{"product_id":"watson-mcdaniel-usib450h-015-inverted-bucket-trap-module-stainless-steel-body-15-psig-high-capacity-1-4-orifice-2-bolt-quick-change-universal-connector","title":"Watson McDaniel USIB450H-015 Inverted Bucket Trap Module, Stainless Steel Body, 15 PSIG (High-Capacity), 1\/4\" Orifice, 2-Bolt Quick-Change Universal Connector","description":"\u003ch2\u003eWatson McDaniel USIB450H-015 Inverted Bucket Trap Module, 15 PSIG PMO (2-Bolt Quick-Change Universal Connector)\u003c\/h2\u003e\u003ch2\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eTrap module can be easily removed and replaced in minutes without having to disconnect any piping.\u003c\/li\u003e\n\u003cli\u003eHardened stainless steel valves and seat.\u003c\/li\u003e\n\u003cli\u003eFreeze Resistant\u003c\/li\u003e\n\u003cli\u003eConnectors available with integral strainers and blowdown valves.\u003c\/li\u003e\n\u003cli\u003e360° swivel design for convenient installation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOptions \u0026amp; Features (See Specification Sheet For Full List):\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eUSIB450H Inverted Bucket Trap Module (High-Capacity)\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eDRIP, TRACING:\u003c\/strong\u003e The USIB450 inverted bucket steam trap modules must be mounted to a Universal Connector. They are typically used for drip applications such as draining condensate from steam mains or steam supply lines as well as for steam tracing applications. USIB450H is the higher capacity model. All USIB450 modules mounts to any 2-bolt Quick-Change Universal Connector.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDRIP, TRACING:\u003c\/strong\u003e The USIB450 inverted bucket steam trap modules must be mounted to a universal connector. They are typically used for drip applications such as draining condensate from steam mains or steam supply lines as well as for steam tracing applications. USIB450H is the higher capacity model. Steam trap modules can be used with other manufacturers’ Universal Connectors. See installation and Maintenance regarding using trap in superheated applications.\u003c\/p\u003e\u003ch2\u003eHow It Works\u003c\/h2\u003e\u003cp\u003eThe UC450 universal connector is permanently installed into the pipeline where the steam trap would normally be placed. The trap module, which functions like any standard inverted bucket steam trap, is fastened to the universal connector with two bolts. When a new trap module is needed, it can be easily removed and replaced with a standard open-end or socket wrench without disturbing the existing piping.\u003c\/p\u003e\u003ch2\u003eSelection \/ Sizing \/ Capacities\u003c\/h2\u003e\u003cp\u003eFrom the capacity chart, select the model that can handle the working pressure of the system (PMO). Select the appropriate trap that will meet the capacity requirements at the differential pressure.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eExample:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eApplication: 620lbs\/hr at 50PSIG working pressure and 23 PSI differential pressure\u003c\/li\u003e\n\u003cli\u003eSize\/Model: USIB450H-70, at maximum working pressure at 70PSIG and 23 PSI differential pressure can handle the max condensate about 650lbs\/hr.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eOptions\u003c\/h2\u003e\u003cp\u003eUniversal Connectors are available with an integral strainer and blowdown valve. Connector is purchased separately. See the UC450 Universal Connectors section for more information.\u003c\/p\u003e\u003ch2\u003eInstallation and Maintenance\u003c\/h2\u003e\u003cp\u003eUniversal connector is first permanently threaded or welded into piping system. The USIB trap module is attached to the universal connector with two bolts. When a new trap is needed, it can be easily removed and replaced with a standard open-end or socket wrench without disturbing the existing piping. Trap must be installed in upright position as shown to function properly. With superheated steam, a check valve must be installed at inlet of trap to prevent the loss of prime. In vertical piping installations with upward flow, use of a blowdown valve is not recommended because discharge would be in upward and possibly unsafe direction.\u003c\/p\u003e\u003ch2\u003eSample Specification\u003c\/h2\u003e\u003cp\u003eThe steam trap shall be an all stainless steel modular design, inverted bucket type with a frictionless valve lever assembly. The trap shall have a 360 degree swivel mount on a stainless steel Universal Connector that is available with integral strainer and blowdown valve options.\u003c\/p\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003cdiv class=\"tech\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eModel\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eUSIB450H\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eConnections\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eFits UC450 Series Universal Connectors\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eBody Material\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eStainless Steel\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMO Max. Operating Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e450 PSIG*\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMO Max. Operating Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e800°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePMA Max. Allowable Pressure\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e720 PSIG @ 100°F\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003eTMA Max. Allowable Temperature\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003e800°F @ 400 PSIG\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"left\"\u003ePart Number\u003c\/div\u003e\n\u003cdiv class=\"right\"\u003e\u003cdiv\u003eUSIB450H-015\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"clear: both;\"\u003e \u003c\/div\u003e\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-USIB450-Inverted-Bucket-Trap-Module-Spec-Sheet.pdf?v=1786495066\"\u003eView Technical Specification Sheet Here\u003c\/a\u003e\u003c\/h2\u003e","brand":"Watson McDaniel","offers":[{"title":"Default Title","offer_id":44165961744462,"sku":"USIB450H-015","price":619.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0721\/4576\/4430\/files\/Watson-McDaniel-USIB450-Inverted-Bucket-Trap-Module__22742.1777454819.1280.1280.jpg?v=1786664653","url":"https:\/\/valveman.com\/products\/watson-mcdaniel-usib450h-015-inverted-bucket-trap-module-stainless-steel-body-15-psig-high-capacity-1-4-orifice-2-bolt-quick-change-universal-connector","provider":"ValveMan","version":"1.0","type":"link"}