{"product_id":"noshok-611-series-small-diameter-submersible-level-transmitters-611-25-1-43-n-150-cbc-0-to-25-psig-1-of-span-accuracy-4-to-20-ma-output-hart®-with-cable-clamp-nose-cone-150-ft-polyurethane-pur-cable","title":"NOSHOK 611 Series Small Diameter Submersible Level Transmitters, 611-25-1-43-N-150-CBC, 0 to 25 psig, ±1% of Span Accuracy, 4 to 20 mA Output + HART® with Cable Clamp, Nose Cone \u0026 150 ft Polyurethane (PUR) Cable","description":"\u003ch2\u003e611 Series - Small Diameter Submersible Level Transmitters\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eHydrostatic level measurement for use in applications including bore holes and wells with small diameters (outer diameter 0.87\")\u003c\/li\u003e \u003cli\u003eLow power output signals for battery-powered applications, and optional temperature output available\u003c\/li\u003e \u003cli\u003e5:1 turndown using optional HART® signal\u003c\/li\u003e \u003c\/ul\u003e \u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e \u003cdiv class=\"tech\"\u003e \u003ch2\u003eTechnical Specifications\u003c\/h2\u003e \u003cdiv class=\"specs\"\u003e \u003cdiv class=\"column\"\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eType\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eSubmersible Level Transmitter\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eSeries\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e611\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003ePressure Range1\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e0 to 25 psig\u003c\/div\u003e \u003cdiv\u003e57.7 ft H2O\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eFull Scale Best Fit Straight Line (BFSL) Accuracy (±)\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e± 1.0% of span %\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eNote for Accuracy\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eIncludes non-linearity, hysteresis, zero offset and end value deviation per IEC 61298-2\u003c\/div\u003e \u003cdiv\u003eAccuracy after turndown via HART®, ≤ ±1.25% of scaled span (0.75% optional)\u003c\/div\u003e \u003cdiv\u003eTemperature sensor 14°F to 176°F (-10°C to 80°C): ≤ ± 3.3°F.\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eOutput Signal\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e4 mA to 20 mA, 2-Wire and HART® Signal\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eProcess Connections\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eNose Cone\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eElectrical Connection\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eStandard Polyurethane (PUR) Cable, Optional Water-Blocked Polyvinyl Chloride (PVC) Cable (200+ psi Only), Optional Fluorinated Ethylene Propylene (FEP) Cable (38)\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eOptions\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eCable Clamp\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eStyle\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eLevel Transmitter\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eApproximate Weight\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e10.6 oz\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eStorage Temperature [Min]\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e-40°C\u003c\/div\u003e \u003cdiv\u003e-40°F\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eStorage Temperature [Max]\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e80°C\u003c\/div\u003e \u003cdiv\u003e176°F\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eOptional Accuracy\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e± 0.5 of span\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eOptional Housing Material\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e318 LN\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eWarranty\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e3 yr\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eStability\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e≤ ± 0.1% of span per year\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eSwitch on Time (Output signals without HART®)\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e≤ 150 ms\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eSwitch on Time (Output Signals with HART®)\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e≤ 250 ms\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"column\"\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eSettling Time (Output Signals without HART®)\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e≤ 100 ms\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eSettling Time (Output Signals with HART®)\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e≤ 250 ms\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eDurability\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e\u0026lt; 100,000,000 full scale cycles\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003ePower Requirement2\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e4mA to 20 mA: 8 Vdc to 36 Vdc\u003c\/div\u003e \u003cdiv\u003e4 mA to 20 mA and HART®: 12-36 Vdc\u003c\/div\u003e \u003cdiv\u003e0.1 to 2.5 Vdc: 3.6 - 36 Vd\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eLoad Limitations\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e4 mA to 20 mA: ≤ (Vpower - 8 V) \/ 0.022 A\u003c\/div\u003e \u003cdiv\u003e4 mA to 20 mA and HART®: ≤ (Vpower - 9.6 V) \/ 0.022 A\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eProof Pressure\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e5 Times Range\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eMeasuring Element\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eCap: Polyvinylidene Fluoride (PVDF)\u003c\/div\u003e \u003cdiv\u003eSensor: 316 stainless steel, options Hastelloy C-276\u003c\/div\u003e \u003cdiv\u003eCable: Polyurethane, optional FEP\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eConnection Material\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e316 Stainless Steel\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eHousing Material\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e316 Stainless Steel\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eEnvironmental Rating\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eIngress Protection (IP68)\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eElectromagnetic Rating\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eEuropean Conformity (CE) Compliant to Electromagnetic Compatibility (EMC) Norm European Standards (EN) 61326:2014\/A1:1998, Radio Frequency Interference (RFI), Electromagnetic Interference (EMI) and Electrostatic Discharge (ESD) Protection\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eElectrical Protection\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eReverse polarity protection, short circuit and resistance to overvoltage :DC 40V and increased overvoltage for lightning protection. Normal discharge current ≤ 10 kA, Rise time 8\/20 µs\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eSubmersion Depth [Max]\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e325 ft (100 m)\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eVibration According to International Electrotechnical Commission (IEC) 60068-2-6\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e4 g\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eCable Length\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e150 ft\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e \u003ch2\u003eTemperature Ranges\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eCompensated Temperature Range \u003cbr\u003e \u003cul\u003e \u003cli\u003e32 to 176°F\u003c\/li\u003e \u003cli\u003e0 to 80°C\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003cli\u003eNote for Compensated Temperature Range \u003cbr\u003e \u003cul\u003e \u003cli\u003eEffect ± 0.01%\/°F for zero and span\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003cli\u003eStandard Media Temperature Range \u003cbr\u003e \u003cul\u003e \u003cli\u003e14 to 122°F\u003c\/li\u003e \u003cli\u003e-10 to 50°C\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003cli\u003eOptional Media Temperature Range \u003cbr\u003e \u003cul\u003e \u003cli\u003e-40 to 176°F\u003c\/li\u003e \u003cli\u003e-40 to 80°C\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003ch2\u003eProp 65 Warnings\u003c\/h2\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to \u003ca href=\"http:\/\/www.P65Warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003ch2\u003eLimitations Which Apply Are\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eThese units must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation.\u003cbr\u003e\u003cbr\u003eIn keeping with and for purposes of product and\/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice.\u003c\/li\u003e \u003c\/ul\u003e \u003ch2\u003eApplication\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eWell head measurement\u003c\/li\u003e \u003cli\u003eGroundwater monitoring\u003c\/li\u003e \u003cli\u003eLevel measurement in open bodies of water\u003c\/li\u003e \u003cli\u003eSewage lift and pumping stations\u003c\/li\u003e \u003cli\u003eSetting ponds and rainwater\u003c\/li\u003e \u003c\/ul\u003e \u003ch2\u003eAdditional Information\u003c\/h2\u003e \u003cul\u003e \u003cli\u003e316 Stainless Steel, PVDF and Polyurethane wetted parts\u003c\/li\u003e \u003cli\u003eCE compliant to suppress RFI, EMI and ESD\u003c\/li\u003e \u003cli\u003eIdeal for applications including well head measurement, groundwater monitoring, level measurement in open bodies of water, sewage lift and pumping stations, setting ponds and rainwater\u003c\/li\u003e \u003c\/ul\u003e \u003ch2\u003eOptions and Accessories\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eCable Clamp (CBC)\u003c\/li\u003e \u003cli\u003eLightning Protection (LP)\u003c\/li\u003e \u003cli\u003eCable Junction Box (NEMA 4X) (JB) (Not available with any hazardous location approved models)\u003c\/li\u003e \u003cli\u003eIncreased Media Temperature (-40°F to 176°F) (HT) (Must use FEP cable if used with hazardous location approved models)\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e \u003c\/p\u003e \u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Noshok-611-Series-Small-Diameter-Submersible-Level-Transmitter-Spec-Sheet.pdf?v=1786487715\"\u003eTechnical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"NOSHOK","offers":[{"title":"Default Title","offer_id":44164791435342,"sku":"611-25-1-43-N-150-CBC","price":1936.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Noshok-611-Series-Small-Diameter-Submersible-Level-Transmitter__21244.1750710222.1280.1280.jpg?v=1786653274","url":"https:\/\/valveman.com\/products\/noshok-611-series-small-diameter-submersible-level-transmitters-611-25-1-43-n-150-cbc-0-to-25-psig-1-of-span-accuracy-4-to-20-ma-output-hart%c2%ae-with-cable-clamp-nose-cone-150-ft-polyurethane-pur-cable","provider":"ValveMan","version":"1.0","type":"link"}