{"product_id":"controlair-type-950xp-series-explosion-proof-i-p-transducer-429-890-081-950-acat-4-20-ma-3-15-psi-0-2-1-bar-field-selectable-outputs-tapped-exhaust","title":"ControlAir Type 950XP Series Explosion-Proof I\/P Transducer, 429-890-081, 950-ACAT, 4 - 20 mA, 3 - 15 Psi (0.2  -1 Bar), Field Selectable Outputs, Tapped Exhaust","description":"\u003ch2\u003eControlAir Type 950XP Series, 950-ACAT Explosion-Proof I\/P Transducer\u003c\/h2\u003e \u003ch2\u003eFeatures:\u003c\/h2\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eOptional Field-Selectable Outputs: \u003c\/strong\u003eAllows you to stock only one unit for all outputs.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eApproved For Natural Gas:\u003c\/strong\u003e When purchased with option (E)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eRFI\/EMI Protected: \u003c\/strong\u003eEliminates susceptibility to electromagnetic interreference.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eCompact Size:\u003c\/strong\u003e Installs where others won’t.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eLow Air\/Gas Consumption:\u003c\/strong\u003e 3.0 scfh at mid range.\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e \u003ch2\u003eProcess Reliable \u0026amp; Field Rugged Electronic Pressure Regulator\u003c\/h2\u003e \u003cp\u003eNow there’s a compact I\/P transducer that delivers reliable high performance for the toughest applications in the most hazardous environments: the Type 950XP from ControlAir. The Type 950XP converts an electrical current signal to a stable, pneumatic output to actuate valves. Its NEMA 4X (IP65) housing is designed for both Intrinsically Safe* and Explosion-Proof* operation. Advanced circuitry includes electronic feedback control for superior vibration protection and highly accurate output.\u003c\/p\u003e \u003cp\u003eWith flow rates up to 12 SCFM (340 Nl\/min), the Type 950XP has the muscle to drive large valves and actuators. Yet because it typically consumes only 0.05 scfm (0.11 m3\/hr) at mid range, it not only costs less to buy, it costs less to operate as well. And because it takes impure air in stride, downtime is reduced, too.\u003c\/p\u003e \u003cp\u003eThe Type 950XP gives you big flexibility. Its small footprint can fit into tight spots. Its standard mounting bracket lets you mount it directly on a valve, wall, panel, or pipe. Optional, field-selectable process output ranges reduce downtime and inventory. And since the Type 950XP is position insensitive, it gives you even more freedom in mounting and connecting to valves and instruments. As a result of this flexibility, installation goes faster. Easy access Zero and Span adjustments make bench or field calibration quick and easy. For operating versatility, you may choose direct, reverse, and split range modes.\u003c\/p\u003e \u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e \u003cdiv class=\"tech\"\u003e \u003ch2\u003eTechnical Specifications\u003c\/h2\u003e \u003cdiv class=\"specs\"\u003e \u003cdiv class=\"column\"\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eInput\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e4-20 mA\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eOutput Range\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e0-33 psig (0-2.2 bar), 3-15 psig (0.2-1 bar), 3-27 psig (0.2-1.8 bar), 6-30 psig (0.40-2 bar)\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eMax. Supply Pressure\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e100 psig (7 bar)\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eAir Consumption\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e3.0 scfh (1.5 Nl\/min)\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eMaximum Flow Capacity\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e12 scfm (340 Nl\/min)\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eAmbient Temperature Limits\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e-40° to +158°F (-40° to +70°C)\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eTemperature Range (Storage)\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e-40° to +200°F (-40° to +93°C)\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eAccuracy, Hysteresis, and Repeatability\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e±0.10% of span (±0.25 with field-selectable option)\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eDeadband\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e0.02% of span\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003ePosition Effect\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eNo measurable effect\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eVibration Effect\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eLess than ±1.0% of span under the following conditions: 5-15Hz @ 0.8 inches constant displacement; 15-500Hz @ 10g’s\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eTemperature Effect\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e±0.045%\/°F (±0.07%\/°C) of span\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"column\"\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eReverse Polarity Effect\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eNo damage from reversal of normal supply current (4-20 mA) or from misapplication of up to 60 mA\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eRFI\/EMI Effect\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eLess than .5% of span change in output pressure per En 61000-4-3:1998, Amendment 1, Performance Criterion A\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003ePort Size\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e1\/4\" NPT\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003ePort Size (Electric)\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e1\/2\" NPT, M20 x 1.5 (ATEX)\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eMedia\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eClean, dry, oil-free, air-filtered to 40 micron Sweet natural gas or methane when purchased with the (E) option.\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eMounting\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eDirect wall, Panel, 2\" Pipe (optional)\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eMaterials (Body)\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eAluminum\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eMaterials (Other)\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eBuna-N, Stainless Steel, Brass, Zinc-plated Steel\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eWeight\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e1.8 lbs. (0.82 kg.)\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eWeight with \"E\" Option\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e2.3 lbs. (1.1 kg)\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e429-890-081\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eField Selectable Outputs: Yes, Tapped Exhaust: Yes\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"clear: both;\"\u003e\u003c\/div\u003e \u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-950XP-Explosion-Proof-I-P-Transducer-Spec-Sheet.pdf?v=1786493760\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"ControlAir","offers":[{"title":"Default Title","offer_id":44165631279182,"sku":"429-890-081","price":1105.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/ControlAir-Type-950XP-Explosion-Proof-I-P-Transducer__36445.1773676784.1280.1280.jpg?v=1786660484","url":"https:\/\/valveman.com\/products\/controlair-type-950xp-series-explosion-proof-i-p-transducer-429-890-081-950-acat-4-20-ma-3-15-psi-0-2-1-bar-field-selectable-outputs-tapped-exhaust","provider":"ValveMan","version":"1.0","type":"link"}