{"product_id":"noshok-800-series-platinum-resistance-temperature-transmitters-800-25-125-1-1-8-8-090-6-25-125-f-4-to-20-ma-output-1-2-npt-process-connection-9-stem-6mm-diameter-din-en-175301-803-form-a","title":"NOSHOK 800 Series Platinum Resistance Temperature Transmitters, 800-25\/125-1-1-8-8-090-6, 25\/125 ˚F, 4 to 20 mA Output, 1\/2\" NPT Process Connection, 9\" Stem, 6mm Diameter, DIN EN 175301-803 Form A","description":"\u003ch2\u003e800 Series - Platinum Resistance Temperature Transmitters\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eProven 100 Ω platinum resistance sensor provides reliability, stability \u0026amp; unbeatable performance\u003c\/li\u003e \u003cli\u003eEconomical price\u003c\/li\u003e \u003cli\u003eWide variety of temperature ranges and connections\u003c\/li\u003e \u003c\/ul\u003e \u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e \u003cdiv class=\"tech\"\u003e \u003ch2\u003eTechnical Specifications\u003c\/h2\u003e \u003cdiv class=\"specs\"\u003e \u003cdiv class=\"column\"\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eType\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eTransmitter\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eSeries\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e800\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eElectromagnetic Rating\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eEuropean Conformity (CE) Compliant to Electromagnetic Compatibility (EMC) Norm European Standards (EN) 61326:1997\/A1:1998, Radio Frequency Interference (RFI), Electromagnetic Interference (EMI) and Electrostatic Discharge (ESD) Protection\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eConnection Type\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eMale National Pipe Thread (MNPT)\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eWetted Materials\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e316 Stainless Steel\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eTemperature Ranges [Min]\u003c\/div\u003e \u003cdiv class=\"right\"\u003e25 ºF\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eTemperature Ranges [Max]\u003c\/div\u003e \u003cdiv class=\"right\"\u003e125 ºF\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eHousing Material\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e316 Stainless Steel\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eConnection Size\u003c\/div\u003e \u003cdiv class=\"right\"\u003e1\/2 in\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eOutput Signal\u003c\/div\u003e \u003cdiv class=\"right\"\u003e4 to 20 mA, 2-Wire\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eElectrical Connection\u003c\/div\u003e \u003cdiv class=\"right\"\u003eDIN EN 175301-803 Form A\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003ePower Supply\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e10 to 30 Vdc (4 to 20 mA, 2-Wire)\u003c\/div\u003e \u003cdiv\u003e10 to 30 Vdc (0 to 5 Vdc, 3-Wire)\u003c\/div\u003e \u003cdiv\u003e10 to 30 Vdc (1 to 5 Vdc, 3-Wire)\u003c\/div\u003e \u003cdiv\u003e14 to 30 Vdc (0 to 10 Vdc, 3-Wire)\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eAccuracy\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eClass B + (±0.5 % Best Fit Straight Line (BFSL))\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eStorage Temperature [Max]\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e85 ºC\u003c\/div\u003e \u003cdiv\u003e185 ºF\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eStorage Temperature [Min]\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e-40 ºC\u003c\/div\u003e \u003cdiv\u003e-40 ºF\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"column\"\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eStandard Temperature Ranges\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e-40 to 120 ºF\u003c\/div\u003e \u003cdiv\u003e50 to 400 ºF\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eSensor Protection\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eBurnout Protected from 3.3 to 23 mA\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eMeasuring Element\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eClass B per Norm European Standards (EN) 60751 (International Electrotechnical Commission (IEC 751))\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eOutput\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e±[0.30 + 0.005 ltl] ºC\u003c\/div\u003e \u003cdiv\u003e±0.5% Full Scale\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eLoad Limitations\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e≤(VPower - 10)\/0.020 Amp for 4 to 20 mA output\u003c\/div\u003e \u003cdiv\u003e≤5000 Ω for 1 to 5 Vdc output\u003c\/div\u003e \u003cdiv\u003e≤10, 000 Ω for 0 to 10 Vdc output\u003c\/div\u003e \u003cdiv\u003e≤4500 Ω for 0.5 to 4.5 Vdc output\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003ePressure Rating\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e725 psi\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eAmbient Temperature Range\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e-40 to 185 ºF-40 to 85 ºC\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eEnvironmental Protection\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eIngress Protection (IP65) According to Norm European Standards (EN) 60529\/(International Electrotechnical Commission (IEC 529))\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eElectrical Protection\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003eReverse polarity, over-voltage and short circuit protection\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eApproximate Weight\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e4 oz\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eWarranty\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e3 yr\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eStem Diameters\u003c\/div\u003e \u003cdiv class=\"right\"\u003e \u003cdiv\u003e6 mm\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eStem Lengths\u003c\/div\u003e \u003cdiv class=\"right\"\u003e9 in\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e \u003cp\u003e \u003c\/p\u003e \u003ch2\u003e\u003cspan itemprop=\"value\" data-measure=\"general\"\u003eRelated Items\u003c\/span\u003e\u003c\/h2\u003e \u003cul\u003e \u003cli\u003e\n\u003cspan itemprop=\"value\" data-measure=\"general\"\u003e\u003ca class=\"text2\" href=\"https:\/\/catalog.noshok.com\/item\/all-categories\/thermowells\/50-090-304-ss\"\u003e50-090-304-SS\u003c\/a\u003e, 1\/2\" National Pipe Thread (NPT) Stepped Shank, 9\" Length, 1\/2\" National Pipe Straight Mechanical (NPSM) Instrument Connection, 304 Stainless Steel Thermowell\u003c\/span\u003e\u003cbr\u003e\u003cspan itemprop=\"value\" data-measure=\"general\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e \u003cli\u003e\n\u003cspan itemprop=\"value\" data-measure=\"general\"\u003e\u003ca class=\"text2\" href=\"https:\/\/catalog.noshok.com\/item\/all-categories\/thermowells\/75-090-304-ss\"\u003e75-090-304-SS\u003c\/a\u003e, 3\/4\" National Pipe Thread (NPT) Stepped Shank, 9\" Length, 1\/2\" National Pipe Straight Mechanical (NPSM) Instrument Connection, 304 Stainless Steel Thermowell\u003c\/span\u003e\u003cbr\u003e\u003cspan itemprop=\"value\" data-measure=\"general\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e \u003cli\u003e\u003cspan itemprop=\"value\" data-measure=\"general\"\u003e\u003ca class=\"text2\" href=\"https:\/\/catalog.noshok.com\/item\/all-categories\/thermowells\/75-090-316-ss\"\u003e75-090-316-SS\u003c\/a\u003e, 3\/4\" National Pipe Thread (NPT) Stepped Shank, 9\" Length, 1\/2\" National Pipe Straight Mechanical (NPSM) Instrument Connection, 316 Stainless Steel Thermowell\u003c\/span\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch2\u003e\u003cspan itemprop=\"value\" data-measure=\"general\"\u003eProp 65 Warnings\u003c\/span\u003e\u003c\/h2\u003e \u003cul\u003e \u003cli\u003e\u003cspan itemprop=\"value\" data-measure=\"general\"\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to \u003ca href=\"http:\/\/www.P65Warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch2\u003e\u003cspan itemprop=\"value\" data-measure=\"general\"\u003eApplication\u003c\/span\u003e\u003c\/h2\u003e \u003cul\u003e \u003cli\u003e\u003cspan itemprop=\"value\" data-measure=\"general\"\u003eWater systems\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan itemprop=\"value\" data-measure=\"general\"\u003eStorage tanks\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan itemprop=\"value\" data-measure=\"general\"\u003eIndustrial machinery and machine tools\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan itemprop=\"value\" data-measure=\"general\"\u003eHVAC systems\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan itemprop=\"value\" data-measure=\"general\"\u003eRefrigeration systems\u003c\/span\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch2\u003eLimitations Which Apply Are\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eThese units must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation.\u003cbr\u003e\u003cbr\u003eIn keeping with and for purposes of product and\/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice.\u003c\/li\u003e \u003c\/ul\u003e \u003ch2\u003eAdditional Information\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eQuick response time\u003c\/li\u003e \u003cli\u003eAlso available with our 1800 Series attachable loop indicator (see options \u0026amp; accessories below)\u003c\/li\u003e \u003cli\u003eCE compliant to suppress RFI, EMI, and ESD\u003c\/li\u003e \u003c\/ul\u003e \u003ch2\u003eOptions and Accessories\u003c\/h2\u003e \u003cul\u003e \u003cli\u003e1800 Series Attachable Loop-Powered Digital Indicators \u003cbr\u003eNOSHOK 1800 Series Attachable Loop-Powered Digital Indicators can be fitted to certain NOSHOK pressure transmitters utilizing a 4 mA to 20 mA output signal and the DIN EN 175301-803 Form A Electrical Connection.\u003c\/li\u003e \u003cli\u003eThermowells \u003cbr\u003eThermowells allow a temperature instrument to be removed and replaced without shutting down and draining the process, and reduce the possibility of damage to the temperature instrument.\u003c\/li\u003e \u003c\/ul\u003e \u003ch2\u003eNote\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eThermowells are recommended for pressure, corrosive fluids and high velocity applications.\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e \u003c\/p\u003e \u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Noshok-800-Series-Platinum-Resistance-Temperature-Transmitters-Spec-Sheet.pdf?v=1786488736\"\u003eTechnical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"NOSHOK","offers":[{"title":"Default Title","offer_id":44164909826126,"sku":"800-25\/125-1-1-8-8-090-6","price":309.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Noshok-800-Series-Platinum-Resistance-Temperature-Transmitters__96126.1782311449.1280.1280.jpg?v=1786654515","url":"https:\/\/valveman.com\/products\/noshok-800-series-platinum-resistance-temperature-transmitters-800-25-125-1-1-8-8-090-6-25-125-f-4-to-20-ma-output-1-2-npt-process-connection-9-stem-6mm-diameter-din-en-175301-803-form-a","provider":"ValveMan","version":"1.0","type":"link"}