2-npt","title":"ControlAir Type 6100 Series High Flow Capacity Volume Booster, 429-841-342, 6100-DA, Aluminum, 1\/2\" NPT","description":"\u003ch2\u003eControlAir Type 6100 Series High Flow Capacity Volume Booster (6100-DA)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e1\/4”, 1\/2” or 3\/4\" NPT Porting\u003c\/li\u003e\n\u003cli\u003eAluminum or 316 Stainless Steel Construction\u003c\/li\u003e\n\u003cli\u003eIntegral Adjustable Bypass Valve: Allows small incremental signal changes without opening the primary valve.\u003c\/li\u003e\n\u003cli\u003eHigh Flow Capacity: For rapid actuator stroking.\u003c\/li\u003e\n\u003cli\u003eSoft Valve Seat Design Provides tight shutoff and eliminates leakage in steady state operation.\u003c\/li\u003e\n\u003cli\u003eHigh Temperature Operation: Up to 200°F (93°C), Optional 284°F (140°C)\u003c\/li\u003e\n\u003cli\u003eHigh Output Exhaust Vents: (2) 1\/4\" NPT tapped exhaust (Type 6100 option) 1\/2\" NPT tapped exhaust (Type 6200 standard)\u003c\/li\u003e\n\u003cli\u003e(2) 1\/4\" NPT Gauge Ports\u003c\/li\u003e\n\u003cli\u003eOptional Negative Bias: 4 psi (0.3 bar) negative bias of signal pressure to 'zero' I\/P's\u003c\/li\u003e\n\u003cli\u003eIEC 61508 SIL3 Certified\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eRapid Stroke Capability In A Rugged Aluminum Casing\u003c\/h2\u003e\u003cp\u003eThe Type 6100 aluminum volume booster is a 1:1 signal to output relays that is utilized in applications that require high forward airflow and exhaust capacities. Typically they are used to increase the throttling speed of large volume valve actuators. They are suitable for either diaphragm or piston actuators. A fixed deadband and adjustable bypass valve combine to allow small incremental downstream adjustment without opening the main booster valve. The bypass valve is used to adjust dynamic response to provide stable operation over a wide range of actuator sizes. Negative Bias adjustment (up to -4 psi) is available to “zero” downstream pressures when using standard signal pressure ranges.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eFlow Capacity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 scfm (7,075 Nl.min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePort Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/2\" NPT, 1\/4\" NPT, 3\/4\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal Port Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/4\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Port Size (optional)\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/4\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eGauge Port Size\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1\/4\" NPT\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMaximum Flow\/Exhaust Coefficient (Cv) 1\/4\" port\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e2 \/ 3.5\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMaximum Flow\/Exhaust Coefficient (Cv) 1\/2\" port\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e4.5 \/ 3.5\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMaximum Flow\/Exhaust Coefficient (Cv) 3\/4\" port\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e5 \/ 3.5\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eExhaust Capacity (3\/4\" port)\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e80 scfm (2, 264 Nl\/min)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSignal\/Output Ratio\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e1:1\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eDeadband\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eless than 0.2 psig (0.01 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eSupply Pressure Sensitivity\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e0.1 psig (0.007 bar) for a 25 psi (1.7 bar) change in supply pressure\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Supply Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e250 psig (17 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Output Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 psig (10 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMax. Signal Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e150 psig (10 bar)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eAmbient Temperature Limits\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\n\u003cdiv\u003e-40° to 200°F (-40° to 93°C)\u003c\/div\u003e\n\u003cdiv\u003eLow Temperature Option: -62° to 194°F (-52° to 90°C)\u003c\/div\u003e\n\u003cdiv\u003eExpanded Temperature Option: -65° to 284°F (-54° to 140°C)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eWeight\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e2.5 lbs (1.13 kg)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eMounting Options\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eIn line, mounting bracket\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eAluminium\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eOther Materials\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eZinc platted steel, nitrile, silicone\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e429-841-342\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-6100-High-Flow-Capacity-Volume-Booster-Spec-Sheet.pdf?v=1786493229\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"ControlAir","offers":[{"title":"Default Title","offer_id":44165567545422,"sku":"429-841-342","price":458.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-6100-High-Flow-Capacity-Volume-Booster__99375.1784299739.1280.1280.jpg?v=1786659824"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/collections\/0001-3889373750946987631.png?v=1790633443","url":"https:\/\/valveman.com\/collections\/volume-boosters.oembed?page=3","provider":"ValveMan","version":"1.0","type":"link"}