{"product_id":"noshok-628-series-intrinsically-safe-hammer-union-pressure-transmitter-628-10000-1-1j-14-3-0-to-10-000-psig-0-25-accuracy-best-fit-straight-line-bfsl-4-to-20-ma-output-pressure-transmitter-with-2-wing-union-and-6-pin-bayonet","title":"NOSHOK 628 Series Intrinsically Safe Hammer Union Pressure Transmitter 628-10000-1-1J-14-3, 0 to 10,000 psig, 0.25% Accuracy (Best Fit Straight Line (BFSL), 4 to 20 mA Output Pressure Transmitter with 2\" Wing Union and 6-Pin Bayonet","description":"\u003ch2\u003e628 Series - Intrinsically Safe Hammer Union Pressure Transmitters\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eRanges from 0 psig to 5,000 psig through 0 psig to 20,000 psig\u003c\/li\u003e \u003cli\u003eCurrent output\u003c\/li\u003e \u003cli\u003eInconel X-750 wetted parts\u003c\/li\u003e \u003c\/ul\u003e \u003cdiv class=\"column\"\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"right\"\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"tech\"\u003e \u003ch2\u003eTechnical Specifications\u003c\/h2\u003e \u003cdiv class=\"specs\"\u003e \u003cdiv class=\"column\"\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eType\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eSafe Hammer Union Pressure Transmitter\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eSeries\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e628\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003ePressure Range\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e0 to 10,000 psig\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eFull Scale Best Fit Straight Line (BFSL) Accuracy (±)\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e0.25 %\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eNote for Accuracy\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eIncludes the effects of non-linearity, hysteresis, non-repeatability, zero point and full scale errors.\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eOutput Signal\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e4 mA to 20 mA, 2-wire\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eProcess Connections\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e2\" Wing union (#1502)\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eElectrical Connection\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e6-Pin Bayonet (MIL-C-26482)\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eStorage Temperature [Min]\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e-40 ºC-40 ºF\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eStorage Temperature [Max]\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e-85 ºC185 ºF\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eStability\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e≤ ±0.2% full scale for 1 year, non-accumulating\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eResponse Time\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e\u0026lt; 2 ms\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eService Life\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e\u0026lt; 10,000,000 load cycles\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003ePower Requirement\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e10 Vdc to 28 Vdc\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eLoad Limitations\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e≤ (VPower-10)\/0.020 Amp\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eProof Pressure Range at 1.5 Times Full Scale [Max]\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e22,500 psi\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"column\"\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eBurst Pressure at 3 Times Full Scale [Max]\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e22,500 psi\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eMeasuring Element\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eInconel X-750\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eConnection Material\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eInconel X-750\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eHousing Material\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e316 Stainless Steel\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eEnvironmental Rating\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eIngress Protection (IP67) depending upon electrical connection\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eElectromagnetic Rating\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eEuropean Conformity (CE) Compliant to Electromagnetic Compatibility (EMC) Norm European Standards (EN) 61326:2014\/A1:1998, Radio Frequency Interference (RFI), Electromagnetic Interference (EMI) and Electrostatic Discharge (ESD) Protection\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eElectrical Protection\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eReverse polarity, over-voltage and short circuit protected\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eShock According to International Electrotechnical Commission (IEC) 60068-2-27\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e100 g\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eVibration According to International Electrotechnical Commission (IEC) 60068-2-6\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e15 g\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eWeight\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e6 lb\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eWarranty\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e3 yr\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e \u003ch2\u003eWiring Code Schematics\u003c\/h2\u003e \u003cul\u003e \u003cli\u003ePin A \u003cstrong\u003e+ Supply\u003c\/strong\u003e\n\u003c\/li\u003e \u003cli\u003ePin B \u003cstrong\u003e- Output\u003c\/strong\u003e\n\u003c\/li\u003e \u003cli\u003ePin D \u003cstrong\u003eGround\u003c\/strong\u003e\n\u003c\/li\u003e \u003cli\u003ePin E \u003cstrong\u003e+ Shunt Cal\u003c\/strong\u003e\n\u003c\/li\u003e \u003cli\u003ePin F \u003cstrong\u003e- Shunt Cal\u003c\/strong\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003ch2\u003eTemperature Ranges\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eCompensated Temperature Range \u003cbr\u003e \u003cul\u003e \u003cli\u003e40 to 140 ºF\u003c\/li\u003e \u003cli\u003e5 to 60 ºC\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003cli\u003eNote for Compensated Temperature Range \u003cbr\u003e \u003cul\u003e \u003cli\u003eZero effect is ±0.01% full scale\/ºF\u003c\/li\u003e \u003cli\u003eSpan effect is ±0.01% full scale\/ºF\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003cli\u003eMedia Temperature Range \u003cbr\u003e \u003cul\u003e \u003cli\u003e-40 to 185 ºF\u003c\/li\u003e \u003cli\u003e-40 to 85 ºC\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003cli\u003eAmbient Temperature Range \u003cbr\u003e \u003cul\u003e \u003cli\u003e-40 to 185 ºF\u003c\/li\u003e \u003cli\u003e-40 to 85 ºC\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003ch2\u003eLimitations Which Apply Are\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eThese units must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation.\u003cbr\u003e\u003cbr\u003eIn keeping with and for purposes of product and\/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice.\u003c\/li\u003e \u003c\/ul\u003e \u003ch2\u003eApplication\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eAcidizing\u003c\/li\u003e \u003cli\u003eChoke \u0026amp; kill manifold\u003c\/li\u003e \u003cli\u003eFracturing \u0026amp; cementing\u003c\/li\u003e \u003cli\u003eMud logging \u0026amp; mud pumps\u003c\/li\u003e \u003cli\u003eOil field \u0026amp; offshore\u003c\/li\u003e \u003cli\u003eWell head measurement\u003c\/li\u003e \u003c\/ul\u003e \u003ch2\u003eAdditional Information\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eCanadian Standards Association approved\u003c\/li\u003e \u003cli\u003eEvery sensor comes with a Certificate of Calibration\u003c\/li\u003e \u003cli\u003eCertifications pending:\u003cbr\u003e \u003cul\u003e \u003cli\u003eFactory Mutual\u003c\/li\u003e \u003cli\u003eATEX\u003c\/li\u003e \u003cli\u003eCE\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003cli\u003eNOSHOK 628 Series transmitters are Canadian Standards Association approved for use in hazardous location applications as follows:\u003cbr\u003e \u003cul\u003e \u003cli\u003eIntrinsically Safe\u003cbr\u003e \u003cul\u003e \u003cli\u003eClass I, DIV 1, Groups A,B,C,D, -40 ºC, Tamb \u0026lt;+85 ºC T4\u003c\/li\u003e \u003cli\u003eClass II, DIV 1, Groups E, F, G,\u003c\/li\u003e \u003cli\u003eClass III,\u003c\/li\u003e \u003cli\u003eClass I, Zone 0 AEx\/Ex ic IIC T4.\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003cli\u003eNon-Incendive\u003cbr\u003e \u003cul\u003e \u003cli\u003eClass I, DIV 2, Groups A, B , C, D, -40 ºC, Tamb \u0026lt;+85 ºC T4\u003c\/li\u003e \u003cli\u003eClass II, DIV 2, Groups F, G\u003c\/li\u003e \u003cli\u003eClass III,\u003c\/li\u003e \u003cli\u003eClass I, Zone 2 AEx\/Ex ic IIC T4.\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003cli\u003eIdeal for applications including acidizing, choke \u0026amp; kill manifold, fracturing \u0026amp; cementing; mud logging \u0026amp; mud pumps, oil field \u0026amp; offshore and well head measurement\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003ch2\u003eOptions and Accessories\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eOptions and Accessories \u003cbr\u003e \u003cul\u003e \u003cli\u003eCarrying Handle (CH)\u003c\/li\u003e \u003cli\u003eElectrical Connector Cage (EC)\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003cli\u003eDigital Indicators \u003cbr\u003e \u003cul\u003e \u003cli\u003eNOSHOK Digital Indicators provide local indication for pressure, level and temperature transmitters.\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003cli\u003ePressure Snubbers - Piston Type \u003cbr\u003e \u003cul\u003e \u003cli\u003eResist clogging and are self-cleaning\u003c\/li\u003e \u003cli\u003eFive different sized pistons included with each snubber to ensure the correct amount of snubbing for virtually every application\u003c\/li\u003e \u003cli\u003eAvailable in Brass and 316 Stainless Steel in 1\/4\" NPT, 1\/2\" NPT or SAE J1926-3: 7\/16-20\u003c\/li\u003e \u003cli\u003eWeight approximately 0.2 lb. for 1\/4\" \u0026amp; 7\/16\", and approximately 0.4 lb. for 1\/2\"\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003cli\u003ePressure Snubbers - Sintered Type \u003cbr\u003e \u003cul\u003e \u003cli\u003eCost effective solution to protect expensive instrumentation\u003c\/li\u003e \u003cli\u003eIncreases gauge readability by smoothing out pressure surges, pulsations and spikes\u003c\/li\u003e \u003cli\u003e5 basic elements available for each snubber to accommodate specific application needs\u003c\/li\u003e \u003cli\u003eSnubbing action achieved by utilizing a corrosion resistant 316 Stainless Steel sintered porous element\u003c\/li\u003e \u003cli\u003eExotic materials or intermediate disc grades available\u003c\/li\u003e \u003cli\u003eProvides long service life with no moving parts to wear out\u003c\/li\u003e \u003cli\u003eWeight approximately 0.2 lb. for 1\/4\" \u0026amp; 7\/16\", and approximately 0.4 lb. for 1\/2\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003cli\u003eSteam Syphons \u003cbr\u003e \u003cul\u003e \u003cli\u003eProtect the instrument from the damaging effects of high temperature steam\u003c\/li\u003e \u003cli\u003eRecommended for use in all steam applications\u003c\/li\u003e \u003cli\u003eAvailable in 1\/4\" and 1\/2\" NPT sizes in welded steel, welded 316 Stainless Steel or seamless 316 Stainless Steel with ratings to 3,800 psi at 850 ºF\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003cli\u003eSwivel Adapters \u003cbr\u003e \u003cul\u003e \u003cli\u003eTemperature ratings: 15,000 psi at 200 ºF and 3,000 psi at 1,000 ºF\u003c\/li\u003e \u003cli\u003eUsed with gauges and gauge valves to adjust the line of sight\u003c\/li\u003e \u003cli\u003eRotates 360º to allow the connected instrument to be positioned in the desired direction\u003c\/li\u003e \u003cli\u003eThe pressure connection is achieved with a tapered cone style compression fitting simply by tightening the swivel hex nut\u003c\/li\u003e \u003cli\u003eAll 316 Stainless Steel construction\u003c\/li\u003e \u003cli\u003eStandard with 1\/2\" NPT male process - 1\/2\" NPT female instrument connections\u003c\/li\u003e \u003cli\u003eAlso available with 1\/4\" NPT connections, same specifications apply\u003c\/li\u003e \u003cli\u003eWeight approximately 0.8 lb.\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003ch2\u003eProp 65 Warnings\u003c\/h2\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including Nickel, which is known to the State of California to cause cancer. For more information go to \u003ca href=\"http:\/\/www.P65Warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e \u003c\/p\u003e \u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Noshok-628-Series-Intrinsically-Safe-Hammer-Union-Pressure-Transmitters-Spec-Sheet.pdf?v=1786487472\"\u003eTechnical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"NOSHOK","offers":[{"title":"Default Title","offer_id":44164772626510,"sku":"628-10000-1-1J-14-3","price":2338.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Noshok-628-Series-Intrinsically-Safe-Hammer-Union-Pressure-Transmitters__10306.1750273730.1280.1280.jpg?v=1786653073","url":"https:\/\/valveman.com\/products\/noshok-628-series-intrinsically-safe-hammer-union-pressure-transmitter-628-10000-1-1j-14-3-0-to-10-000-psig-0-25-accuracy-best-fit-straight-line-bfsl-4-to-20-ma-output-pressure-transmitter-with-2-wing-union-and-6-pin-bayonet","provider":"ValveMan","version":"1.0","type":"link"}