Watson McDaniel Authorized Distributor

Watson McDaniel PP5 Series Pressure Pilots, Cast Steel Body, High-Accuracy, Yellow, Blue Spring, Spence 1 - 25 PSIG

SKU: WM-PP5-SP-D5
Made in the United States
Starting at $1,192.99

Select a Size to Order This page shows the full valve series. Choose a specific pipe size below to view pricing and add to cart.

Available Sizes
Pressure Pilot(Standard: 1.0 Psig Accuracy) PP
Pilot Body MaterialCast Steel
Buying for a facility?

Custom quote, volume pricing, or Net 30 terms available.

Request a Formal Quote or call 888-825-8800
Sourced from Vetted Suppliers Every product is quality-checked from certified manufacturers
Need It Fast? Call 888-825-8800
30-Day Returns · see policy
Expert Support: 888-825-8800

Technical Specifications

General

Part NumberN/A
BrandWatson McDaniel
Manufacturer Part #WM-PP5-SP-D5
Country of OriginMade in the United States

Materials & Construction

Pilot Body MaterialCast Steel

Performance

Pressure Pilot(Standard: 1.0 Psig Accuracy) PP
Max Inlet Pressure300 PSIG
Reduced Outlet Pressure RangeSpence 1 - 25 PSIG
Inlet Pressure RangeHD Standard Main Valve:15-300 PSIG
Minimum Differential PressureHD Standard Main Valve: 10 PSI

Overview

Watson McDaniel PP Series Pressure Pilots For HD Regulating Valves (Spence 1 - 25 PSIG)

Features:

  • The PP-Pilot can maintain downstream pressure to ±1 PSIG.
  • PP5-Pilot can maintain downstream pressure to ±0.5 PSIG.
  • Choices of three overlapping pressure ranges.
  • Pilot is easily installed on pilot adapter using four bolts, no tubing connections are required.
  • Full port strainer and blowdown valve on pilot adapter for protection of pilot from dirt and scale.
  • Solid floating diaphragm is more failure resistant.
  • Watson McDaniel's pilots can be used with other manufacturers’ regulators.

Options & Features (See Specification Sheet For Full List):

PP & PP5 Pilots

The PP & PP5 Pressure Pilots are used with the HD Regulator to control steam pressure in steam mains or for process equipment. Pilot-operated regulators maintain constant downstream pressure even when the inlet pressure to the valve fluctuates or steam usage varies. The PP-Pressure Pilot is adequate for controlling pressure in most industrial applications. For increased accuracy use the PP5 Pilot.

A Pressure Pilot is used with the HD Regulator to control steam pressure in steam mains or for process equipment. The PP-Pressure Pilot (1.0 PSIG accuracy) is adequate for controlling pressure in most industrial applications. For increased accuracy use PP-5 Pilot. (0.5 PSIG accuracy).

The PP & PP5 Pressure Pilots are used with the HD Regulator to control steam pressure in steam mains or for process equipment. Pilot-operated regulators maintain constant downstream pressure even when the inlet pressure to the valve fluctuates or steam usage varies. The PP-Pressure Pilot is adequate for controlling pressure in most industrial applications. For increased accuracy use the PP5 Pilot.

  • PP-Pressure Pilot (Standard) 1.0 PSIG accuracy.
  • PP5-Pressure Pilot (Special Applications) 0.5 PSIG accuracy.

Options

  • Pressure pilot can be used with temperature pilot to eliminate the need for two separate regulators.
  • Solenoid pilot can be added for remote on/off control of regulator.

Controlling Pressure

The PP and PP5 Pilots are both spring-adjusted pressure pilots. The PP-Pilot is used on typical general purpose pressure reducing applications. The PP5-Pilot is used when higher accuracy is required and is capable of maintaining a control pressure window of less than 1 PSI.

How It Works

The Pressure Pilot controls the operation of the HD Regulator. The sensing line connects the pressure pilot to the downstream side of the regulator. Pressure in the sensing line applies an upward force to the pilot diaphragm to compress the adjustment spring. When system pressure equals set point, the diaphragm moves upwards against the force of the adjusting spring, closing pilot valve. When the pilot valve is shut, steam cannot pass thru to the underside of the regulator diaphragm, closing the regulator. When the steam pressure falls below its set point, the pilot valve opens allowing steam to lift the main valve diaphragm which opens up the regulating valve.