{"product_id":"tek-trol-tek-bar-3800xa-l3-1-k1-q-4-a-01-en-l1-v1-explosion-proof-multivariable-transmitter-1000-dp-5945-psia","title":"Tek-Trol Tek-Bar 3800XA-L3-1-k1-\nQ-4-A-01-EN-L1-\nV1, Explosion Proof Multivariable Transmitter, +\/- 1000 DP, 5945 psia","description":"\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTek-Trol Tek-Bar 3800XA-L3-1-k1-Q-4-A-01-EN-L1-V1, Explosion Proof Multivariable Transmitter Technical Specs\u003c\/h2\u003e\n\u003ch2\u003eFeatures \u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAutomatic static pressure and temperature compensation.\u003c\/li\u003e\n\u003cli\u003eEasy configuration \u0026amp; calibration.\u003c\/li\u003e\n\u003cli\u003eField-replaceable modules reduce downtime.\u003c\/li\u003e\n\u003cli\u003eFlexible configuration options.\u003c\/li\u003e\n\u003cli\u003eUniversal transmitter terminals save installation and start-up time.\u003c\/li\u003e\n\u003cli\u003eLarge turn down ratio of up to 100:1.\u003c\/li\u003e\n\u003cli\u003eIntegrated counting function.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"column\"\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eItem\u003c\/div\u003e \u003cdiv class=\"right\"\u003eExplosion Proof Multivariable Transmitter\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eWetted Material\u003c\/div\u003e \u003cdiv class=\"right\"\u003eHastelloy C-276 \/ Silicone Oil\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eProcess Connection\u003c\/div\u003e \u003cdiv class=\"right\"\u003e1\/4\" FNPT\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eMeasuring Range\u003c\/div\u003e \u003cdiv class=\"right\"\u003eDifferential Pressure:1 kPa to 10 mbar \/ 4 in H2O to -1 kPa to -10 mbar\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"right\"\u003eAbsolute Pressure: up to 60 bar \/ 870 psi\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eAccuracy\u003c\/div\u003e \u003cdiv class=\"right\"\u003eDifferential: up to ±0.04%, Static:up to ±0.0375%, Temperature:up to ±0.2°C\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"column\"\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eOutput Signal\u003c\/div\u003e \u003cdiv class=\"right\"\u003e4-20mA and HART Digital Communication\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eOperating Temperature\u003c\/div\u003e \u003cdiv class=\"right\"\u003eProcess: -200°C to 850°C ; Storage:-67°F to 248°F\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003ePower Supply\u003c\/div\u003e \u003cdiv class=\"right\"\u003e10.5 to 30 VDC\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eVent\u003c\/div\u003e \u003cdiv class=\"right\"\u003eSide Vent\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"left\"\u003eApproval\u003c\/div\u003e \u003cdiv class=\"right\"\u003eCombined ATEX \/ IECX and FM approvals (USA \/ Canada) \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv\u003e\n\u003cbr\u003e \u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-Tek-Bar-3800XA-Explosion-Proof-Multivariable-Transmitter-Catalog.pdf?v=1786492062\" target='_blank\"'\u003eCatalog\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-Tek-Bar-3800XA-Explosion-Proof-Multivariable-Transmitter-Instruction-Manual.pdf?v=1786492068\" target='_blank\"'\u003eManual\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-Tek-Bar-3800XA-Explosion-Proof-Multivariable-Transmitter-Quick-Start-Guide.pdf?v=1786492073\" target='_blank\"'\u003eQuick Start Guide\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol-Tek-Bar-3800XA-Explosion-Proof-Multivariable-Transmitter-Datasheet.pdf?v=1786492078\" target='_blank\"'\u003eDatasheet\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Tek-Trol","offers":[{"title":"Default Title","offer_id":44165325324366,"sku":"3800XA-L3-1-k1-Q-4-A-01-EN-L1-V1","price":6776.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Tek-Trol_252520Tek-Bar_2525203800XA_252520Explosion_252520Proof_252520Multivariable_252520Transmitter.__20304.1767024967.1280.1280.png?v=1786658095","url":"https:\/\/valveman.com\/products\/tek-trol-tek-bar-3800xa-l3-1-k1-q-4-a-01-en-l1-v1-explosion-proof-multivariable-transmitter-1000-dp-5945-psia","provider":"ValveMan","version":"1.0","type":"link"}